• 제목/요약/키워드: DC breakdown

검색결과 188건 처리시간 0.031초

Breakdown Properties in Physiological Saline by High Voltage Pulse Generator

  • Byeon, Yong-Seong;Song, Ki-Baek;Uhm, Han-Sup;Shin, Hee-M.;Choi, Eun-Ha
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2011년도 제41회 하계 정기 학술대회 초록집
    • /
    • pp.333-333
    • /
    • 2011
  • We have investigated the breakdown properties in liquids by high voltage pulse system. High voltage pulse power system is consisted of the Marx-generator with two capacitors (0.5 ${\mu}F$, withstanding voltage is 40 kV), to which the charging voltage can be applied to maximum 30 kV DC, spark gap switch and charging resistor of 20 $M{\Omega}$. We have made use of tungsten pin electrodes of anode-cathode (A-K), which are immersed into the liquids. The breakdown voltage and current signals are measured by high voltage probe (Tektronix P6015A) and current monitor (IPC CM-1.S). Especially the high speed breakdown or plasma propagation characteristics in the pulsed A-K gap have been investigated by using the high speed ICCD camera. We have measured the electron temperature through the Boltzmann plot method from the breakdown spectrums. Here the A-K gap has been changed by 1 mm, 2 mm, and 3 mm. The used liquids are distilled water and solution of salt (0.9 %). The output voltage and current signals at breakdown in distilled water are shown to be bigger than those in saline solution. The breakdown voltage and current characteristics in liquids will be discussed in accordance with A-K gap distances. It is also found that the electron temperatures and plasma densities in liquids are decreased in conformity with A-K gap.

  • PDF

고압전력케이블 현장진단시험용 종합 직류시험설비의 검토 (Design of a composite diagnostic DC test apparatus for high voltage power cable)

  • 류희석;강동식;심종태;이호진
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 E
    • /
    • pp.2326-2328
    • /
    • 1999
  • Developments of effective and economic diagnostic apparatus for industrial plastic insulated high voltage power cables are in discontented condition still. Some report told that DC high voltage was damaged plastic insulation of a partially aged power cable to lead breakdown easily. But now, we have no alternative tools of DC diagnostic apparatus, and we try to reduce a possibility of hazard DC diagnosis. DC diagnostic apparatus still have many advantages to field cable engineer like low price, portability easy applications and sufficient data. Main hazard of DC diagnosis is excessive hight of applied voltage Recent developments for DC diagnosis use considerably low voltage. But new test methods need special measuring device and manipulator, like high input impedance voltmeter, low leakage current high voltage switches, etc. So that reason, new DC diagnostic devices are normally very expensive and have low efficiency, economically. We try to design a composite test device for 3$\sim$4 newly developed method, have economical benefit th industrial engineer.

  • PDF

소자 시뮬레이션을 이용한 ESD 보호용 NMOS 트랜지스터의 항복특성 분석 (Analysis on the breakdown characteristics of ESD-protection NMOS transistors based on device simulations)

  • 최진영;임주섭
    • 전자공학회논문지D
    • /
    • 제34D권11호
    • /
    • pp.37-47
    • /
    • 1997
  • Utilizing 2-dimensional device simulations incorporating lattic eheating models, we analyzed in detail the DC breakdown characterisics of NMOS trasistors with different structures, which are commonly used as ESD protection transistors. The mechanism leading to device failure resulting from electrostatic discharge was explained by analyzing the 1st and 2nd breakdown characteristics of LDD devices. Also a criteria for more robust designs of NMOS transistor structures against ESD was suggested by examining the characteristics changes with changes in structural parameters such as the LDD doping concentration, the drain junction depth, the distance between source/drain contacts, and the source junction area.

  • PDF

$LSF_6$의 교류 밀 직류전압에 대한 절연특성연구 (The breakdown characteristics in $LSF_6$ for AC&DC voltage)

  • 최은혁;박광서;임창호;김이국;이광식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.178-179
    • /
    • 2006
  • In this paper the experiments of breakdown characteristics SF6 liquid ($LSF_6$) in model GIS(Gas Insulated Switchgear) were described. From the experiments results, The ability of $LSF_6$ insulation is higher than high-pressurized SF6 gas. The breakdown characteristics of $LSF_6$ were produced by bubble formed evaporation of $LSF_6$ and bubble caused by high electric emission. It is considered in this paper that the results are fundamental data for electric insulation design of superconductor and cryogenic equipments machinery which will be studied and developed in the future.

  • PDF

메타로센 촉매를 이용한 저밀도 폴리에틸렌의 전기적 특성 (Electrical Properties Low-Density Polyethylene by use of Metallocene Catalyst)

  • 조돈찬;;;홍진웅
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 하계학술대회 논문집
    • /
    • pp.123-127
    • /
    • 2000
  • In order to investigate the influence of manufacturing process on the electrical properties, we used two kinds of low density polyethylene prepared using metallocene catalyst (mL), linear low density polyethylene prepared using Ziegler catalyst (LL) and low density polyethylene by high pressure process (LD). mL has the narrowest composition and molecular weight distributions. We measured the dc and impulse breakdown strengths and current densities at 3$0^{\circ}C$, 6$0^{\circ}C$ and 9$0^{\circ}C$. mL had a higher breakdown strength and a lower high-field current than LD and LL. These results were discussed from the point of manufacturing processes.

