• Title/Summary/Keyword: D128G

Search Result 117, Processing Time 0.026 seconds

A Study on Current Waveform Control and Performance Improvement for Inverter Arc Welding Machine (인버터 아크 용접기의 파형제어기법 및 성능향상에 관한 연구)

  • 채영민;고재석;김진욱;이승요;최해룡;최규하
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.4 no.2
    • /
    • pp.128-137
    • /
    • 1999
  • Recently the pelionnance of CO2 arc welding machine has been advanced significantly through the adoption of i invelter circuit topology. which made it possible to improve welding perfonnances such as spatter generation and bead s state. But the conventional inverter arc welding machine generates constant output voltage which cause much spatter g generation dUling short-circuit and arc start time because it is unable to control output current instantaneously. So this p paper representes wavefCnm controlled inverter arc welding machine which control the wavefonn of welding current and t thus to suppress the spatter generation. And the system designed in this paper is the digital controller using single chip m microprocessor of 80C196KC. As a result of perfonnance test for this system, the spatter generation is reduced and s shOlt-circuit time period is stabilized compared to conventional one. And more by using switched mode rectifier for A AC/DC power convelter. unity power factor is maintained and low order halmonic spectrum is supressed.

  • PDF

Dehydration of foamed sardine-starch paste by microwave heating. (고주파가열을 이용한 정어리 발포건조제품의 가공 II. 제품저장중의 품질변화와 저장기간)

  • 이병호
    • Journal of the Korean Professional Engineers Association
    • /
    • v.17 no.4
    • /
    • pp.8-14
    • /
    • 1984
  • In this part of the studies on dielectric dehydration of foamed fish-starch paste, quality stability and shelflife of the product of which the preparation formula and processing conditions were described in the previous report (Lee et at., 1982) were determined by means of accelerated reaction test. The product was stored for 50 days under the conditions of temperatures at 35, 45, and 55$^{\circ}C$ in steady state and various water activities of 0.44, 0.52, 0.65, and 0.75, respectively. The loss of available lysine, the extent of TBA value, and the development of browning during the storage were measured and reaction kinetically analysed to assess quality stability and shelf-life of the product for the storage at room temperature of 25$^{\circ}C$. The extent of browning was accelerated with the increase of water activity and temperature marking the time to reach a limit of color and flavor deterioration, or to reach brown color density of 0.17 O.D./g at 420nm, 106 days at a$\_$w/=0.44, 35$^{\circ}C$, and 41 days at aw=0.65, 55$^{\circ}C$. These reaction rates resulted in a prediction of shelf-life, 130 to 110 days in the storage at au=0.44 to 0.75, 25$^{\circ}C$. The quality limit assessed by TBA values and sensory evaluation of rancidity was 87 days at a$\_$w/=0.44, 35$^{\circ}C$, and 30 days at aw=0.73, 55$^{\circ}C$ which gave a predicted shelf-life, 128 to 113 days at a$\_$w/=0.44 to 0.75, 25$^{\circ}C$ storage.

  • PDF

Optimization and kinetic modeling for bioconversion of cheese whey to Ganoderma lucidum in batch fermentations

  • Song, Min-Gyeong;Lee, Hwan-Yeong;Hwang, Seok-Hwan
    • 한국생물공학회:학술대회논문집
    • /
    • 2002.04a
    • /
    • pp.381-384
    • /
    • 2002
  • Response surface methodology (RSM) was successfully applied to optimize for the production of Ganoderma lucidum in batch fermentations using the whey (40,000 mg latose/L) as substrate. This study was performed according to the central composite design (CCD) with respect to pH and temperature, where the designed intervals were 3.3$22.9^{\circ}C$$37.1^{\circ}C$, respectively. A second-order factorial design of the experiments was used to build empirical models providing a quantitative interpretation of the relationships between the two variables. The optimum conditions to maximize the production of G. lucidum were pH 4.2 and $28.3^{\circ}C$. At optimum conditions, the mycelial dry weight (MDW) and residual soluble COD (SCOD) were simultaneously used to evaluate the biokinetic coefficients assocoated with substrate inhibition model by nonlinear least squares method with 95% confidence interval. The. maximum microbial growth rates (${\mu}m$), half saturation coefficient ($K_s$), and the inhibition substrate concentration ($K_{is}$) were determined to be 0.095 l/hr, 128,000 mg SCOD/L and 49,000 mg SCOD/L, respectively. And the microbial yield coefficient (Y), biomass decay rate coefficient ($K_d$), and the maintenance energy coefficient ($m_s$) were determined to be 0.37 mg MDW/mg SCOD, 0.001 1/hr, and 0.0015 1/hr, respectively.

