• Title/Summary/Keyword: D value

Search Result 8,591, Processing Time 0.039 seconds

Value-added Polyolefin Products

  • Ok, Myung-Ahn
    • Proceedings of the Polymer Society of Korea Conference
    • /
    • 2006.10a
    • /
    • pp.152-152
    • /
    • 2006
  • Polyolefins show a very healthy growth rate among commodity polymer resins due to their low feedstock prices, recyclable and environmentally friendly characteristics and easily controllable performances. Capacity investment in polyolefin field is now moving from technology region to consumer region and feedstock region. Therefore, key success factors for polyolefin business in the other region such as Korea are cost reduction, development of highly value-added products and new applications and substitution of PVC, PS, PET and other EPs. To add additional value to commodity polyolefin products, high level of platform technology such as catalyst, process and structure-properties relationship is needed. Progress on polyolefin products has been very closely related to catalyst and process technology. According to this trend, SK Corporation has devoted a lot of research effort into development of new value-added polyolefin products based on the proprietary technology platform.

  • PDF

An Analysis of Partial Discharge by the Optimum Method of Threshold Value (기준치(Threshold Value) 최적화 기법을 이용한 부분방전 해석)

  • Choi, I.H.;Yun, J.W.;Kweon, D.J.;Jung, G.J.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2277-2279
    • /
    • 1999
  • We have investigated the characteristic analysis of ultrasonic in case of occurring partial discharge in experimental steel chamber. This study presents the discriminative method of partial discharge by optimum threshold value. We have carried out the experiments of measuring partial discharge numbers between ultrasonic sensor and transducer with changing distance and barrier inside steel chamber. After the measured data were trasformed A/D conversion by GPIB, we used the optimum method of threshold value for counting numbers of partial discharge.

  • PDF

Private Value of Innovation (Patents) (기술혁신(특허)의 사적가치)

  • Kim, Byung-Woo
    • Journal of Korea Technology Innovation Society
    • /
    • v.14 no.2
    • /
    • pp.246-259
    • /
    • 2011
  • Examining the relation between market structure and the value of innovation is important for competition and STI policy. If the value is large in a specific industry structure, government may lead the industry to take that form to enhance innovation. Our simple calibration in the case of linear demand and constant Me results in the conclusion that the incentive for R&D in the case of major and minor innovation in Cournot competition is less than that of merger and cooperative R&D. This emphasizes again "necessary evil" as a monopoly for innovation.

  • PDF

Using Analytic Network Process to Establish Performance Evaluation Indicators for the R&D Management Department in Taiwan's High-tech Industry

  • Liu, Pang-Lo;Tsai, Chih-Hung
    • International Journal of Quality Innovation
    • /
    • v.8 no.3
    • /
    • pp.156-172
    • /
    • 2007
  • The high-tech industry is the economic lifeline for Taiwan. Its characteristics are short product life cycle, rapid changes in the market, and a high obsolescence rate for new products. Under globalization, the high-tech industry has adopted Information Technology (IT) to shorten the manufacturing process, reduce costs and conduct product research and development (R&D) to increase the core competence of enterprises and achieve the goal of sustainable operations. Enterprises should actively strengthen their integration with internal and external resources and lead in R&D management to increase industrial operating performance. Effectively managing operations and R&D management evaluation in Taiwan's High-tech Industry has become a critical subject. This study adopted 4 major Balanced Scorecard (BSC) perspectives to establish the Total Performance Evaluation Indicators for the R&D management department in Taiwan's High-tech Industry. The Analytic Network Process (ANP) was applied to evaluate the overall performance of the R&D management department. The research framework is divided into 2 phases. The first phase is combined with the 4 major perspectives, Financial, Customer, Internal Business Process and Learning and Growth, as the related indicators for each measurement perspective. The Key Performance Indicators (KPI) were selected using Factor Analysis to identify the key factor from the complicated indicators. The relationship between the characteristics of each BSC's evaluation perspective is dependence and feedback. This study applied ANP to conduct the calculation and adjustment of correlation between each KPI, and determine on their relative weights for the objective KPI. The "Financial Perspective" for R&D management department in Taiwan's High-tech Industry focused on the budget achievement rate of R&D management. The weight indicator value is (0.05863). The "Customer Perspective" focused on problem-solving satisfaction. The weight value of this indicator is (0.17549). The "Internal Business Process Perspective" focused on the quantity and quality of R&D. The weight value of this indicator is (0.13506). The "Learning and Growth Perspective" focused on improving competence in the research personnel's professional techniques. The weight value of this indicator is (0.02789). From the total weighting indicators, the order of the Performance Indicators for the R&D management department in Taiwan's High-tech Industry is: (1) Customer Perspective; (2) Internal Business Process Perspective; (3) Financial Perspective; and (4) Learning and Growth Perspective.

