• Title/Summary/Keyword: DC method

Search Result 3,469, Processing Time 0.038 seconds

Study on the fabrication of a polycrystalline silicon (pc-Si) seed layer for the pc-Si lamelliform solar cell (다결정 실리콘 박형 태양전지를 위한 다결정 실리콘 씨앗층 제조 연구)

  • Jeong, Hyejeong;Oh, Kwang H.;Lee, Jong Ho;Boo, Seongjae
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.75.2-75.2
    • /
    • 2010
  • We studied the fabrication of polycrystalline silicon (pc-Si) films as seed layers for application of pc-Si thin film solar cells, in which amorphous silicon (a-Si) films in a structure of glass/Al/$Al_2O_3$/a-Si are crystallized by the aluminum-induced layer exchange (ALILE) process. The properties of pc-Si films formed by the ALILE process are strongly determined by the oxide layer as well as the various process parameters like annealing temperature, time, etc. In this study, the effects of the oxide film thickness on the crystallization of a-Si in the ALILE process, where the thickness of $Al_2O_3$ layer was varied from 4 to 50 nm. For preparation of the experimental film structure, aluminum (~300 nm thickness) and a-Si (~300 nm thickness) layers were deposited using DC sputtering and PECVD method, respectively, and $Al_2O_3$ layer with the various thicknesses by RF sputtering. The crystallization of a-Si was then carried out by the thermal annealing process using a furnace with the in-situ microscope. The characteristics of the produced pc-Si films were analyzed by optical microscope (OM), scanning electron microscope (SEM), Raman spectrometer, and X-ray diffractometer (XRD). As results, the crystallinity was exponentially decayed with the increase of $Al_2O_3$ thickness and the grain size showed the similar tendency. The maximum pc-Si grain size fabricated by ALILE process was about $45{\mu}m$ at the $Al_2O_3$ layer thickness of 4 nm. The preferential crystal orientation was <111> and more dominant with the thinner $Al_2O_3$ layer. In summary, we obtained a pc-Si film not only with ${\sim}45{\mu}m$ grain size but also with the crystallinity of about 75% at 4 nm $Al_2O_3$ layer thickness by ALILE process with the structure of a glass/Al/$Al_2O_3$/a-Si.

  • PDF

Sol-Gel Synthesis, Crystal Structure, Magnetic and Optical Properties in ZnCo2O3 Oxide

  • Das, Bidhu Bhusan;Barman, Bittesh
    • Journal of the Korean Chemical Society
    • /
    • v.63 no.6
    • /
    • pp.453-458
    • /
    • 2019
  • Synthesis of ZnCo2O3 oxide is performed by sol-gel method via nitrate-citrate route. Powder X-ray diffraction (XRD) study shows monoclinic unit cell having lattice parameters: a = 5.721(1) Å, b = 8.073(2) Å, c = 5.670(1) Å, β = 93.221(8)°, space group P2/m and Z = 4. Average crystallite sizes determined by Scherrer equation are the range ~14-32 nm, whereas SEM micrographs show nano-micro meter size particles formed in ZnCo2O3. Endothermic peak at ~798 K in the Differential scanning calorimetric (DSC) trace without weight loss could be due to structural transformation and the endothermic peak ~1143 K with weight loss is due to reversible loss of O2 in air atmosphere. Energy Dispersive X-ray (EDX) analysis profile shows the presence of elements Zn, Co and O which indicates the purity of the sample. Magnetic measurements in the range of +12 kOe to -12 kOe at 10 K, 77 K, 120 K and at 300 K by PPMS-II Physical Property Measurement System (PPMS) shows hysteresis loops having very low values of the coercivity and retentivity which indicates the weakly ferromagnetic nature of the oxide. Observed X-band EPR isotropic lineshapes at 300 K and 77 K show positive g-shift at giso ~2.230 and giso ~2.217, respectively which is in agreement with the presence of paramagnetic site Co2+(3d7) in the oxide. DC conductivity value of 2.875 ×10-8 S/cm indicates very weakly semiconducting nature of ZnCo2O3 at 300 K. DRS absorption bands ~357 nm, ~572 nm, ~619 nm and ~654 nm are due to the d-d transitions 4T1g(4F)→2Eg(2G), 4T1g(4F)→4T1g(4P), 4T1g(4F)→4A2g(4F), 4T1g(4F)→4T2g(4F), respectively in octahedral ligand field around Co2+ ions. Direct band gap energy, Eg~ 1.5 eV in the oxide is obtained by extrapolating the linear part of the Tauc plot to the energy axis indicates fairly strong semiconducting nature of ZnCo2O3.

