• 제목/요약/키워드: DC Circuit breaker

검색결과 85건 처리시간 0.029초

Operating characteristics of a superconducting DC circuit breaker connected to a reactor using PSCAD/EMTDC simulation

  • Kim, Geon-woong;Jeong, Ji-sol;Park, Sang-yong;Choi, Hyo-sang
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제23권3호
    • /
    • pp.51-54
    • /
    • 2021
  • The DC system has less power loss compared to the AC system because there is no influence of frequency and dielectric loss. However, the zero-crossing point of the current is not detected in the event of a short circuit fault, and it is difficult to interruption due to the large fault current that occurs during the opening, so the reliability of the DC breaker is required. As a solution to this, an LC resonance DC circuit breaker combined a superconducting element has been proposed. This is a method of limiting the fault current, which rises rapidly in case of a short circuit fault, with the quench resistance of the superconducting element, and interruption the fault current passing through the zero-crossing point through LC resonance. The superconducting current limiting element combined to the DC circuit breaker plays an important role in reducing the electrical burden of the circuit breaker. However, at the beginning of a short circuit fault, superconducting devices also have a large electrical burden due to large fault currents, which can destroy the element. In this paper, the reactor is connected to the source side of the circuit using PSCAD/EMTDC. After that, the change of the fault current according to the reactor capacity and the electrical burden of the superconducting element were confirmed through simulation. As a result, it was confirmed that the interruption time was delayed as the capacity of the reactor connected to the source side increased, but peak of the fault current decreased, the zero-crossing point generation time was shortened, and the electrical burden of the superconducting element decreased.

Comparison of HTS conductors for a DC resistive type fault current limiting module

  • So, Jooyeong;Lee, Seyeon;Choi, Kyeongdal;Lee, Ji-kwang;Kim, Woo-Seok
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제21권4호
    • /
    • pp.39-43
    • /
    • 2019
  • The breaking of a circuit in DC grid could pose a challenge because of the absence of zero-crossing instant for both current and voltage when a fault occurs. An additional fault current limiting function will be very helpful for reducing the burden of the DC circuit breaker by limiting the fault current to a reasonable value. In this paper, we studied the overcurrent characteristics of several HTS conductors so that we could use the selected conductors for the basic design work of a resistive type fault current limiting module as a part of the circuit breaking system. According to the short-circuit test results, we suggested and compared two different basic design parameters of the HTS fault current limiting module, which will be connected in series to the DC circuit breaker.

Current Limiting and Interrupting Operation of Hybrid Self-Excited Type Superconducting DCCB

  • Choi, S.J.;Lim, S.H.
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제20권4호
    • /
    • pp.55-59
    • /
    • 2018
  • Currently, the development of industry makes needs larger electric supply. Providers must consider the efficiency about losses and reliability of the system. In this case, DC power system can save electrical energy; long-distance transmission line losses. Relevance to switch technology with a voltage-source converter (VSC) in AC-DC conversion system have been researched. But, protection device of DC-link against fault current is still needed to study much. VSC DC power system is vulnerable to DC-cable short-circuit and ground faults, because DC-link has a huge size of capacitor filter which releases extremely large current during DC faults. Furthermore, DC has a fatal flaw that current zero crossing is nonexistence. To interrupt the DC, several methods which make a zero crossing is used; parallel connecting self-excited series LC circuit with main switch, LC circuit with power electronic device called hybrid DC circuit breaker. Meanwhile, self-excited oscillator needs a huge size capacitor that produces big oscillation current which makes zero crossing. This capacitor has a quite effective on the price of DCCB. In this paper, hybrid self-excited type superconducting DCCB which are using AC circuit breaker system is studied by simulation tool PSCAD/EMTDC.

직류전원을 이용한 배전급 차단기의 등가 3상 합성투입시험법 (Equivalent three-phase synthetic making test for medium voltage circuit breaker of distribution system using DC power)

  • 박병락;조만영;김진석;신희상;김재철
    • 조명전기설비학회논문지
    • /
    • 제25권7호
    • /
    • pp.105-113
    • /
    • 2011
  • The study about three-phase synthetic making test using DC power has been performed in order to increase the making test capacity on Vacuum Circuit Breaker. And, it made possible to solve the limitations that short-circuit testing facilities can not fulfill the testing requirements of VCB exceeding three-phase 36[kV] 31.5[kA]. By using DC power and high speed spark-gap switch, this method made the equivalence with the pre-arc that occurred during the making process under the fault condition of power system. As results, KERI(Korea Electrotechnology Research Institute) could have capacity to carry out type test for VCB under three-phase 52[kV] 40[kV], which satisfies the IEC Standard.

대체 카운터 전압(ACV) DC 하이브리드 회로 차단기(DC-HCB)의 EMTP 모델링 (EMTP Modeling of an Alterative Counter voltage (ACV) DC Hybrid Circuit Breaker (DC-HCB))

  • 라자무하마드카짐;이상봉
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2015년도 제46회 하계학술대회
    • /
    • pp.601-602
    • /
    • 2015
  • Interruption of AC is easier due to natural occuring of zero crossings. In DC, zero crossings is achieved by Forced commutation technique. In this paper an alternative counter voltage(ACV) DC Hybrid Circuit breaker(DC-HCB) is modeled using EMTP/ATP tool, Results show that, ACV DC-HCB can interrupt DC with in 5ms with a source voltage of upto 1 KV.

