• Title/Summary/Keyword: DC link inverter

Search Result 449, Processing Time 0.03 seconds

Non-equal DC link Voltages in a Cascaded H-Bridge with a Selective Harmonic Mitigation-PWM Technique Based on the Fundamental Switching Frequency

  • Moeini, Amirhossein;Iman-Eini, Hossein;Najjar, Mohammad
    • Journal of Power Electronics
    • /
    • v.17 no.1
    • /
    • pp.106-114
    • /
    • 2017
  • In this paper, the Selective Harmonic Mitigation-PWM (SHM-PWM) method is used in single-phase and three-phase Cascaded H-Bridge (CHB) inverters in order to fulfill different power quality standards such as EN 50160, CIGRE WG 36-05, IEC 61000-3-6 and IEC 61000-2-12. Non-equal DC link voltages are used to increase the degrees of freedom for the proposed SHM-PWM technique. In addition, it will be shown that the obtained solutions become continuous and without sudden changes. As a result, the look-up tables can be significantly reduced. The proposed three-phase modulation method can mitigate up to the 50th harmonic from the output voltage, while each switch has just one switching in a fundamental period. In other words, the switching frequency of the power switches are limited to 50 Hz, which is the lowest switching frequency that can be achieved in the multilevel converters, when the optimal selective harmonic mitigation method is employed. In single-phase mode, the proposed method can successfully mitigate harmonics up to the 50th, where the switching frequency is 150 Hz. Finally, the validity of the proposed method is verified by simulations and experiments on a 9-level CHB inverter.

A 2nd Order Harmonic Compensation Method for Wind Power System Using a PR Controller

  • Jeong, Hae-Gwang;Lee, Jong-Hyun;Lee, Kyo-Beum
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.3
    • /
    • pp.507-515
    • /
    • 2013
  • This paper proposes a compensation method for the $2^{nd}$-order harmonic of single-phase grid-connected wind power generation systems. Theoretically, a single-phase grid-connected inverter system has no choice but to cause the $2^{nd}$-order harmonic to DC-link voltage. The reference active current is affected by the DC-link voltage. The output current from the reference active current is distorted by the $1^{st}$ and $3^{rd}$-order harmonic. The proposed method can compensate, conveniently, the reference active current with the $2^{nd}$-order harmonic. To reduce the $2^{nd}$-order ripple in the reference active current, proposed method takes a PR controller as a feed-forward compensator. PR controllers can implement selective harmonic compensation without excessive computational requirements; the use of these controllers simplifies the method. Both the simulation and experimental results agree well with the theoretical analysis.

Algorithm on the power Cell AVR(Auto Voltage Regulation) of H-Bridge Multi-level Inverter (H-bridge 멀티-레벨 인버터의 파워Cell AVR에 관한 알고리즘)

  • Jeon, J.H.;Yun, H.M.;Kim, M.K.;Lee, J.P.;Jang, D.J.;Na, S.H.;Kwon, B.H.
    • Proceedings of the KIPE Conference
    • /
    • 2005.07a
    • /
    • pp.317-320
    • /
    • 2005
  • 본 논문은 멀티-레벨 H-bridge 인버터에서 입력전압 변동에 따른 AVR(Auto Voltage Regulation)기능을 적용 그 타당성을 제안하였다. 기존의 범용 인버터에서 (V/F)로 구동되는 전동기 시스템에 있어서 인버터에 공급되는 입력 전압은 출력 주파수에 따라 출력 전압 비율을 일정하게 하고 기동에 필요한 전압을 더하여 출력하는 방식이다. 집중 제어 방식의 멀티-레벨 H-bridge 인버터에서는 Cell의 DC-Link 전압을 Master에서 받아들여서 각각의 Cell에 기준 전압값을 지령하게 된다. 그러므로 입력 전압 변동에 따른 DC-Link 전압의 변동이 발생하게 되면 상전압 Unbalance 가 발생하게 되어 부하가 원하는 출력 전압을 낼 수가 없게 된다. 또한 각각의 Cell을 제어하는 Master 제어기가 가지고 있는 문제점을 보완하여 각각의 Cell 제어기 스스로가 AVR을 수행하는 좀더 나은 방법을 제안하였다.

