• Title/Summary/Keyword: DC home appliance

Search Result 18, Processing Time 0.036 seconds

SR Drive System for LSEV (LSEV용 SRM 구동시스템)

  • Hwang Hyung-Jin;Park Han-Woong;Ahn Jin-Woo
    • Proceedings of the KIPE Conference
    • /
    • 2004.07a
    • /
    • pp.206-209
    • /
    • 2004
  • The switched reluctance motor(SRM) drive system provides a good adjustable speed and torque characteristics. SRM has the possibility of maintaining full power over a wide speed range. So, many attempts are being done from home appliances to industrial machinery and tools. Especially, a traction drive of an SRM is one of a good application for it's DC-series characteristic. However, because of the switching mechanism it has some disadvantage of noise and vibration. It is difficult to adopt to an appliance demanding silency. A noise simulation and design of 6/4 and 12/8 SRM was done in order to compare each other.

  • PDF

Design of SRM for Low Noise Drive of EV (소음저감을 위한 EV용 SRM 구동 시스템의 설계)

  • Song H.S.;Park S.J.;Ahn J.W.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07b
    • /
    • pp.840-843
    • /
    • 2003
  • The switched reluctance motor(SRM) drive system provides a good adjustable speed and torque characteristics. SRM has the possibility of maintaining full power over a wide speed range. So, many attempts are being done from home appliances to industrial machinery and tools. Especially, a traction drive of an SRM is one of a good application for it's DC-series characteristic. However, because of the switching mechanism, it has some disadvantage of noise and vibration. It is difficult to adopt to an appliance demanding silency. A noise simulation and design of 6/4 and 12/8 SRM was done in order to compare each other was done.

  • PDF

SR Drive System for LSEV (LSEV용 SR Drive System)

  • Song Hyun-Soo;Ahn Jin-Woo;An Young-Ju;Park Sung-Jun
    • Proceedings of the KIPE Conference
    • /
    • 2003.11a
    • /
    • pp.109-112
    • /
    • 2003
  • SRM(switched reluctance motor) provides a excellent adjustable speed and torque characteristics. SRM has the possibility of maintaining full power over a wide speed range. So, many attempts are being done from home appliances to industrial applications. Especially, a traction drive of an SRM is one of a good application for it's DC-series characteristic. However, because of the switching mechanism and reluctance torque, it has some disadvantage Of noise and Vibration. It is difficult to adopt to an appliance demanding silency. A performance and noise tests with 6/4 and 12/8 SRM were done to compare the characteristics.

  • PDF

A Study on the Performance Improvement for Skeleton type 2-Phase BLDC Motor (스캘리턴 형상을 갖는 2상 BLDC 모터의 특성향상에 관한 연구)

  • Rhyu, S.H.;Im, T.B.;Chung, J.K.;Ha, K.S.;Chang, H.S.;Back, S.H.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.656-659
    • /
    • 2000
  • Recently, the skeleton type 2-phase brushless DC motor has been used in electric home appliance for low price and low energy consumption. In this paper, we analyzed a skeleton type 2-phase BLDC motor using time-step finite element method. And the validity of analysis is confirmed by measuring the flux distribution on the surface of permanent magnet and back-EMF. As well, we have calculated the dynamic characteristics of target motor considering the Hall sensor position. So, we have found the optimum switching position, and improved efficiency of 2-phase BLDC motor.

  • PDF

SR Drive System for LSEV (저속 전기자동차용 SRM의 구동특성 향상을 위한 제어시스템)

  • Hwang Hyung-Jin;Lee Dong-Hee;Ahn Jin-Woo
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.1013-1015
    • /
    • 2004
  • SRM (switched reluctance motor) provides an excellent adjustable speed and torque characteristics. SRM has the possibility of maintaining full power over a wide speed range. So, many attempts are being done from home appliances to industrial applications. Especially, a traction drive of an SRM is one of a good application for it's DC-series characteristic. However, because of the switching mechanism and reluctance torque. it has some disadvantage of noise and vibration. It is difficult to adopt to an appliance demanding silency. Performance and noise tests with 6/4 and 12/8 SRM were excuted to compare the characteristics.

