• 제목/요약/키워드: DC Output Filter

검색결과 194건 처리시간 0.032초

직접전력변환 방식을 이용한 전압 강하/상승 보상기의 구현 (Implementation of Voltage Sag/Swell Compensator using Direct Power Conversion)

  • 이상회;차한주;한병문
    • 전기학회논문지
    • /
    • 제58권8호
    • /
    • pp.1544-1550
    • /
    • 2009
  • In this paper, a new single phase voltage sag/swell compensator using direct power conversion is proposed. A new compensator consists of input/output filter, series transformer and direct ac-ac converter, which is a single-phase back-to-back PWM converter without dc-link capacitors. Advantages of the proposed compensator include: simple power circuit by eliminating dc link electrolytic capacitors and thereby, improved reliability and increased life time of the entire compensator; simple PWM strategy or compensating voltage sag/swell at the same time and reduced switching losses in the ac-ac converter. Further, the proposed scheme is able to adopt simple switch commutation method without requiring complex four-step commutation method that is commonly employed in the direct power conversion. Simulation and experimental results are shown to demonstrate the advantages of the new compensator and PWM strategy. A 220V, 3kVA single-phase compensator based on the digital signal processor controller is built and tested.

Noise Modeling and Improved Harmonic Spectrum for DC/DC Converter by RPWM Control

  • Park, Seok-Ha;Kim, Jong-Bum;Kim, Jin-Sung;Kim, Yang-Mo
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 Proceedings ICPE 98 1998 International Conference on Power Electronics
    • /
    • pp.620-624
    • /
    • 1998
  • Higher operating frequency provides rising output power from modern power electronics devices. Nevertheless, the switch-mode operation results in EMI which is produced due to large di/dt and/or dv/dt. The methods to reduce EMI are the use of classic and expensive input filters or the addition of the active filter into the main circuits. In this paper, by using the randomized PWM the EMI effect can be reduced and implementation of the proposed control scheme into the forward converter can improve the harmonic spectrum as well

  • PDF

직접전력변환 방식을 이용한 전압 sag/swell 보상기의 구현 (Implementation of Voltage Sag/Swell Compensator Using Direct Power Conversion Method)

  • 차한주;이대동
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 B
    • /
    • pp.1014-1015
    • /
    • 2006
  • In this paper, a new single phase voltage sag/swell compensator using direct power conversion is introduced. A new compensator consists of input/output filter, series transformer and direct at-ac converter, which is a single-phase back-to-back PWM converter without dc-link capacitors. Advantages of the proposed compensator include: simple power circuit by eliminating dc-link electrolytic capacitors and thereby, improved reliability and increased life time of the entire compensator; simple PWM strategy to compensate voltage sag/swell at the same time and reduced switching losses in the ac-ac converter. Further, the proposed scheme is able to adopt simple switch commutation method without requiring complex four-step commutation method commonly required in the direct power conversion. Simulation results are shown to demonstrate the advantages of the new compensator and PWM strategy.

  • PDF

브리지형 PWM 변환기 전류제어를 위한 새로운 스위칭 방법의 응용 (Applications of A New Current Control witching Strategy for The Bridge Type PWM Converters)

  • 권병헌;오원석;조규민;인치각
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 B
    • /
    • pp.1182-1186
    • /
    • 2000
  • In many applications of the bridge type PWM converters as like inverters. AC/DC PWM converters or active power filters, it is necessary to control the input/output current. This paper presents a new current control switching strategy for the bridge type PWM converters. And variable speed motor control applications fed by current controlled inverter, PWM AC/DC converter applications. active power filter applications and class-D amplifier applications using the proposed new current control switching method are shown.

  • PDF

Design and Control of a Bidirectional Power Conversion System with 3-level T-type Inverter for Energy Storage Systems

  • Sung, Won-Yong;Ahn, Hyo Min;Oh, Chang-Yeol;Lee, Byoung Kuk
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권1호
    • /
    • pp.326-332
    • /
    • 2018
  • In this paper, the design process and the control method of the power conversion system (PCS) that consists of a bidirectional DC-DC converter and a 3-level T-type inverter for an energy storage system is presented. Especially the design method of the output LCL filter for a 3-lvel T-type inverter without complex mathematical process are proposed. The validity of the control method and design process in this paper are verified through simulation and experimental analysis.