  • PDF

Duplex Pulse Frequency Modulation Mode Controlled Series Resonant High Voltage Converter for X-Ray Power Generator

  • Chu Enhui;Ogura Koki;Moisseev Serguei;Okuno Atsushi;Nakaoka Mutsuo
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.295-300
    • /
    • 2001
  • A variety of high voltage DC power supplies employing the high frequency inverter are difficult to achieve soft switching considering a quick response and no overshoot response under the wide load variation ranges which are used in medical-use x-ray high voltage generator from 20kV to 150kV in the output voltage and from 0.5mA to 1250mA, respectively. The authors develops soft switching high voltage DC power supply designed for x-ray power generator applications, which uses series resonant inverter circuit topology with a multistage voltage multiplier instead of a conventional high voltage diode rectifier connected to the second-side of a high-voltage transformer with a large turn ratio. A constant on-time dual mode frequency control scheme operating under a principle of zero-current soft switching commutation is described. Introducing the multistage voltage multiplier, the secondary transformer turn-numbers and stray capacitance of high-voltage transformer is effective to be greatly reduced. It is proved that the proposed high-voltage converter topology with dual mode frequency modulation mode control scheme is able to be the transient response and steady-state performance in high-voltage x-ray tube load. The effectiveness of this high voltage converter is evaluated and discussed on the basis of simulation analysis and observed data in experiment.

  • PDF

Quasi-DC link type tapped-inductor Buck-Boost Micro Inverter (유사 DC-link형 탭인덕터 벅-부스트 마이크로 인버터)

  • Jang, Jong-Ho;Seo, Jung-Won;Kim, Seok-Hee;Park, Joung-Hu
    • Proceedings of the KIPE Conference
    • /
    • 2012.11a
    • /
    • pp.195-196
    • /
    • 2012
  • 본 논문에서는 저가형 고효율의 탭인덕터 벅-부스트 마이크로 인버터를 제안한다. 제안하는 인버터는 정상상태 연속모드(CCM)에서 단상전력계통에 고역률의 정현파전류를 공급할 수 있는 새로운 구조이다. 강압시에는 벅모드로 동작하며, 승압시에는 탭인덕터 부스트 모드로 동작한다. 정류형태의 전류를 2차측에 공급하면, 낮은 주파수를 사용하는 전파정류 인버터가 고역률의 교류 파형으로 변환한다. 벅부스트에 탭인덕터를 적용함으로써 권선비에 따른 시비율을 조절할 수 있어 극단적인 승압시에도 벅부스트의 도통을 적절히 유지할 수 있다. 제안하는 인버터는 정상상태 연속모드(CCM)에서 PSIM을 통해 시뮬레이션을 하여 증명하였다.

  • PDF

Controller Design and Dynamic Performance Analysis of UPFC based on 3-Level Inverters (3-레벨 인버터 UPFC의 제어기설계와 동특성해석)

  • Han, Byeong-Mun
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.49 no.6
    • /
    • pp.272-279
    • /
    • 2000
  • This paper describes a controller design and dynamic performance analysis of UPFC based on 3-level inverters. Major attention is focused on the controller design for both shunt and series inverters, including regulator design for the dc link voltage sharing across the dc capacitors. An energy-based approach was investigated for effectively designing the controller. A detailed UPFC model has been developed with EMTP using 24-pulse 3-level inverters to verify this approach. Simulation results about dynamic performance of UPFC confirm effects for increasing transmission capacity and damping low-frequency oscillation. The developed simulation model would be very effective to analyze the dynamic performance of UPFC.

