• 제목/요약/키워드: DC System

검색결과 4,679건 처리시간 0.031초

자동차 이중전원 시스템을 위한 새로운 ZVS 양방향 CUK DC/DC 컨버터 (A New ZVS Bi-directional CUK DC/DC Converter for a Car Dual Power Supply System)

  • 이성룡;이수원;고성훈;문제민
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2004년도 전력전자학술대회 논문집(1)
    • /
    • pp.355-358
    • /
    • 2004
  • Currently, to overcome the limit of a 14V power supply system and to enhance the stability of this system high and to make the fuel efficiency better, a research development of a 42V power supply system is actively the progress. As an intermediate step to change into an unity power supply system, a 42V/14V dual power supply system uses a DC/DC Converter as one of structure elements. Considering the main electric power sources in the next generation of the car is a 42V system a 14V power supply system has advantages as follows : In be managed efficiently and to increase the redundancy at start, to jump start with any vehicles, etc. We need the introduction of a hi-directional converter that can flow the energy each other in a dual 42V-l2V system. This paper proposed the ZVS hi-directional CUK DC/DC converter which decrease the weight with the size of the DC/DC Converter and minimize the loss when the switching happen. In this paper, a circuit design method and an action principle of the circuit was proposed. To verify the proposed circuit, a comprehensive evaluation with theoretical analysis, simulation results is presented.

  • PDF

슈퍼 커패시터를 이용한 직류철도 회생에너지 저장장치 (DC Traction Regenerative Energy Storage Devices using Super-capacitor)

  • 김종윤;정두용;장수진;이병국;원충연
    • 전력전자학회논문지
    • /
    • 제13권4호
    • /
    • pp.247-256
    • /
    • 2008
  • 직류철도의 회생제동 시 발생되는 회생에너지는 급전선로의 직류가선전압의 상승에 의해 시스템의 오동작이나 차량 정류기의 파손, 또는 급전 시스템의 전력변환 장치의 고장을 일으키는 원인이 될 수 있다. 슈퍼 커패시터를 이용한 회생에너지 저장장치는 직류가선전압을 안정화 하게하는 방법이다. 본 논문에서는 슈퍼 커패시터 뱅크를 이용하여 직류철도 시스템의 에너지 저장장치를 구현하였고, 지하철 2호선 N역과 S역의 실측값을 이용하여 가선전압이 전동차에 의한 회생에너지 발생에 따른 동작 특성과 슈퍼 커패시터의 충 방전 특성을 확인하였다. 본 논문을 통하여 직류철도 시스템에 설치된 회생에너지 저장시스템용 슈퍼 커패시터 뱅크의 동작 특성을 알 수 있고, 향 후 직류철도 모든 변전소의 직류 가선전압 실측 데이터를 이용한다면, 특정 직류철도 운행 구간에 대한 회생에너지 저장장치의 운전특성과 슈퍼커패시터의 용량 및 수명 예측으로 가격을 절감 할 수 있고 전체 시스템의 안정도 와 신뢰성을 향상시킬 수 있다.

소방 비상용 태양전지 발전시스템의 고효율 직류-교류 인버터 설계에 관한 연구 (A Study on High Efficiency DC-AC Inverter of Solar Cell Power System Used in Fire Emergency Equipment)

  • 곽동걸;이봉섭
    • 에너지공학
    • /
    • 제15권3호
    • /
    • pp.181-187
    • /
    • 2006
  • 본 논문에서는 소방 비상용으로 이용되는 태양전지 발전시스템을 제안하고, 발전시스템의 효율을 증대시키기 위한 새로운 고효율의 전력변환장치(승압용 초퍼와 인버터)가 설계된다. 직류-직류(DC-DC) 승압용 초퍼와 직류-교류(DC-AC) 인버터는 사용된 제어스위치들의 스위칭 손실을 최소화하기 위해 공진회로를 이용한 새로운 소프트 스위칭 기법이 적용되고 시스템의 효율을 증대시킨다. 또한 본 논문에서는 태양전지(solar cell)의 최대전력 전송에 의한 태양전지의 효율적인 사용을 위한 태양전지 발전전력의 최대점 $P_{max}$을 손쉽게 추종하고 검출하는 새로운 제어기법과 제어회로에 대해 상세히 해석된다. 고효율의 전력변환 장치와 태양전지 최대전력 전송회로는 컴퓨터 시뮬레이션과 실험을 통하여 그 타당성이 입증된다.

