• 제목/요약/키워드: DC/AC inverter

검색결과 458건 처리시간 0.035초

On the Design of Power Supply System for Freight Train Reefer Container Based on Simulation

  • Kim, Joouk;Hwang, Sunwoo;Lee, Jae-Bum;Hwang, Jaemin;Chae, Uri
    • International Journal of Internet, Broadcasting and Communication
    • /
    • 제14권3호
    • /
    • pp.249-257
    • /
    • 2022
  • In recent years, if we order food by easily accessing the online market with our smartphone, we can receive the product in a fresh state at dawn the next day. Cold chain is an industry that can create high added value because it has both the characteristics of general logistics and sensitivity to temperature. Based on the electrical specifications derived from the reefer container capacity requirement investigation, we proved that power supply to up to 33 reefer containers can be made by using three additional auxiliary power supplies which are applied for freight trains in Korea. In this paper, we conducted a research on a design of power supply system for freight train reefer container based on simulation as a basic research necessary for low-temperature distribution and cold chain construction based on the reefer container railroad. Consequently, the simulation was conducted using the three-phase inverter diagram in PSIM and the SVPWM (3-harmonic injection method) control technique, and it was verified that the required power voltage was satisfied with 622Vdc, which is lower than the input voltage of general SPWM of 718Vdc. The details of this paper could be used as a foundational study for constructing cold chains based on a reefer container dedicated to freight trains in the future.

풍력발전의 최대전력점 추종제어 방법에 관한 연구 (A study on the Maximum Power Point Tracking Control System of Wind Power Generation)

  • 고석철;이재;임성훈;강형곤;한병성
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 추계학술대회 논문집 Vol.14 No.1
    • /
    • pp.153-156
    • /
    • 2001
  • Maximum Power Point Tracking(MPPT) is used in wind power generation systems to maximize wind power turbin output power, irrespective of wind speed conditions and of the load electrical characteristics. In this paper we do the equivalent modeling the mechanical energy of wind power turbine according to wind speed into the synchronous generator. We analyse the equivalent modeling output part of rectifier into DC/DC converter input part theoretically. We design a control algorithm for variable voltage according to wind speed intensity and density so that load voltage of chopper is controlled steadily using the maximum power point tracking (MPPT) control method. We analyse a battery charging characteristics and a charging circuit for power storage enabling the supply of stable power to the load. We design a system and do the modeling of it analytically so that it supplies a stable power to the load by constructing a DC-AC inverter point. Also we design a charging circuit usable in actual wind power generation system of 30kW and confirm its validity.

  • PDF

풍력발전의 전력저장을 위한 베터리 충전회로에 관한 수학적인 모델링 (A Mathematical Modeling on Battery Charging Circuit for the Power Storage of Wind Power Generation)

  • 고석철;이재;임성훈;강형곤;한병성
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.301-304
    • /
    • 2001
  • Wind power generation system is one of the most useful energy resource using natural environment. One of the biggest problem we encountered is toot the wind speed is fluctuating sharply according to the weather conditions rather than it is stable. In this paper we do the equivalent modeling the mechanical energy of wind power turbine according to wind speed into the synchronous generator. We analyse the equivalent modeling output part of rectifier into DC/DC converter input part theoretically. We analyse a battery charging characteristics for power storage enabling the supply of stable power to the load. We design a system and do the modeling of it analytically so that it supplies a stable power to the load by constructing a DC-AC inverter point. Also we make a small size model usable in actual wind power generation system of 30kw and make an experiment and confirm its validity.

  • PDF

풍력발전의 최대전력점 추종제어 방법에 관한 연구 (A study on the Maximum Power Point Tracking Control System of Wind Power Generation)

  • 고석철;이재;임성훈;강형곤;한병성
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 추계학술대회 논문집
    • /
    • pp.153-156
    • /
    • 2001
  • Maximum Power Point Tracking(MPPT) Is used in wind power generation systems to maximize wind power turbin output power, irrespective of wind speed conditions and of the load electrical characteristics. In this paper we do the equivalent modeling the mechanical energy of wind power turbine according to wind speed into the synchronous generator. We analyse the equivalent modeling output part of rectifier into DC/DC converter input part theoretically. We design a control algorithm for variable voltage according to wind speed intensity and density so that load voltage of chopper is controlled steadily using the maximum power point tracking(MPPT) control method. We analyse a battery charging characteristics and a charging circuit for power storage enabling the supply of stable power to the load. We design a system and do the modeling of it analytically so that it supplies a stable power to the load by constructing a DC-AC inverter point. Also we design a charging circuit usable in actual wind power generation system of 30kW and confirm its validity.