Electrochemical treatment of wastewater using boron doped diamond electrode by metal inter layer

  • KIM, Seohan;YOU, Miyoung;SONG, Pungkeun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.251-251
    • /
    • 2016
  • For several decades, industrial processes consume a huge amount of raw water for various objects that consequently results in the generation of large amounts of wastewater. Wastewaters are consisting of complex mixture of different inorganic and organic compounds and some of them can be toxic, hazardous and hard to degrade. These effluents are mainly treated by conventional technologies such are aerobic and anaerobic treatment and chemical coagulation. But, these processes are not suitable for eliminating all hazardous chemical compounds form wastewater and generate a large amount of toxic sludge. Therefore, other processes have been studied and applied together with these techniques to enhance purification results. These include photocatalysis, absorption, advanced oxidation processes, and ozonation, but also have their own drawbacks. In recent years, electrochemical techniques have received attention as wastewater treatment process that could be show higher purification results. Among them, boron doped diamond (BDD) attract attention as electrochemical electrode due to good chemical and electrochemical stability, long lifetime and wide potential window that necessary properties for anode electrode. So, there are many researches about high quality BDD on Nb, Ta, W and Si substrates, but, their application in effluents treatment is not suitable due to high cost of metal and low conductivity of Si. To solve these problems, Ti has been candidate as substrate in consideration of cost and property. But there are adhesion issues that must be overcome to apply Ti as BDD substrate. Al, Cu, Ti and Nb thin films were deposited on Ti substrate to improve adhesion between substrate and BDD thin film. In this paper, BDD films were deposited by hot filament chemical vapor deposition (HF-CVD) method. Prior to deposition, cleaning processes were conducted in acetone, ethanol, and isopropyl alcohol (IPA) using sonification machine for 7 min, respectively. And metal layer with the thickness of 200 nm were deposited by DC magnetron sputtering (DCMS). To analyze microstructure X-ray diffraction (XRD, Bruker gads) and field emission scanning electron microscopy (FE-SEM, Hitachi) were used. It is confirmed that metal layer was effective to adhesion property and improved electrode property. Electrochemical measurements were carried out in a three electrode electrochemical cell containing a 0.5 % H2SO4 in deionized water. As a result, it is confirmed that metal inter layer heavily effect on BDD property by improving adhesion property due to suppressing formation of titanium carbide.

  • PDF

Decomposition Process of CFC by Thermal Plasma (열플라즈마에 의한 CFC의 분해공정)

  • Cha, Woo-Byoung;Choi, Kyung-Soo;Park, Dong-Wha
    • Applied Chemistry for Engineering
    • /
    • v.9 no.6
    • /
    • pp.829-834
    • /
    • 1998
  • Concerned with environmental issue, a new decomposition method for CFCs that caused the destruction of ozone layer was proposed. Using thermal plasma process, CFC113 decomposed completely. In order to quantify the tendency in decomposition and recombination of CFC113, thermodynamic equilibrium calculations were performed. The calculation was conducted with CFC113, $H_2$, $O_2$ at 1 atm and 300 K~5000 K. In the experiment, products which are generated after decomposition in the plasma were examined by varying reacting gases($H_2$, $O_2$) flow rates and the changes of inside diameters of quenching tubes. Decomposition products were analyzed using Gas Chromatograph. The results are very promising with a decomposition efficiency greater than 99.99%. As to CFC113/$H_2$=1/3, conversion to CO decreased with increasing $O_2$ ratio. When CFC113/$O_2$=1/1, 1/1.5 and 1/2, conversion to CO increases above $H_2$ ratio of 3. The change of CO conversion is not sensitive to power changes. As total flow rate increased, CO conversion was slightly decreased. When the inside diameter of the quenching tube was changed from 8mm into 4mm, CO conversion was increased due to enhanced quenching rate.

  • PDF

Electrochemical Characteristics of Zn and Si Ion-doped HA Films on Ti-6Al-4V by PEO Treatment

