• Title/Summary/Keyword: D value

Search Result 8,591, Processing Time 0.04 seconds

Seasonal variation of species composition by depths in deep sea ecosystem of the East Sea of Korea (동해 심해 생태계의 수심별 종조성 및 계절변동)

  • Sohn, Myoung-Ho;Lee, Hae-Won;Hong, Byung-Kyu;Chun, Yong-Yul
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.46 no.4
    • /
    • pp.376-391
    • /
    • 2010
  • To investigate seasonal variation and species composition by depth layers in the deep sea ecosystem of the East Sea of Korea, bottom trawl survey was conducted at 4 depth layers during spring and autumn from 2007 to 2009. A total of 47 species were collected and were composed of 23 fish species, 9 crustacea, 6 cephalopoda and 9 gastropoda. The main dominant species at each depth layers were Chionoecetes opilio in 300m, Berryteuthis magister in 500m, Chionoecetes japonicus in 700m and 900m. In spring, richness indices (R) showed low value of 2.01 in 500m depth, and high value of 2.16 in 300m depth. Diversity indices (H') showed low value of 1.53 in 300m depth, and high value of 2.09 in 700m depth. Dominance indices (D) showed low value of 0.15 in 700m depth, and high value of 0.31 in 300m depth. In Autumn, richness indices showed low value of 1.48 in 900m depth, and high value of 2.69 in 300m depth. Diversity' indices (H') showed low value of 1.13 in 300m depth, and high value of 2.23 in 700m depth. Dominance indices (D) showed low value of 0.14 in 700m depth, and high value of 0.54 in 300m depth. In spring, similarity analysis in each depth layers showed the difference between 900m and othe depth layer, on the contrary 500m and 700m showed the similarity. In autumn, similarity analyssis in each depth layers showed the difference between 700m and other depth layers, on the contrary 300m and 500m showed the similarity.

Correlation between Value Strategies and Financial Performance in Leading Industries (주력산업에서 가치전략과 재무성과의 상관관계)

  • Hong, Kichul;Park, Kwangho
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.41 no.1
    • /
    • pp.70-83
    • /
    • 2018
  • Korea's five leading industries-chemical, automobile, shipbuilding, metal and electronics-have been the growth engines of the Korean economy for the last 30 years. However, with their performance weakening in the past few years, Korea's annual growth rate has dropped to less than 2%. Just as the Japanese economy struggled through the lost decades, Korea's leading industries have been facing signals of arriving at a Strategic Inflection Point ("SIP") since the mid-2000s. The objective of this study is to present an appropriate value strategy for Korean firms in leading industries to gain sustainable competitive advantages. This paper examines the following issues : First, it diagnoses the signs and timing of SIP for the five leading industries. Second, this study examines 78 Korean and Japanese firms in order to understand the adaptation strategies of the highest and lowest performing firms from a value strategy point of view. Third, it empirically analyzes the correlation between the indicators of value strategy and the accounting performances of the Korean and Japanese firms. The data set used in the cluster analysis were collected from KISLINE database of NICE Information Service and annual reports. The findings in the case analyses of high and low performing companies show that high value-added specialty chemical materials and electronic component manufacturers that had a strong focus on value creation were defined as high performing companies. And in the cosmetic and automobile industries, companies with a strong emphasis on value appropriation gained high performance. Furthermore, the study conducted a cluster analysis based on two indicators R&D and advertisement expense. The analysis shows that a significant gap exists in the operating incomes among three groups classified under the value strategy. The study recommends that Korean firms are requested to increase R&D expenditure, conduct M&A and collaborate with companies that own source technologies to narrow the technology gap and improve their segment portfolio from commodity to value-added products.

