• Title/Summary/Keyword: DC potential

Search Result 373, Processing Time 0.03 seconds

Measurement of plasma potential by a biased cut off probe

  • Kim, Dae-Ung;Kim, Jeong-Hyeong;Seong, Dae-Jin;Yu, Sin-Jae;Jang, Hong-Yeong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.02a
    • /
    • pp.465-465
    • /
    • 2010
  • Cut off probe, the efficient method, can measure the plasma parameters like the plasma electron density and the electron temperature. Plasma potential is also one of the important parameters in plasma processing but cannot be measured by cut off probe yet. Thus we developed method to measure plasma potential by focusing on relation between bias on a tip and sheath around tip. The system consist of a ICP(Inductive Coupled Plasma) source, a Network analyzer and a bias tee that can be bridge apply DC voltage on the cut off probe tip. Plasma potential is identified by using this system. The results corresponded well with the measured results by single langmuir probe(SLP).

  • PDF

Simultaneous uptake of arsenic and lead using Chinese brake ferns (Pteris vittata) with EDTA and electrodics

  • Butcher, David J.;Lim, Jae-Min
    • Analytical Science and Technology
    • /
    • v.32 no.1
    • /
    • pp.1-6
    • /
    • 2019
  • Chinese brake fern (Pteris vittata) has potential for application in the phytoremediation of arsenic introduced by lead arsenate-based pesticides. In this study, Chinese brake ferns were used to extract arsenic, mainly in field and greenhouse experiments, and to assess the performance of simultaneous phytoaccumulation of arsenic and lead from homogenized soil in the greenhouse, with the application of EDTA and electric potential. The ferns have been shown to be effective in accumulating high concentrations of arsenic, and extracting both arsenic and lead from the contaminated soil, with the addition of a chelating agent, EDTA. The maximum increase in lead accumulation in the ferns was 9.2 fold, with a 10 mmol/kg addition of EDTA. In addition, the application of EDTA in combination with electric potential increased the lead accumulation in ferns by 10.6 fold at 5 mmol/kg of EDTA and 40 V (dc), compared to controls. Therefore, under application of EDTA and electric potential, Chinese brake fern is able to extract arsenic and lead simultaneously from soil contaminated by lead arsenate.

Antibacterial Activity of Essential Oils from Zanthoxylum piperitum A.P. DC. and Zanthoxylum schinifolium

  • Choi, Soo-Im;Chang, Kyung-Mi;Lee, Yong-Soo;Kim, Gun-Hee
    • Food Science and Biotechnology
    • /
    • v.17 no.1
    • /
    • pp.195-198
    • /
    • 2008
  • This study was carried out to investigate the potential use of Zanthoxylum schinifolium and Zanthoxylum piperitum A.P. DC. as a source of antimicrobial agents against food borne pathogens. Essential oils of Z. schinifolium and Z. piperitum A.P. DC. were collected by steam distillation and analyzed by GC-MS. The antimicrobial activity of the essential oils was examined using the agar diffusion and micro-dilution assays. The effectiveness of Z. schinifolium essential oil was greater against Bacillus cereus, Staphylococcus aureus, and Vibrio parahaemolyticus than other pathogens, and the minimal inhibitory concentration (MIC) values were 1.25, 2.5, and 1.25, 2.5, and $1.25\;{\mu}g/mL$, respectively. Z. piperitum A.P. DC. essential oil was the most effective against all pathogens tested except for Escherichia coli O157:H7, and the MIC values against B. cereus, Salmonella choleraesuis, and V. parahaemolyticus were 1.25, 2.5, and $1.25\;{\mu}g/mL$, respectively. Limonene, the major component of Z. piperitum A.P. DC. essential oils, had the highest inhibitory activity toward V. parahaemolyticus with a MIC value of $0.15\;{\mu}g/mL$. Meanwhile, citronellal and geranyl acetate, major components of both essential oils, displayed antibacterial activity against only B. cereus with MIC values of 1.25 and $5\;{\mu}g/mL$, respectively. Therefore, these essential oils could be useful as antimicrobial agents against foodborne pathogens.

