• 제목/요약/키워드: DC Chopper

검색결과 136건 처리시간 0.027초

PWM chopper 에 의한 태양전지의 출력제어 (Output control of solar cells using PWM chopper)

  • 유권종;김용식;박이준;송진수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1990년도 하계학술대회 논문집
    • /
    • pp.401-404
    • /
    • 1990
  • A new control method of solar cell output using PWM chopper is described. Theoretical analysis and comparision for all sorts of system are also discussed for improving photovoltic system efficiency. It is expected that the result of this study will be utilized to some other DC or AC application equipments.

  • PDF

상태평균화법에 의한 직류초퍼구동 DC모터 제어시스템의 해석과 설계에 관한 연구 (A study on the analysis and design of the chopper fed DC Motor control system using state space averaging method)

  • 유권종;김용주;김한성
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1990년도 추계학술대회 논문집 학회본부
    • /
    • pp.352-356
    • /
    • 1990
  • In this paper proposed a new analysis method that can be controlled DC separately excited motor using DC chopper. An analysis method can be broadly divided the state variables method and the state space averaging method. The state variable method is largely used for analysis method in the time area, but it is complicated analysis of the nonlinear circuit and modeling of the system. Therefore a boundary of the current continuous mode and discontinuous mode can be definited by the state space averaging method. Also this paper proposed a new approximation analysis method using state space averaging method in the discontinuous mode.

  • PDF

초퍼제어 - 직류전동기의 PSPICE 컴퓨터 시뮬레이션 (Pspice Computer Simulation of Chopper Controlled DC Motor)

  • 원충연;김덕헌;유홍제;유동욱
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1991년도 하계학술대회 논문집
    • /
    • pp.37-42
    • /
    • 1991
  • In this paper, the authors describe the equivalent circuit for a DC motor in consideration of both magnetic saturation and armature reaction phenomena. To develop DC motor model in PSPICE is to eliminate the gap between drive electronics and models of driven machine. On the basis of these results the dynamic characteristics of a MOSFET chopper controlled DC series motor are investigated by PSPICE simulation and experiment.

  • PDF

승강압초퍼와 부부공진 인버터를 이용한 계통연계형 태양광 발전시스템 (Utility interactive PV system using buck-boost chopper and partial resonant Inverter)

  • 고강훈;이현우;김영철;정명웅;홍두성
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1999년도 전력전자학술대회 논문집
    • /
    • pp.278-281
    • /
    • 1999
  • In a utility interactive photovoltaic system, a PWM inverter is used for the connection between the photovoltaic arrays and the utility. The DC current becomes pulsated causes the distortion of the AC current waveform. This paper presents the reduced pulsation of DC input current by operating the inverter with buck-boost chopper in the discontinuous conduction mode. The DC current with contains harmonics component is analyzed by means of separating into two terms of a ripple component and a direct component. The constant DC current without pulsation is supplied from photovoltaic array to the inverter. The proposed inverter system provide a sinusoidal AC current for domestic loads and the utility line with unity power factor.

  • PDF

2상 쵸퍼 Preregulator를 갖는 12-step 인버터에서의 DC Link단 전압 불평형 해석 (Analysis of the Unbalance of DC Link Voltage in 12-step Inverter with 2-Phase Chopper Preregulator)

  • 노의철;김인동
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 추계학술대회 논문집 학회본부
    • /
    • pp.258-260
    • /
    • 1995
  • This paper deals with the voltage unbalance of DC link voltage in series connected two 6-step inverters with double chopper preregulator. Each output of the 6-step inverter is connected to each transformer. The secondary windings of one of the transformers is zig-zag connected and the other star connected. The secondary terminals of the two transformers are series connected which makes 12-step output voltage waveform. In this case, the characteristics of the two transformers are rather different each other. The difference results in the voltage unbalance of the two 6-step inverter input capacitor voltages which make the DC link voltage. The degree of the voltage unbalance is analysied with the variations of load power, load power factor and % impedance of the transformer.

  • PDF

불연속모드 승강압초퍼를 이용한 계통연계형 태양광발전 시스템 (Utility Interactive Photovoltaic Generation System Using Discontinuous Mode Buck-Boost Chopper)

  • 김영철;이현우;서기영
    • 전력전자학회논문지
    • /
    • 제4권4호
    • /
    • pp.325-331
    • /
    • 1999
  • 계통연계형 태양광발전시스템에서는 계통과 태양광시스템을 연계하기 위해 PWM 인버터가 이용된다. 인버터 시스템을 연속전류모드로 운전하면 맥동이 발생하게 되고, 직류전류의 맥동발생은 교류전류파형의 왜형을 가져온다. 본 연구에서는 직류입력전류의 맥동을 감소시키기 위하여 불연속모드 승강압초퍼로 인버터를 운전한다. 직류 전류에 포함된 고조파성분을 리플성분과 직류성분으로 분리하여 해석하고, 맥동이 없는 일정한 직류전류를 태양 전지로부터 인버터로 공급한다. 제안하는 인버터시스템은 단위 역률로 부하와 계통에 교류전류를 공급한다.