병렬운전 모델을 이용한 DC-DC 컨버터의 병렬운전 특성해석 (The Analysis of Parallel Operating Characteristics for DC-DC Converter Using the Parallel Operation Model)

  • 김수석
    • 조명전기설비학회논문지
    • /
    • 제18권5호
    • /
    • pp.174-182
    • /
    • 2004
  • 높은 생산성, 시스템 설계의 단순화 및 미래 확장에 대비한 여분의 전원 확보 등의 병렬운전 방법의 장점으로 인해 대전력 전원장치에 있어 컨버터 시스템의 병렬운전에 대한 요구가 점점 증가되어 왔다. DC-DC 컨버터의 소신호 모델을 토대로 하여, 병렬운전 시스템의 모델을 제안하였으며 각 컨버터 모듈간의 균일한 전류분배를 위해 제안된 균등 전류 분배법을 사용한 병렬운전 시스템에 대하여 논의하였다. 모의실험 프로그램을 사용하여, 서로 특성이 다른 컨버터 모듈로 구성된 병렬운전 시스템에서 마스터와 슬레이브 모듈의 위치가 자동적으로 변하면서 전류분배 오차는 제한 값 이내로 유지됨을 확인하였다. 병렬운전을 위한 제안된 컨버터 시스템의 운전 특성을 확인하기 위하여 1[kW]의 DC-DC 컨버터 모듈 2대를 제작 실험하였으며 모의실험 결과는 과도특성 및 기동특성에 있어 실험 결과와 잘 일치됨을 확인하였다.

전류제한 기능을 갖는 72[W ]급 파워 LED 태양광 보안등 (72[W] Power LED Photovoltaic Lighting System including the Current Limiting Function)

  • 박효식;한우용
    • 한국산학기술학회논문지
    • /
    • 제11권8호
    • /
    • pp.2999-3004
    • /
    • 2010
  • LED는 다른 광원에 비해 동작수명이 길고, 친환경적이며, 에너지 효율이 높은 장점을 가지고 있다. 최근 LED 기술의 발전으로 인해 고휘도, 고용량의 LED가 개발됨에 따라, 표시장치에만 적용되던 LED를 조명장치에도 적용하는 기술이 확산되고 있다. 조명장치에 적용되는 파워 LED는 발열문제로 인한 소손을 막기 위해 구동전류를 일정한 전류값 이하로 제어할 필요성이 있다. 본 논문은 파워 LED의 구동전류를 설정된 값 이하로 제어하는 전류제 한 기능을 갖는 파워 LED 태양광 보안등 개발에 관한 연구이다. 태양광 발전에 의해 생산된 전력을 DC12[V] 축전지에 저장한 후, 야간에 승압형 DC-DC 컨버터를 통해 DC24[V]로 승압시켜 파워 LED로 공급한다. 태양광 보안등 제어기, 승압형 DC-DC 컨버터, 72[W]급 파워 LED 램프를 개발하여 동작을 확인하고 관련 데이터를 도출함으로써 제안된 시스템의 타당성을 입증하였다.

Zigbee통신을 이용한 전력변환기기의 DC Bus 커패시터의 온라인 원격 고장진단 시스템 (On-line Remote Diagnosis System for DC Bus Capacitor of Power Converters Using Zigbee Communication)

  • 정완섭;손진근
    • 전기학회논문지P
    • /
    • 제64권1호
    • /
    • pp.29-34
    • /
    • 2015
  • DC bus electrolytic capacitors are used in variety of equipments as smoothing element of the power converters because it has high capacitance for its size and low price. It is responsible for frequent breakdowns of many static converters and inverter drive systems. Therefore it is important to diagnosis monitoring the condition of an electrolytic capacitor in real-time to predict the failure of power converter. In this paper, the on-line remote diagnosis monitoring system for DC BUS electrolytic capacitors of power converter using low-cost type Zigbee communication modules is developed. To estimate the health status of the capacitor, the equivalent series resistor(ESR) of the component has to be determined. The capacitor ESR is estimated by using RMS computation using AC coupling method of DC link ripple voltage/current. The Zigbee communication-based experimental results show that the proposed remote DC capacitor diagnosis monitoring system can be applied to DC/DC converter and UPS successfully.

