• 제목/요약/키워드: DC grid

검색결과 531건 처리시간 0.026초

Solar Inverter with Grid Power Generation

  • Suchitra Khoje;Govind Wanje;Ramesh Mali
    • International Journal of Computer Science & Network Security
    • /
    • 제23권9호
    • /
    • pp.162-165
    • /
    • 2023
  • Power can be generated from either renewable or non-renewable sources. Renewable sources are liked to maintain a strategic distance from contamination emanation and rely on upon fossil energizes which is decreasing day by day. The proposed sun powered vitality transformation unit comprises of a sun oriented exhibit, Bidirectional DC-DC converter, single stage inverter and AC. The inverter changes over DC control from the PV board into AC power and offered it to the heap which is associated with the lattice. The photovoltaic sun powered vitality (PV) is the most direct approach to change over sunlight based radiation into power and depends on the photovoltaic impact. The most extreme power point following of the PV yield for all daylight conditions is a key to keep the yield control per unit cost low for fruitful PV applications. Framework associated PV frameworks dependably have an association with people in general power matrix by means of an appropriate inverter in light of the fact that a PV module conveys just dc power. This project presents the new design, Development and Performance Analysis of a Grid Connected PV Inverter. Demonstrate that the proposed framework can lessen the Energy Consumption radically from the power board and give a solid support to the Grid.

Study on the Influence of Grid Voltage Quality on SVG and the Suppression

  • Yi, Guiping;Hu, Renjie
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • 제3권2호
    • /
    • pp.155-161
    • /
    • 2014
  • Industrial Static Var Generator (SVG) is typically applied at or near the load center to mitigate voltage fluctuation, flicker, phase unbalance, non-sine distortion or other load-related disturbance. Special attention is paid to the influence of grid voltage quality on SVG current, the non-sine distortion and unbalance of grid voltage causes not only the AC current distortion and unbalance but also the DC voltage fluctuation. In order to let the inverter voltage contain the fundamental negative sequence and harmonic component corresponding to the grid voltage, a new dual-loop control scheme is proposed to suppress the influence in this paper. The harmonic and negative sequence voltage decomposition algorithm and DC voltage control are also introduced. All these analyses can guide the practical applications. The simulation results verify the feasibility and effectiveness of the present control strategy and analyses.

Crowbar 운전을 가지는 이중여자유도발전기 풍력발전시스템의 제어전략 (Control Strategies of Doubly Fed Induction Generator -Based Wind Turbines with Crowbar Activation)

  • 저스토 잭슨 존;노경수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.706-707
    • /
    • 2011
  • The insertion of the crowbar system in the doubly fed induction generator rotor circuit for a short period of time during grid disturbance enables a more efficient way of limiting transient rotor current and hence protecting the rotor side converter (RSC) and the DC - link capacitor. When crowbar is activated at fault occurrence and clearance time, RSC is blocked while DC -link capacitor and the grid side converter (GSC) can be controlled to provide reactive power support at the PCC and improve the voltage which helps to comply with grid codes. In this paper, control strategies for crowbar system to limit the rotor current during fault is presented with RSC and GSC controllers are modified to control PCC voltage during disturbance to enhance DFIG wind farm to comply with some strict grid codes. Model simulated on MATLAB/Simulink verify the study through simulation results presented.

  • PDF

가스 엔진용 1kW급 계통 연계 영구자석형 동기발전기 구동 시스템 설계 (Design of Control System for 1kW Grid-connected Permanent Magnet Synchronous Generator)

  • 이태영;조영훈
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2017년도 추계학술대회
    • /
    • pp.69-70
    • /
    • 2017
  • This paper presents design of control system for permanent magnet synchronous generator(PMSG). The gas engine make rotating mechanical energy from gas fuel energy. The rotor of synchronous generator is connected to axis of engine. And it converts the mechanical energy to the electrical energy. The control system of PMSG helps the electrical energy to flow to grid. the single phase pfc rectifier controls the DC-link voltage by controlling the current of filter inductor. If the DC-link voltage is higher than the voltage reference, the filter current could be controlled to flow to grid. The three phase inverter controls the stator current of generator. The direction of the current is controlled depends on motoring or generating mode. The feasibility of the grid-connected PMSG is verified by the experimental results with 1kW prototype.

  • PDF

Suppression of silicon clusters using a grid mesh under DC bias

  • Kim, Yonwon;Kang, Jun
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제41권2호
    • /
    • pp.146-149
    • /
    • 2017
  • Si clusters generated during the plasma chemical vapor deposition (CVD) process have a great influence on the quality of the fabricated films. In particular, in hydrogenated amorphous silicon thin films (a-Si:H) used for thin film solar cells, Si clusters are mainly responsible for light-induced degradation. In this study, we investigated the amount of clusters incorporated into thin films using a quartz crystal microbalance (QCM) and specially designed cluster eliminating filters, and investigated the effect of the DC grid mesh in preventing cluster incorporation. Experimental results showed that as the applied voltage of the grid mesh, which is placed between the electrode and the QCM, decreased, the number of clusters incorporated into the film decreased. This is due to the electrostatic force from the grid mesh bias, and this method is expected to contribute to the fabrication of high-quality thin films by preventing Si cluster incorporation.

