• 제목/요약/키워드: DC relay

검색결과 87건 처리시간 0.028초

기동방식을 고려한 DC급전계통 보호알고리즘 (A Protection Algorithm for DC Railway Systems Considering Train Starting)

  • 권영진;최동민;강상희;한문섭;이재경
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 A
    • /
    • pp.307-309
    • /
    • 2004
  • A DC railway system has low feeder voltage, The remote fault current can be smaller than the current of load starting. So it is important to discriminate between the small fault current and the train starting current. The train starting current increases step by step but the fault current increases all at once. So the type of $\bigtriangleup I\;relay(50F)$ was developed using the different characteristics between the load starting current and the fault current. As for the train starting current, the time constant of train current at each step is much smaller than that of the fault current. To detect faults in U railway systems, an algorithm that is independent of train starting current. This algorithm use the time constant calculated by the method of least squares is presented in this paper.

  • PDF

히스테리시스를 갖는 온-오프 제어기에 의한 서보모터의 제어 (Servo Motor Control by On-Off Controller with Hysterisis)

  • 김영복;김성환;양주호;정병건
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제15권1호
    • /
    • pp.85-95
    • /
    • 1991
  • All physical systems are nonlinear to some degree. The examples are relay, backlash, deadzone, saturation element and so on. In the linear control system design, it is useful method to restrict the nonlinearity to the linearity of system over the operation range. It is worth noting that nonlinearities may be intentionally introduced in to a system. A simple of an intentional non-linearity is the Bang-Bang controller which uses the On-Off relay. In this paper, an angular position servosystem made of a DC servomotor controlled by a microcomputer is discribed. Authors use two methods in the design of controller. The one is linear controller designed by the optimal feedback control theory only and the other is nonlinear controller designed by On-Off relay with optimal feedback control theory. To do the real time control, the controller is designed by using 16bit personal computer and A/D.D/A converter(12bit) is used in order to convert the signal. According to this way, the results from real time control are as follows. 2) Under the On-Off controller with hysterisis the influence of disturbance is considerably smaller than the linerar controller. 3) An increase in the sampling period has a destabilizing effect. 4)In the controller performance, the response time of the On-Off controller is longer than that of the linear controller. To close, we note that the On-Off controller with hysterisis is more attractive than the linear controller in the presence of the input limit.

  • PDF

Switched-voltage control of electrostatic suspension system

  • Woo, Shao-Ju;Jeon, Jong-Up;Higuchi, Toshiro
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1996년도 Proceedings of the Korea Automatic Control Conference, 11th (KACC); Pohang, Korea; 24-26 Oct. 1996
    • /
    • pp.401-404
    • /
    • 1996
  • A new method for the electrostatic suspension of disk-shaped objects is proposed which is based on a switched-voltage control scheme. It operates according to a relay feedback control and deploys only a single high-voltage power supply capable of delivering a dc voltage of positive and/or negative polarity. In addition to the unique feature that no high-voltage amplifiers are needed, this method provides a remarkable system simplification relative to conventional methods. It is shown that despite the inherent limit cycle property of relay feedback based control, an excellent performance in vibration suppression is attained due to the presence of a relatively large squeeze film damping. In this paper, the functional principle of the switched voltage control scheme, numerical analysis, stator electrode design, and a nonlinear dynamic model of the suspension system are described. Experimental results will be presented for a 4-inch silicon wafer that clearly reveal the capability of the proposed control structure to suspend the wafer stably at an airgap length of 50 .mu.m.

  • PDF

최소자승법을 이용한 고속 거리계전 알고리즘 (A High Speed Distance Relaying Algorithm Based on a Least Square Error Method)

  • 강상희;권태원
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제48권7호
    • /
    • pp.855-862
    • /
    • 1999
  • A high speed digital distance relaying algorithm based on a least square error method is proposed. To obtain stable phasor values very quickly, first, a lowpass filter which has very short transient period and no overshoot is presented. Secondly, the least square error method having the data window of 3 samples is used by applying a FIR filter which removes the DC-offset component in current relaying signals. Test results show that the proposed distance relaying algorithm detects most of internal faults within a half cycle after faults in a 154[kV] overhead transmission line system.

  • PDF

시정수를 이용한 직류철도급전계통에서의 고장판단 및 고장점표정 알고리즘 (A Fault Detection and Location Algorithm Using a Time Constant for DC Railway Systems)

  • 양언필;강상희;권영진
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제52권10호
    • /
    • pp.563-570
    • /
    • 2003
  • When a fault occurs on railway feeders it is very important to detect the fault to protect trains and facilities. Because a DC railway system has low feeder voltage, The fault current can be smaller than the current of load starting. So it is important to discriminate between the small fault current and the load starting current. The load starting current increases step by step but the fault current increases at one time. So the type of $\Delta$I/ relay(50F) was developed using the different characteristics between the load starting current and the fault current. The load starting current increases step by step so the time constant of each step is much smaller than that of the fault current. First, to detect faults in DC railway systems, an algorithm using the time constant calculated by the method of least squares is presented in this paper. If a fault occurs on DC railway systems it is necessary to find a fault location to repair the faulted system as soon as possible. The second aim of the paper is to calculate the accurate fault location using Kirchhoff's voltage law.

