• Title/Summary/Keyword: D43

Search Result 3,576, Processing Time 0.034 seconds

Three-Dimensional Surface Imaging is an Effective Tool for Measuring Breast Volume: A Validation Study

  • Lee, Woo Yeon;Kim, Min Jung;Lew, Dae Hyun;Song, Seung Yong;Lee, Dong Won
    • Archives of Plastic Surgery
    • /
    • v.43 no.5
    • /
    • pp.430-437
    • /
    • 2016
  • Background Accurate breast volume assessment is a prerequisite to preoperative planning, as well as intraoperative decision making in breast reconstruction surgery. The use of three-dimensional surface imaging (3D scanning) to assess breast volume has many advantages. However, before employing 3D scanning in the field, the tool's validity should be demonstrated. The purpose of this study was to confirm the validity of 3D-scanning technology for evaluating breast volume. Methods We reviewed the charts of 25 patients who underwent breast reconstruction surgery immediately after total mastectomy. Breast volumes using the Axis Three 3D scanner, water-displacement technique, and magnetic resonance imaging (MRI) were obtained bilaterally in the preoperative period. During the operation, the tissue removed during total mastectomy was weighed and the specimen volume was calculated from the weight. Then, we compared the volume obtained from 3D scanning with those obtained using the water-displacement technique, MRI, and the calculated volume of the tissue removed. Results The intraclass correlation coefficient (ICC) of breast volumes obtained from 3D scanning, as compared to the volumes obtained using the water-displacement technique and specimen weight, demonstrated excellent reliability. The ICC of breast volumes obtained using 3D scanning, as compared to those obtained by MRI, demonstrated substantial reliability. Passing-Bablok regression showed agreement between 3D scanning and the water-displacement technique, and showed a linear association of 3D scanning with MRI and specimen volume, respectively. Conclusions When compared with the classical water-displacement technique and MRI-based volumetry, 3D scanning showed significant reliability and a linear association with the other two methods.

Design of Local Oscillator with Low Phase Noise for Ka-band Satellite Transponder (Ka-band 위성 중계기용 저위상잡음 국부발진기의 설계 및 제작)

  • 류근관;이문규;염인복;이성팔
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.13 no.6
    • /
    • pp.552-559
    • /
    • 2002
  • The EM(Engineering Model) LO(Local Oscillator) is designed for Ka-band satellite transponder. The VCO(Voltage Controlled Oscillator) is implemented using a high impedance inverter coupled with dielectric resonator to improve the phase noise performance out of the loop bandwidth. The phase of VCO is locked to that of a stable OCXO(Oven Controlled Crystal Oscillator) by using a SPD(Sampling Phase detector) to improve phase noise performance in the loop bandwidth. This LO exhibits the harmonic rejection characteristics above 43.83 dBc and requires 15 V and 160 mA. The phase noise characteristics are performed as -102.5 dBc/Hz at 10 KHz offset frequency and -104.0 dBc/Hz at 100 KHz offset frequency, respectively, with the output power of 13.50 dBm$\pm$0.33 dB over the temperature range of -20~+7$0^{\circ}C$.

A Study on a Method to Use Industrial and Technical Information in Process of R&D Project Planning (연구개발(R&D)과제 기획에서의 산업·기술정보 활용방안)

  • Kim, Yong;Han, Hee-Jung;Lee, Kyun-Hyung;Lee, Yoon-Seok;An, Seung-Kwon
    • Journal of Information Management
    • /
    • v.43 no.4
    • /
    • pp.69-96
    • /
    • 2012
  • Based on analysis of trend and development of industrial and technical information such as patents and scientific data, using industrial and technical information in the process of planning can be a important factor to reduce budget and opportunity cost. This study aims to investigate needs to collect and analyze industrial and technical information in planning of R&D project. To do it, this study examines definitions, needs and types of industrial and technical information for planning of R&D project. And then this study investigates the importance of use of industrial and technical information in the process of planning of R&D and performs case study in domestic and foreign countries. Lastly, this study investigates a method to analyze industrial and technical information for R&D planning and proposes the role of a library for R&D planning.