  • PDF

단상 PVPCS 출력 전류의 리플 개선을 위한 노치 필터 및 피드 포워드 제어기 설계 (The Feed-forward Controller and Notch Filter Design of Single-Phase Photovoltaic Power Conditioning System for Current Ripple Mitigation)

  • 김승민;양승대;최주엽;최익;이영권
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2012년도 춘계학술발표대회 논문집
    • /
    • pp.325-330
    • /
    • 2012
  • A single-phase PVPCS(photovoltaic power conditioning system) that contains a single phase dc-ac inverter tends to draw an ac ripple current at twice the out frequency. Such a ripple current may shorten passive elements life span and worsen output current THD. As a result, it may reduce the efficiency of the whole PVPCS system. In this paper, the ripple current propagation is analyzed, and two methods to reduce the ripple current are proposed. Firslyt, this paper presents notch filter with IP voltage controller to reject specific current ripple in single-phase PVPCS. The notch filter can be designed that suppress just only specific frequency component and no phase delay. The proposed notch filter can suppress output command signal in the ripple bandwidth for reducing output current THD. Secondly, for reducing specific current ripple, the other method is feed-forward compensation to incorporate a current control loop in the dc-dc converter. The proposed notch filter and feed-forward compensation method have been verified with computer simulation and simulation results obtained demonstrate the validity of the proposed control scheme.

  • PDF

원자력발전소 직류전원계통용 축전지 성능시험 분석 (Analysis of Battery Performance Test for DC Power System in Nuclear Power Plant)

  • 김대식;차한주
    • 전기학회논문지P
    • /
    • 제63권2호
    • /
    • pp.61-68
    • /
    • 2014
  • Function of battery bank stores energy for DC load in general, and DC power system of the nuclear power plant is used to supply DC loads for safety- featured instrumentation and control such as inverter, class 1E power system control and indication, and station annunciation. Class 1E DC power system must provide a power for the design basis accident conditions, and adequate capacity must be available during loss of AC power and subsequent safe shutdown of the plant. In present, batteries of Class 1E DC power system of the nuclear power plant uses lead-acid batteries. Class 1E batteries of nuclear power plants in Korea are summarized in terms of specification, such as capacity, discharge rate, bank configuration and discharge end voltage, etc. This paper summarizes standards of determining battery size for the nuclear power plant, and analyzes duty cycle for the class 1E DC power system of nuclear power plant. Then, battery cell size is calculated as 2613Ah according to the standard. In addition, this paper analyzes performance test results during past 13 years and shows performance degradation in the battery bank. Performance tests in 2001 and 2005 represent that entire battery cells do not reach the discharge-end voltage. Howeyer, the discharge-end voltage is reached in 14.7% of channel A (17 EA), 13.8% of channel B (16 EA), 5.2% of channel C (6 EA) and 16.4% of channel D (19 EA) at 2011 performance test. Based on the performance test results analysis and size calculation, battery capacity and degradation by age in Korearn nuclear power plant is discussed and would be used for new design.

직류단 전압의 고조파 맥동 검출을 이용한 3상 다이오드 정류기의 고장 진단 (Fault Diagnosis for 3-Phase Diode Rectifier using Harmonic Ripples of DC Link Voltage)

  • 박제욱;백승원;김장목;이동춘;이교범
    • 전력전자학회논문지
    • /
    • 제16권5호
    • /
    • pp.457-465
    • /
    • 2011
  • 본 논문에서는 3상 다이오드 정류기의 고장에 따른 해석 및 고장 판별 기법을 제안한다. 입력전원이나 다이오드소자에 고장이 발생하게 되면 출력 직류단 전압에 큰 맥동을 유발하며 이는 인버터 시스템의 제어 성능을 저하시킬 뿐만 아니라 커패시터의 수명 단축을 야기한다. 본 논문에서는 입력측의 지락 사고 및 다이오드 개방 사고 시의 직류단 전압 특성을 분석하고, 계통주파수의 6배에 주파수마다 측정된 직류단의 순시전압을 직류단 평균 전압과 비교함으로서 고장의 유무 및 종류를 판별하는 알고리즘을 제안하였다. 제안한 알고리즘은 직류단 전압 센서만을 이용하므로 구현이 간단하고 고장 진단을 위한 추가적인 하드웨어가 요구되지 않는다. 실험과 시뮬레이션을 통해 제안한 고장 진단 알고리즘의 타당성을 검증하였다.

