• Title/Summary/Keyword: DC Power-Bus

Search Result 233, Processing Time 0.027 seconds

The Compensation Method of the Modulation-delay for the Voltage type Dual PWM Converter and Composition of the Instantaneous Current Controller (전압형 Dual PWM 컨버터의 변조각 지연에 따른 보상법 및 순시전류 제어기 구성)

  • Chung, Yon-Tack;Kim, Won-Chul;Lee, Sa-Young;Chun, Ji-Yong;Kim, Hyeun-Bong;Lee, Keun-Hong
    • Proceedings of the KIEE Conference
    • /
    • 1994.07a
    • /
    • pp.369-372
    • /
    • 1994
  • In this paper, a voltage type dual PWM converter which achives the bidirectional power flow between a AC supply and a DC bus voltage is described. In PWM modulator, there exist a time difference between the sampling time and carrier wave, it achieves stable modulation even the disturbance in the synchronous AC source voltage. And this paper proposes the compensation method and the control method related a disturbance of synchronous signal using the low pass filter and phase shifter for the stable modulation. As a result the voltage type dual PWM converter makes the imput current wave as sinusoid, and performs the high power factor driving.

  • PDF

The Performance Improvement of stopping for Induction Motor Using AC Drive (인버터를 이용한 유도전동기 감속 성능 개선)

  • Park, Kyeoung-Hun;Han, Kyung-Sik
    • Proceedings of the KIPE Conference
    • /
    • 2011.07a
    • /
    • pp.296-297
    • /
    • 2011
  • Many applications involving induction motors that are controlled using variable frequency drives require the ability to stop quickly. These applications include emergency stops, quick stopping of fans, centrifuges, presses, etc. The technique that is widely accepted in the industry for achieving quick stopping makes use of brake resistors in series with a power semiconductor switch. The switch-resistor combination (brake-unit) is applied across the dc bus. The fastest decelerating time achievable depends on the size of the resistors and the switch employed. In this paper, the authors propose a novel method of achieving quick stopping times without the use of any brake-unit. Experimental test results with and without this method on a large inertia motor-load combination show that the proposed stopping method is able to reduce the stopping time significantly compared to normal decelerated stop without the need for a braking unit.

  • PDF

HID Electronic Ballast with Auto-Switching of MH and HPS Lamps (램프 인식 기능을 가진 HID 전자식 안정기의 구현)

  • Lee Chi Hwan;Choi Nam Yeul
    • Proceedings of the KIPE Conference
    • /
    • 2004.07b
    • /
    • pp.887-890
    • /
    • 2004
  • This paper presents a microprocessor controlled electronic ballast for HID lamps, which gives automatic switching between MH and HPS lamps. Lamp identification is carried out by checking variation of lamp impedance at warm-up phase. Direct spread spectrum is done by applying 1 kHz triangular wave for removing acoustic resonance. This frequency modulation of 1 kHz gives also low EMI level. The microprocessor controls the voltage of DC-bus, the voltage of ignition pulses, the power of output. A 250W electronic ballast is implemented with ATmega16 CPU.

  • PDF

An Overload Alleviation Countermeasure using New Line Outage Distribution Factor (새로운 선로사고분배계수 알고리즘을 이용한 과부하 해소대책)

  • Park, Kyu-Hong;Chung, Jai-Kil;Kang, Dong-Gu;Kim, Jung-Ha
    • Proceedings of the KIEE Conference
    • /
    • 1995.07b
    • /
    • pp.588-590
    • /
    • 1995
  • This paper presents a new algorithm for the countermeasure to alleviate the line overloads in a power system. This method utilizes network sensitivity factors which are establised from DC load flow solutions. The line outage distribution factors(LODF) are formulated using changes in network power generations to simulate the outaged line from the network. The proposed algorithm has been validated in tests on a 6-bus test system.

  • PDF

Implementation of a Digital Ballast for HID Lamps (HID 램프 디지털 안정기의 제작)

  • 이치환
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.31-35
    • /
    • 2003
  • This paper presents a microprocessor controlled digital ballast for HID lamps, which gives intelligent features such as a precise power control, optimum ignition voltage and detection of end of life. Average current mode PFC is employed for reducing EMI and a universal input. Direct spread spectrum is done by applying 1 KHz triangular wave for removing acoustic resonance. This frequency modulation of 1 KHz gives also low EMI level and no ripple on lamp current. The microprocessor controls the voltage of DC-bus, the voltage of ignition pulses, the power of output and the bandwidth of spread spectrum. A 250W digital ballast is implemented with an efficiency of 93% and a maximum EMI level of 55 ㏈${\mu}$V.

  • PDF

A Study On The Characteristic Improvement of 3 Phase Voltage Source PWM Converter (3상 전압형 PWM 컨버터의 특성개선에 관한 연구)

  • Chung, Yon-Tack;Kim, Won-Chul;Chun, Ji-Yong;Kim, Hyun-Woo;Lee, Keun-Hong
    • Proceedings of the KIEE Conference
    • /
    • 1993.07b
    • /
    • pp.830-832
    • /
    • 1993
  • In this paper, A voltage source PWM converter which achieves bidirectional power flow between a $3{\phi}$ AC supply and a DC bus voltage is described. And the paper considers both the steady state and transient response of such a device, and develops mathematical models to describe its performance under the digital control system. As a result the AC line current becomes sinusoidal and the input power factor is improved to unity.