Effects of Injection Configuration on Mixing in Supersonic Combustor

  • Sakamoto, Hayato;Matsuo, Akiko;Mitani, Tohru
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2004.03a
    • /
    • pp.48-54
    • /
    • 2004
  • The effects of injector spacing s and injector diameter d on mixing are numerically investigated in supersonic combustor with perpendicular injection behind a backward-facing step. Simulations are reported for airstream Mach number of 2.4. Parameters are changed on following 4 cases to investigate the effects of injector configuration on mixing efficiency $\eta_m$. In the case of varying d or s, dynamic pressure ratio $Rq(=(pu^2)_j/(pu^2)_a)$ is also varied to keep bulk equivalence ratio $\Phi({\oe})Rq.d^2/s)$ constant. (l) Injector spacing s is varied at constant $\Phi$=0.5, 1, 2 for injector diameter d=6mm. In the case of $\Phi$=1, $\eta_m$ has its maximum value at s=24mm. The reason is that increase of $\eta_m$. , by widening spacing at Rq=constant competes with decrease of $\eta_m$ by increasing Rq at s=constant. When spacing is narrow, the flow field of vicinity of injector becomes two-dimensional because adjacent jets interferes each other. By widening spacing, air is easily entrained by three-dimensional effect. This mechanism also appears in the case of $\Phi$=0.5, 2 for d=6mm, and $\eta_m$. reaches its maximum value at s=24mm for $\Phi$=0.5 and at s=42mm for $\Phi$=2. (2) In the case of injector diameter d varied at $\Phi$=1 for s=30mm, $\eta_m$. has its maximum value at d=3mm. The reason is that decrease of $\eta_m$ by increasing injector diameter competes with increase of $\eta_m$ by decreasing Rq at d=constant.(3) In the case of s varied at $\Phi$=0.5, 1,2 for d=3mm, the injector spacing at which mixing efficiency has its maximum value is s= 18mm for $\Phi$=0.5, s=24mm for $\Phi$=1, s=24mm for $\Phi$=2. Therefore it is found that d=3mm and s=24mm can be optimum configuration over a range of $\Phi$=0.5~2.(4) The effect of h on the optimum spacing is investigated. s is varied for d=6mm at step height h=4, 6, 8mm. The simulation results do not show significant change on the step height.

  • PDF

The direct digital frequency synthesizer of QD-ROM reduction using the differential quantization (차동 양자화를 사용한 QD-ROM 압축 방식의 직접 디지털 주파수 합성기)

  • Kim, Chong-Il;Lim, So-Young;Lee, Ho-Jin
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.8 no.3
    • /
    • pp.192-198
    • /
    • 2007
  • In this paper, a new method to reduce the size of ROM in the direct digital frequency synthesizer(DDFS) is proposed. The new ROM compression method can reduce the ROM size by using the two ROM. The quantized value of sine is stored by the quantized-ROM(Q-ROM) and the differential ROM(D-ROM). To reduce the ROM size, we use the differential quantization technique with this two ROM. First, we quantize the quarter sine wave with the $2^L$ address and store the quantized value at the Q-ROM. Second, after the $2^L$ address are equally divided into $2^M$ sampling intervals, the sampling value is quantized. And the D-ROM store only the difference between this quantized value and the Q-ROM. So the total size of the ROM in the proposed DDFS is significantly reduced compared to the original ROM. The ROM compression ratio of 67.5% is achieved by this method. Also, the power consumption is affected mostly by this ROM reduction.