Hematological Reference Values in the Healthy Adults (건강성인의 혈구 참고치 산정)

  • Kim, Young-Jin;Hyun, Myung-Soo;Lee, Hyun-Woo
    • Journal of Yeungnam Medical Science
    • /
    • v.8 no.1
    • /
    • pp.154-165
    • /
    • 1991
  • To establish the hematological reference values in the healthy adults visited our hospitals, following examination were done on 2823 persons by Coulter Counter Model S-plus II ; white blood cell count: (WBC), red blood cell count(RBC), hemoglobin(Hb), hematocrit(Hct), mean corpuscular volume (MCV), mean corpuscular hemoglobin(MCH), mean corpuscular hemoglobin concentration(MCHC), red cell distribution width(RDW), platelet, plateletcrit, mean platelet volume(MPV) and platelet distribution width(PDW). The following results are obtained. 1) Male, mean value of WBC ; $6,800{\pm}2,680(2SD)/{\mu}l$ Female, mean value of WBC ; $5,950{\pm}2,380(2SD)/{\mu}l$ 2) Male, mean value of RBC ; $428{\pm}60(2SD){\times}10^4/{\mu}l$ Female, mean value of WBC ; $415{\pm}56(2SD){\times}10^4/{\mu}l$ 3) Male, mean value of Hb ; $15.4{\pm}1.8(2SD)g/dL$ Female, mean value of Hb ; $13.0{\pm}1.6(2SD)g/dL$ 4) Male, mean value of Hct ; $45.3{\pm}5.0(2SD)%$ Female, mean value of Hct ; $38.2{\pm}4.6(2SD)%$ 5) Male, mean value of MCV ; $93.8{\pm}5.8(2SD)fL$ Female, mean value of MCV ; $92.2{\pm}7.4(2SD)fL$ 6) Male, mean value of MCH ; $31.8{\pm}2.2(250)pg$ Female, mean value of MCH ; $31.4{\pm}2.8(2SD)pg$ 7) Male, mean value of MCHC ; $34.0{\pm}1.2(2SD)%$ Female, mean value of MCHC ; $33.9{\pm}1.2(2SD)%$ 8) Male, mean value of RDW ; $12.7{\pm}1.0(2SD)%$ Female, mean value of RDW ; $12.6{\pm}1.4(2SD)%$ 9) Male, mean value of Platelet ; $242.9{\pm}87.8(2SD){\times}10^3/{\mu}l$ Female, mean value of Platelet ; $242.2{\pm}89.0(2SD){\times}10^3/{\mu}l$ 10) Male, mean value of Plateletcrit ; $0.201{\pm}0.076(2SD)%$ Female, mean value of Plateletcrit ; $0.204{\pm}0.076(2SD)%$ 11) Male, mean value of MPV ; $8.20{\pm}1.70(2SD)fl$ Female, mean value of MPV ; $8.36{\pm}1.82(2SD)fl$ 12) Male, mean value of PDW ; $16.1{\pm}0.8(2SD)%$ Female, mean value of PDW ; $16.0{\pm}0.8(2SD)%$.

  • PDF

Correlation between Skin Translucency and Scattering Reflection using Miniaturized New Optical Device (피부 투명감 측정 기기의 소형화 및 피부의 확산 반사광과 투명감 사이의 연구)

  • Lee, Myeong-Ryeol;Jeong, Choon-Bok;Junng, Yu-Chul;Kim, Han-Kon;Nam, Gae-Won
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.37 no.2
    • /
    • pp.121-127
    • /
    • 2011
  • Skin darkness is the source of trouble to many women. Skin darkness is the state that while skin redness and brightness are reduced, skin yellowness is increased. Skin translucency which is measured by skin color, especially brightness is an another expression of skin darkness. Skin brightness is usually expressed by L value of $L^{*} \;a^{*}\; b^{*}$ (CIELAB color space system). However, it is hard to find the relationship between L value and perceptive efficacy such as translucency because the L value is just a factor of evaluation of skin darkness. The skin with high translucency has high scattering reflective light value than low value. In this study, we measured the skin translucency of 20 ~ 30 ages men and women face by both our designed previous device which use polarized light to detect surface and scatter reflective light independently and $Lumiscan^{TM}$ which is improved designed to confirm our new device working ability by calculation of relationship between trnaslucency and scattering reflective light value. The result of this study indicate that there is a high correlation (R = 0.732, p < 0.01) between translucency and scattering reflective light value, and suggest that $Lumiscan^{TM}$ is portable and easy measuring device more that previous device.