  • PDF

이중편파 정류안테나의 RF-DC 변환효율 특성 분석 (A study on the Properties of RF-DC Conversion Efficiency for the Dual-Polarization)

  • 유동기;박양하;김관호;이영철
    • 한국통신학회논문지
    • /
    • 제25권3A호
    • /
    • pp.435-442
    • /
    • 2000
  • In this paper, we analyzed RF-DC conversion efficiency for the dual -polarization rectenna and the antenna position changing. Dual-Polarization rectenna consist of a two major parts, receiving antenna and rectifying circuits. We made dual-polarization 2.45GHz rectenna using the two dipole antennas and patch antenna. Rectifying circuit is consisted by a Schottky-Barrier diode with a large forward current and reverse breakdown voltage. The results of RF-DC conversion efficiency for the each of designed dual-polarization rectenna has 69.1% with 360$\Omega$(dipole type) and 75.4% with 340$\Omega$(patch type ) optimum load resistor. When the each of dual-polarization rectenna has optimal load resistor, it's conversion efficiency shows of $\pm$20% in dipole type and $\pm$5 in patch type at 0~180。position.

  • PDF

전력케이블 열화진단기법의 현장적용 (Field Application of Power Cable Diagnosis System)

  • 김주용;한재홍;송일근;김상준;이재봉;오재형
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 춘계학술대회 논문집 유기절연재료 전자세라믹 방전플라즈마 일렉트렛트 및 응용기술
    • /
    • pp.148-151
    • /
    • 2002
  • In order to prevent the failures of underground distribution power cables we need to measure insulation condition in the field. Until now we used DC high voltage as a power source for the cable diagnosis but it was not proper method to the XLPE insulation cables because DC high voltage can affect sound insulation and can't diagnose exactly insulation degradation. For these reasons we imported isothermal relaxation current measurement system called by KDA-1 from germany but it's reliability did not proved in our URD cables. DC voltage decay measurement system was developed by domestic company but they don't have field experience. In this paper we tried to prove reliability of these two systems in the field. Through the field diagnosis and Ac breakdown test the two systems showed similar results.

  • PDF

C0G 온도계수 특성을 가지는 고압용 적층 칩 캐패시티의 유전 및 내전압 특성 (Dielectric Breakdown Voltage and Dielectric Properties of High Voltage Mutilayer Ceramic Capacitor with C0G Temperature Coefficient Characteristics)

  • 윤중락;우병철;정태석
    • 한국전기전자재료학회논문지
    • /
    • 제21권2호
    • /
    • pp.137-143
    • /
    • 2008
  • High voltage MLCCs with C0G temperature coefficient characteristics could apply DC-DC invertor were investigated for its dielectric properties. Also we manufactured MLCC through various process and studied the characteristics of dielectric break down voltage [BDV] and dielectric property as the variation of thickness in the green sheet and how to pattern the internal electrode. As the thickness of green sheet is increase, the dielectric BDV per unit thickness is decreased. But as the pattern of internal electrodes were floated we could manufacture the high voltage MLCC maintained its dielectric BDV a unit.

직류 및 교류인가시 CV전력 케이블에 미치는 공간전하 특성 연구 (A Study of Characteristic for Space Charge in CV Power Cable When Impressed DC and AC Voltage)

  • 정영일;임용배;김종서
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 C
    • /
    • pp.1960-1962
    • /
    • 2000
  • Polyehtylene[PE] in polymer insulation materials of used power cable have carried out in abundance of experiment and study for electrical conduction. insulation breakdown. dielectric character and so on. When apply to field for power cable to make PE, application of DC withstand test to put in practice for inspection is get to effect accumulated space charge. In this paper, to make use of Pulsed Electro-Acoustic(PEA). It is analysis to take shape space charges under AC and DC voltage, clear up the point at issue for effect of DC withstand test.

  • PDF

터널링 자기저항 소자의 정전기 방전 시뮬레이션 (Electrostatic discharge simulation of tunneling magnetoresistance devices)

  • 박승영;최연봉;조순철
    • 한국자기학회지
    • /
    • 제12권5호
    • /
    • pp.168-173
    • /
    • 2002
  • 본 연구에서는 인체모델(humman body model; HBM)을 터널링 자기저항(tunneling magneto resistance; TMR)소자에 연결하여 정전기에 대한 방전특성을 연구하였다. 이를 위해 제조된 TMR 시편을 전기적 등가회로 바꿔 HBM에 연결하여 PSPICE를 이용해 시뮬레이션 하였다. 이러한 등가회로에서 접합부분의 모델링 요소들의 값을 변화시켜 방전특성을 관찰할 수 있었다. 그 결과 시편의 저항과 정전용량 성분의 값이 다른 요소들에 비해 수배에서 수백 배까지 커서 정전기 방전(electrostatic discharge; ESD) 민감도를 좌우하는 주요한 요소임을 알 수 있었다. 여기에서 ESD현상에 대한 내구성을 향상시키기 위해서는 정전용량을 증가시키는 것 보다 접합면과 도선의 저항값을 줄이는 것이 유리하다. 그리고 직류 전압에 대해 절연층의 전위 장벽이 낮아져 많은 전류가 흐르게 되는 항복(breakdown)전압과 셀의 물리적 구조 및 성질이 변형되어 회복되지 못하는 파괴(failure)전압을 측정하여 DC 상태에서의 내구성을 연구하였다. 이 결과를 HBM 전압에 대한 파괴 전압으로 간주하여 TMR 소자가 견딜 수 있는 HBM 전압을 예측할 수 있었다.