비선형부하에 의해 발생한 전원 전류의 고조파를 제거하기 위한 단상 병렬형 Active Power Filter의 구현 (The Realization of a Single-Phase Parallel Active Power Filter to Eliminate Harmonics of Source Current Generated by Nonlinear Loads)

  • 장목순;이후찬;김상훈;박종연
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 A
    • /
    • pp.220-221
    • /
    • 2006
  • This paper presents a single-phase parallel active power filter with an analog control circuit to eliminate for harmonic source currents generated by nonlinear loads. The proposed system removes the harmonic source currents by injecting a compensation current that is 180' out of phase with the load harmonic current. The detection of the load harmonics is realized by a simple new structure, referred to the Notch Filter with GIC (Generalized Impedance Converter), which has higher Q than existing harmonic detecters and a simpler structure. The compensation current is obtained using the proposed harmonic detection circuit, DC-Link voltage, and output current of the full-bridge inverter controlled current mode PWM controller. The operation of the proposed system is verified experimentally.

  • PDF

국내외 PV PCS 기술현황 (Recent PV PCS Technology)

  • 최주엽;유권종;정영석;소정훈;최익
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2005년도 춘계학술대회
    • /
    • pp.117-122
    • /
    • 2005
  • This paper proposes an inverter for the grid-connected photovoltaic system based on the transformer-less inverter. This system consists of a high frequency converter bridge, high frequency transformer, diode bridge rectifiers, a DC filter, a low frequency inverter bridge, and an AC filter. The high frequency converter bridge switching at 20kHz is used to generate bipolar PWM pulse, and the high frequency transformer raise its voltage twice, which is subsequently rectified by diode bridge rectifiers to result in a full-wave rectified sine wave. Finally, it is unfolded by a low frequency inverter bridge to result in a 60Hz sine wave power output. Even though the high frequency link system needs more power semiconductors, a reduced size, light weight, and saved parts cost make this system more comparative than the other systems due to elimination of 60Hz transformer.

  • PDF

전자 나침반과 적외선 광원 추적을 이용한 이동로봇용 위치 인식 시스템 (Localization System for Mobile Robot Using Electric Compass and Tracking IR Light Source)

  • 손창우;이승희;이민철
    • 제어로봇시스템학회논문지
    • /
    • 제14권8호
    • /
    • pp.767-773
    • /
    • 2008
  • This paper presents a localization system based on the use of electric compass and tracking IR light source. Digital RGB(Red, Green, Blue)signal of digital CMOS Camera is sent to CPLD which converts the color image to binary image at 30 frames per second. CMOS camera has IR filter and UV filter in front of CMOS cell. The filters cut off above 720nm light source. Binary output data of CPLD is sent to DSP that rapidly tracks the IR light source by moving Camera tilt DC motor. At a robot toward north, electric compass signals and IR light source angles which are used for calculating the data of the location system. Because geomagnetic field is linear in local position, this location system is possible. Finally, it is shown that position error is within ${\pm}1.3cm$ in this system.

순간전압강하 보상기의 회로파라미터 설정 (The Circuit Parameters Determination of Voltage-Sag Compensator)

  • 김홍권;이은웅;임수생;김준호;전복수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 B
    • /
    • pp.795-797
    • /
    • 2000
  • The analysis model of voltage-sag compensator is achieved in synchronous rotating coordinates. Inverter's LC filter and DC-link capacitor is designed in order to reduce THD of output voltages and LC filter's size And the circuit parameters of voltage-sag compensator is presented for 3-phase Customer.

  • PDF

고조파 저감을 위한 단상 3-레벨 PWM 인버터 (Single-Phase 3-level PWM Inverter for Harmonics Reduction)

  • 강필순;박성준;김철우
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제51권3호
    • /
    • pp.125-132
    • /
    • 2002
  • This paper presents a single-phase 3-level PWM inverter to alleviate the harmonic components of output voltage and current under the conditions of identical supply DC voltage and switching frequency to the conventional inverter. Operational principles and analysis are performed, and the switching functions are derived. Deadbeat controller is also designed and implemented for the inverter to keep the output voltage being sinusoidal and to have the high dynamic performances even in the cases of load variations and the partial magnetization of filter inductor. The validity of proposed inverter is proved from the simulated and experimented results.