• Title/Summary/Keyword: D/d ratio

Search Result 9,650, Processing Time 0.042 seconds

Slaughterhouse wastewater treatment in a bamboo ring anaerobic fixed-bed reactor

  • Tritt, Wolfgang P.;Kang, Ho
    • Environmental Engineering Research
    • /
    • v.23 no.1
    • /
    • pp.70-75
    • /
    • 2018
  • A pilot scale anaerobic fixed-bed with a reactor volume of $2.8m^3$ was built to treat slaughterhouse wastewater. Bamboo rings were chosen as support media mainly because of their cheaper price in underdeveloped countries. Even with their lower porosity and specific surface, the reactor performance showed a maximum 95% COD removal efficiency at an organic loading rate (OLR) of $1kg\;COD/m^3-d$ with its corresponding hydraulic retention time (HRT) of 7.5 d. At a higher OLR of $4.0kg\;COD/m^3-d$, the COD removal efficiency of 75% was achieved with an HRT of 2 d. No big difference in COD removal efficiencies was found between the reactors operated in both upflow and downflow modes. Their operational behavior and effluent characteristics were similar. The effluent COD/TKN ratio of 6.67 at an OLR of $4.0kg\;COD/m^3-d$ was only marginal acceptable range for a subsequent biological denitrification process. Otherwise carbon supplementation is required at a lower OLR.

Oversampled Sigma-Delta A/D Converters Designed by Bilinear Transform (쌍선형 변환에 의한 과표본화율의 시그마-델타 A/D 변환율)

  • Park, Chong-Yeun
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.27 no.5
    • /
    • pp.808-815
    • /
    • 1990
  • This paper treats with the design method for the single loop oversampled Sigma-Delta A/D converter with one delay and the digital integrator. Such an integrator was kgenerated by means of the bilinear transform of the analog integrator. The frequency spectrums of the quantizer and the decimator output signal are evaluated by FFT respectively. With the performance evaluation system, the values of SNR are obtained versus the input sinusoidal signal amplitude, frequency, the oversampling ratio, the DC-input level, the loop gain and the limitting value of the integrator. As compared with existing results, values of SNR versus the input signal amplitude and the oversampling ratio for the suggested system are about 6dB higher then previously reported results respectively. Furthermore, this approach achieves an about 60dB input dynamic range.

  • PDF

Low Spurious Image Rejection Mixer for K-band Applications

  • Lee, Moon-Que;Ryu, Keun-Kwan;Kim, Hyeong-Seok
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.4C no.6
    • /
    • pp.272-275
    • /
    • 2004
  • A balanced single side-band (SSB) mixer employing a sub-harmonic configuration is designed for up and down conversions in K-band. The designed mixer uses anti-parallel diode (APD) pairs to effectively eliminate even harmonics of the local oscillator (LO) spurious signal. To reduce the odd harmonics of LO at the RF port, we employ a balanced configuration for LO. The fabricated chip shows 12$\pm$2dB of conversion loss and image-rejection ratio of about 20dB for down conversion at RF frequencies of 24-27.5GHz. As an up-conversion mode, the designed chip shows 12dB of conversion loss and image-rejection ratio of 20 ~ 25 dB at RF frequencies of 25 to 27GHz. The odd harmonics of the LO are measured below -37dBc.

The Study on the Effect of R&D Investment and Technology Commercialization Capabilities on Business Performance (R&D투자가 경영성과에 미치는 영향: 기술사업화 능력의 매개효과를 중심으로)

  • Lee, Sung-Hwa;Cho, Kuen-Tae
    • Journal of Technology Innovation
    • /
    • v.20 no.1
    • /
    • pp.263-294
    • /
    • 2012
  • The purpose of this study is to examine the effect on R&D investment and technology commercialization capabilities on business performance of 118 Korean firms which has R&D center. In particular, this study tried to define technology commercialization and technology commercialization capabilities for the board and narrow perspective, and investigates the role of technology commercialization capabilities in linking R&D investment and business performance in terms of a financial performance as the growing rate of sales, the growing rate of operating income to sales and non-financial performance as the ratio of technology commercialization. The results of this study are as follows. First, the findings of the research indicated that there was a significant positive relationship between R&D investment and business performance as financial and non-financial. Second, the study found that board technology commercialization capability as technology strategic planning, technology process, and technology organization has the mediating effect to R&D investment on business performance as the ratio of technology commercialization. Third, the study found that narrow technology commercialization capability as manufacturing and marketing play a mediating role in terms of business performance as financial and non-financial.

