• Title/Summary/Keyword: D2D Coverage

Search Result 237, Processing Time 0.023 seconds

Effect of Soft Handoff Technique on CDMA Cell Coverage in a Lognormally Shadowed Channel (전파음영 채널 환경에서 소프트 핸드오프 기법이 CDMA 셀룰러 시스템의 셀 커버리지에 미치는 영향)

  • Oh, Hyon-Kyu;Kim, Hang-Rae;Kim, Nam
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.12 no.6
    • /
    • pp.871-881
    • /
    • 2001
  • In this paper, the effect of soft handoff technique on CDMA cell coverage is analyzed in a lognormally shadowed channel, which uses the Hata propagation model, Also, the rate of increase for the cell coverage is analyzed by calculating the hard and soft handoff margin. When the outage probability is 0.02 and the standard deviation of the received signal is 2.5 dB in a lognormally shadowed channel, the transmit power of the mobile station which is located in the cell boundary is increased by the hard handoff margin of 5.13 dB and by the soft handoff margin of 3.68 dB, respectively. So, the rate of increase for the cell coverage is 1.39 in case of using the soft handoff technique. It is shown that if the (E$\_$b//N$\_$0/)$\_$req/ value is 7 dB, the cell coverage of the CDMA cellular system with soft handoff technique in city area is 3.33 km in case of the 850 MHz frequency and 1.36 km in case of the 1900 MHz frequency. Also, the accurate cell coverage with soft handoff technique is supported that could be serviced by the base-station in CDMA cellular system.

  • PDF

Comparison of 2-Dimensional and 3-Dimensional Conformal Treatment Plans in Gastric Cancer Radiotherapy

  • Adas, Yasemin Guzle;Andrieu, Meltem Nalca;Hicsonmez, Ayse;Atakul, Tugba;Dirican, Bahar;Aktas, Caner;Yilmaz, Sercan;Akyurek, Serap;Gokce, Saban Cakir;Ergocen, Salih
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.17
    • /
    • pp.7401-7405
    • /
    • 2014
  • Background: Postoperative chemoradiotherapy is accepted as standard treatment for stage IB-IV, M0 gastric cancer. Radiotherapy (RT) planning of gastric cancer is important because of the low radiation tolerance of surrounding critical organs. The purpose of this study was to compare the dosimetric aspects of 2-dimensional (2D) and 3-dimensional (3D) treatment plans, with the twin aims of evaluating the adequacy of 2D planning fields on coverage of planning target volume (PTV) and 3D conformal plans for both covering PTV and reducing the normal tissue doses. Materials and Methods: Thirty-six patients with stage II-IV gastric adenocarcinoma were treated with adjuvant chemoradiotherapy using 3DRT. For each patient, a second 2D treatment plan was generated. The two techniques were compared for target volume coverage and dose to normal tissues using dose volume histogram (DVH) analysis. Results: 3DRT provides more adequate coverage of the target volume. Comparative DVHs for the left kidney and spinal cord demonstrate lower radiation doses with the 3D technique. Conclusions: 3DRT produced better dose distributions and reduced radiation doses to left kidney and spinal cord compared to the 2D technique. For this reason it can be predicted that 3DRT will result in better tumor control and less normal tissue complications.

Erlang Capacity and Cell Coverage Based on Handoff Techniques in the Reverse Link of a CDMA System of 14.4 kbps/1.9 GHz Band (1.9 GHz 대역/14.4 kbps CDMA 시스템의 역방향 링크에서 핸드오프 유형별 얼랑용량과 셀커버리지)

  • Kwon, Young-Soo;Kim, Nam
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.28 no.1A
    • /
    • pp.25-33
    • /
    • 2003
  • We derive the outage probabilities for the Erlang capacity and link margin based on handoffs in the reverse link of a CDMA system of 14.4 kbps/1.9 GHz band, calculate them with the same parameters, and then with the maximum realizable Erlang capacity analyze newly the cell coverage in different areas by the COST-231 model If it decreases from 5 % to 2 % in case of $E_b/N_0$=5 dB under a soft handoff, the result shows a very reliable link with additional increment of 0.88 dB in the margin and a high quality of service within the coverage decrease of 0.12 km, 0.25 km, and 1 km in a city, suburban, and open areas respectively on the decrease of 2 Erlang in the capacity. When the $E_b/N_0$ decreases from 7 dB to 5 dB within the outage probability of 5 %, it shows the increase of 9 Erlang and of 0.2 km in a city on the same margin of 2.8 dB. Then, comparing it with a single cell, it shows the decrease of more than 10 Erlang in the capacity, but the enlargement of 0.17 km, 0.3 km, and 1 km in them on the margin decrease of 1.31 dB, also, with a hard handoff, the soft handoff gain of the increase of 10 Erlang and of 0.22 km, 0.5 km, and 2 km on the decrease of 2.16 dB.