  • PDF

A Study on the Change of Corneal Refractive Power before and after Wearing RGP Contact Lenses by Flat Fitting and Alingment Fitting with Diagnostic Method (RGP 콘택트렌즈의 진단적 피팅법에 의한 플랫한 피팅과 얼라인먼트 피팅 착용 전·후 각막 굴절력의 변화에 관한 연구)

  • Lee, Dae-Won;Kim, In-Suk
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.2
    • /
    • pp.163-169
    • /
    • 2014
  • Purpose: This study is for compared the change of corneal refractive power before and after wearing of rigid gas permeable contact lense with diagnostic method which is 1 D flatter than alignment fitting on right eye and alignment fitting on left eye for 2 months and investigate the preference. Methods: Twenty middle school and high school students (40 eyes) who had never worn a contact lense before for no corneal topographical change, no ocular disease, no experience of ophthalmic surgery and have normal tear amount were selected for this study and corneal refractive power were examined before wearing rigid gas permeable contact lense and adaptation status and corneal examination were performed after 10 days of wearing and after cheking up the continuation of wearing, all candidate wear contact lens 8 hours per day for 2 month and corneal refractive power were compared. Results: After 2 months of wearing with 1 D flatter than the alignment fitting on right eyes, there was significant difference in the central corneal refractive power was $43.84{\pm}1.33D$, flat K power was $43.05{\pm}1.29D$, and steep K power was $44.61{\pm}1.42D$ decreased than before wearing (p<0.001, 0.001, 0.047). The e-value of the principal meridians also shows statistically significant difference (p=0.037, 0.015). After 2 months of wearing with alignment fitting on left eyes, the central corneal refractive power was $44.40{\pm}1.26D$, flat K power was $43.57{\pm}1.23D$. and flat K e-value was $0.58{\pm}0.05$ which showed no statistically significant difference (p = 0.769, 0.614, 0.181). But steep K power was $45.25{\pm}1.36$, and steep K e-value was $0.45{\pm}0.18$ which shows statistically significant difference (p=0.018, 0.027). Conclusions: Consider the comfort, clear vision, dryness for preference fitting investment, 6 students (30%) prefer right eye which is 1 D flatter fitting, 14 students (70%) prefer left eye which is alignment fitting. For rigid gas permeable fitting needed for accurate examination and should prescribe the alignment fitting which is suitable for each cornea.

ANALYSIS OF OPTICAL TRANSMISSION CHARATERISTICS BY VISIBLE LIGHT INTO SHADE GHIDES (가시광선영역에서 shade guide에 따른 광투과도 특성 연구)