The Risk Factors for Hydrocephalus and Subdural Hygroma after Decompressive Craniectomy in Head Injured Patients

  • Ki, Hee Jong;Lee, Hyung-Jin;Lee, Hong-Jae;Yi, Jin-Seok;Yang, Ji-Ho;Lee, Il-Woo
    • Journal of Korean Neurosurgical Society
    • /
    • v.58 no.3
    • /
    • pp.254-261
    • /
    • 2015
  • Objective : The present study aims to investigate 1) the risk factors for hydrocephalus and subdural hygroma (SDG) occurring after decompressive craniectomy (DC), and 2) the association between the type of SDG and hydrocephalus. Methods : We retrospectively reviewed the clinical and radiological features of 92 patients who underwent DC procedures after severe head injuries. The risk factors for developing post-traumatic hydrocephalus (PTH) and SDG were analyzed. Types of SDGs were classified according to location and their relationship with hydrocephalus was investigated. Results : Ultimately, 26.09% (24/92) of these patients developed PTH. In the univariate analyses, hydrocephalus was statically associated with large bone flap diameter, large craniectomy area, bilateral craniectomy, intraventricular hemorrhage, contralateral or interhemisheric SDGs, and delayed cranioplasty. However, in the multivariate analysis, only large craniectomy area (adjusted OR=4.66; p=0.0239) and contralateral SDG (adjusted OR=6.62; p=0.0105) were significant independent risk factors for developing hydrocephalus after DC. The incidence of overall SDGs after DC was 55.43% (51/92). Subgroup analysis results were separated by SDG types. Statistically significant associations between hydrocephalus were found in multivariate analysis in the contralateral (adjusted OR=5.58; p=0.0074) and interhemispheric (adjusted OR=17.63; p=0.0113) types. Conclusion : For patients who are subjected to DC following severe head trauma, hydrocephalus is associated with a large craniectomy area and contralateral SDG. For SDGs after DC that occur on the interhemispherical or controlateral side of the craniectomy, careful follow-up monitoring for the potential progression into hydrocephalus is needed.

Field Test of Mitigation Methods for Stray Currents from DC Electric Railroad(2) Rapid Potential-Controlled Rectifier (직류전기철도 전식대책 실증실험(2) 속응형 정전위 정류기)

  • Ha, Yoon-Cheol;Ha, Tae-Hyun;Bae, Jeong-Hyo;Lee, Hyun-Goo;Kim, Dae-Kyeong;Choi, Jeong-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2007.10c
    • /
    • pp.217-219
    • /
    • 2007
  • With the wide spread of direct current(DC) electric railroads in Korea, the stray current or leakage currents from negative return rails become a pending problem to the safety of nearby underground Infrastructures. The most widely used mitigation method for this interference is the stray current drainage method, which connects the underground metallic structures to the rails with diodes (polarized drainage) or thyristor (forced drainage). This method, however, inherently possesses some drawbacks such as an increase of total leakage torrents from rails, expansion of interference zone, etc. In order to resolve these drawbacks, we developed a rapid potential-controled rectifier and applied to a depot area where stray current inference is very severe. The effect of this method was analyzed from the field tell data and we suggest this method can be an excellent alternative to the drainage-bond-based mitigation methods.

  • PDF

A Study on Elevated Temperature Fatigue Crack Growth Using Round Bar Specimen with a Surface Crack (표면균열을 갖는 원형봉재 시편을 이용한 고온 피로균열성장 연구)

  • So, Tae-Won;Yun, Gi-Bong
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.20 no.11
    • /
    • pp.3415-3423
    • /
    • 1996
  • The compact tension specimen geometry has been widely used for measuring fatigue crack growth rates at elevated temperature when the fatigue load is under tension/tension condition. However, most of the elevated temperature components which have significant crack growth life experience fatigue load under tension/compression conditions. Thus test techniques are required since the compact tension specimen cannot be used for tension/compression loading. In this paper, a simplified test procedure for measureing fatigue crack growth rates is proposed, which employs a round bar specimen with a small surface crack. Fatigue crack growth rates under tension/ tension loading conditions at elevated temperature were measured according to the proposed procedure and compared with those previously measured by C/(T) specimens. Since both the measured crack growth rates were comparable, the fatigue crack growth rates under tension/ compression load can be reliably measured by the proposed procedure. For monitoring crack depth. DC electric potential method is employed and an optimal probe location and current input conditions were proposed.