  • Lim, Sang-Gyu;Hwang, In-Jo;Choe, Han-Cheol
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2016.11a
    • /
    • pp.199-199
    • /
    • 2016
  • Commercially pure titanium (cp-Ti) and Ti alloys (typically Ti-6Al-4V) display excellent corrosion resistance and biocompatibility. Although the chemical composition and topography are considered important, the mechanical properties of the material and the loading conditions in the host have, conventionally. Ti and its alloys are not bioactive. Therefore, they do not chemically bond to the bone, whereas they physically bond with bone tissue. The electrochemical deposition process provides an effective surface for biocompatibility because large surface area can be served to cell proliferation. Electrochemical deposition method is an attractive technique for the deposition of hydroxyapatite (HAp). However, the adhesions of these coatings to the Ti surface needs to be improved for clinical used. Plasma electrolyte oxidation (PEO) enables control in the chemical com position, porous structure, and thickness of the $TiO_2$ layer on Ti surface. In addition, previous studies h ave concluded that the presence of $Ca^{+2}$ and ${PO_4}^{3-}$ ion coating on porous $TiO_2$ surface induced adhesion strength between HAp and Ti surface during electrochemical deposition. Silicon (Si) in particular has been found to be essential for normal bone and cartilage growth and development. Zinc (Zn) plays very important roles in bone formation and immune system regulation, and is also the most abundant trace element in bone. The objective of this work was to study electrochemical characteristcs of Zn and Si coating on Ti-6Al-4V by PEO treatment. The coating process involves two steps: 1) formation of porous $TiO_2$ on Ti-6Al-4V at high potential. A pulsed DC power supply was employed. 2) Electrochemical tests were carried out using potentiodynamic and AC impedance methoeds. The morphology, the chemical composition, and the micro-structure an alysis of the sample were examined using FE-SEM, EDS, and XRD. The enhancements of the HAp forming ability arise from $Si/Zn-TiO_2$ surface, which has formed the reduction of the Si/Zn ions. The promising results successfully demonstrate the immense potential of $Si/Zn-TiO_2$ coatings in dental and biomaterials applications.

  • PDF

Trace impurity analysis of Cu films using GDMS: concentration change of impurities by applying negative substrate bias voltage (글로우방전 질량분석법을 이용한 구리 박막내의 미량불순물 분석: 음의 기판 바이어스에 의한 불순물원소의 농도변화)

  • Lim Jae-Won;Isshiki Minoru
    • Journal of the Korean Vacuum Society
    • /
    • v.14 no.1
    • /
    • pp.17-23
    • /
    • 2005
  • Glow discharge mass spectrometry(GDMS) was used to determine the impurity concentrations of the deposited Cu films and the 6N Cu target. Cu films were deposited on Si (100) substrates at zero substrate bias voltage and a substrate bias voltage of -50 V using a non-mass separated ion beam deposition method. Since do GDMS has a little difficulty to apply to thin films because of the accompanying non-conducting substrate, we have used an aluminum foil to cover the edge of the Cu film in order to make an electrical contact of the Cu film deposited on the non-conducting substrate. As a result, the Cu film deposited at the substrate bias voltage of -50 V showed lower impurity contents than the Cu film deposited without the substrate bias voltage although both the Cu films were contaminated during the deposition. It was found that the concentration change of each impurity in the Cu films by applying the negative substrate bias voltage is related to the difference in their ionization potentials. The purification effect by applying the negative substrate bias voltage might result from the following reasons: 1) Penning ionization and an ionization mechanism proposed in the present study, 2) difference in the kinetic energy of accelerated Cu+ ions toward the substrate with/without the negative substrate bias voltage.

Effect of Cathode Porosity of Mixed Conducting (La0.6Sr0.4Co0.2Fe0.8O3) on the Power Generating Characteristics of Anode Supported SOFCs (혼합전도체 LSCF(La0.6Sr0.4Co0.2Fe0.8O3) 양극의 기공률에 따른 음극지지형 단전지의 출력특성 평가)

  • Yun, Joong-Cheul;Kim, Woo-Sik;Kim, Hyoungchul;Lee, Jong-Ho;Kim, Joosun;Lee, Hae-Weon;Kim, Byong-Ho
    • Journal of the Korean Ceramic Society
    • /
    • v.42 no.4
    • /
    • pp.269-275
    • /
    • 2005
  • We analyzed the unit cell performance against the cathode porosity, which is supposed to be closely related with active sites for the cathode reaction. In order to fabricate the unit cells with different porosity in the cathode layer we changed the mixing ratio of fine and coarse LSCF cathode powders. The final porosity of each cathode layer was 14, 23, 27, $39\%$ respectively. According to the electrochemical analysis of unit cell performance via DC current interruption and AC impedance method, the electrodic polarization resistance was diminished as the cathode porosity increased. The decrease of polarization resistance was attributed due to the increase of active reaction sites and the enhancement of overall unit cell performance could be explained in the same line.

Plant-wide On-line Monitoring and Diagnosis Based on Hierarchical Decomposition and Principal Component Analysis (계층적 분해 방법과 PCA를 이용한 공장규모 실시간 감시 및 진단)