Computer-based Automated System for Determining the Characteristics, Losses and Efficiency of Separately Excited DC Motors

  • Kaur, Puneet;Chatterji, S.
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • 제1권4호
    • /
    • pp.440-447
    • /
    • 2012
  • This paper provides essential information on research completed with the aim to develop a 'dc motor test and analysis platform' which can be used to provide dc motor characteristics, calculate losses and efficiency, and also work as a dc motor speed controller. A user can test a given dc motor for these analyses by practicing different conventional methods, but, the concept discussed in this paper, reveals how intelligent integration of all these analyses can be done with a single user friendly automated setup. Integration has been accomplished by a technique that can accommodate all types of dc motors with different ratings at various loading conditions. However, experimentally measured results of a 0.5HP separately excited dc motor using the discussed scheme are presented in the paper. Also, a comparison of the methodology of this system with conventional techniques has also been elaborated on to show the effectiveness of the system.

병렬펄스부하를 갖는 직류배전시스템을 위한 능동 공진 댐퍼에 대한 연구 (A Study of the Active Resonance Damper for a DC Distributed Power System with Parallel Pulsed Power Loads)

  • 나재두;이병헌;장한솔;우현민;김영석
    • 전기학회논문지
    • /
    • 제61권9호
    • /
    • pp.1289-1295
    • /
    • 2012
  • An active resonance damper for a DC Distributed Power System(DPS) with parallel loads is presented. Each pulse power load in a DC DPS comprises both a resistive power load and a step-up converter. The step-up converter behave as constant power load(CPL) when tightly regulated and usually cause a negative impedance instability problem. Furthermore, when an input filter is connected to a large constant power load, the instability of DC bus voltage. In this paper, a bidirectional DC/DC converter with a reduced storage capacitor quantitatively are proposed as a active resonance damper, to mitigate the voltage instability on the bus. The validity of the proposed method was confirmed by simulation and experimental works.

AC/DC 하이브리드형 혼합송전계통에서 DC 케이블의 유도전압평가에 의한 적정배열 선정 (Proper Cable Arrangement Selection by Induced Voltage Evaluation of DC Cable in AC/DC Hybrid Combined Transmission Systems)

  • 손용대;이종범
    • 전기학회논문지
    • /
    • 제64권5호
    • /
    • pp.680-688
    • /
    • 2015
  • Hybrid type combined transmission systems is being operated by AC and DC line at the same space will be expanded instead of the overhead line. However, such hybrid type combined system has problem like the arrangement selection of DC cable for effective system operation. In this paper, to select the proper arrangement of DC cable, induced voltage of DC cable influenced by AC cable was analyzed in case of several type arrangement of DC cable. Such induced voltage is in detailed analyzed not only in case of steady, but transient state. The arrangement which has the lowest induced voltage is selected as the proper one. EMTP/ATPDraw is used for modeling and analysis of hybrid type combined transmission system.

A Study on SFCL with IGBT Based DC Circuit Breaker in Electric Power Grid

  • Bae, SunHo;Kim, Hongrae;Park, Jung-Wook;Lee, Soo Hyoung
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권5호
    • /
    • pp.1805-1811
    • /
    • 2017
  • Recently, DC systems are considered as efficient electric power systems for renewable energy based clean power generators. This discloses several critical issues that are required to be considered before the installation of the DC systems. First of all, voltage/current switching stress, which is aggravated by large fault current, might damage DC circuit breakers. This problem can be simply solved by applying a superconducting fault current limiter (SFCL) as proposed in this study. It allows a simple use of insulated-gate bipolar transistors (IGBTs) as a DC circuit breaker. To evaluate the proposed resistive type SFCL application to the DC circuit breaker, a DC distribution system is composed of the practical line impedances from the real distribution system in Do-gok area, Korea. Also, to reflect the distributed generation (DG) effects, several DC-to-DC converters are applied. The locations and sizes of the DGs are optimally selected according to the results of previous studies on DG optimization. The performance of the resistive type SFCL applied DC circuit breaker is verified by a time-domain simulation based case study using the power systems computer aided design/electromagnetic transients including DC (PSCAD/ EMTDC(R)).