Saccharomyces yeast postbiotics supplemented in feeds for sows and growing pigs for its impact on growth performance of offspring and growing pigs in commercial farm environments

  • Sung Woo Kim;Marcos Elias Duarte
    • Animal Bioscience
    • /
    • v.37 no.8
    • /
    • pp.1463-1473
    • /
    • 2024
  • Objective: Three experiments were conducted to evaluate the effects of Saccharomyces yeast postbiotics (SYP) in feeds for sows on the growth of offspring (Exp. 1), for nursery pigs on their growth (Exp. 2), and for nursery and finishing pigs on their growth (Exp. 3). Methods: Exp. 1 had 80 sows at breeding assigned to 4 groups with SYP at 0, 0.050, 0.175, and 0.500 g/kg. Offspring were fed a common diet for 126 d. Exp. 2 had 144 barrows at 8 kg body weight (BW) allotted to CON (no SYP); YPC (SYP at 0.175 g/kg; d 0 to 42); and YPD (SYP at 1.25, 0.75, and 0 g/kg; d 0 to 7, d 8 to 21, and d 22 to 42, respectively) with 8 pens/treatment (6 pigs/pen). Exp. 3 had 96 barrows at 8 kg BW allotted to CON (no SYP); YPN (SYP at 0.175 g/kg; d 0 to 42); YPF (SYP at 0.100 g/kg; d 43 to 119); and YPA (SYP at 0.175 and 0.100 g/kg; d 0 to 42 and d 43 to 119, respectively) with 8 pens/treatment (3 pigs/pen). Results: In Exp. 1, increasing SYP increased (p<0.05, quadratic) the sow body score (maximum at 0.30% SYP), reduced (p<0.05, quadratic) the days-wean-to-estrus (minimum at 0.27% SYP), and increased (p<0.05) offspring BW at weaning and their average daily gain (ADG) and feed efficiency (G:F) at d 126. In Exp. 2, ADG, average daily feed intake (ADFI), and G:F of YPC were the greatest (p<0.05). The ADG and ADFI of YPD were greater (p<0.05) than CON. Fecal score of YPC and YPD was smaller (p<0.05) than CON. In Exp. 3, YPA had the greatest (p<0.05) ADG and YPN and YPF had greater (p<0.05) ADG than CON. Conclusion: SYP enhanced sow performance, offspring growth, growth of nursery and growing pigs with the greater efficacy at 0.27 to 0.32 g/kg feed.

VC-DIMENSION AND DISTANCE CHAINS IN 𝔽dq

  • ;Ruben Ascoli;Livia Betti;Justin Cheigh;Alex Iosevich;Ryan Jeong;Xuyan Liu;Brian McDonald;Wyatt Milgrim;Steven J. Miller;Francisco Romero Acosta;Santiago Velazquez Iannuzzelli
    • Korean Journal of Mathematics
    • /
    • v.32 no.1
    • /
    • pp.43-57
    • /
    • 2024
  • Given a domain X and a collection H of functions h : X → {0, 1}, the Vapnik-Chervonenkis (VC) dimension of H measures its complexity in an appropriate sense. In particular, the fundamental theorem of statistical learning says that a hypothesis class with finite VC-dimension is PAC learnable. Recent work by Fitzpatrick, Wyman, the fourth and seventh named authors studied the VC-dimension of a natural family of functions ℋ'2t(E) : 𝔽2q → {0, 1}, corresponding to indicator functions of circles centered at points in a subset E ⊆ 𝔽2q. They showed that when |E| is large enough, the VC-dimension of ℋ'2t(E) is the same as in the case that E = 𝔽2q. We study a related hypothesis class, ℋdt(E), corresponding to intersections of spheres in 𝔽dq, and ask how large E ⊆ 𝔽dq needs to be to ensure the maximum possible VC-dimension. We resolve this problem in all dimensions, proving that whenever |E| ≥ Cdqd-1/(d-1) for d ≥ 3, the VC-dimension of ℋdt(E) is as large as possible. We get a slightly stronger result if d = 3: this result holds as long as |E| ≥ C3q7/3. Furthermore, when d = 2 the result holds when |E| ≥ C2q7/4.

