• 제목/요약/키워드: DC protection relay

검색결과 27건 처리시간 0.036초

DC 급전계통 고저항 지락보호에 대한 연구 (A Study on High Impedance Grounding Protection for DC Power Supply System)

  • 이국명;김병현;소선영;김학련
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2006년도 추계학술대회 논문집
    • /
    • pp.878-884
    • /
    • 2006
  • Grounding fault and short of the DC power supply systems are detected and protected by high-speed circuit breaker, linked breaking device, ground relay and fault selective device, all of which are installed and operated in substaions. however, there have been many cases in which the protective devices did not detect grounding of of the over head catenary systems on concrete support for an extended period of time. Such cases often cause severe damages to the supports with high grounding resistances. If grounding accidents occur repetitively, the earth current and the rise of earth potential can damage not only passenger and staff but also electric facilities and equipment, necessitating high cost and endeavor to restore. The following study points out various problems that can be occurred occur as a result of high impedance grounding accident, and proposes a new system which can protect and intercept them.

  • PDF

기동방식을 고려한 DC급전계통 보호알고리즘 (A Protection Algorithm for DC Railway Systems Considering Train Starting)

  • 권영진;최동민;강상희;한문섭;이재경
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 A
    • /
    • pp.307-309
    • /
    • 2004
  • A DC railway system has low feeder voltage, The remote fault current can be smaller than the current of load starting. So it is important to discriminate between the small fault current and the train starting current. The train starting current increases step by step but the fault current increases all at once. So the type of $\bigtriangleup I\;relay(50F)$ was developed using the different characteristics between the load starting current and the fault current. As for the train starting current, the time constant of train current at each step is much smaller than that of the fault current. To detect faults in U railway systems, an algorithm that is independent of train starting current. This algorithm use the time constant calculated by the method of least squares is presented in this paper.

  • PDF

EMTP-RV를 이용한 CT포화 모델링 (EMTP-RV Modeling of CT Saturation)

  • 강용철;최재선;정태영;강해권;장성일;김용균;유영식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.9-11
    • /
    • 2008
  • A protection current transformer (CT) has been widely used for protection devices. When a fault occurs, a CT should provide the faithful reproduction of the primary fault current. However, a CT may saturates due to the magnitude of fault current, dc component primary time constant and the remanent flux of the iron core, and the secondary current of a CT is distorted. The distorted current can cause mal-operation or the operating time delay of a protection relay. This paper provides a modeling of CT saturation using EMTP-RV. The performance of the proposed CT saturation modeling was investigated under various fault conditions varying the fault distance, fault inception angle, and remanent flux of the iron core. The results indicate that the proposed EMTP-RV modeling can operate correctly, and the reasons for CT saturation are verified by EMTP-RV simulations.

  • PDF

EMTDC를 이용한 Digital 보호 알고리즘 검증방법 (The Verification Method of Digital Protective Algorithm Using EMTDC)

  • 이재규;안복신;정병태
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 B
    • /
    • pp.674-676
    • /
    • 1996
  • In this paper, we suggested the verification method of protective algorithms using EMTDC(Electro-Magnetic Transient DC). In other to verify protective algorithms using EMTDC, we first had to make a user defined component and then applied it to a simple power system with parallel line. By means of this method, We reduced the much time and effort to develop or improve the protective algorithm of digital protective relay. For the future, we apply this method to IDPACS(Integrated Digital Protection and Control System) and intend to implement more reliable digital protective relays.

  • PDF

경전철용 LVDC 배전계통의 보호기기 운용 방안에 관한 연구 (A Study on Operation Method of Protection Device for LVDC Distribution Feeder in Light Rail System)

