• 제목/요약/키워드: DC leakage current

검색결과 242건 처리시간 0.025초

A novel DC-DC Converter for 3[kW] Fuel Cell System Residential Application (3[kW]급 주택용 연료전지시스템에 사용되는 새로운 DC-DC 컨버터)

  • Lee, S.H.;Mun, S.P.;Lee, H.W.;Suh, K.Y.;Kwon, S.K.
    • Proceedings of the KIEE Conference
    • /
    • 대한전기학회 2006년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.362-364
    • /
    • 2006
  • This paper presents a novel DC-DC Converter for 3 [kW] Fuel Cell System Residential Application. Phase shifted control is employed to regulate the output voltage and achieve soft switching. The transformer leakage inductance is utilized effectively to achieve zero voltage turn on for the power semiconductor switches. The current doubler rectifier has only one diode drop. The transformer secondary winding current rating is one half the load current. The overall effciency of the converter is improved.

  • PDF

Analysis of Current Fed Full Bridge DC-DC Converter with Active Clamp (능동 클램프형 전류형 단상 풀브리지 DC-DC 컨버터의 동작 해석)

  • Cha, Han-Ju;Choi, Soon-Ho;Ahn, Chi-Hyung
    • Proceedings of the KIEE Conference
    • /
    • 대한전기학회 2007년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.205-207
    • /
    • 2007
  • Isolated Current fed full-bridge converter with active clamp is analyzed in this paper. An active clamp branch is used for limiting the voltage overshoot in the bridge switches and rectifier diodes. Zero voltage switching(ZVS) is also realized by using the energy stored in the transformer leakage inductance. To analyze the converter, 6 modes of operation are introduced and investigated. For each of the modes, voltage and current equations are derived together with corresponding equivalent circuits. 200W prototype dc-dc converter is assembled and verifies the effectiveness of the analysis and simulation.

  • PDF

Effect of Cooling Rate on DC Accelerated Aging Characteristics of ZPCCY-Based Varistor Ceramics (ZPCCY계 바리스터 세라믹스의 DC 가속열화 특성에 미치는 냉각속도의 영향)

  • 남춘우;김향숙
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • 제15권9호
    • /
    • pp.776-782
    • /
    • 2002
  • The microstructure, V-Ι characteristics, and stability of ZnO-P $r_{6}$ $O_{11}$ CoO-C $r_2$ $O_3$- $Y_2$ $O_3$-based varistor ceramics were investigated with cooling rate in the range of 2~8$^{\circ}C$/min. The cooling rate relatively weakly affected the microstructure, the varistor voltage, and the leakage current in the V-Ι characteristics. But the nonlinear exponent relatively strongly affected by cooling rate. The cooling rate also greatly affected the stability of V-Ιand dielectric characteristics for DC accelerated aging stress. On the whole, the varistors cooled with 4$^{\circ}C$/fin exhibited the highest performance in the densification, nonlinearity, and stability. Especially, they exhibited a high stability, in which the variation rate of the varistor voltage( $V_{1㎃}$), the nonlinear exponent($\alpha$), and the dissipation factor(tan $\delta$) is -1.4%, -4.9%, and +60.0%, respectively, under DC accelerated aging stress such as 0.95 $V_{1㎃}$15$0^{\circ}C$/12 h)

DC Accelerated Aging Characteristics of Zn-Pr-Co-Cr-La Oxides-Based Varistors with Sintering Temperature (소결온도에 따른 Zn-Pr-Co-Cr-La 산화물계 바리스터의 DC 가속열화 특성)