3D Seismic Travel-time Tomography using Fresnel Volume (프레넬 볼륨을 이용한 3차원 탄성파 주시 토모그래피)

  • Ko, Kwang-Beom;Lee, Doo-Sung
    • Geophysics and Geophysical Exploration
    • /
    • v.6 no.2
    • /
    • pp.101-107
    • /
    • 2003
  • 3D seismic travel-time tomography algorithm baled on Fresnel volume was developed and its feasibility was investigated by the numerical experiments. To testify the field applicability of the developed algorithm, frequency characteristics and way coverage of the crossholel seismic raw data were investigated and 3D velocity tomogram cube with about 8m spatial resolution was obtained. When compared this 3D velocity cube with the conventional 2D ray tomogram, two results were matched well. We concluded that 3D seismic tomography algorithm developed in this study has enough potential to the field application.

Small ESPAR Antenna with 180 Degree Azimuth Beam Coverage (180도 방위 빔 커버리지 특성을 갖는 UNII대역 소형 전자 빔 조향 기생 배열 안테나)

  • Choi, Ik-Guen;Ju, Sang-Ho
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.15 no.2
    • /
    • pp.11-16
    • /
    • 2010
  • In this papar, we have proposed a small electronically steerable parasitic array radiator with 180 degree azimuth beam coverage and high gain characteristics. The proposed antenna is composed of a uniplanar Yagi dipole as a feeding element and two dipoles as parasitic elements. The fabricated antenna is tested by electronically changing the reactance loaded on the parasitic dipoles and the results show that it has 5.2dB~6.7dB gain in $-90^{\circ}{\sim}90^{\circ}$wide azimuth range and -10dB return loss characteristics within 5.725GHz~5.825GHz UNII band.

The Effect of Left Subclavian Artery Coverage During Endovascular Repair of the Thoracic Aortic Aneurysm on Cerebral Hemodynamics: Two Cases of Flow Measurement by using 2D Phase Contrast Magnetic Resonance Imaging (흉부대동맥류의 혈관내치료 도중 좌측 쇄골하동맥 폐색이 뇌혈류역동에 미치는 효과: 2차원 위상차 대조 자기공명영상을 이용한 혈류 측정 2례 보고)

  • Baek, Seung-Hoon;Youn, Sung-Won;Kim, Ho-Kyun;Kwon, Oh-Choon;Lee, Sub;Lee, Jong-Min
    • Investigative Magnetic Resonance Imaging
    • /
    • v.16 no.2
    • /
    • pp.159-168
    • /
    • 2012
  • The proximity of thoracic aortic aneurysm to the left subclavian artery (LSA) has made the coverage of LSA during thoracic endovascular aortic repair (TEVAR) be essential. Despite controversy concerning the safety of LSA coverage and the indications for LSA revascularizations, the cerebral hemodynamic change after LSA coverage has not been demonstrated. We prospectively examined two patients who would undergo TEVAR with LSA coverage by using 2D cine phase contrast MR imaging. After LSA coverage, the left subclavian steal was properly compensated by the increased flow volumes of both carotid arteries and right vertebral artery, which is the major collateral supply. The total brain supply after TEVAR did not lessen, which showed good correlation with uneventful clinical outcome. Therefore, 2D phase contrast MR imaging can be recommended as a useful technique to evaluate the hemodynamic change of the LSA coverage during TEVAR and to triage the candidate for LSA revascularization.