  • PDF

Development of Low Noise SRM Drive for EV Application (소음저감을 위한 EV용 SRM 및 제어기의 개발)

  • Song, Hyun-Soo;Park, Sung-Jun;Ahn, Jin-Woo
    • Proceedings of the KIEE Conference
    • /
    • 2003.07b
    • /
    • pp.753-755
    • /
    • 2003
  • The switched reluctance motor(SRM) drive system provides a good adjustable speed and torque characteristics. SRM has the possibility of maintaining full power over a wide speed range. So, many attempts are being done from home appliances to industrial machinery and tools. Especially, a traction drive of an SRM is one of a good application for it's DC-series characteristic. However, because of the switching mechanism, it has some disadvantage of noise and vibration. It is difficult to adopt to an appliance demanding silency. A noise simulation of 6/4 and 12/8 SRM was done in order to compare each other, and the design was done carefully.

  • PDF

Design and Drive Characteristics of BLDC Motor Control System for Tread Mill Application (Tread Mill 구동용 BLDC 전동기 제어시스템 설계 및 운전특성)

  • 안진우;이동희
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.8 no.3
    • /
    • pp.239-246
    • /
    • 2003
  • Brushless D.C. Motor is widely used for industrial application because of high efficiency and high power density. Especially, in home appliance, BLDCM is very useful due to high control performance and low acoustic noise. In this paper, BLDCM and its controller are designed and developed for tread mill application. With the restricted stator structure, permanent magnet rotor is designed for manufacturing and cost effectiveness using CAD and FEM analysis. A ferrite magnetic material is used as a rotor magnet for the cost and temperature advantages. For a stable operation of tread mill, over current and temperature can be detected and protected. The designed BLDCM and its controller was verified by the experimental results.

A survey on the EMF Levels of Study and Electric Appliances in Korea (국내 전철 및 가전제품을 대상으로 한 전자장 수준 실태조사)

  • Jang, Seong Ki;Cho, Yong Sung;Lee, Seok Jo;Yoo, Seong Wha;Jung, Kyung Mi;Lim, Jun Ho
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.15 no.1
    • /
    • pp.71-81
    • /
    • 2005
  • The purposes of this study was to collect, analyze, and describe the MF exposure levels from subways in Korea and to measure and evaluate the MF levels generated from electric appliances used at general homes. The target subway lines were Seoul Metropolitan Line 1 to Line 8, Bundang Line, Incheon Line, Daegu Line, Gwangju Line, and Busan Line 1 and Line 2. We measured at each station in those subway lines and, all the train types (pantograph-equipped, motor-equipped, and common), and platform types(facing and isolating) were investigated by the distance(80, 200, 400 cm) from the train on 19 targeted subway lines using 3 magnetic field measuring devices (EMDEXII, Enertech Co.) during the survey from January till October, 2004. On the other hand, the levels of the 60Hz magnetic fields generated from 14 items of home electric appliances such as electric blankets, hair dryers, electric razors, etc. were measured at 10 general homes using 5 EMDEXII meters with a sampling interval of 1.5 second by the distance(surface, 30, 50, 100, 300cm ) from the target electric appliances. The survey results in the whole subway lines examined in this study were as follows; Seoul Metropolitan Line 4 using AC(alternating current) power source showed the highest mean value of $2.85{\mu}T$, followed by Seoul Metropolitan Line 1 running between Seoul and Incheon using AC($2.78{\mu}T$), Seoul Metropolitan Line 1 between Seoul and Uijongbu using AC($2.73{\mu}T$), Bundang Line using AC($1.79{\mu}T$), Seoul Metropolitan Line 1 connected from Yongsan using AC($1.67{\mu}T$), Seoul Metropolitan Line 1 between Seoul and Suwon using AC($0.79{\mu}T$), and so on. In general, the intensity of the magnetic field in the subway systems in Korea was significantly higher when using AC($2.14{\pm}0.91{\mu}T$) than when using DC($0.29{\pm}0.44{\mu}T$) power source. Among the home electric appliances examined, microwave ovens showed the highest mean value of $7.69{\mu}T$, followed by hair dryers($6.47{\mu}T$), vacuum cleaners($5.27{\mu}T$), televisions ($2.26{\mu}T$), electric blankets($1.38{\mu}T$), personal computers ($0.81{\mu}T$), and so on. Two items of electric appliances showed the excess value of $0.2{\mu}T$ at the distance of 30cm in the MF exposure level; electric razors $1.58{\pm}2.13{\mu}T$ and vacuum cleaners $0.48{\pm}0.44{\mu}T$. As a whole, this study showed a tendency that the shift of the MF levels according to the increase of distance from the electric appliances was lower than those of the results surveyed in UK and USA. As a result, this study is expected to suggest meaningful data for the future study in exposure assessment of magnetic fields and for the establishment of guidelines for subways and electric appliances in Korea. More detailed and large scaled exposure assessment studies should be performed continuously to get the various and useful information on health risk assessment of MFs in Korea.