  • PDF

Effect of Maternal Passive Autoimmunization against Myostatin on Growth Performance in Chickens

  • Moon, Y.S.;Lee, H.G.;Yin, Y.H.;Jin, X.;Hong, Z.S.;Cho, J.S.;Kim, S.C.;You, S.K.;Jin, D.I.;Han, J.Y.;Choi, Y.J.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.18 no.7
    • /
    • pp.1017-1021
    • /
    • 2005
  • Myostatin is a negative regulator of skeletal muscle growth and a loss of functional myostatin protein increases muscle hypertrophy and hyperplasia in cattle. The present study was conducted to investigate whether maternal passive immunization against myostatin would improve growth performance in chickens. A complete broiler myostatin cDNA was cloned and it was expressed into two transcripts as 1,128 bp and 985 bp by alternative splicing. A conjugated mature myostatin (350 bp) was used to induce autoimmunization and maternal passively immunized chickens was used for the experiment. It was confirmed that there was a maternal passive immunization against myostatin at zero weeks of age, but its effect was reduced by 6 weeks of age. The auto-immunized groups showed smaller body weights than those of control group during the growing period and the difference was getting bigger with time until 6 weeks of age. These results suggest that passive autoimmunization against myostatin used in this study is not potent enough to stimulate growth performance in chickens.

Validation of an Enzyme-Immunoassay for Calcitriol in Human Plasma and Evaluation of Its Pharmacokinetics after Single-dose in Korean Volunteers (인체 혈장 중 칼시트리올의 효소면역 분석법 검증 및 단회투여 후 약물동태 연구)

  • Kim, Ye-Tae;Jin, Su-Eon;Kim, Hyun-Ki;Shin, Baek-Ki;Jeong, Ui-Hyeon;Kim, Chong-Kook;Park, Jeong-Sook
    • Journal of Pharmaceutical Investigation
    • /
    • v.39 no.4
    • /
    • pp.309-314
    • /
    • 2009
  • An enzyme immunoassay (EIA) was validated for quantitation of cacitriol in human plasma. Calcitriol was immunoextracted with immunocapsules, which contain monoclonal antibodies to calcitriol linked to solid phase particles in suspension with a vitamin D binding protein inhibitor. Calcitrol was eluated and the eluates were evaporated under a gentle stream of nitrogen gas. The absorbance of analytes was determined using a microplate reader (reference wavelength 650 nm; measurement wavelength 450 nm). The method was specific and sensitive enough to detect as low as 6.5 pmol/L of calcitriol. Linear calibration range was 6.5-491 pmol/L with correlation coefficient greater than 0.99. The overall accuracy was in the range of 83.8 to 111.2% and precision C.V. (%) 0.99 to 8.47%. The recovery was approximately 100% and stability was confirmed during storage and sample preparation. The pharmacokinetic parameters were calculated by baseline subtraction because calcitriol is an endogenous material. Following oral dose of calcitriol, the mean AUC$_{24h}$ was 1038${\pm}$539 pmol/Lhr and C$_{max}$ of 128${\pm}$63.1 pmol/L was reached at 3.50${\pm}$1.07 hr. The mean t$_{1/2}$ of calcitriol was 5.13${\pm}$2.10 hr. The present EIA method was successfully applied to study bioavailability after oral administration of 2 ${\mu}$g of calcitriol in healthy Korean subjects.