  • Cho Hyun-Woo;Han Chong-hun
    • Journal of the Korean Institute of Gas
    • /
    • v.1 no.1
    • /
    • pp.27-32
    • /
    • 1997
  • Continual monitoring of abnormal operating conditions i a key issue in maintaining high product quality and safe operation, since the undetected process abnormality may lead to the undesirable operations, finally producing low quality products, or breakdown of equipment. The statistical projection method recently highlighted has the advantage of easily building reference model with the historical measurement data in the statistically in-control state and not requiring any detailed mathematical model or knowledge-base of process. As the complexity of process increases, however, we have more measurement variables and recycle streams. This situation may not only result in the frequent occurrence of process Perturbation, but make it difficult to pinpoint trouble-making causes or at most assignable source unit due to the confusing candidates. Consequently, an ad hoc skill to monitor and diagnose in plat-wide scale is needed. In this paper, we propose a hierarchical plant-wide monitoring methodology based on hierarchical decomposition and principal component analysis for handling the complexity and interactions among process units. This have the effect of preventing special events in a specific sub-block from propagating to other sub-blocks or at least delaying the transfer of undesired state, and so make it possible to quickly detect and diagnose the process malfunctions. To prove the performance of the proposed methodology, we simulate the Tennessee Eastman benchmark process which is operated continuously with 41 measurement variables of five major units. Simulation results have shown that the proposed methodology offers a fast and reliable monitoring and diagnosis for a large scale chemical plant.

  • PDF

Effect of Improved Forelimb Sensorimotor Function on the Transcranial Direct Current Stimulation in a Focal Ischemic Brain Injury Rat Model (국소 허혈성 뇌손상 흰쥐 모델에서 경두개직류전기자극이 앞다리 운동감각 기능 증진에 미치는 효과)

  • Kim, Gi-Do;Sim, Ki-Cheol;Kim, Kyung-Yoon
    • The Journal of the Korea Contents Association
    • /
    • v.11 no.4
    • /
    • pp.273-282
    • /
    • 2011
  • This study was to investigate the effect of improve forelimb sensorimotor function and neurotrophic factor(GAP-43) expression when differing an application time of tDCS in ischemic brain injury rat model(pre, $1^{st}$, $7^{th}$, $14^{th}$). Focal ischemic brain injury was induced in 80 Sprague-Dawley rats through middle cerebral artery occlusion(MCAO) by 'Longa' method. And then experimental groups were randomly divided into four groups; GroupI: MCAO induction, GroupII: application of tDCS(10 min) after MCAO induction, GroupIII: application of tDCS(20 min) after MCAO induction, GroupIV: application of tDCS(30 min) after MCAO induction. Modified limb placing test and single pellet reaching test were performed to test forelimb sensorimotor function. And the histological examination was also observed through the immunohistochemistric response of GAP-43(growth-associated protein-43) in the cerebral cortex. In modified limb placing test, groupIII(p<0.05) showed significantly improve than the other groups on $14^{th}$). day. In single pellet reaching test, groupIII(p<0.01) and groupIV(p<0.05) significantly improved on $14^{th}$) day. And in immunohistochemistric response of GAP-43, group III showed significantly positive response than the other groups on $14^{th}$ day. These results suggest that the intensity(0.1 mA)/time(20 min) condition of tDCS application has a significant impact on the sensorimotor functional recovery in focal ischemic brain injury rat models.

A Study on the Accelerated Life Test of BLDC Motor in Ceiling Mounted Digital Signage Rotating System (천정 거치형 디지털 사이니지 회전 시스템의 BLDC모터 가속수명시험에 관한 연구)

  • Kim, Ki-Hong;Kwon, Soon-Hong;Kwon, Soon-Gu;Park, Jong-Min;Kim, Jong-Soon;Jung, Sung-Won;Choi, Won-Sik
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.21 no.3
    • /
    • pp.141-147
    • /
    • 2018
  • In a time when product development cycles are getting shorter and shorter, many companies are making efforts to develop products with high reliability in a short period of time, accelerated life test is widely used as a method to quickly evaluate reliability. Accelerated life test reduces the test life or the life of the product from the observed data by shortening the lifetime of the product or abruptly lowering the performance under the worse condition than the actual condition in order to shorten the test cost or the test time. In this paper, BL3640A-06P+RB35, DC12V model, which is used in the support device of an automatic rotation type digital signage, which display various information such as textures and images on a display screen in a public place or a commercial space, BLDC motors were subjected to a constant stress test and at the rotational speed of 1rpm, $180^{\circ}$ rotation and reverse rotation under actual use conditions, the stress was imposed on the rotating speed of 2rpm and the weight of the actual installed product from 22.2kgf to 10kgf were installed. The lifetime of the actual use environment condition is 23,545 hours and the rotation speed is accelerated. The life time of the acceleration condition with the additional weight is 1,380 hours. The acceleration factor is calculated as 17.06, the one year guarantee test day is 235 days to 14 days, of the period from 470 days to 28 days, and the third year from 704 days to 42 days. The test date of the BLDC motor was tested on the shortened test date, and the rotational speed and the current value were measured. It is found that there is no defect even if it operates as the test date corresponding to the specified one year warranty period and the 3 year accelerated life test which is experimented. Using the statistical technique of the regression analysis the expected time for the motor to defect to #4 samples was 20 years.