• Title/Summary/Keyword: DAQ

Search Result 168, Processing Time 0.027 seconds

An Effective Teaching Plan based on the LabVIEW by utilizing the USB type DAQ device (LabVIEW 기반의 USB방식 DAQ장비를 활용한 효과적인 수업 방안)

  • Bae, Joon-Young;Kim, Nam-Sung
    • The Journal of Korean Institute for Practical Engineering Education
    • /
    • v.2 no.2
    • /
    • pp.91-98
    • /
    • 2010
  • In this paper, we looked around an effective teaching plan base on the LabVIEW by utilizing the USB type DAQ device. Moreover, we have been learning the concept of control and instrumentation engineering through theory and practice classwork in the various field of engineering, come to automation engineering as well as electricity, electronic, telecommunication and computer science. In case of the best learning to understand the concept and operate the practice, we'd like to propose the application technique to make use of the PC based on LabVIEW software with USB type DAQ devices, better than to depend upon the expensive equipment as before. As a result, we hope that this technique to be considered easily accessible to understand anyone and expect distinguished applications.

  • PDF

Development of H/W and S/W for Detecting Electrical Fire Precursor Signal on Electrical Wirings (배선에서 전기화재 전조신호 검출을 위한 H/W 및 S/W 구축)

  • Kim, Sung-Chul;Kim, Doo-Hyun
    • Journal of the Korean Society of Safety
    • /
    • v.24 no.3
    • /
    • pp.13-18
    • /
    • 2009
  • This paper is purposed to develop DAQ H/W, S/W and DB which can be used in developing electrical fire alarm system or in analyzing electrical fire cause, by detecting and monitoring precursor signals which have high possibility leading to electrical fire on electrical distribution wires. In this paper, developed was DAQ H/W adopting the C8051FXXX CPU which can analyze the measurement signals of current and voltage in electrical distribution wires, other CPU was investigated in view of the best digital sampling rate on the basis of previous researches for electrical fire alarm system. Also, the S/W which can interface with DAQ H/W's communication protocol and can be applied for electrical fire causes analysis, are embodied by LabVIEW. The combined DAQ H/W and S/W could analyze efficiently normal as well as abnormal electrical signals such as RMS value, instantaneous value of current and voltage, frequency signals etc, on the electrical wires. Also, DB system was constructed for recording various analysis results for precursor signals including voltage and current signals. The results by simulator and experiment showed that the suggested scheme with DAQ H/W, S/W and DB in this paper has high usability.

A Study on the Combination of the Existing Monitoring System with the Safety Management Network System (기구축 계측시스템의 안전관리 네트워크 시스템 연계 방안에 관한 연구)

  • Lee, Chin-Hyung;Park, Ki-Tae;You, Young-Jun;Joo, Bong-Chul;Hwang, Yoon-Koog;Bae, In-Hwan
    • Journal of Korean Society of societal Security
    • /
    • v.2 no.3
    • /
    • pp.47-53
    • /
    • 2009
  • This study performed the construction of test bed for the combination of the health monitoring system In Yongjong grand bridge with the safety management network system in order to explore the feasibility of combining the existing monitoring system with the safety management network system. For this purpose, connection program which consists of DAQ sender server program and DAQ receiver server program has been developed. DAQ sender server program installed in the connection server, which is located on the DMZ zone of the existing monitoring system, plays the role of communicating with the monitoring system. On the other hand, DAQ receiver server program installed in the connection server, which is located on the integrated operation center of the safety management network system, plays the part of gathering real time and tim history data of the existing monitoring system and storing them in the integrated operation server through the communication with the DAQ sender. Test bed demonstrated the feasibility of combining the existing monitoring system with the safety management network system.

