• 제목/요약/키워드: DC link inverter

검색결과 449건 처리시간 0.03초

PWM 콘버터와 공진형 인버터를 채용한 UPS 개발 (The development of an UPS using PWM Converter and Resonant Inverter)

  • 민병권;유승표;백병산;김연풍;신현주;김동욱;유동욱;백주원
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 A
    • /
    • pp.550-552
    • /
    • 1996
  • In order to develop a noble Uninterruptible Power Supply(UPS), we designed and manufactured the UPS using the PWM converter and the Resonant DC Link Inverter. This paper describes the power circuits, the key techniques, the control and monitoring unit of the developed UPS. Finally, using the UPS we verified the superiority through the type test.

  • PDF

SPICE를 이용한 ACRDCL 인버터의 시뮬레이션 및 설계 (Simulation and Design of ACRDCL Inverter Using SPICE)

  • 한수빈;정봉만;김규덕;최수현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 하계학술대회 논문집 A
    • /
    • pp.435-437
    • /
    • 1994
  • Cramped resonant DC link inverter is analyzed by widely available software such as SPICE. In this paper, the model of ACRDCL which is based on converter switch function rather than actual circuit configuration is used. Power circuit is modeled by functional transfer function and the controller is based on the macro-model. Computer memory and runtime are based reduced compared to micro-model. Overall performance including control strategy and harmonic characteristics in the steady state can be analyzed easily.

  • PDF

폴전압을 이용한 SVPWM 인버터의 과변조 기법 (An Overmodulation Strategy for SVPWM Inverter Using Pole Voltage)

  • 한대웅;김상훈;송영신;이은규
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 추계학술대회 논문집
    • /
    • pp.181-184
    • /
    • 2001
  • In this paper, a novel overmodulation strategy for space-vector PWM(SVPWM) inverters to utilize dc link voltage fully is presented. The proposed strategy uses the concept of SVPWM based on the zero sequence signal(offset voltage) injection principle. So, by modifying the pole voltage simply, the linear control of inverter output voltage over the whole overmodulation range can be achieved easily. The validity of the proposed strategy is confirmed by the experimental results.

  • PDF

2상 풀브릿지 인버터의 동적 과변조 기법 (Dynamic Overmodulation Strategies of Two Phase Full Bridge Inverter)

  • 조영훈;정유석;목형수;김상훈;장도현
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2008년도 하계학술대회 논문집
    • /
    • pp.241-243
    • /
    • 2008
  • In this paper, dynamic overmodulation strategies are proposed for two phase full bridge inverter. The four step operation to use maximum voltage in limited DC link is described and minimum distance, same angle and minimum switching state overmodulation techniques are presented. The simple scalar arithmetic based algorithms are proposed to implement the overmodulation techniques. Simulation results demonstrate the effectiveness of the proposed algorithms.

  • PDF

중성점 전류 리플을 고려한 3-레벨 인버터의 공간 벡터 펄스폭 변조 기법 (A SVPWM for the Small Fluctuation of Neutral Point Current in Three-level Inverter)

  • 김래영;이요한;현동석
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 연구회 합동 학술발표회 논문집
    • /
    • pp.33-37
    • /
    • 1998
  • For the high power variable speed applications, the DCTLI(diode clamped three-level inverter) have been widely used. This paper describes the analysis of the neutral point current of the DCTLI and the improved space vector-based PWM strategy considering the switching frequency of power devices, that minimizes the fluctuation of the neutral point current in spite of high modulation index region and low power factor. It contributes to decrease the capacitance of dc-link capacitor bank and to increase the neutral point voltage controllable region. Especially, even if second (or even) order harmonic is induced in load current (at this situation, is was investigated that the general control method can not suppress the neutral point voltage variation), this PWM can provide effective control method to suppress the neutral point voltage variation. Various simulation results by means of Matlab/Simulation are presented to verify the proposed PWM.