  • PDF

The Analysis of Vibration Due to Magnetic Exciting Force in the Brushless DC Motor (다기 전력 시스템 동적 안정도 향상을 위한 분산 제어 기반 PSS 및 TCSC 제어기 설계)

  • Lee, Seung-Cheol;Seo, Jang-Cheol;Moon, Seung-Ill;Park, Jong-Keun
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.50 no.1
    • /
    • pp.13-19
    • /
    • 2001
  • This paper deals with decentralized control scheme and its application to multi-machine power systems. Decentralized control scheme has several practical advantages, because power system has geographically distributed characteristics. In this paper, decentralized observer-based optimal Power System Stabilizer(PSS) and Thyristor-Controlled Series Capacitor(TCST) controller are designed and tested in WSCC 9 bus system with one TCSC installed. Simulation results show that the proposed decentralized controller has satisfactory performances comparable to the centralized controller. In addition, using modal analysis, this paper shows that the proposed decentralized controller significantly affects only one pair of eigenvalues which have high participation with each generator, while slightly affects other eigenvalues. This result indicates that the application of the decentralized control scheme to enhance power system dynamic stability via excitation control have potential advantages because each low-damped mode occurs dominantly by each decentralized subsystem.

  • PDF

Design and Analysis of Power System for Buoy (브이용 전력시스템 설계 및 분석)

  • Jo, Kwan-Jun;Yoo, Hee-Han;Gug, Seung-Gi;Oh, Jin-Seok
    • Journal of Navigation and Port Research
    • /
    • v.31 no.3 s.119
    • /
    • pp.229-233
    • /
    • 2007
  • This paper presents the performance of PV(Photovoltaic) system, the design of MPPT(Maximum Power Point Tracker). Output of PV power system is DC, and PV power system is linked to the DC bus. The current(I)-voltage(V) output characteristic of PV cells changes with solar irradiance and cell temperature as parameters. As various PV modules respond differently to each of the parameters cited above. Maximum output of PV modules am be achieved by MPPT(Maximum Power Point Tracker) algorithm This paper includes a discussion on the performance of PV module, MPPT algorithm and the influence of PV module angle.

Construction and Assembly of KSTAR Current Leads and the Helium Control System (KSTAR 전류인입선 및 헬륨냉매 제어시스템 제작 및 설치)

  • Song, N.H.;Woo, I.S.;Lee, Y.J.;Kwag, S.W.;Bang, E.N.;Lee, K.S.;Kim, J.S.;Jang, Y.B.;Park, H.T.;Hong, J.S.;Park, Y.M.;Kim, Y.S.;Choi, C.H.
    • Journal of the Korean Vacuum Society
    • /
    • v.16 no.5
    • /
    • pp.388-396
    • /
    • 2007
  • KSTAR (Korea Superconducting Tokamak Advanced Research) current lead system (CLS) has a role to interconnect magnet power supply (MPS) in room temperature (300 K) and superconducting (SC) bus-line, electrically. For the first plasma experiments, it should be assembled 4 current leads (CL) on toroidal field (TF) current lead box (CLB) and 14 leads on poloidal field (PF) CLB. Two current leads, with the design currents 17.5 kA, and SC bus-lines are connected in parallel to supply 35 kA DC currents on TF magnet. Whereas, it could supply $20\;{\sim}\;26\;kA$ to each pairs of PF magnets during more than 350 s. At the cold terminals of the leads, there are joined SC bus-lines and it was constructed helium coolant control system, aside from main tokamak system, to protect heat flux through current leads and enhanced Joule heat due to supplied currents. Throughout the establishment processes, it was tested the high vacuum pumping, helium leak of the helium lines and hardwares mounted between the helium lines, flow controls for CL, and liquid nitrogen cool-down of possible parts (current leads, CL helium lines, and thermal shield helium lines for CLB), for the accomplishment of the required performances.

A Voltage-fed Single-stage PFC Full-bridge Converter with Asymmetric Phase-shifted Control for Battery Chargers

  • Qian, Qinsong;Sun, Weifeng;Zhang, Taizhi;Lu, Shengli
    • Journal of Power Electronics
    • /
    • v.17 no.1
    • /
    • pp.31-40
    • /
    • 2017
  • A novel voltage-fed single-stage power factor correction (PFC) full-bridge converter based on asymmetric phase-shifted control for battery chargers is proposed in this paper. The attractive feature of the proposed converter is that it can operate in a wide output voltage range without an output low-frequency ripple, which is indispensable in battery charger applications. Meanwhile, the converter can maintain a high power factor and a controllable dc bus voltage over a wide output voltage range. In this paper, the realization of PFC and the operation principle of asymmetric phase-shifted control are given. A small-signal analysis of the proposed single-stage power factor correction (PFC) full-bridge converter is performed. Experimental results obtained from a 1kW experimental prototype are given to validate the feasibility of the proposed converter. The PF is higher than 0.97 over the entire output voltage range with the proposed control strategy.