  • 강민관;최성식;이후동;김기영;노대석
    • 한국산학기술학회논문지
    • /
    • 제20권4호
    • /
    • pp.25-34
    • /
    • 2019
  • 최근, 출력전압의 제어가 가능하고 양방향 운용이 가능한 PWM(Pulse Width Modulation) 정류기가 도입되고 있다. 그러나, PWM 정류기가 적용될 경우, 전력계통측에서 사고발생하면, 회생전력에 의한 사고전류 공급으로 기존의 사고전류 크기 및 방향이 바뀔 가능성이 있다. 또한, 경전철용 급전시스템에서는 장거리 지점에서 사고가 발생하는 경우, 사고전류의 크기가 크게 감소되고, 부하전류와 비슷하거나 더 작은 경우가 발생할 수 있기 때문에 이에 대한 적절한 보호협조 운용 방안이 필요한 실정이다. 따라서, 본 논문에서는 상기의 문제점들을 해결하기 위하여, 경전철용 LVDC 배전선로의 보호기기 운용 방안을 제안한다. 구체적으로는 LVDC 배전선로에서의 거리 및 단락저항별 사고특성을 분석하여, 다양한 조건에서 사고를 적절하게 판별하는 직류선택계전기의 보호협조 운용방안을 제안한다. 또한, 배전계통 상용 해석 프로그램인 PSCAD/EMTDC를 이용하여 AC 계통, PWM 정류기, LVDC 배전선로로 구성된 경전철용 급전시스템의 모델링을 제시한다. 한편, 제안한 보호협조 알고리즘과 모델링을 이용하여 LVDC 배전선로의 보호기기 특성을 분석한 결과, 제안한 운용방식에서는 전류 경사각의 급격한 감소를 판정하는 보호요소를 추가한다. 따라서, 사고지점의 단락저항이 높거나 장거리 선로인 경우에도, 보호기기가 사고전류와 부하전류를 적절히 판별할 수 있어, 본 논문에서 제안한 보호협조 운용알고리즘의 유용성을 확인하였다.

전력설비를 위한 디지털보호계전기의 FPGA 구현 (A FPGA Implementation of Digital Protective Relays for Electrical Power Installation)

  • 김종태;신명철
    • 조명전기설비학회논문지
    • /
    • 제19권2호
    • /
    • pp.131-137
    • /
    • 2005
  • 보호계전기는 고장에 의해 파생되는 단락$\cdot$지락 사고로부터 전력 시스템을 보호하기 위하여 널리 사용되고 있다. 전통적으로 디지털보호계전기는 디지털신호처리 프로세서 혹은 마이크로프로세서로 구현되는데 본 연구는 이를 고성능$\cdot$고효율$\cdot$다기능의 단일칩으로 구현하기 위한 하드웨어 설계 기술에 관해 다룬다. 제작된 디지털보호계전기는 FPGA(Field Programmable Gate Array)로 구현하였고 16KSPS이상의 처리 성능을 가지며 평균 오차율 $0.03(\%)$미만으로 보호계전알고리즘을 수행할 수 있다.

최소자승 알고리즘을 이용한 디지털 보호 계전기용 고성능 FIR 필터의 VHDL 모델 설계 (VHDL Design of High Performance FIR Filter for Digital Protection Relay Using Least Square Algorithm)

  • 신재신;김종태;박종강;서종완;신명철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 A
    • /
    • pp.345-347
    • /
    • 2003
  • 본 논문에서는 디지털 보호 계전기에 쓰이는 필터 중에서 최소 자승 알고리즘을 이용한 고성능 FIR 필터를 설계하였다. 기존의 DFT필터와 MATLAB 시뮬레이션을 이용하여 비교하였으며 FIR 필터의 VHDL모델 및 합성에 중점을 두었다. FIR 필터는 기본적으로 유한개의 임펄스 응답이 이루어지기 때문에 기타 다른 필터에 비하여 안정도가 높으며 선형적인 위상을 가지기 때문에 차단 주파수 대역의 왜곡현상을 없앨 수 있는 장점을 가지고 있다. 여러 가지 알고리즘으로 구현한 FIR 필터를 시뮬레이션 한 결과 최소 자승 알고리즘이 가장 우수한 결과를 나타내었다. 기본적으로 디지털 보호 계전기에서 디지털 필터의 기능은 사고 전압, 전류로부터 60Hz의 기본파 추출 CT, PT 왜곡 및 DC offset을 제거하는데 있다. 본 논문에서는 이러한 기능을 가지면서 샘플링 주파수와 차수를 같게 하여 FIR 필터와 DFT 필터의 주파수 응답과 연 산 속도를 비교 하였다. 본 논문에서 설계된 최소 자승 알고리즘을 이용한 FIR 필터는 같은 조건의 DFT필터에 비해 1고조파와 2고조파의 차이가 10db 이상 더 우수 하였으며 연산 속도 또한 2배 이상 좋은 결과를 보였다.

  • PDF