The Effects of Post-Treatments for Wet Spun PVDF on the Piezoelectric Property (습식방사 된 PVDF 섬유의 후 처리를 통한 결정구조의 변화)

  • Yu, Seung Mi;Oh, Hyun Ju;Hwang, Sang-Kyun;Chung, Yong Sik;Hwang, Hui Yun;Kim, Seong Su
    • Composites Research
    • /
    • v.26 no.2
    • /
    • pp.123-128
    • /
    • 2013
  • The PVDF (polyvinylidene fluoride) fibers were prepared using the wet spinning processing. To improve ${\beta}$-phase crystalline which closely related piezoelectric property PVDF wet spun fibers conducted post treatment. Post treatment is consisted of heat stretching and annealing process. The heat stretching and annealing conditions were controlled by changing temperature between glass transition temperature and melting temperature. From these experimental data, the resulting crystal structure of the ${\beta}$-phase crystalline was confirmed by FT-IR and XRD experiments. From these analysis results, optimum stretching and annealing conditions of the wet spun PVDF fibers were founded to increase high ${\beta}$-phase crystalline. Furthermore results showed that thermal processing had a direct effect on modifying the crystalline microstructure and also confirmed that heat stretching and annealing could increase the degree of crystallinity and ${\beta}$-phase crystalline. Finally, piezoelectric constant ($d_{11}$) of the post heat treated PVDF fibers reinforced composite were measured to investigate the feasibility for the sensing materials.

Study on Optimal Welding Condition for Shipbuilding Steel Materials (조선강재의 최적 용접조건에 관한 연구)

  • Kim, Ok-Hwan
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.10 no.6
    • /
    • pp.128-133
    • /
    • 2011
  • In this study, the steel material for shipbuilding(LR-A class) was used, and FCAW was taken advantage of 3G attitude and they are welded by different welding ways. As a result of analyzing wave with welding monitoring system, the stable values are obtained which are the first floor(electronic current 164~182 A, voltage 24 V), the second floor(electronic current 174~190 A, voltage 22~25 V), the third floor(electronic current 158~188 A, voltage 22~25 V), and fourth floor(electronic current 172~184 A, voltage 22~25 V), at this time, the stable wave standard deviation and changing coefficient could be obtained. When the welding testing through nondestructive inspection was analyzed know defect of welding, there was no defect of welding in A, D, E, but some porosities in B, and slag conclusion near the surface in C, because the length of arc was not accurate, and the electronic current and voltage was not stable. After observing the change of heat affect zone through micro testing, each organization of floor formed as Grain Refinement, so welding part was fine, the distance of heat affect zone is getting wider up to change the values of the electronic current and voltage. As a result of degree of hardness testing, the hardness orders were the heat affect zone(HAZ), Welding Zone(WZ), and Base Metal(BM). When the distribution of degree of hardness is observed. B is the highest degree of hardness The reason why heat effect zone is higher than welding zone and base metal, welding zone is boiled over melting point($1539^{\circ}C$) and it starts to melt after the result of analysis through metal microscope, so we can know that delicate tissue is created at the welding zone. Therefore, in order to get the optimal conditions of the welding, the proper current of the welding and voltage is needed. Furthermore the precise work of welding is required.

A STUDY OF DETERMINATION OF PHYSIOLOGICAL ROOT APEX BY ELECTRICAL RESISTANCE VALUE (전기저항치에 의한 생리적 근첨(根尖)의 측정에 관한 연구)

  • Yun, Ki-Bock
    • Restorative Dentistry and Endodontics
    • /
    • v.7 no.1
    • /
    • pp.25-31
    • /
    • 1981
  • One of the most important factors for successful endodontic therapy is an accurate length determination of physiological root apex. Some methods suggested for the measurement of root canal length, include digital-tactile sense and roentgenographic technique with measuring wire, scale and grid. But these methods do not derermine an accurate working length to physiological root apex. Recently electronic measuring devices are used to locate the physiological root apex in root canal length determination and these devices are accepted as an effective apparatus. The 89 patients (116 teeth, 144 canals) among the out-patients of Yonsei University Dental Infirmary, who had had an endodontic treatment in the Department of Operative Dentistry, were measured by the Root-Canal Meter$^{(R)}$ as an electronic device, and radiographs to determine the distribution and location of physiological root apex, then the following results were made: (1) Range of ${\pm}$1mm from the radiographic root apex were present in 88.88% (128 canals) of the subjects. (2) Physiological root apex and radiographic root apex were coincided in 31.94% (46 canals) of the subjects. (3) The actual length of the physiological root apex of the teeth were as follow; A : in the maxillary central incisor : 0.46mm B : in the maxillary lateral incisor : 0.44mm C : in the maxillary canine : 0.44mm D : in the maxillary 1st premolar : a) Buccal : 0.59mm b) Lingual : 0.34mm E : in the maxillary 2nd premolar : 0.54mm F : in the maxillary 1st molar : a) Mesio-buccal : 0.50mm b) Disto-buccal : 0.42mm c) Lingual : 0.56mm G : in the mandibular central incisor : 0.62mm H : in the mandibular lateral incisor : 0.45mm in the mandibular canine : 0.54mm J : in the mandibular 1st premolar : 0.47mm K : in the mandibular 2nd premolar : 0.34mm L : in the mandibular 1st molar : a) Mesio-buccal : 0.54mm b) Mesio-lingual : 0.31mm c) Distal : 0.37mm.