도시철도 직류 비접지 급전계통에서의 선택 지락보호시스템의 성능평가 (An Evaluation of Selective Grounding Fault Protective Relaying Technique Performance on the Ungrounded DC Traction Power Supply System)

  • 정호성;김주욱;신승권;김형철;안태풍;윤준석
    • 전기학회논문지
    • /
    • 제61권12호
    • /
    • pp.1964-1969
    • /
    • 2012
  • This paper presents to verify the selective grounding fault protective relaying technique for the ungrounded DC traction power supply system. This system selectively blocks fault section when grounding fault occurred. In order to perform this verification, field test facilities have been installed on Oesam substation and Worldcup-Stadium substation, and field test process has been suggested. Also, selective grounding fault protective relaying components and rail voltage reduction device have been tested with the various trial examinations. In order to compare and evaluate performance of the selective grounding fault protective relaying function, field test system was modeled and the system fault simulation results were compared and evaluated with the field test result. Performance of selective grounding fault protective relaying function was evaluated with the above-mentioned process, and the fact that the system recognizes fault section irrespective of insulation between rail and ground and fault resistance from grounding fault.

Individual Charge Equalization Converter with Parallel Primary Winding of Transformer for Series Connected Lithium-Ion Battery Strings in an HEV

  • Kim, Chol-Ho;Park, Hong-Sun;Kim, Chong-Eun;Moon, Gun-Woo;Lee, Joong-Hui
    • Journal of Power Electronics
    • /
    • 제9권3호
    • /
    • pp.472-480
    • /
    • 2009
  • In this paper, a charge equalization converter with parallel-connected primary windings of transformers is proposed. The proposed work effectively balances the voltage among Lithium-Ion battery cells despite each battery cell has low voltage gap compared with its state of charge (SOC). The principle of the proposed work is that the equalizing energy from all battery strings moves to the lowest voltage battery through the isolated dc/dc converter controlled by the corresponding solid state relay switch. For this research a prototype of four Lithium-Ion battery cells is optimally designed and implemented, and experimental results show that the proposed method has excellent cell balancing performance.

DSP를 이용한 원격전력제어 장치 구현 (Implement of a Remote Solid State Power Controller by DSP)

  • 전영철;이혁재;정원용;박영석
    • 한국지능시스템학회논문지
    • /
    • 제20권5호
    • /
    • pp.728-733
    • /
    • 2010
  • 대규모 DC 전력시스템에서는 회로차단기와 계전기로 대표되는 기존의 전자기적 회로 차단기가 산업 전 분야에 널리 이용되고 있다. 최근에는 고 신뢰성, 원격제어능력, 과부화와 단락전류 보호, 적은 열손실 등의 장점을 가지고 있는 원격전력제어기를 MOSFET 반도체 스위칭 소자를 이용하여 개발하고 있는 추세이다. 따라서 원격전력제어기는 고품질을 요구하는 시스템에서 필수적인 부품이 되어가고 있다. 본 논문에서는 원격전력제어장치를 모델링하였고 DSP를 이용하여 과전류 여부를 미리 판단할 수 있는 테스트 환경을 구현하여 최적 신호범위를 산출하였다.

소형전원장치에 대한 통계적 분석 (Statistical analysis for small power module)

  • 신재경
    • Journal of the Korean Data and Information Science Society
    • /
    • 제22권4호
    • /
    • pp.735-740
    • /
    • 2011
  • 최근 전자기기의 소형화, 인텔리전트화, 다기능화, 광대역화에 관심이 집중되어 많은 발전이 이루어졌으며, 이들 전자기기들에 이용되는 모듈형의 전원장치 (SMPS : Switching-mode power supply)도 소형화, 경량화, 고효율화, 고신뢰성화, 저노이즈화를 실현하고 있다. 85~265 볼트교류전압(VAC : Voltage alternating current) 상용 전원을 공급받아 DC 출력을 공급하는 전원장치인 파워모듈은 마이크로컨트롤러, 릴레이 등 전기, 전자 회로용 전원 공급기를 간단하고 쉽게 설계하도록 개발되고 있다. 이 모듈은 전원을 사용하는 장비에 광범위하게 적용할 수 있어 에너지 절감이라는 세계적인 대과제에 적합한 제품이기는 하나 제품의 품질과 성능에 대한 통계적분석이 필요한 바 적용제품의 부하별, 출력전압별 성능분석을 하여 그 문제점을 찾아보려고 한다.

고주파방식 충전기 개발을 위한 페라이트 변압기 설계에 관한 연구 (The Study of the Ferrite Transformer Design for the Development of the High-frequency Battery Charger)

  • 안용호;박종광;김상준;윤장완;윤기웅;한병성
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 하계학술대회 논문집
    • /
    • pp.683-686
    • /
    • 2000
  • The chargers for DC power supply of the contro1lers, which have been installed in the relay rooms in 345/154kV substations of KEPCO, lag in both aspects of technique and performance. Moreover, as they are SCR-based, they dont meet the performance requirements of todays digital and automated controllers. Now two controllers are running in pair and one of those is for reservation. There are lots of troubles because the patrol engineering team has to replace them manually whenever they are out of order. So it is expected to bring convenience if the charger replacement is automated. Also, the existing chargers take much space, weight and cost - which have increased the need of development to make them smaller, less expensive, and have high quality. We will develop a charger system which has one fifth of the weight of the existing system by double-integrating the volume. The new system will be ready for a future full unmanned system with integrated pores for remote control, state-of-the-art digital features, and more than 90% efficiency/power factor against 80% efficiency/power factor of the existing system.

  • PDF