  • PDF

DC chopper용 전류회로 개선에 관한 연구 (A study on the improvement of communiation circuit for DC chopper)

  • 노창주;오진석
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제13권1호
    • /
    • pp.57-68
    • /
    • 1989
  • This paper treats the analytical and experimental studies on the improvement of commutating circuit for the speed control of DC motor. A simple circuit composed of R, L and C elements is proposed here for switching off power SCR carrying the load current. The real important in this chopper circuit is to determine the reasonable values of commutating circuit constants. In this paper, the reasonable values of the commutating circuit constants are basically determined on a view point of commutating performances in the given circuit model and must satisfy the following conditions. The first, the peak commutating current should be larger than the anticipated maximum load current. The second, the circuit turn-off time (tc) must be longer than the SCR turn-off time (tq). The third, the resistor should be enough large to permit the current to be neglected in the analysis of the commutation circuit, as well as be enough small to permit to charge the capacity voltage (Ec) to the half the value of source voltage (E) before the next communication cycle is initiated. The last, the period of chopping signal must be the least possible multiple of the damping vibration period of commutating circuit. The improved chopper circuit used in the experiment under unloaded condition was composed to meet the reasonable conditions mentioned above, and a successful commuting performance was achieved without failure. Several types of microprocessor having a different value of CPU speed individually have been applied to the experiment under the loaded conditions. Also it shows that the faster the speed of CPU is, the more stable the commutation turns out.

  • PDF

Two Paralleled Four Quadrant DC Chopper for Gradient Coil Magnetic Fields in MRI System

  • Park, Hyung-Beom;Mun, Sang-Pil;Park, Han-Seok;Woo, Kyung-Il
    • 조명전기설비학회논문지
    • /
    • 제23권11호
    • /
    • pp.22-27
    • /
    • 2009
  • This paper presents a two-paralleled four quadrant DC chopper type PWM power conversion circuit in order to generate a gradient magnetic field in the Magnetic Resonance Imaging (MRI) system. This circuit has 8-IGBTs at their inputs/outputs to realize further high-power density, high speed current tracking control, and to get a low switching ripple amplitude in a controlled current in the Gradient Coils (GCs). Moreover, the power conversion circuit has to realize quick rise/fall response characteristics in proportion to various target currents in GCs. It is proposed in this paper that a unique control scheme can achieve the above objective DSP-based control system realize a high control facility and accuracy. It is proved that the new control system will greatly enlarge the diagnostic target and improve the image quality of MRI.

Boost Type ZVS-PWM Chopper-Fed DC-DC Power Converter with Load-Side Auxiliary Resonant Snubber and Its Performance Evaluations

  • Ogura, Koki;Chandhaket, Srawouth;Ahmed, Tarek;Nakaoka, Mutsuo
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • 제3B권3호
    • /
    • pp.147-154
    • /
    • 2003
  • This paper presents a high-frequency boost type ZVS-PWM chopper-fed DC-DC power converter with a single active auxiliary edge-resonant snubber at the load stage which can be designed for power conditioners such as solar photovoltaic generation, fuel cell generation, battery and super capacitor energy storages. Its principle operation in steady-state is described in addition to a prototype setup. The experimental results of boost type ZVS-PWM chopper proposed here, are evaluated and verified with a practical design model in terms of its switching voltage and current waveforms, the switching v-i trajectory and the temperature performance of IGBT module, the actual power conversion efficiency, and the EMI of radiated and conducted emissions, and then discussed and compared with the hard switching scheme from an experimental point of view. Finally, this paper proposes a practical method to suppress parasitic oscillation due to the active auxiliary resonant switch at ZCS turn-off mode transition with the aid of an additional lossless clamping diode loop, and can be reduced the EMI conducted emission.

동기기를 사용한 계통연계형 가변속 풍력발전 시스템의 AC-DC-AC 컨버터 구현 및 제어 (Implementation and Control of AC-DC-AC Power Converter in a Grid-Connected Variable Speed Wind Turbine System with Synchronous Generator)

  • 송승호;김성주;함년근
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제54권12호
    • /
    • pp.609-615
    • /
    • 2005
  • A 30kW electrical power conversion system is developed for a variable speed wind turbine. In the wind energy conversion system(WECS) a synchronous generator with field current excitation converts the mechanical energy into electrical energy. As the voltage and the frequency of the generator output vary according to the wind speed, a 6-bridge diode rectifier and a PWM boost chopper is utilized as an ac-dc converter maintaining the constant dc-link voltage with only single switch control. An input current control algorithm for maximum power generation during the variable speed operation is proposed without any usage of speed sensor. Grid connection type PWM inverter converts dc input power to ac output currents into the grid. The active power to the grid is controlled by q-axis current and the reactive power is controlled by d-axis current with appropriate decoupling. The phase angle of utility voltage is detected using software PLL(Phased Locked Loop) in d-q synchronous reference frame. Experimental results from the test of 30kW prototype wind turbine system show that the generator power can be controlled effectively during the variable speed operation without any speed sensor.