  • PDF

DC 그리드 안정성 향상을 위해 변압기형 초전도 한류기가 적용된 직류 차단 기술에 관한 연구 (A Study on DC Interruption Technology using a Transformer Type Superconducting Fault Current Limiter to Improve DC Grid Stability)

  • 황선호;최혜원;정인성;최효상
    • 전기학회논문지
    • /
    • 제67권4호
    • /
    • pp.595-599
    • /
    • 2018
  • Interruption system with the transformer type superconducting fault current limiter(TSFCL) is proposed in this paper. The interruption system with a TSFCL is a technology that it maximizes the interruption function of a mechanical DC circuit breaker using a transformer and a superconducting fault current limiter. By a TSFCL, the system limits the fault current till the breakable current range in the fault state. Therefore, the fault current could be cut off by a mechanical DC circuit breaker. The Interruption system with a TSFCL were designed using PSCAD/EMTDC. In addition, the Interruption system with a TSFCL was applied to the DC test circuit to analyze characteristics of a current-limiting and a interruption operation. The simulation results showed that the Interruption system with a TSFCL interrupted the fault current in a stable when a fault occurred. Also, The current-limiting rate of the Interruption system with a TSFCL was approximately 69.55%, and the interruption time was less than 8 ms.

전기철도 변전소의 직류고속도차단기 동작 감소방안에 관한 연구 (A Study on the DC High Speed Circuit Breaker(HSCB) in Electric Railway Substation System)

  • 허태복;김학련;창상훈
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2004년도 추계학술대회 논문집
    • /
    • pp.1303-1308
    • /
    • 2004
  • This paper proposes a reduction method for the mis-operation analysis of the DC High Speed Circuit Breaker(HSCB) in electric railway substation system. The analysis method is based on present condition of operation which is a method for accuracy level up. There is reason to operation of HSCB that it is mis-operation of fault detection relay(50F), operation of ground fault relay(64P), and trouble of electric car. A countermeasure is relay resetting through field test, induction of GTOCB(Gate Turn Off Thyristor Circuit Breaker), HSVCB(High Speed Vacuum Circuit Breaker), coordination with electric car. The results presented in the paper can be used as a reference for maintenance free in electric railway substation system.

  • PDF

직류철도 급전계통의 안전성 향상을 위한 차단기 동작 최적 설정의 실험적 고찰 (An Experimental Study on Operation Setting Optimization of Circuit Breaker for Improving Safety on DC Railroad Feeder System)

  • 이재봉;정노건;김재문
    • 전기학회논문지
    • /
    • 제65권3호
    • /
    • pp.526-531
    • /
    • 2016
  • This paper presents an experimental study on the optimal settings for the selected DC fault relay (50F) to improve the operating performance for the high-speed circuit breaker on DC feeding system which ensure safety within rolling stock maintenance depot. In this study, current supplied to overhead contact wire was calculated on 1 ms interval to analyze the correction values of DC fault selective relay for the operation of current supply cutout. Particularly, standards for the accurate detection of accidents between an electric railway vehicle and the electric power facilities are shown by investigating the optimal correction values for detection of fault current, and the results indicated that it takes about 213 ms for the DC fault selective relay(50F) to fully open. In the future, the correction values of DC fault selective relay suggested in this paper will be used as the reference values of protective relay for the safe operation of DC electric railroad system such as urban railway.

개극시간 조정회로를 삽입한 축소형 가스절연 차단기 (Compact Gas-Insulated Circuit-Breaker adopting opening-time control circuits)

  • 김정배;김두성;서경보;양대일;송원표;김맹현;고희석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 A
    • /
    • pp.485-487
    • /
    • 2004
  • High-voltage gas-insulated circuit-breaker must interrupt short-circuit current successfully when breakdown occurs in electric power system. Among many test-duties, Basic Terminal fault T100a(BTF T100a) is the one of the severest duties because of its high DC component of short-circuit current. In this paper, we developed 245kV 50kA gas circuit breaker using control circuits to reduce DC component while interrupting short-circuit current, then got good performance through high-power tests in Korea Electrotechnology Research Institute(KERI) and KEMA

  • PDF

Z-source 직류 차단기의 기계식 스위치 적용을 위한 최적화 설계 (Optimization Design for the Use of Mechanical Switch in Z-source DC Circuit Breaker)

  • 이현승;이건아
    • 한국안전학회지
    • /
    • 제37권1호
    • /
    • pp.12-19
    • /
    • 2022
  • Circuit breakers are a crucial factor in ensuring the safety of a Direct Current (DC) grid. One type of DC circuit breaker, the Z-source DC circuit breaker (ZCB), uses a thyristor, which is a type of semiconductor switch. In the event of a fault in the circuit, the ZCB isolates the fault by generating a zero crossing current in the thyristor. The thyristor quickly and actively isolates the fault while generating a zero crossing current, but thyristor switch cannot control turn-off and the allowable current is lower than the current of the mechanical switch. Therefore, it is best to use a mechanical switch with a high allowable current capacity that is capable of on/off control. Due to the slow reaction time of mechanical switches, they may not isolate the fault during the zero crossing current time interval created by the existing circuit. In this case, the zero crossing current time can be increased by using the property that hinders the rapid change in the current of the inductor. This paper will explore whether adding system inductance to increase the zero crossing current time interval is a solution to this problem. The simulation of changing inductor and capacitor (LC) of the circuit is repeated to find an optimal change in the zero crossing current time according to the LC change and provides an inductor and capacitor range optimized for a specific load. The inductor and capacitor range are expected to provide optimization information in the form LC values for future applications of ZCB's using a mechanical switch.