Influence of slice thickness of computed tomography and type of rapid protyping on the accuracy of 3-dimensional medical model (CT절편두께와 RP방식이 3차원 의학모델 정확도에 미치는 영향에 대한 연구)

  • Um Ki-Doo;Lee Byung-Do
    • Imaging Science in Dentistry
    • /
    • v.34 no.1
    • /
    • pp.13-18
    • /
    • 2004
  • Purpose : This study was to evaluate the influence of slice thickness of computed tomography (CT) and rapid protyping (RP) type on the accuracy of 3-dimensional medical model. Materials and Methods: Transaxial CT data of human dry skull were taken from multi-detector spiral CT. Slice thickness were 1, 2, 3 and 4 mm respectively. Three-dimensional image model reconstruction using 3-D visualization medical software (V-works /sup TM/ 3.0) and RP model fabrications were followed. 2-RP models were 3D printing (Z402, Z Corp., Burlington, USA) and Stereolithographic Apparatus model. Linear measurements of anatomical landmarks on dry skull, 3-D image model, and 2-RP models were done and compared according to slice thickness and RP model type. Results: There were relative error percentage in absolute value of 0.97, 1.98,3.83 between linear measurements of dry skull and image models of 1, 2, 3 mm slice thickness respectively. There was relative error percentage in absolute value of 0.79 between linear measurements of dry skull and SLA model. There was relative error difference in absolute value of 2.52 between linear measurements of dry skull and 3D printing model. Conclusion: These results indicated that 3-dimensional image model of thin slice thickness and stereolithographic RP model showed relative high accuracy.

  • PDF

Multicast Model and Application of Group Communication System using Trigger (트리거를 이용한 그룹통신시스템의 멀티캐스트모델 및 응용)

  • Ryu Kwon-Yeol
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.10 no.7
    • /
    • pp.1222-1228
    • /
    • 2006
  • In this paper, I propose a video watermaking method using adaptive threshold value and half-cell motion vector. Conventional method cause a lot of change of motion vectors and bring about a falling-off in invisibility, because it search embedding condition about whole macroblocks and watermarks are embedded in arbitrary motion vectors. Proposed method improve invisibility and decrease in number of change of motion vectors, because it create threshold value by using power of motion vector(PMV), and watermarks are embedded in motion vectors which greater than threshold value. Consequently, proposed method improve invisibility with on an average 5.4 dB ~9.3dB according to video bit-stream.

A Study on the Alkali Hydrolyzed Properties of Polyester Fabric by Various Denier Reduction Range (감량가공기계에 따른 폴리에스터 직물의 감량특성에 관한 연구)

  • 허만우;서말용;박성우;한선주;김삼수;이재웅;황종호
    • Textile Coloration and Finishing
    • /
    • v.12 no.2
    • /
    • pp.111-120
    • /
    • 2000
  • In order to make a silk-like polyester fabric, polyester fabrics were treated with a several weight reduction machines such as tank type, liquor flow type and C.D.R at the field condition. The results were as followings : The weft density of treated polyester fabric showed different tendency according to the used the weight reduction machine and the rate of weight loss. Namely, at 6.5% weight loss, the weft density of fabric treated with tank and liquor flow type increased by 1 pick/inch and 2 picks/inch, respectively, and decreased by 4 picks/inch in case of treated with C.D.R type. With the increase in the rate of weight loss, the air permeability of treated fabric increased, and the K/S value of dyed fabric decreased. The overall tendency of the air permeability and the K/S value of treated polyester fabric increased in the order of the tank type, liquor-flow type and C.D.R type. The tensile strength of polyester fabric treated with C.D.R had lower value than that of the other type. It is assumed that this result is attributed the decreasing of the cross point of the warp and weft direction.