  • PDF

Development of simultaneous multi-channel data acquisition system for large-area Compton camera (LACC)

  • Junyoung Lee;Youngmo Ku;Sehoon Choi;Goeun Lee ;Taehyeon Eom ;Hyun Su Lee ;Jae Hyeon Kim ;Chan Hyeong Kim
    • Nuclear Engineering and Technology
    • /
    • v.55 no.10
    • /
    • pp.3822-3830
    • /
    • 2023
  • The large-area Compton camera (LACC), featuring significantly high detection sensitivity, was developed for high-speed localization of gamma-ray sources. Due to the high gamma-ray interaction event rate induced by the high sensitivity, however, the multiplexer-based data acquisition system (DAQ) rapidly saturated, leading to deteriorated energy and imaging resolution at event rates higher than 4.7 × 103 s-1. In the present study, a new simultaneous multi-channel DAQ was developed to improve the energy and imaging resolution of the LACC even under high event rate conditions (104-106 s-1). The performance of the DAQ was evaluated with several point sources under different event rate conditions. The results indicated that the new DAQ offers significantly better performance than the existing DAQ over the entire energy and event rate ranges. Especially, the new DAQ showed high energy resolution under very high event rate conditions, i.e., 6.9% and 8.6% (for 662 keV) at 1.3 × 105 and 1.2 × 106 s-1, respectively. Furthermore, the new DAQ successfully acquired Compton images under those event rates, i.e., imaging resolutions of 13.8° and 19.3° at 8.7 × 104 and 106 s-1, which correspond to 1.8 and 73 μSv/hr or about 18 and 730 times the background level, respectively.

Using Requirements Engineering to support Non-Functional Requirements Elicitation for DAQ System

  • Kim, Kyung-Sik;Lee, Seok-Won
    • Journal of the Korea Society of Computer and Information
    • /
    • v.26 no.3
    • /
    • pp.99-109
    • /
    • 2021
  • In recent machine learning studies, in order to consider the quality and completeness of data, derivation of non-functional requirements for data has been proposed from the viewpoint of requirements engineering. In particular, requirements engineers have defined data requirements in machine learning. In this study, data requirements were derived at the data acquisition (DAQ) stage, where data is collected and stored before data preprocessing. Through this, it is possible to express the requirements of all data required in the existing DAQ system, the presence of tasks (functions) satisfying them, and the relationship between the requirements and functions. In addition, it is possible to elicit requirements and to define the relationship, so that a software design document can be produced, and a systematic approach and direction can be established in terms of software design and maintenance. This research using existing DAQ system cases, scenarios and use cases for requirements engineering approach are created, and data requirements for each case are extracted based on them, and the relationship between requirements, functions, and goals is illustrated through goal modeling. Through the research results, it was possible to extract the non-functional requirements of the system, especially the data requirements, from the DAQ system using requirements engineering.

Development of a Rapid Control Prototyping System Based on Matlab and USB DAQ boards (Matlab과 USB DAQ 장치를 이용한 Rapid Control Prototyping System 개발)

  • Lee, Young-Sam;Yang, Ji-Hyuk;Kim, Seuk-Yun;Kim, Won-Sik;Kwon, Oh-Kyu
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.18 no.10
    • /
    • pp.912-920
    • /
    • 2012
  • In this paper, we propose a new and cost-effective RCP (Rapid Control Prototyping) system based on Matlab/Simulink and a DAQ (Data Acquisition) unit with the high speed USB communication interface. The proposed RCP system has a feature that a computer on which Simulink is running acts as a realtime controller and a DAQ unit performs data acquisition, transmission of the data to and from a computer, and the application of control data received from the computer. For its implementation, we develop 10 communication blocks each of which is constructed by using S-function. In order to increase the data communication speed and thus to reduce the sampling period of the overall control system, we propose to use a batch transfer strategy through the USB interface. The proposed RCP system has several advantages over existing methods such as good maintainability, portability due to the USB interface, low cost, and no necessity for C-code generation even though it can only be applied to control systems with moderate sampling rates. It is expected that the proposed RCP system can be useful in teaching control-related topics to undergraduate and graduate students.

Tele-Operating DAQ System for Bio-Inspired Robots (생체모방로봇 제어를 위한 원격 DAQ 시스템)

  • Oh, Seung-Yeop;Choi, Jae-Sung;Son, Byung-Rak;Lee, Dong-Ha;Yoo, Joon-Hyuk
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2012.06a
    • /
    • pp.274-275
    • /
    • 2012
  • 생체모방로봇은 인간을 비롯하여 새, 곤충, 물고기 등 동물들의 기본구조, 행동원리 및 메커니즘을 모방한 로봇이다. 정찰, 수색, 테러진압 등 군사작전에서부터 인명구조까지 생체모방로봇은 인간의 눈과 발을 대신하여 인간이 접근할 수 없는 오염 지역을 면밀히 탐지하는 데에도 유용하리라 예상된다. 이와 같은 생체모방로봇이나 MAV 등을 실시간으로 원격에서 모니터링하고 제어할 수 있는 DAQ 시스템의 중요성이 커지고 있다. 본 논문에서는 생체모방로봇인 가오리를 원격 관제 센터에서 RF무선통신을 이용하여 안정적인 제어 및 모니터링이 가능한 DAQ(Data AcQuisition) 시스템을 제안한다.

