• 제목/요약/키워드: DC distribution network

검색결과 53건 처리시간 0.026초

캐나다 앨버타 상부 데본기 Grosmont층의 불연속면 구조 특성 (Characteristics of Fracture System of the Upper Devonian Grosmont Formation, Alberta, Canada)

  • 엄정기;김민성;조석주
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2010년도 추계 학술발표회
    • /
    • pp.790-799
    • /
    • 2010
  • The Upper Devonian Grossmont Formation in Alberta, Canada reserves an estimated 50 billion cubic meters of bitumen and possess about 1/6 of the total bitumen resources in northern Alberta. However, unlike the overlying Athabasca oil sands, non conventional bitumen resources has not been developed as yet. The carbonate rocks of Grosmont Formation have been subject to various stages of diagenesis, including dolomatization and karstification with a strong effect on the distribution of porosity and permeability, which resulted in highly heterogeneous reservoirs. An extensive fracture logging and mapping was performed on total of six boreholes located in the study area to explore the characteristics of fracture geometry system and the subsurface structures of carbonates reservoir that holds bitumen. Fractal dimension was used as a measure of the statistical homogeneity of the fractured rock masses. The applicability of random Cantor dust, Dc, as a fractal parameter was examined systematically. The statistical homogeneity of fractured carbonates rock masses was investigated in the study area. The structural domains of the rock masses were delineated depthwise according to estimated Dc. The major fracture orientation was dominated by horizontal beddings having dip of $0-20^{\circ}$. Also, fractures having high dip angles existed with relatively low frequency. Three dimensional fracture network modeling for each structural domain has been performed based on fracture orientation and intensity, and some representative conceptual models for carbonates reservoir in the study area has been proposed. The developed subsurface conceptual models will be used to capture the geomechanical characteristics of the carbonates reservoir.

  • PDF

역물류를 고려한 통합물류망에서의 입지:경로문제 (A Location-Routing Problem for Logistics Network Integrating Forward and Reverse Flow)

  • 나호영;이상헌
    • 산업공학
    • /
    • 제22권2호
    • /
    • pp.153-164
    • /
    • 2009
  • An effective management for reverse flows of products such as reuse, repair and disposal, has become an important issue for every aspect of business. In this paper, we study the Location-Routing Problem (LRP) in the multi-stage closed-loop supply chain network. The closed-loop supply chain in this study integrated both forward and reverse flows. In forward flow, a factory, Distribution Center (DC) and retailer are considered as usual. Additionally in reverse flow, we consider the Central Returns collection Center (CRC) and disposal facility. We propose a mixed integer programming model for the design of closed-loop supply chain integrating both forward and reverse flows. Since the LRP belongs to an NP-hard problem, we suggest a heuristic algorithm based on genetic algorithm. For some test problems, we found the optimal locations and routes by changing the numbers of retailers and facility candidates. Furthermore, we compare the efficiencies between open-loop and closed-loop supply chain networks. The results show that the closed-loop design is better than the open one in respect to the total routing distance and cost. This phenomenon enlarges the cut down effect on cost as an experimental space become larger.

Modeling of an On-Chip Power/Ground Meshed Plane Using Frequency Dependent Parameters

  • Hwang, Chul-Soon;Kim, Ki-Yeong;Pak, Jun-So;Kim, Joung-Ho
    • Journal of electromagnetic engineering and science
    • /
    • 제11권3호
    • /
    • pp.192-200
    • /
    • 2011
  • This paper proposes a new modeling method for estimating the impedance of an on-chip power/ground meshed plane. Frequency dependent R, L, and C parameters are extracted based on the proposed method so that the model can be applied from DC to high frequencies. The meshed plane model is composed of two parts: coplanar multi strip (CMS) and conductor-backed CMS. The conformal mapping technique and the scaled conductivity concept are used for accurate modeling of the CMS. The developed microstrip approach is applied to model the conductor-backed CMS. The proposed modeling method has been successfully verified by comparing the impedance of RLC circuit based on extracted parameters and the simulated impedance using a 3D-field solver.