  • PDF

Electrophysiological Characteristics of Six Mutations in hClC-1 of Korean Patients with Myotonia Congenita

  • Ha, Kotdaji;Kim, Sung-Young;Hong, Chansik;Myeong, Jongyun;Shin, Jin-Hong;Kim, Dae-Seong;Jeon, Ju-Hong;So, Insuk
    • Molecules and Cells
    • /
    • v.37 no.3
    • /
    • pp.202-212
    • /
    • 2014
  • ClC-1 is a member of a large family of voltage-gated chloride channels, abundantly expressed in human skeletal muscle. Mutations in ClC-1 are associated with myotonia congenita (MC) and result in loss of regulation of membrane excitability in skeletal muscle. We studied the electrophysiological characteristics of six mutants found among Korean MC patients, using patch clamp methods in HEK293 cells. Here, we found that the autosomal dominant mutants S189C and P480S displayed reduced chloride conductances compared to WT. Autosomal recessive mutant M128I did not show a typical rapid deactivation of Cl- currents. While sporadic mutant G523D displayed sustained activation of $Cl^-$ currents in the whole cell traces, the other sporadic mutants, M373L and M609K, demonstrated rapid deactivations. $V_{1/2}$ of these mutants was shifted to more depolarizing potentials. In order to identify potential effects on gating processes, slow and fast gating was analyzed for each mutant. We show that slow gating of the mutants tends to be shifted toward more positive potentials in comparison to WT. Collectively, these six mutants found among Korean patients demonstrated modifications of channel gating behaviors and reduced chloride conductances that likely contribute to the physiologic changes of MC.

The Evaluation of the Radiation Dose and Image Quality Through the Change of the Tube Voltage in Cerebral CT Angiography (전산화단층촬영장치를 이용한 뇌 혈관조영 검사에서 관전압 변화에 따른 방사선량과 영상의 질 평가)

  • LEE, Ji-Won;Jung, Kang-Kyo;Cho, Pyong-Kon
    • Journal of radiological science and technology
    • /
    • v.38 no.2
    • /
    • pp.121-126
    • /
    • 2015
  • To image diagnosis in neurovascular diseases using Multi-Detector Computed Tomography(MDCT), injected the same contrast material when inspecting Brain Computed Tomography Angiography(BCTA) to examine radiation dose and Image quality on changing Cerebral Artery CT number by tube voltage. Executed an examination with same condition[Beam Collimation $128{\times}0.6mm$, Pitch 0.6, Rotation Time 0.5s, Slice Thickness 5.0mm, Increment 5.0mm, Delay Time 3.0sec, Care Dose 4D(Demension ; D)] except for tube voltage on 50 call patients for BCTA and divided them into two groups (25 people for a group, group A: 80, group B: 120kVp). From all the acquired images, set a ROI(Region of Interest) on four spots such as left cerebral artery, right cerebral artery, posterior cerebral artery and cerebral parenchyma to compare quantitative evaluation, qualitative evaluation and effective dose after measuring CT number value from Picture Archiving Communications System(PACS). Evaluating images with CT number acquired from BCTA examination, images with 80 kVp was 18% higher in Signal to Noise Ratio and 19% in Contrast to Noise Ratio than those with 120 kVp. It was seen that expose dose was decreased by over 50% with tube voltage 80 kVp than with 120 kVp. Group A (25 patients) was examination with tube voltage 80kVp while group B with 120 kVp to examine radiation dose and Image quality. It is considered effective to inspect with lower tube voltage than with conventional high kVp, which can reduce radiation dose without any affect on diagnosis.