• Title/Summary/Keyword: DAF(Dissolved Air Flotation)

Search Result 80, Processing Time 0.028 seconds

A pilot study of high flux membrane process for responding to influent turbidity changes in reservoir water (호소수 탁도변화 대응을 위한 고플럭스 막여과공정의 Pilot 연구)

  • Kang, Joonseok;Seong, Jayeong;Yoo, Jewan;Kim, Hyungsoo;Lee, Jaekyu;Jeon, Minhyuk;Cheon, Jihoon
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.34 no.6
    • /
    • pp.393-402
    • /
    • 2020
  • In the membrane process, it is important to improve water treatment efficiency to ensure water quality and minimize membrane fouling. In this study, a pilot study of membrane process using reservoir water was conducted for a long time to secure high flux operation technology capable of responding to influent turbidity changes. The raw water and DAF(Dissolved Air Flotation) treated water were used for influent water of membrane to analyze the effect of water quality on the TMP (Trans Membrane Pressure) and to optimize the membrane operation. When the membrane flux were operated at 70 LMH and 80 LMH under stable water quality conditions with an inlet turbidity of 10 NTU or less, the TMP increase rates were 0.28 and 0.24 kPa/d, respectively, with minor difference. When the membrane with high flux of 80 LMH was operated for a long time under inlet turbidity of 10 NTU or more, the TMP increase rate showed the maximum of 43.5 kPa/d. However, when the CEB(Chemically Enhanced Backwash) cycle was changed from 7 to 1 day, it was confirmed that the TMP increase rate was stable to 0.23 kPa/d. As a result of applying pre-treatment process(DAF) on unstability water quality conditions, it was confirmed that the TMP rise rates differed by 0.17 and 0.64 kPa/d according to the optimization of the coagulant injection. When combined with coagulation pretreatment, it was thought that the balance with the membrane process was more important than the emphasis on efficiency of the pretreatment process. It was considered that stable TMP can be maintained by optimizing the cleaning conditions when the stable or unstable water quality even in the high flux operation on membrane process.

Evaluation of microplastics reduction effects using Dissolved Air Floatation and Brown-gas (용존공기부상법과 브라운가스를 이용한 미세플라스틱 저감효과 평가)

  • Kim, Taekyoung;Jeong, Hanseok
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2022.05a
    • /
    • pp.474-474
    • /
    • 2022
  • 미세플라스틱이 물 환경으로 배출되는 주요 경로로는 하수처리장 방류수와 강우유출수가 있다. 하수처리장 및 유역에서 배출된 미세플라스틱은 하천과 하구역을 거쳐 해양과 같은 대규모 수역으로 이동하는데, 이 과정에서 해양뿐만 아니라 담수호, 저수지 등과 같은 공공수역에도 미세플라스틱이 지속적으로 축적되고 있다. 특히 강우유출수에 포함된 미세플라스틱은 적절한 처리 과정 없이 하천으로 유입되는 경우가 많아 공공수역 내 미세플라스틱 저감 기술의 필요성이 증가하고 있다. 그러나 미세플라스틱 관련 기존 연구는 미세플라스틱의 분포 등 현황에 대한 모니터링 및 환경위해성과 관련한 것이 대부분이며, 미세플라스틱 저감기술 관련 연구 또한 일부 정수처리 및 하수처리 공정을 대상으로 하는 초기 단계의 연구가 진행되고 있을 뿐 공공수역에서의 미세플라스틱 저감기술 개발 관련 연구는 전무한 실정이다. 따라서, 본 연구에서는 기존의 물리·화학적 수처리 공정인 용존공기부상법(Dissolved Air Flotation, DAF)에 물의 전기분해 시발생하는 브라운가스를 활용하여 응집된 물질을 빠르게 부상시켜 수체 내 오염물질을 제거할 수 있는 기술을 통해 수체 내 미세플라스틱 저감효과를 분석하였다. 또한, 해당 기술을 공공수역인 저수지에 적용하여 오염물질과 함께 미세플라스틱을 제거할 수 있는지 검토하였다.