초다시점(SMV) 3D 디스플레이의 소개

  • Kim, Seong-Gyu
    • Information and Communications Magazine
    • /
    • v.31 no.2
    • /
    • pp.37-43
    • /
    • 2014
  • 현재 3D 디스플레이는 입체 영화의 흥행 성공으로 안경식 3DTV 및 3D 모니터 등으로 국내 디스플레이 대기업들이 세계적으로 선도하는 상황에 있다. 그러나 안경 착용의 불편함 그리고 눈의 피로현상 등의 문제로 진정한 3D 디스플레이의 대중적 상용화를 위한 기술 발전이 더 필요한 상황이다. 본 고에서는 이러한 핵심 문제점들을 최소화할 가능성을 갖는 초다시점 기술에 대하여 그 기술의 개념 및 발전과 현재 상황 그리고 핵심연구 주제 등에 대하여 기술한다.

The Excavating Performance of Jet Steram for the Ground (분사류의 저질에 대한 굴삭성능에 관한 연구)

  • KIM Cheol-Ho;KO Kwan-Soh
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.22 no.4
    • /
    • pp.201-213
    • /
    • 1989
  • This study is just to be carried out to grasp the efficiency of jet stream excavating for the ground. Changing the dynamic pressure, nozzle diameter, distance off the ground, we measured the impulse, the excavated depth, the excavated width. According as each dynamic pressure increases from 100 to $500gf/cm^2$, the impulse of the jet stream increases from 43 to 114gf, from 52 to 227gf, from 114 to 506gf, from 137 to 768gf, in 4, 6, 8, 10mm nozzles respectively, but it makes no difference in the value of distance within 50cm off ground. The excavated depth increases at the invariable rate in accordance with nozzle diameter, dynamic pressure, nozzle distance. We obtain the equations relevant to the ground I, II as follows: $$L_I=[0.01(H/r-100) -0.43\cdot\iota+11.78]{\cdot}D/4$$ $$L_{II}=[0.03(H/r-100) -0.34\cdot\iota+6.39]{\cdot}D/4$$ where, $L_I,\;L_{II}$ are respectively the excavated depths of the ground I, II, cm; H is the dynamic pressure, $gf/cm^2\;:\;\iota$ is the distance off the ground, cm; D is Nozzle diameter, mm; r is the specific weight, $1gf/cm^2$.

  • PDF

A Study on the Thyroid Dose High-Energy Radiation Therapy of Lung Cancer (폐암 고에너지 방사선치료 시 갑상선 피폭에 관한 연구)

  • Yang, Oh-Nam;Lim, Cheong-Hwan
    • The Journal of the Korea Contents Association
    • /
    • v.15 no.6
    • /
    • pp.297-302
    • /
    • 2015
  • High-energy medical linear accelerator on the dose to the thyroid cancer during radiotherapy were evaluated using optical stimulation luminescence dosimeters(OSLD) using. Scattered's influence in the case of 3D-CRT 25.4 mSv, 28.8 mSv, 31.3 mSv, 26.5 mSv, 27.4 mSv 5 times with an average 27.9 mSv, in the IMRT 46.8 mSv, 43.2 mSv, 42.3 mSv, 41.5 mSv, 44.1 mSv to five times the average of 43.6 was the result of mSv. In the case of light neutron dosimetry results 3D-CRT 3 mSv, 3 mSv, 3.4 mSv, 3.5 mSv, 3.1 mSv to five times the average 3.2 mSv, in the IMRT 5.1 mSv, 4.8 mSv, 4.2 mSv, 4.8 mSv, 4.9 mSv, to five times the average of 4.7 was the result of mSv. Both parties and the light scattered neutrons were significantly appreciated compared to IMRT 3D-CRT. Treatment of cancer using radiation workers, as in this study, and that a significant amount of scattered rays in the adjacent normal tissues during radiation therapy using energy assessment to influence by fully aware of this information is necessary for the exposure reduction efforts the feed.