  • Kim, Myung-Jun;Yoo, Dae-Hoon;Park, Jong-Ah;Nahm, Choon-Woo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 한국전기전자재료학회 2004년도 추계학술대회 논문집 Vol.17
    • /
    • pp.383-386
    • /
    • 2004
  • DC accelerated aging characteristics of Zn-Pr-Co-Cr-La oxides-based varistors were investigated with various sintering temperatures. The varistors sintered at $1240^{\circ}C$ exhibited the highest nonlinearity, with a nonlinear exponent of 79.3 and a leakage current of $0.3\;{\mu}A$, whereas completely degraded because of thermal runaway owing to low sintered density. The varistors sintered at $1250^{\circ}C$ exhibited not only a high nonlinearity with the nonlinear exponent 61.4 and the leakage current 0.7 ${\mu}A$, but also a high stability with the variation rates of varistor voltage and nonlinear exponent are -1.01% and -10.67%, respectively, under DC stress condition such as $(0.85\;V_{1mA}/115^{\circ}C/24\;h)+(0.90\;V_{1mA}/120^{\circ}C/24\;h)+(0.95\;V_{1mA}/125^{\circ}C/24\;h)+(0.95\;V_{1mA}/150^{\circ}C/24\;h)$.

  • PDF

A study of Protection for electrical corrosion by stray current in DC railway system (직류전기철도시스템에서의 누설전류에 의한 전식방지에 대한 연구)

  • Lee Jae-young
    • Proceedings of the KSR Conference
    • /
    • 한국철도학회 2005년도 추계학술대회 논문집
    • /
    • pp.748-753
    • /
    • 2005
  • The stray current(leakage current) in DC railway system like as Metro Subway and LRT system happens electrical corrosion on theses superstructure facilities and also underground facilities that causes the public property losses. we must study and establish on the theoretical concept and concrete phenomena for electrical corrosion, In the construction period we intend to review and find out a lot of solution to minimize theses losses. we must investigate, measure and analysis natural atmosphere of these facilities locations to present a maintenance management guide for the upcoming operation stage.

  • PDF

Variations of Interface Potential Barrier Height and Leakage Current of (Ba, Sr)$TiO_3$ Thin Films Deposited by Sputtering Process

  • Hwang, Cheol-Seong;Lee, Byoung-Taek
    • The Korean Journal of Ceramics
    • /
    • 제2권2호
    • /
    • pp.95-101
    • /
    • 1996
  • Variations of the leakage current behaviors and interface potential barrier $({\Phi}_B)$ of rf-sputter deposited (Ba, Sr)$TiO_3$ (BST) thin films with thicknesses ranging from 20 nm to 150nm are investigated as a function of the thickness and bias voltages. The top and bottom electrodes are dc-sputter-deposited Pt films. ${\Phi}_B$ critically depends on the BST film deposition temperature, postannealing atmosphere and time after the annealing. The postannealing under $N_2$ atmosphere results in a high interface potential barrier height and low leakage current. Maintaining the BST capacitor in air for a long time reduces the ${\Phi}_B$ from about 2.4 eV to 1.6 eV due to the oxidation. ${\Phi}_B$ is not so dependent on the film thickness in this experimental range. The leakage conduction mechanism is very dependent on the BST film thickness; the 20 nm thick film shows tunneling current, 30 and 40 nm thick films show Shottky emission current.

  • PDF

Single-Phase Transformerless PV Power Conditioning Systems with Low Leakage Current and Active Power Decoupling Capability

  • Nguyen, Hoang Vu;Park, Do-Hyeon;Lee, Dong-Choon
    • Journal of Power Electronics
    • /
    • 제18권4호
    • /
    • pp.997-1006
    • /
    • 2018
  • This paper proposes a transformerless photovoltaic (PV) power converter system based on the DC/AC boost inverter, which can solve the leakage current and second-order ripple power issues in single-phase grid-connected PV inverters. In the proposed topology, the leakage current can be decreased remarkably since most of the common-mode currents flow through the output capacitor, by-passing parasitic capacitors, and grounding resistors. In addition, the inherent ripple power component in the single-phase grid inverter can be suppressed without adding any extra components. Therefore, bulky electrolytic capacitors can be replaced by small film capacitors. The effectiveness of the proposed topology has been verified by simulation and experimental results for a 1-kW PV PCS.