  • PDF

약계자 영역에서 최대전압 설정에 관한 연구 (The Study of the method of calculating Maximum voltage in Flux-Weakening Region)

  • 김장목;임익헌;류홍우
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1999년도 전력전자학술대회 논문집
    • /
    • pp.26-30
    • /
    • 1999
  • The constraint condition is the stator voltage and the stator current to operate the motor in the flux weakening region. The maximum current is limited by the inverter current rating and the machine thermal rating. Given DC link voltage to control the motor in the flux weakening the maximum voltage is determined by considering PWM strategy, dead time, voltage drop of the inverter switching device, and the margin of the voltage for current forcing. In this paper, the new method to determine the available maximum voltage is derived by the analythic method and by considering the factors of the voltage drop. So Determining the maximum voltage is very useful to enlarge the speed operation region in the flux weakening operation, the utility of the maximum voltage is increased.

  • PDF

폴전압을 이용한 SVPWM 인버터의 과변조 기법 (An Overmodulation Strategy for SVPWM Inverter Using Pole Voltage)

  • 김상훈;최윤영
    • 산업기술연구
    • /
    • 제21권A호
    • /
    • pp.51-57
    • /
    • 2001
  • In this paper, a novel overmodulation strategy for space-rector PWM(SYPWM) inverters to utilize dc link voltage fully is presented. The proposed strategy uses the concept of SVPWM based on the zero sequence signal(offset voltage) injection principle. So, by modifying the pole voltage simply, the linear control of inverter output voltage over the whole overmodulation range can be achieved easily. The proposed strategy is so simple that its practical implementation is easy. The validity of the proposed strategy is confirmed by the experimental results.

  • PDF

리튬 배터리를 연계한 100kVA UPQC 개발 및 성능시험 (The Development and Experimental Evaluation of 100kVA Unified Power Quality Conditioner interconnected to the Li-Battery System)

  • 이학주;채우규;박중성;손진만;최은식
    • 조명전기설비학회논문지
    • /
    • 제26권10호
    • /
    • pp.102-110
    • /
    • 2012
  • This paper propose the advanced topology of UPQC, its DC link is connected with Lithium battery, to compensate the momentary interruptions. The proposed system can be operated as UPS mode using the parallel inverter, which control the charge or discharge of battery, in case of the interruption. We dvelop 100kVA UPQC using the proposed topology to rise the power quality and the reliability of Microgrid. We verify its usefulness through voltage compensation test, UPS operation test and etc. using Microgrid test facility.

A Novel Circuit Configuration of UPS with Auxiliary Inverter and Its Specific Control Implementations

  • Hirachi, Katsuya;Nakaoka, Mutsuo
    • Journal of Power Electronics
    • /
    • 제3권4호
    • /
    • pp.224-229
    • /
    • 2003
  • The rapid expansion of small computers over the last 10-odd years has brought about great changes in the circumstances affecting UPSs. There are strong demands that UPSs become much smaller and lighter, and more economical, which has resulted in the wide application of the circuit topology without transformer. A disadvantage of such UPS topology is that the DC link voltage is very high, which invites decreased reliability and increased cost of battery bank. Some circuit configurations were proposed to eliminate this disadvantage, but they still had problems. In this paper, a novel circuit configuration which eliminates these problems is proposed and evaluated by the experimental results of prototype UPS.

무변압기형 3상 계통연계 PV PCS (Transformerless Three-Phase Line-connected Photovoltaic PCS)

  • 서현우;권정민;권봉환
    • 전력전자학회논문지
    • /
    • 제12권5호
    • /
    • pp.355-363
    • /
    • 2007
  • 본 논문에서는 무변압기형 3상 계통연계 PV PCS (photovoltaic power conditioning system)를 제안하였다. 태양전지의 국소 최대 전력점에서 발전하는 것을 방지하여 최대 전력점에서 발전을 하도록 개선한 P&O (perturb and observe) 방식의 MPPT (maximum power point tracking) 알고리즘을 제안하였다. 3상 전압형 인버터를 외부 직류 링크 전압제어기, 내부 전류제어기, 그리고 마이크로컨트롤러로 구현하기에 적합하도록 간단화한 공간벡터 변조법을 통해 제어하여 3상 계통연계 시 단위 역률을 실현하였다. 그리고 시스템의 안정성 향상과 역률 개선을 위해 직류 링크 전압을 더 빠르고 정확하게 제어하기 위한 알고리즘을 제안하였다. 모든 알고리즘과 제어기를 하나의 마이크로컨트롤러로 구현하고 제안된 알고리즘과 제어기의 우수성을 실험을 통해 검증하였다.