HVDC용 사이리스터 소자의 전기적 특성 simulation 연구 (Electrical characteristics simulation of thyristor devices for HVDC transmission)

  • 김상철;서길수;김은동
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 C
    • /
    • pp.1559-1561
    • /
    • 2003
  • In northeast Asia, there will be several important HVDC transmission lines to be established in Korea and China for perspective electric network market. 5500V 4-inches High voltage thyristor can be used in the DC transmission and distribution of electric power system. In this application, many thyristors are connected in series for each thyristor valves. Therefore, the required low reverse-recovery charge QRR and low on-state voltage drop $V_{TM}$ for such thyristor is necessary to this application. In our work, the on-state and off-state voltage performance was simulated by commercial simulation software.

  • PDF

P2P 분산 모바일 네트워크상에서 퍼지 유사도를 이용한 멀티-레벨 스트리밍 (Multi-Level Streaming Using Fuzzy Similarity in P2P Distribution Mobile Networks)

  • 이종득
    • 한국항행학회논문지
    • /
    • 제15권3호
    • /
    • pp.364-371
    • /
    • 2011
  • P2P 분산 모바일 네트워크 환경에서 스트리밍 미디어 서비스의 QoS는 혼잡, 지연, 간섭 등과 같은 오버헤드에 많은 영향을 받는다. 미디어 객체의 중요도는 시간에 따라 변하기 때문이다. 본 논문에서는 이러한 문제를 해결하기 위하여 새로운 퍼지 유사도 기반의 멀티-레벨 스트리밍 기법 FSMS+를 제안하며, 제안된 기법은 오버헤드로 인하여 발생되는 스트리밍 서비스의 성능 저하를 최소화한다. 이를 위해서 퍼지 유사도 기반의 적합도 기법을 적용하며, 이것은 오버헤드가 최소인 스트리밍 미디어 객체를 동적으로 스트림할 수 있게 한다. 시뮬레이션 결과 제안된 기법은 거리 기반 기법, 디스크 캐싱 기법, 그리고 프리픽스 기법과 비교할 때 재전송율, 혼잡 제어율, 그리고 지연율의 성능이 보다 우수함을 보인다.

디지털로 제어되는 저압 직류 배전용 절연형 양방향 CLLC 공진형 컨버터 (Isolated Bidirectional CLLC Resonant Converter using Digital Control for LVDC Distribution System)

  • 정지훈;김호성;류명효;김종현;김태진;백주원
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2012년도 전력전자학술대회 논문집
    • /
    • pp.379-380
    • /
    • 2012
  • A bidirectional full-bridge CLLC resonant converter using a digital control method is proposed for a LVDC power distribution system. This converter can operate under high power conversion efficiency since the CLLC resonant network has soft switching capability for primary switches and output rectifiers. In addition, the power conversion efficiency of any directions is exactly the same as each other because of the symmetric structure of the converter. Intelligent digital control methods are proposed to regulate output voltage under any power flow directions. A 5kW prototype converter was designed for a high-frequency galvanic isolation of 380V dc buses using a digital signal processor to verify the performance of the proposed topology and algorithms.

  • PDF

A Mathematical Approach to Allocate the Contributions by Applying UPFCs to Transmission System Usage

  • Sedaghati, Alireza
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2005년도 ICCAS
    • /
    • pp.158-163
    • /
    • 2005
  • Competitive electricity markets necessitate equitable methods for allocating transmission usage in order to set transmission usage charges and congestion charges in an unbiased and an open-accessed basis. So in competitive markets it is usually necessary to trace the contribution of each participant to line usage, congestion charges and transmission losses, and then to calculate charges based on these contributions. A UPFC offers flexible power system control, and has the powerful advantage of providing, simultaneously and independently, real-time control of voltage, impedance and phase angle, which are the basic power system parameters on which sys-tem performance depends. Therefore, UPFC can be used efficiently and flexibly to optimize line utilization and increase system capability and to enhance transmission stability and dampen system oscillations. In this paper, a mathematical approach to allocate the contributions of system users and UPFCs to transmission system usage is presented. The paper uses a dc-based load flow modeling of UPFC-inserted transmission lines in which the injection model of the UPFC is used. The relationships presented in the paper showed modified distribution factors that modeled impact of utilizing UPFCs on line flows and system usage. The derived relationships show how bus voltage angles are attributed to each of changes in generation, injections of UPFC, and changes in admittance matrix caused by inserting UPFCs in lines. The relationships derived are applied to two test systems. The results illustrate how transmission usage would be affected when UPFC is utilized. The relationships derived can be adopted for the purpose of allocating usage and payments to users of transmission network and owners of UPFCs used in the network. The relationships can be modified or extended for other control devices.