Supercapacitive Properties of Composite Electrode Consisting of Activated Carbon and Di(1-aminopyrene)quinone

  • Kim, Kwang Man;Lee, Young-Gi;Park, Jeong Ho;Ko, Jang Myoun
    • ETRI Journal
    • /
    • v.38 no.2
    • /
    • pp.252-259
    • /
    • 2016
  • Di(1-aminopyrene)quinone (DAQ) as a quinone-containing conducting additive is synthesized from a solution reaction of 1-aminopyrene and hydroquinone. To utilize the conductive property of DAQ and its compatibility with activated carbon, a composite electrode for a supercapacitor is also prepared by blending activated carbon and DAQ (3:1 w/w), and its supercapacitive properties are characterized based on the cyclic voltammetry and galvanostatic charge/discharge. As a result, the composite electrode adopting DAQ exhibits superior electrochemical properties, such as a higher specific capacitance of up to $160F{\cdot}g^{-1}$ at $100mV{\cdot}s^{-1}$, an excellent high-rate capability of up to $1,000mV{\cdot}s^{-1}$, and a higher cycling stability with a capacitance retention ratio of 82% for the 1,000th cycle.

Hand Tracking and Calibration Algorithm Using the EPIC Sensors (EPIC 센서를 이용한 Hand Tracking 및 Calibration 알고리즘)

  • Jo, Jung Jae;Kim, Young Chul
    • Smart Media Journal
    • /
    • v.2 no.1
    • /
    • pp.27-30
    • /
    • 2013
  • In this paper, we research the hand tracking and calibration algorithm using the EPIC sensor. We analyze the characteristics of EPIC sensor to be more sensitive in the around E-filed, and then we implement the 2-dimensional axis-transformation using the difference of detected amplitude between EPIC sensors. In addition, we implement the calibration algorithm considering the characteristics of EPIC sensor, and then we apply the Kalman filter to efficiently track a target. Thus, we implement the environment of window applications for verification and analysis the implemented algorithm. In turn, we use the DAQ API to extract the analog data. The DAQ hardware has the function of measuring and generating an electrical signal. Moreover, we confirm the movement of mouse cursor by detecting the potential difference depending on the movement of the user's hands.

  • PDF

Feasibility Study of Data Acquisition System based on Oscilloscope for Radiation Detector (방사선 검출기용 데이터획득장치로서의 오실로스코프 활용 가능성 평가)

  • Yang, Jingyu;Kang, Jihoon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.12
    • /
    • pp.1804-1809
    • /
    • 2017
  • A data acquisition (DAQ) system based on oscilloscope was developed and evaluated for radiation detector. The dedicated LabVIEW program that perform the oscilloscope control and the data process was developed. Triggered events for each analog channel were acquired and the output signals were subsequently digitized and recorded for offline processing. Radiation pulse generation circuit was developed to evaluate the intrinsic characteristics of DAQ system. Energy linearity and energy resolution performances were assessed by voltage-peak channels and FWHM obtained from Gaussian fit, respectively. Radiation detector consists of LYSO and GAPD array. The 16 output signals were multiplexed by the RCD networks, and they were fed into the custom-made preamplifiers. Voltage-peak channels was linearly changed as a function of input voltage and the estimated coefficient of determination ($R^2$) was 0.999. No considerable changes in voltage resolution were observed. All 16 crystals were clearly identifiable on the resulting flood image and the mean energy resolution was ~15.1%. This study demonstrated that it is feasible to develop the DAQ system based on oscilloscope and LabVIEW program for radiation detector and the proposed approach offers opportunities to build simple DAQ system in various radiation measurement field.