  • PDF

Effects of D-Fructose on the Uptake of Iron by the Intestinal Brush-Border Membrane Vesicles from Rats.

  • Kim, Ok-Seon;Lee, Yong-Bok;Oh, In-Joon;Koh, Ik-Bae;Lee, Yeong-Woo
    • Journal of Pharmaceutical Investigation
    • /
    • v.24 no.3
    • /
    • pp.11-18
    • /
    • 1994
  • We have studied the iron uptake by the purified brush-border membrane vesicles (BBMVs) to determine the effect of fructose on the absorption of iron. BBMVs were prepared by the modified calcium precipitation method, The degree of purification was routinely assessed by the marker enzyme, alkaline phosphatase, and the functional integrity was tested by $D-[1-^3H]glucose$ uptake. The appearance of membrane vesicles was shown by transmission electron microscopy (TEM). The uptakes of complexes of labeled iron $[^{59}Fe]$ with fructose and ascorbate were measured with a rapid filtration technique, The uptake rate and pattern of the two iron-complexes, Fe(III)-fructose and Fe(III)-ascorbate, were also observed. A typical overshooting uptake of D-glucose was observed with peak value of $2{\sim}3$ times higher concentration than that at equilibrium. This result was similar to other studies with BBMVs. TEM showed that the size of BBMVs was uniform and we can hardly find any contaminants, Fe(III)-fructose has the higher value of $V_{max}$ and the lower value of Km than those of Fe(III)-ascorbate, respectively. It may be concluded that D-fructose is more effective in promoting the iron absorption than ascorbate.

  • PDF

HU Threshold Value for IV Catheter Fragment in Peripheral Vein of Volume Rendering 3D MDCT Imaging (정맥 내의 IV 카테터 조각을 3D MDCT 볼륨렌더링 영상으로 구현하기 위한 HU 임계치)

  • Jang, Keun-Jo;Kweon, Dae-Cheol
    • The Journal of the Korea Contents Association
    • /
    • v.7 no.4
    • /
    • pp.206-212
    • /
    • 2007
  • To evaluate the HU value of the IV catheter fragment of CT on the accuracy and size in the peripheral vein. Pilot study of profile and table functions on PC by software was calculated of HU value of IV catheter fragment. This study demonstrates the utility of volume rendering technique to localize a small, subtle IV catheter, which can easily be reformatted of MDCT reformations. IV catheter fragment optimal image described as threshold range. Volume rendering of HU using a MDCT is an excellent method for evaluation the IV catheter fragment in three dimension.

Characterization of Noise Exposure in the Tank Gun Drill Ranges (군대 전차포 훈련장에서의 소음노출 특성)

  • Hwang, Sung Ho;Park, Jae Bum
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.24 no.1
    • /
    • pp.74-78
    • /
    • 2014
  • Objectives: Purpose of this study was to evaluate the noise level exposures at the different cannonball type and locations in the tank gun drill ranges. Methods: We visited the tank gun drill ranges and measured with a sound level meter(3M Quest SoundPro$^{TM}$) with the value of Peak(dB(A)). Results: The highest peak value of impulse noise level averaged 166.3 dB(A) at the site of loading solider. The highest peak value of impulse noise level by size of cannonball averaged 165.9 dB(A) at the 120 mm size cannonball of the tank. This result was significantly different from the other size of cannonballs such as 7.62 mm, 90 mm, and 105 mm(p < 0.001). Among the four types of soldier site on the tank, average noise levels of loading soldier, 156.6 dB(A), were higher than the other three types of soldier site (p > 0.05). Conclusions: This study confirmed that there were needed for a proper control to reduce the amount of impulse noise exposure at the tank gun drill ranges.