  • PDF

반복계산법을 이용한 철도고압배전계통의 고장점표정 알고리즘 (Fault Location Estimation Algorithm in the Railway High Voltage Distribution Lines Using Flow Technique)

  • 박계인;창상훈;최창규
    • 조명전기설비학회논문지
    • /
    • 제22권2호
    • /
    • pp.71-79
    • /
    • 2008
  • 철도 고압배전선로의 경우 궤도를 따라 양방향으로 선로연변에 통신 및 신호설비와 병행하여 가공 또는 지중선로로 설치되어 있다. 가공선로의 경우에는 대기중에 노출되어 있어 뇌격, 폭풍우, 염해 등 자연현상으로 인한 고장발생이 다수 발생하고 있으며, 이에 따른 보호장치의 오 부동작이 빈번하게 발생하고 있다. 철도 고압배전선로에서 발생하는 사고 중 가장 많은 것은 1선 지락이지만 이밖에 선간 단락, 심할 경우에는 3선 지락(단락)으로까지 진전되는 사고가 있을 뿐만 아니라 단선 사고까지 발생하는 경우도 있다. 따라서 사고를 방지하기 위해서는 보다 상세한 점검보수가 필요하며, 고장발생시 조기발견과 신속한 고장처리는 철도안전수송에 중요하다. 본 논문에서는 철도 고압배전계통의 주류를 이루게 될 22.9[kV] 직접접지 계통을 대상으로 고장 발생시 고장 위치를 신속하게 표정할 수 있는 고장점 표정 알고리즘 개발을 위해 22.9[kV] 고압배전계통을 모델링 하여 특성해석과 고장해석을 수행하였고, 정확한 고장점 표정이 가능한 반복계산법을 이용한 알고리즘을 제시하였으며, 사례연구를 통해 성능을 입증하였다.

Modeling and Control Design of Dynamic Voltage Restorer in Microgrids Based on a Novel Composite Controller

  • Huang, Yonghong;Xu, Junjun;Sun, Yukun;Huang, Yuxiang
    • Journal of Electrical Engineering and Technology
    • /
    • 제11권6호
    • /
    • pp.1645-1655
    • /
    • 2016
  • A Dynamic Voltage Restorer (DVR) model is proposed to eliminate the short-term voltage disturbances that occur in the grid-connected mode, the switching between grid-connected mode and the stand-alone mode of a Microgrid. The proposed DVR structure is based on a conventional cascaded H-bridge multilevel inverter (MLI) topology; a novel composite control strategy is presented, which could ensure the compensation ability of voltage sag by the DVR. Moreover, the compensation to specified order of harmonic is added to implement effects that zero-steady error compensation to harmonic voltage in specified order of the presented control strategy; utilizing wind turbines-batteries units as DC energy storage components in the Microgrid, the operation cost of the DVR is reduced. When the Microgrid operates under stand-alone mode, the DVR can operate on microsource mode, which could ease the power supply from the main grid (distribution network) and consequently be favorable for energy saving and emission reduction. Simulation results validate the robustness and effective of the proposed DVR system.

Development of the High Input Voltage Self-Power for LVDC

  • Kim, Kuk-Hyeon;Kim, Soo-Yeon;Choi, Eun-Kyung;HwangBo, Chan;Park, Seong-Mi;Park, Sung-Jun
    • 한국산업융합학회 논문집
    • /
    • 제24권4_1호
    • /
    • pp.387-395
    • /
    • 2021
  • Distributed resources such as renewable energy sources and ESS are connected to the low voltage direct current(LVDC) distribution network through the power conversion system(PCS). Control power is required for the operation of the PCS. In general, controller power is supplied from AC power or DC power through switch mode power supply(SMPS). However, the conventional SMPS has a low input voltage, so development and research on high input voltage self-power suitable for LVDC is insufficient. In this paper, to develop Self-Power that can be used for LVDC, the characteristics of the conventional topology are analyzed, and a series-input single-output flyback converter using a flux-sharing transformer for high voltage is designed. The high input voltage Self-Power was designed in the DCM(discontinuous current mode) to reduce the switching loss and solve the problem of current dissipation. In addition, since it operates even at low input voltage, it can be applied to many applications as well as LVDC. The validity of the proposed high input voltage self-power is verified through experiments.