  • PDF

Removal of heavy metals using waste sludge by biosorptive flotation (폐슬러지를 이용한 흡착·부상 공정에 의한 중금속 제거)

  • Lee Chang-Han;Ahn Kab-Hwan
    • Journal of Environmental Science International
    • /
    • v.14 no.7
    • /
    • pp.691-697
    • /
    • 2005
  • Waste sludge may be used to recovery wastewater contaminated with heavy metals. The waste sludge is an inexpensive readily available source of biomass for biosorption with metal-bearing wastewater. The biosorption of heavy metals such as Pb(II), Cu(II), Cr(II), and Cd(II) onto waste sludge was investigated in batch ex­periments and waste sludge loaded heavy metals was separated by dissolved air flotation. The biosorption equi­bria of heavy metals could be described by Langmuir and Freundich isotherms. The adsorption capacity for waste sludge was in the sequence of Pb(II)>Cr(II)>Cu(II)>Cd(II). The system attained equilibrium about 20 min. The Langmuir and Freundlich adsorption model effectively described the biosorption equilibrium of Cu(II) and Cr(II) ions on waste sludge. Maximum adsorption capacity of Cu(II) and Cr(II) were 196.08 and 158.73 mg/g, respectively. Solid-liquid separation efficiencies were kept above $95\%$ on waste sludge loaded heavy metals, and were decreased with pH increasing.

Application of Dissolved Air Flotation Technique to Improve Eutrophic Reservoir Water Quality (가압부상법을 이용한 부영양저수지의 수질개선)

  • Kim, Ho-Sub;Jung, Dong-Il;Lee, Il-Kuk;Hwang, Soon-Jin
    • Korean Journal of Ecology and Environment
    • /
    • v.38 no.3 s.113
    • /
    • pp.372-381
    • /
    • 2005
  • This study was conducted to test the efficiency of water quality improvement using the dissolved air flotation (DAF) technique in a shallow eutrophic reservoir. The application of DAF was followed by the addition of a chemical coagulant (poly aluminum chloride; PAC). The experiment was conducted in the mesocosm scale (wide ${\times}$ length ${\times}$ depth: 6 m ${\times}$ 6 m ${\times}$ 3 m). Suspended solids (SS) and volatile SS (VSS) concentration decreased by 54 ${\sim}$ 71% and 57 ${\sim}$ 79% of the initial concentrations, respectively. Total phosphorus and Chl- a concentration also decreased by 74 ${\sim}$ 92% and 54 ${\sim}$ 98%, respectively. BOD decreased by>86% while COD decrease ranged 29 ${\sim}$ 63%. Dissolved inorganic P (DIP) and dissolved total P (DTP) concentration decreased by 34 ${\sim}$ 88% and 62 ${\sim}$ 88%, respectively. After DAF application further onto the sediment, DIP-release rates from the sediment decreased by 17% (0.82 ${\to}$ 0.68 mg $m^{-2}$$day^{-1}$ in the oxic condition and 23% (2.27 ${\to}$ 1.76 mg $m^{-2}$$day^{-1}$) in the anoxic condition, compared to the release rate from the untreated sediment. DTP-release rate from both the oxic and anoxic sediments also decreased by 33% (5.62 ${\to}$ 3.78 mg $m^{-2}$$day^{-1}$) and 20% (6.23 ${\to}$ 4.99 mg $m^{-2}$$day^{-1}$), respectively. These results suggest that the DAF application both to the water column and onto the sediment be effective to improve water quality by removing particulate matters in the water column as well as reducing P-release from the sediment.

Wastewater Treatment Process Study for Used Diaper Recycling (사용 후 기저귀 재활용을 위한 폐수처리방안 연구)

  • Kim, Kyung Shin;Lee, Ho Sun
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.47 no.2
    • /
    • pp.24-33
    • /
    • 2015
  • This study aims to suggest wastewater treatment options for diaper recycling by identifying characteristic analysis of wastewater from diaper recycling process and efficiency evaluation of wastewater treatment units. The wastewater characteristic analysis showed that the concentration of organic pollutants and ionic materials were very high comparing to seawater. Through the investigation of similar wastewater treatment, six treatment units were identified to reduce pollutants. It is found UF(ultra-filtration), DAF(dissolved air flotation), fenton oxidation, electro-coagulation and chemical-coagulation are effective in reducing organic pollutants while membrane system and ion exchanger are effective in reducing ionic materials. Even though the target of water quality should be secured in terms of managing organic pollutants level, the application of treatment unit for reducing ionic material needs lots of considerations. This result suggests that reuse of pulping wastewater after controlling organic pollutants is better than direct discharge of pulping wastewater. To select the appropriate wastewater treatment unit, an economic analysis about operation condition, wastewater flow, cost, efficiency should be considered.