The solid angle estimation of acetabular coverage of the femoral head (입체각을 이용한 관골구와 대퇴골두의 접촉영역 측정)

  • 최교환;임제택;김선일
    • Journal of the Korean Institute of Telematics and Electronics S
    • /
    • v.35S no.2
    • /
    • pp.79-88
    • /
    • 1998
  • We developed a method for the solid angle estimation of acetabular coverage of the femoral head in 3D space. The superior half of the femoral head is modeled as part of a sphere. And the tangent lines connecting from a set of points of the acetabular outline to the center of the fitted sphere are obtained. The lines passthrough the unit sphere whose center is the same as that of the femoral head. The interesecting points form a boundary on the unit sphere. With the points on the unit sphere, we calculate the covered area of the femoral headand estimate the solid angle. Solid angle is defined asthe suface area within the boundary on the unit sphere. In this measurements, the solid angle of normal subjects is on an average 4.3(rad) and the corresponding acetabular coverage is 68%. Unlinke the conventional methods, this solid angle estimation shows real 3D acetabular coverage.

  • PDF

Dosimetric Comparison between Intensity Modulated Radiotherapy and 3 Dimensional Conformal Radiotherapy in the Treatment of Rectal Cancer

  • Simson, David K;Mitra, Swarupa;Ahlawat, Parveen;Sharma, Manoj Kumar;Yadav, Girigesh;Mishra, Manindra Bhushan
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.11
    • /
    • pp.4935-4937
    • /
    • 2016
  • Objective: To compare dosimetric parameters of 3 dimensional conformal radiotherapy (3 DCRT) and intensity modulated radiotherapy (IMRT) in terms of target coverage and doses to organs at risk (OAR) in the management of rectal carcinoma. Methods: In this prospective study, conducted between August 2014 and March 2016, all patients underwent CT simulation along with a bladder protocol and target contouring according to the Radiation Therapy Oncology Group (RTOG) guidelines. Two plans were made for each patient (3 DCRT and IMRT) for comparison of target coverage and OAR. Result: A total of 43 patients were recruited into this study. While there were no significant differences in mean Planning Target Volume (PTV) D95% and mean PTV D98% between 3 DCRT and IMRT, mean PTV D2% and mean PTV D50% were significantly higher in 3 DCRT plans. Compared to IMRT, 3 DCRT resulted in significantly higher volumes of hot spots, lower volumes of cold spots, and higher doses to the entire OAR. Conclusion: This study demonstrated that IMRT achieves superior normal tissue avoidance (bladder and bowel) compared to 3 DCRT, with comparable target dose coverage.

MRI Image Super Resolution through Filter Learning Based on Surrounding Gradient Information in 3D Space (3D 공간상에서의 주변 기울기 정보를 기반에 둔 필터 학습을 통한 MRI 영상 초해상화)

  • Park, Seongsu;Kim, Yunsoo;Gahm, Jin Kyu
    • Journal of Korea Multimedia Society
    • /
    • v.24 no.2
    • /
    • pp.178-185
    • /
    • 2021
  • Three-dimensional high-resolution magnetic resonance imaging (MRI) provides fine-level anatomical information for disease diagnosis. However, there is a limitation in obtaining high resolution due to the long scan time for wide spatial coverage. Therefore, in order to obtain a clear high-resolution(HR) image in a wide spatial coverage, a super-resolution technology that converts a low-resolution(LR) MRI image into a high-resolution is required. In this paper, we propose a super-resolution technique through filter learning based on information on the surrounding gradient information in 3D space from 3D MRI images. In the learning step, the gradient features of each voxel are computed through eigen-decomposition from 3D patch. Based on these features, we get the learned filters that minimize the difference of intensity between pairs of LR and HR images for similar features. In test step, the gradient feature of the patch is obtained for each voxel, and the filter is applied by selecting a filter corresponding to the feature closest to it. As a result of learning 100 T1 brain MRI images of HCP which is publicly opened, we showed that the performance improved by up to about 11% compared to the traditional interpolation method.

A Study on Test Coverage for Software Reliability Evaluation (소프트웨어 신뢰도 평가를 위한 테스트 적용범위에 대한 연구)

  • Park, Jung-Yang;Park, Jae-Heung;Park, Su-Jin
    • The KIPS Transactions:PartD
    • /
    • v.8D no.4
    • /
    • pp.409-420
    • /
    • 2001
  • Recently a new approach to evaluation of software reliability, one of important attributes of a software system, during testing has been devised. This approach utilizes test coverage information. The coverage-based software reliability growth models recently appeared in the literature are first reviewed and classified into two classes. Inherent problems of each of the two classes are then discussed and their validity is empirically investigated. In addition, a new mean value function in coverage and a heuristic procedure for selecting the best coverage are proposed.

  • PDF