Digital Control of Secondary Active Clamp Phase-Shifted Full-Bridge Converters

  • Che, Yanbo;Ma, Yage;Ge, Shaoyun;Zhu, Dong
    • Journal of Power Electronics
    • /
    • 제14권3호
    • /
    • pp.421-431
    • /
    • 2014
  • A DSP-based self-adaptive proportional-integral (PI) controller to control a DC-DC converter is proposed in this paper. The full-bridge topology is adopted here to obtain higher power output capability and higher conversion efficiency. The converter adopts the zero-voltage-switching (ZVS) technique to reduce the conduction losses. A parallel secondary active clamp circuit is added to deal with the voltage overshoot and ringing effect on the transformer's secondary side. A self-adaptive PI controller is proposed to replace the traditional PI controller. Moreover, the designed converter adopts the constant-current and constant-voltage (CC-CV) output control strategy. The secondary active clamp mechanism is discussed in detail. The effectiveness of the proposed converter was experimentally verified by an IGBT-based 10kW prototype.

MPPT 알고리즘의 주기에 따른 발전 영향 분석 (Analysis of Power Generation Characteristics according to the MPPT Algorithm Period)

  • 민준기;최원석
    • 전기학회논문지P
    • /
    • 제67권4호
    • /
    • pp.233-237
    • /
    • 2018
  • In this paper, we compared power generation characteristics of two MPPT algorithms, P & O and InC, applied to grid-connected solar inverters. The MPPT detects the voltage and current of the solar module string and transfers the power to the DC link. Since the grid is connected by the power conversion circuit, the grid connection control and the MPPT control influence each other. The power generation characteristics were analyzed by Psim simulation according to the MPPT cycle in the weak grid conditions.

무변압기형 태양광 인버터의 출력 전류 DC offset 제거 방법 (Output Current DC offset Removal Method for Trans-less PV Inverter)

  • 홍기남;최익;최주엽;이상철;이동하
    • 한국태양에너지학회 논문집
    • /
    • 제32권spc3호
    • /
    • pp.255-261
    • /
    • 2012
  • Since PV PCS uses output current sensor for ac output current control, the sensor's sensing value includes unnecessary offset inevitably. If PV inverter is controlled by the included offset value, it's output current will generate DC offset. The DC offset of output current for trans-less PV inverter is fatal to grid, which results in saturating grid side transformer. Usually DSP controller of PV inverter reads several times sensing value during initial operation and, finally, it's average value is used for offset calibration. However, if temperature changes, the offset changes, too. And also, the switch device is not ideal, both each switching element of the voltage drop difference and on & off time delay difference generate DC offset. Thus, to compensate for deadtime and the switch voltage drop, feedback control by output current DC offset should be provided to compensate additional distortion of the output current. The validity of the proposed method is confirmed through PSIM simulation.

Design and Implementation of Photovoltaic Power Conditioning System using a Current-based Maximum Power Point Tracking

  • Lee, Sang-Hoey;Kim, Jae-Eon;Cha, Han-Ju
    • Journal of Electrical Engineering and Technology
    • /
    • 제5권4호
    • /
    • pp.606-613
    • /
    • 2010
  • This paper proposes a novel current-based maximum power point tracking (CMPPT) method for a single-phase photovoltaic power conditioning system (PV PCS) by using a modified incremental conductance method. The CMPPT method simplifies the entire control structure of the power conditioning system and uses an inherent current source characteristic of solar cell arrays. Therefore, it exhibits robust and fast response under a rapidly changing environmental condition. Digital phase locked loop technique using an all-pass filter is also introduced to detect the phase of grid voltage, as well as the peak voltage. Controllers of dc/dc boost converter, dc-link voltage, and dc/ac inverter are designed for coordinated operation. Furthermore, a current control using a pseudo synchronous d-q transformation is employed for grid current control with unity power factor. A 3 kW prototype PV PCS is built, and its experimental results are given to verify the effectiveness of the proposed control schemes.

Multi-field Coupling Simulation and Experimental Study on Transformer Vibration Caused by DC Bias

  • Wang, Jingang;Gao, Can;Duan, Xu;Mao, Kai
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권1호
    • /
    • pp.176-187
    • /
    • 2015
  • DC bias will cause abnormal vibration of transformers. Aiming at such a problem, transformer vibration affected by DC bias has been studied combined with transformer core and winding vibration mechanism use multi-physical field simulation software COMSOL in this paper. Furthermore the coupling model of electromagnetic-structural force field has been established, and the variation pattern of inner flux density, distribution of mechanical stress, tension and displacement were analyzed based on the coupling model. Finally, an experiment platform has been built up which was employed to verify the correctness of model.