Wastewater Reuse in Textile Industry: Case of Bandung, Indonesia (섬유공장폐수 재이용 사례: 인도네시아 반둥을 대상으로)

  • Chung, Youngkun;Lee, Mi-Young;Yang, Shi Chun;Kang, Seoktae
    • Journal of Appropriate Technology
    • /
    • v.5 no.1
    • /
    • pp.18-24
    • /
    • 2019
  • Citarum river in West Java, Indonesia plays strategic roles for Jakarta metropolitan areas. Besides it provides major source of water supply such as domestics and drinking water including Jakarta, it also provides water for hundreds of industries through its cascade reservoirs. However, recently, Citarum river basin has been seriously suffering from water and groundwater pollution as well as the lowering-down of groundwater level due to the extreme use of water resources in dry season by domestic and industrial activities. This project objectives are design and installation of industrial wastewater treatment/recycle facilities to overcome the problem of water pollution and the lowering-down of groundwater level in Bandung. For these, cyclone type dissolved air flotation (DAF), CYFLOAT, was successfully installed as the appropriate technology for the target textile industry with 100 ton/day of capacity. The CYFLOAT system can remove the 96.8% of particulates, which are known as a critical factor to recycle the wastewater, within 40 min of residence time. Furthermore, The CYFLOAT system can reduce the operational cost and land use. The project was carried out in strong partnership with local institute including UNPAR, IBT, and PUSKIM for the sustainability of the technology to textile industry complex in Indonesia.

A Study on the Shape and Movement in Dissolved Air Flotation for the Algae Removal (수중조류제거(水中藻類除去)를 위한 가압부상(加壓浮上)에 있어서 기포(氣泡)의 양태(模態)에 관한 연구(研究))

  • Kim, Hwan Gi;Jeong, Tae Seop
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.4 no.4
    • /
    • pp.79-93
    • /
    • 1984
  • The dissolved air flotation(DAF) has been shown to be efficient process for the removal of algae ftom water. The efficiency of DAF can be affected by the volume ratio of pressurized liquid to sample, the pressure pressurized liquid, the contact time, the appropriate coagulant and its amount, the water temperature, the turbulence of reactor, the bubble size and rising velocity etc. The purpose of this paper is to compare the practical bubble rising velocity with the theoretical one, to investigate the adhesion phenomenon of bubbles and floc, and the influence of bubble size and velocity upon the process. The results through theoretical review and experimental investigation are as follows: Ives' equation is more suitable than Stokes' equation in computation of the bubble rising velocity. The collection of bubble and algae floc is convective collection type and resulted from absorption than adhesion or collision. The treatment efficiency is excellent when the bubble sizes are smaller than $l00{\mu}m$, and the turbulence of reactor is small. In the optimum condition of continuous type DAF the volume ratio of pressurized liquid to sample is 15%, the contact time in reactor is 15 minutes, the pressure of pressurized liquid is $4kg/cm^2$ and the distance from jet needle to inlet is 30cm.

  • PDF

Management Measures for the Control of Agricultural Reservoirs in Han River Watershed (한강수계 농업용저수지 관리방안)