Corrosion Fatigue Characteristics of A106-GrB Steel Weldments in NaC1 solution (A106 GrB강 용접부의 염수중 부식피로특성)

  • 김철한
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.6 no.3
    • /
    • pp.65-72
    • /
    • 1997
  • The horizontal corrosion fatigue tester has been developed for investigating environmental strength. Using this tester, we investigated about corrosion fatigue caracteristics for A106-Gr B steel weldments in 3.5% synthetic seawater and room temperature. Considered parameter is only frequency of 1, 3 and 5Hz.. and Corrosion fatigue crack length was measured by DC potential difference method. From the results, we could find that the horizontal corrosion fatigue tester could be well applied to estimation of fatigue strength. and, In case of 5Hz., corrosion fatigue crack growth pate of A106-Gr B steel weldment was transgranular, and of 1 and 3Hz. showed that transgranular and interfranular was mixed. Also, Material constants of corrosion fatigue crack growth estimated in each frequency were C=9.33$\times$$10^{-9}$ and m=2.93 in 1Hz., C=9.77$\times$$10^{-10}$ and m=3.47 in 3Hz., C=1.02$\times$$10^{-10}$ and m=4.05 in 5Hz

  • PDF

Implementation of EPS Motion Signal Detection and Classification system Based on LabVIEW (LabVIEW 기반 EPS 동작신호 검출 및 분석 시스템 구현)

  • Cheon, Woo Young;Lee, Suk Hyun;Kim, Young Chul
    • Smart Media Journal
    • /
    • v.5 no.3
    • /
    • pp.25-29
    • /
    • 2016
  • This paper presents research for non-contact gesture recognition system using EPS(Electronic Potential Sensor) for measuring the human body of electromagnetic fields. It implemented a signal acquisition and signal processing system for designing a system suitable for motion recognition using the data coming from the sensors. we transform AC-type data into DC-type data by applying a 10Hz LPF considering H/W sampling rate. in addition, we extract 2-dimensional movement information by taking difference value between two cross-diagonal deployed sensor.

A Study of Discharge Shape Changes by Magnet Arrangements in a Magnetron Cathode (마그네트론 음극의 자석 배열에 따른 방전의 형상 변화 연구)

  • Jee, Jung-Eun;Joo, Jung-Hoon
    • Journal of Surface Science and Engineering
    • /
    • v.41 no.3
    • /
    • pp.94-101
    • /
    • 2008
  • A new convenient magnet array module is designed to investigate effects of magnetic field array on magnetron discharge characteristics. Magnetic field analysis showed good agreement of measured discharge region by a CCD device which has a high quantum efficiency over visible wavelength range. OES (optical emission spectroscopy) showed major emission peaks are from electronic transitions in 400 nm range and 800 nm range. Effects of driving voltage characteristics were analyzed in a point of electron drift trajectories and ionizing collision frequencies. Pulsed dc with a fast rising and falling time was analyzed to have potential to increase ionization collisions by putting a burst of hot electrons and to raise sheath potential. From measured voltage and current waveform, maximum of -1000 V peak was generated with $-400\;V_{rms}$ conditions. Possibility of a properly designed magnetron cathode was shown to be used as a melting device. Cu was successfully melted with power density of a several tens of $W/cm^2$.

EMC Safety Margin Verification for GEO-KOMPSAT Pyrotechnic Systems

  • Koo, Ja-Chun
    • International Journal of Aerospace System Engineering
    • /
    • v.9 no.1
    • /
    • pp.1-15
    • /
    • 2022
  • Pyrotechnic initiators provide a source of pyrotechnic energy used to initiate a variety of space mechanisms. Pyrotechnic systems build in electromagnetic environment that may lead to critical or catastrophic hazards. Special precautions are need to prevent a pulse large enough to trigger the initiator from appearing in the pyrotechnic firing circuits at any but the desired time. The EMC verification shall be shown by analysis or test that the pyrotechnic systems meets the requirements of inadvertent activation. The MIL-STD-1576 and two range safeties, AFSPC and CSG, require the safety margin for electromagnetic potential hazards to pyrotechnic systems to a level at least 20 dB below the maximum no-fire power of the EED. The PC23 is equivalent to NASA standard initiator and the 1EPWH100 squib is ESA standard initiator. This paper verifies the two safety margins for electromagnetic potential hazards. The first is verified by analyzing against a RF power. The second is verified by testing against a DC current. The EMC safety margin requirement against RF power has been demonstrated through the electric field coupling analysis in differential mode with 21 dB both PC23 and 1EPWH100, and in common mode with 58 dB for PC23 and 48 dB for 1EPWH100 against the maximum no-fire power of the EED. Also, the EMC safety margin requirement against DC current has been demonstrated through the electrical isolation test for the pyrotechnic firing circuits with greater than 20 dB below the maximum no-fire current of the EED.