  • Choi, Keun-Bae;Park, Charn-Woon;Song, Chang-Yong;Ko, Sok-Min
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.38 no.2
    • /
    • pp.147-159
    • /
    • 2000
  • The purpose of this study was the evaluation of spectral transmission of the commercial three shade guides and the relationship of hue, value, and chroma according to the transmission rate. The spectral transmittance of three shade guides - Vita Lumin Shade Guide, Vintage and Unibond Shade Guide, and Vitapan 3D-Master Shade Guide - were measured. For direct transmission measurements, each shade tabs were placed at the entrance port of the 1mm diameter intergrating sphere. The intensity of the light source passing through the shade tabs to the right angle was continuously recorded for wavelength from 400 to 700 nm. A transmission spectrum and digital data were obtained for each measurement and they were evaluated using Microcal Origin program. The obtained results of this study were as follows : 1. In Vita Lumin Shade Guide, sum of the transmission rate of the shade tabs at the wavelength 400-700nm was decreased in agreement with the arrangement order at each A, B, C, D group, except D4 shade tab. However, there were no relationships between the transmission rate of the shade tabs and the value-oriented. 2. In Vintage and Unibond Shade Guide, sum of the total transmission rate of the shade tabs was decreased in agreement with the arrangement order at each A, B, C, B group. When all shade tabs arranged in value-oriented, transmission rate was accord with the order, except D4 shade tab. 3. When shade tabs of the Vitapan 3D-Master Shade Guide have the same value and hue, sum of their total transmission rate decreased in accordance with the chroma-oriented. When the shade tabs have the same value and chroma, there were no differences from the order of the transmission rate to the various hue type. However, in the 'R' tabs of reddish hue type, the transmission rate increased at the long wavelength range area. In conclusion, we need the quantitative analyzing instruments in transmission determination. Vitapan 3D-Master Shade Guide covers the tooth color space taking into account the parameters of the systematic value, chroma, hue oriented, and the transmission rate relatively accorded with that sequence.

  • PDF

Quality Factor Determination and Shelf-Life Prediction of Emulsified Ginseng Drink (인삼 유화 음료의 품질 인자 규명 및 저장 수명 예측)

  • Baik, Eun-Kyung;Seo, Yong-Ki;Lee, Geun;Lee, Dong-Un;Park, Seok-Jun;Lee, Jin-Hee;Lee, Kang-Pyo;Kim, Dong-Seob;Hur, Nam-Yun;Baik, Moo-Yeol
    • Korean Journal of Food Science and Technology
    • /
    • v.37 no.4
    • /
    • pp.597-602
    • /
    • 2005
  • Quality factors of emulsified ginseng drink were determined during storage at various temperatures, and its shelf-life was predicted based on changes in emulsion stability, acidify, viscosity, and yellowness. Viscosity was highly dependent on storage temperature. Emulsion stability changed rapidly during early storage period (1st step), then slowly thereafter (2nd step). $Q_{10}$ values of emulsion stability were 2.50 and 1.38 for 1st and 2nd steps, respectively. Viscosity, acidity, and yellowness showed $Q_{10}$ values of 3.45, 1.77, and 1.99, respectively. Although $Q_{10}$ value of 2 has been generally used to predict shelf stability of food materials, our results suggest adopting same $Q_{10}$ value to predict shelf stability of emulsified ginseng drink is not appropriate.

Measurement and evaluation of speech privacy in university office rooms (대학 내 사무실의 스피치 프라이버시 측정 및 평가)

  • Lim, Jae-Seop;Choi, Young-Ji
    • The Journal of the Acoustical Society of Korea
    • /
    • v.38 no.4
    • /
    • pp.396-405
    • /
    • 2019
  • The speech privacy of closed office rooms located in a university campus was measured and assessed in terms of SPC (Speech Privacy Class) values. The measurements of two quantities, the LD (Level Difference) between a source and a receiving room, and the background noise level ($L_b$) at the receiving room were carried out in 5 rooms located in 3 different buildings in the university campus. Each of the 5 rooms was adjacent to both offices and corridors through walls. The TL (Transmission Loss) between the source and the receiver room was also measured to compare the difference of two standard methods, ASTM E2836-10 and KS F 2809. The present results show that the speech privacy of the 5 office rooms is not met the requirement for a minimum SPC values of 70. A minimum LD value of 41 dB between the source and the receiver room should be achieved for having a SPC value of 70 when the mean measured value of $L_b$ at the receiving room is 29.2 dB. That is, the TL(avg) value averaged over the octave bands from 160 Hz to 5000 Hz between the source and the receiver room should be or greater than 40 dB. The most important architectural factor influencing the LD value is the presence of openings, such as doors, and windows, on the adjacent walls between the source and receiving room. Therefore, if the opening of the adjacent wall is replaced by an opening with high sound insulation, the appropriate SPC value of the research and office rooms can be achieved.