  • PDF

Improved Active Power Filter Performance Based on an Indirect Current Control Technique

  • Adel, Mohamed;Zaid, Sherif;Mahgoub, Osama
    • Journal of Power Electronics
    • /
    • v.11 no.6
    • /
    • pp.931-937
    • /
    • 2011
  • This paper presents a method for the performance improvement of a shunt active power filter (SAPF) using the indirect current control (ICC) scheme. Compared to the conventional direct current control (DCC) scheme, the ICC gives better performance with a lower number of sensors. A simplified and efficient control algorithm using a low cost Intel 80C196KC microcontroller is implemented using only two current sensors for the source current and one voltage sensor for the DC-link voltage of the SAPF circuit. The objective is to eliminate harmonics and to compensate the reactive power produced by non-linear loads such as an uncontrolled rectifier feeding an inductive load. The APF is realized using a three phase voltage source inverter (VSI) with a dc bus capacitor. Experimental results are presented to prove the better performance of the ICC method over the DCC one.

Power-factor improvement of residential solar air-conditioner power system (가정용 태양광 에어컨 전원시스템의 역률 개선)

  • Park, Y.J.;Mun, S.P.;Park, J.W.;Suh, K.Y.;Kim, Y.M.
    • Proceedings of the KIEE Conference
    • /
    • 2002.06a
    • /
    • pp.6-8
    • /
    • 2002
  • Generally in solar air conditioning system, the diode rectifier is used to build up DC link voltage from AC source. The diode rectifier is simple and cheap but it brings out the problems of low power factor and plentiful harmonics at the AC source. Also It can degrade the utilization rate of solar energy because the reverse of power flow cannot be made. Hence, in this paper to overcome the peak power problems in summer and to endure good AC input characteristics, solar air conditioning system using the PWM converter is proposed. A high input power factor of 97[%] and an efficiency of 98[%] are also obtained. The harmonic guide lines of proposed rectifier is no interfered with inverter switching, resulting in a simple, reliable and low cost ac to dc converters in comparison with the boost type current improving circuits.

  • PDF

A Novel Quadrant Search Based Mitigation Technique for DC Voltage Fluctuations in Multilevel Inverters

  • Roseline, Johnson Anitha;Vijayenthiran, Subramanian;V., Rajini;Mahadevan, Senthil Kumaran
    • Journal of Power Electronics
    • /
    • v.15 no.3
    • /
    • pp.670-684
    • /
    • 2015
  • The hybrid cascaded multilevel inverter (HCMLI) is a popular converter topology that is being increasingly used in high power medium voltage drives. The intricacy of the control technique for a HCMLI increases with the number of levels and due to fluctuating dc voltages. This paper presents a novel offline quadrant search based space vector modulation technique to synthesize a sinusoidal output from a dispersed pattern of voltage vectors due to different voltages in the auxiliary unit. Such an investigation has never been reported in the literature and it is being attempted for the first time. The method suggested distributes the voltage vectors for a reduced total harmonic distortion at minimal computation. In addition, the proposed algorithm determines the maximum modulation index in the linear modulation range in order to synthesize a sinusoidal output for both normal and abnormal vector patterns. It is better suited for a wide range of practical applications. It is particularly well suited for renewable source fed inverters which utilize large capacitor banks to maintain the dc link, which are prone to such slow fluctuations. The proposed quadrant search space vector modulation technique is simulated using MATLAB/SIMULINK and implemented using a Nexys-2 Spartan-3E FPGA for a developed prototype.

Design and implementation of 3 kW Photovoltaic Power Conditioning System using a Current based Maximum Power Point Tracking (전류형 MPPT를 이용한 3 kW 태양광 인버터 시스템 제어기 설계 및 구현)

  • Cha, Han-Ju;Lee, Sang-Hoey;Kim, Jae-Eon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.10
    • /
    • pp.1796-1801
    • /
    • 2008
  • In this paper, a new current based maximum power point tracking (CMPPT) method is proposed for a single phase photovoltaic power conditioning system and the current based MPPT modifies incremental conductance method. The current based MPPT method makes the entire control structure of the power conditioning system simple and uses an inherent current source characteristic of solar cell array. In addition, digital phase locked loop using an all pass filter is introduced to detect phase of grid voltage as well as peak voltage. Controllers about dc/dc boost converter, dc-link voltage, dc/ac inverter is designed for a coordinated operation. Furthermore, PI current control using a pseudo synchronous d-q transformation is employed for grid current control with unity power factor. 3kW prototype photovoltaic power conditioning system is built and its experimental results are given to verify the effectiveness of the proposed control schemes.