  • Kim, Ho-Sub;Kong, Dong-Soo;Jung, Dong-Il;Hwang, Soon-Jin
    • Journal of Korean Society on Water Environment
    • /
    • v.25 no.3
    • /
    • pp.386-393
    • /
    • 2009
  • This study was carried out to assess water quality and to introduce the management measures for water quality improvement with the collected data from 87 agricultural reservoirs in Han river watershed. According to the water quality criteria (WQC) for lake based on the COD, TP, TN and chl.a concentration, 18, 16, 4 and 19 of 87 reservoirs exceed class IV, respectively. Based on the trophic state index (TSI) with chl.a concentration, 51 of selected reservoirs appeared to be eutrophic. Phosphorus was limiting nutrient on algal growth in 58 reservoirs. TP, chl.a and COD concentration in 23 of 49 agricultural reservoirs with chl.a concentration ${\geq}25{\mu}g/L$ and eutrophic exceed class IV by WQC. Also, the mean depth in 21 of 23 reservoirs was below 5m. Our results suggest that advanced wastewater treatment and crop land control in watershed of reservoirs with TP concentration ${\geq}0.1mg/L$ would be a effective tool to improve water quality. Dredging would to be effective measure in reservoirs with mean depth < 5 m and relatively old age. In reservoirs with chl.a concentration ${\geq}50{\mu}g/L$, application of technique such dissolved air flotation (DAF) and P inactivation be effective to improve water quality by removing particulate matters in water column. The management measure to control inflow such as sedimentation basin, Pre-dam and diversion would to be application in reservoirs with shallow depth, while large watershed and surface area.

A Practical Study on the Solid-Liquid Separation of the Swine Wastewater from Slurry Feedlot (슬러리 양돈분뇨의 최적 고액분리 방안 연구)

  • Park, Seung-Kyun;Choi, Jae-Gil;Chung, Yoon-Jin
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.8 no.2
    • /
    • pp.60-70
    • /
    • 2000
  • The swine wastewater from slurry feedlot has been a social problem in Korea since the proper treatment is very difficult. Therefore, a practical study on the Solid-Liquid separation of swine wastewater from slurry feedlot was carried out as a pan of pretreatment for the successful biological treatment. The appropriate type of coagulant and optimum dosage were proposed for the most efficient Solid-Liquid separation and the best Solid-Liquid separation methods for different size of feedlot were determined through the tests with field-scaled Solid-Liquid separation equipment. The appropriate coagulant for the conditioning of dewatering property was E-851, which is a cationic polyelectrolyte made of polyacrylamide, and the optimum dosage was 0.24~0.6% of unit solids weight. Mesh Screen, Drum Screen, Cyclone Drum Filter, Screw Press, High-speed Screw Decanter, Low-speed Screw Decanter, and Dissolved Air Flotation Process had been investigated in this study. According to the results, the Screw Press was the best dewatering equipment for the small & medium size for feedlot and low-speed Screw Decanter was the best for the large size feedlot & public owned treatment facilities for the primary Solid-Liquid separation, and the most suitable secondary treatment process was DAF. On the other hand, reductions for the requirement of bulking agent and organic loading by Solid-Liquid separation process were 94.8% and 84.7%, respectively Therefore, the Solid-Liquid separation process must be required for the successful treatment of swine wastewater from slurry feedlot.

  • PDF

Remediation of Sediments using Micro-bubble (미세기포를 이용한 퇴적물 정화)

  • Kang, Sang Yul;Kim, Hyoung Jun;Kim, Tschung Il;Park, Hyun Ju;Na, Choon Ki;Han, Moo Young
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.38 no.8
    • /
    • pp.420-427
    • /
    • 2016
  • This study was conducted on the sediment remediation using micro-bubble to remove fine particles. For this study, characteristics of contamination and release in sediment were analyzed. And then, the characteristics of bubbles on removal efficiency was investigated at various operation conditions. In particle size distribution of the sediment used for the study, the proportion of clay and silt (<0.075 mm) was about 7.7%, sand (0.075~4.75 mm) was about 67.8%, and gravel (${\geq}4.75$) was 24.5%. Total nitrogen (TN) and total phosphorus (TP) of the sediment were 2,790~3,260, 261~311 mg/kg respectively. Ignition loss and water content were 4.1~9.6, 32.9~53.2% respectively. In analysis of removal efficiency according to operation conditions of micro-bubble, it was the highest when operation condition is pressure 6 atm, pressurized water ratio 30%, and coagulant dosage 15 ppm. At the time, the sediment's removal efficiency was 19.9%. Accordingly removal efficiency of TN and TP were 21.4, 22.6% respectively. Finally a research was found that fine particles in sediment were almost removed by micro-bubble, which led to decrease nutrients' release at about 20.1~64.3% in comparison to sediment including lots of fine particles.