Investigation for the Report of DC Traction Stray Current Protection (도시철도 전식방지 조사보고 현황)

  • Lee, Hyun-Goo;Ha, Tae-Hyun;Jung, Ho-Sung;Han, Moon-Sub;Bae, Jeong-Hyo
    • Proceedings of the KSR Conference
    • /
    • 한국철도학회 2008년도 추계학술대회 논문집
    • /
    • pp.281-285
    • /
    • 2008
  • Corrosion of metallic structures arises when an electric current flows from the metal into the electrolyte such as soil and water. The potential difference across the metal-electrolyte interface, the driving force for the corrosion current, can emerge due to a variety of temperature, pH, humidity and resistivity etc.. With respect to a given structure, a stray current is to be defined as a current flowing on a structure that is not part of the intended electrical circuit. Stray currents are caused by other cathodic protection installations, grounding systems and welding posts, referred to as steady state stray currents. But most often traction systems like railroads and tramlines are responsible for large dynamic stray currents. This type of stray current is generally results from the leakage of return currents from large DC traction systems that are grounded or have a bad earth-insulated return path. This paper investigates the reports, which is made for protecting the electrical corrosion by the DC traction stray current before the construction period.

  • PDF

Analysis, Design and Implementation of a Soft Switching DC/DC Converter

  • Lin, Bor-Ren
    • Journal of Power Electronics
    • /
    • 제13권1호
    • /
    • pp.20-30
    • /
    • 2013
  • This paper presents a soft switching DC/DC converter for high voltage application. The interleaved pulse-width modulation (PWM) scheme is used to reduce the ripple current at the output capacitor and the size of output inductors. Two converter cells are connected in series at the high voltage side to reduce the voltage stresses of the active switches. Thus, the voltage stress of each switch is clamped at one half of the input voltage. On the other hand, the output sides of two converter cells are connected in parallel to achieve the load current sharing and reduce the current stress of output inductors. In each converter cell, a half-bridge converter with the asymmetrical PWM scheme is adopted to control power switches and to regulate the output voltage at a desired voltage level. Based on the resonant behavior by the output capacitance of power switches and the transformer leakage inductance, active switches can be turned on at zero voltage switching (ZVS) during the transition interval. Thus, the switching losses of power MOSFETs are reduced. The current doubler rectifier is used at the secondary side to partially cancel ripple current. Therefore, the root-mean-square (rms) current at output capacitor is reduced. The proposed converter can be applied for high input voltage applications such as a three-phase 380V utility system. Finally, experiments based on a laboratory prototype with 960W (24V/40A) rated power are provided to demonstrate the performance of proposed converter.

Effect of Sintering Time on Degradation Characteristics of ZPCCY-Based Varistors (ZPCCY계 바리스터의 열화특성에 미치는 소결시간의 영향)

  • 남춘우;박종아
    • Journal of the Korean Ceramic Society
    • /
    • 제41권6호
    • /
    • pp.464-470
    • /
    • 2004
  • The electrical stability of ZPCCY-based varistors composing of ZnO-Pr$_{6}$O$_{11}$-CoO-C $r_2$ $O_3$- $Y_2$ $O_3$ ceramics were investigated in various DC accelerated aging stress with sintering times. Sintering time greatly affected electrical properties and stability. Sintering time decreased nonlinear exponent in the range of 51.2∼23.8 and increased leakage current in the range of 1.3∼5.6 ${\mu}$A. The varistor sintered for 1 h exhibited high nonlinearity, whereas relatively low stability. On the contrary, the varistor sintered for 3 h exhibited low nonlinearity, whereas relatively high stability. But the varistor sintered for 2 h exhibited not only good nonlinearity, with nonlinear exponent of 38.6 and leakage current of 3.6 ${\mu}$A but also high stability, in which the variation rates of varistor voltage, nonlinear exponent, leakage current, and dissipation factor are -0.80%, -1.81 %, +74.4%, and +0.88%, respectively.