새로운 벡터적 PLL를 이용한 대용량 무효전력 보상기(SVC)의 DSP 제어 (DSP BASED CONTROL OF HIGH POWER STATIC VAR COMPENSATOR USING NOVEL VECTOR PRODUCT PHASE LOCKED LOOP)

  • 정구호;조국춘;채균;조규형
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 A
    • /
    • pp.262-264
    • /
    • 1996
  • This paper presents a new dual loop control using novel vector phase locked loop(VP-PLL) for a high power static var compensator(SVC) with three-level GTO voltage source inverter(VSI). Through circuit DQ-transformation, a simple dq-axis equivalent circuit is obtained. From this, DC analysis is carried out to obtain maximum controllable phase angle ${\alpha}_{max}$ per unit current between the three phase source and the switching function of inverter, and AC open-loop transfer function is given. Because ${\alpha}_{max}$ becomes small in high power SVC, this paper proposes VP-PLL for more accurate $\alpha$-control. As a result, the overall control loop has dual loop structure, which consists of inner VP-PLL for synchronizing the phase angle with source and outer Q-loop for compensating reactive power of load. Finally, the validity of the proposed control method is verified through the experimental results.

  • PDF

Enhanced Startup Diagnostics of LCL Filter for an Active Front-End Converter

  • Agrawal, Neeraj;John, Vinod
    • Journal of Power Electronics
    • /
    • 제18권5호
    • /
    • pp.1567-1576
    • /
    • 2018
  • The reliability of grid-connected inverters can be improved by algorithms capable of diagnosing faults in LCL filters. A fault diagnostic method during inverter startup is proposed. The proposed method can accurately generate and monitor information on the peak value and the location of the peak frequency component of the step response of a damped LCL filter. To identify faults, the proposed method compares the evaluated response with the response of a healthy higher-order damped LCL filter. The frequency components in the filter voltage response are first analytically obtained in closed form, which yields the expected trends for the filter faults. In the converter controller, the frequency components in the filter voltage response are computed using an appropriately designed fast Fourier transform and compared with healthy LCL response parameters using a finite state machine, which is used to sequence the proposed startup diagnostics. The performance of the proposed method is validated by comparing analytical results with the simulation and experimental results for a three-phase grid-connected inverter with a damped LCL filter.

태양광 발전용 전력변환장치에 관한 연구 (A Study on Power Conversion System for Photovoltaic Generation)

  • 박정환;장수형;이성근;안병원;김윤식
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2001년도 춘계종합학술대회
    • /
    • pp.437-442
    • /
    • 2001
  • 계통연계형 태양광 발전 시스템은 태양 에너지를 전기 에너지로 변환하는 태양 전지부와 발생 전력을 계통에 연계하는 진력변환장치로 크게 나눌 수 있다. 또한 전력변환부는 승압용 컨버터부와 DC전력을 AC로 변환하는 인버터부로 구성된다. 종래 인버터의 주회로 방식은 저주파 트랜스나 고주파 트랜스를 사용하는 방식이 채러되었으나, 최근 이러한 방식에 비해 소형 경량화가 기대되는 트랜스리스 방식이 많이 연구되고 있다. 본 논문의 승압부는 2상 부스트 컨버터를 이용하여 입력 전류와 출력 전압의 리플을 줄여, 각 전력 소자의 전압 스트레스를 줄이고, 입력 리액터를 소형화한다. 그리고, 인버터 부의 출력 고조파 성분을 저감하기 위해 정현파 PWM에서 얻어진 스위칭 시간을 기본값으로 하여 푸리에 급수로 유도한 PWM 스위칭 시간을 채택하였고, PSpice를 이용하여 변환기의 동작을 시뮬레이션하여 그 유효성을 검증하였다.

  • PDF