  • PDF

An Experimental Study on the Estimate of Wind Force Coefficient of Transmission Tower Rectangular Frame (철탑 사각골조의 풍력 계수 산정에 관한 실험적 연구)

  • Shin, Koo-Yong;Lim, Jae-Seob;Hwang, Kyu-Seok;Kil, Yong-Sik
    • Journal of Korean Society of Steel Construction
    • /
    • v.23 no.1
    • /
    • pp.73-81
    • /
    • 2011
  • The wind force coefficient of a transmission tower frame shows several characteristics when the section shape, solidity ratio, and wind direction angle are changed. In this study, the wind force characteristics of a transmission tower frame with a basic structure were evaluated using different solidity ratios and wind direction angles in a wind tunnel test. According to the solidity ratio, the size of the structure and the rectangular-frame model of the transmission tower were changed by adding a two-dimensional (2D) or three-dimensional (3D) structure. The transmission tower's rectangular frame was tested by changing the wind direction angle of the 2D-type structure from 0 to $90^{\circ}$ and by changing the wind direction angle of the 3D-type structure from 0 to $45^{\circ}$ Based on the results that were obtained, it can be concluded that the wind force coefficient of a transmission tower frame can be used as preliminary data in deciding the transmission tower's wind load.

Performance Improvement of Perceptual Filter Using Noise Energy Control (잡음 에너지 제어를 통한 지각 필터 성능 개선)

  • Seo Joung-Kook;Cha Hyung-Tai
    • The Journal of the Acoustical Society of Korea
    • /
    • v.24 no.1
    • /
    • pp.43-51
    • /
    • 2005
  • In this paper, we propose an algorithm that improves a tone quality of a noisy audio signal in order to enhance a Performance of perceptual filter using noise energy control. Most of the algorithms which were proposed by the other researchers usually applied a filter using the noise energy acquired from a silent range. In this case. the improvement rate of tone quality decreases if the noise energy is changed by the magnitude or environment variation in a signal frame. But the Proposed method Provides the means to find a food estimated noise through energy control of the estimated noise which is obtained from a silent range. Also we can get the enhancement of tone qualify in low frequency band unlike other methods. To show the performance of the Proposed algorithm, various input signals which had a different signal-to-noise ratio (SNR) such as 5dB, l0dB, 15dB and 20dB were used to test the proposed algorithm. With the proposed algorithm, we could confirm the enhancement of tone quality in terms of segmental SNR (SSNR). noise-to-mask ration (NMR) and mean opinion score (MOS) test.

Pharmacokinetics and Bioequivalence Evaluation of Risperidone in Healthy Male Subjects with Different CYP2D6 Genotypes

  • Cho, Hea-Young;Lee, Yong-Bok
    • Archives of Pharmacal Research
    • /
    • v.29 no.6
    • /
    • pp.525-533
    • /
    • 2006
  • The aim of this study was to evaluate the bioequivalence of risperidone in healthy male subjects representing different CYP2D6 genotypes with respect to risperidone, 9-hydroxyrisperidone (9-OH-risperidone), and active moiety. A total of 506 Korean subjects were genotyped for $CYP2D6^*10$ by means of allele-specific polymerase chain reaction-restriction fragment length polymorphism (PCR-RFLP). Based on the genotype analysis, 24 subjects, 7 homozygous for $CYP2D6^*1$ for $^*10$, and 7 heterozygous for $^*10$, were recruited and received a single oral dose of 2 mg risperidone tablet in this study. Serum concentrations of risperidone and 9-OH-risperidone up to 48 h were simultaneously determined. There were no significant differences of the active moiety, risperidone, and 9-OH-risperidone between the two preparations in AUC_{0-{\propto}}$ and $C_{max}$. The 90% confidence intervals (Cls) for the ratio of means of the log-trans-formed AUC_{0-{\propto}}$ and $C_{max}$ for the active moiety, risperidone, and 9-OH-risperidone were all within the bioequivalence acceptance criteria of 0.80-1.25. The $CYP2D6^*10$ allele particularly was associated with higher serum concentrations of risperidone and the risperidone/9-OH-risperidone ratio compared with the $CYP2D6^*1$ allele. The results demonstrate that the two preparations of risperidone are bioequivalent and it can be assumed that they are therapeutically equivalent and exchangeable in clinical practice. Furthermore, the pharmacokinetic parameters of risperidone and the risperidone/9-OH-risperidone ratio are highly dependent on the CYP2D6 genotypes.

A Study on Calculation of Protection Ratio for Frequency Coordination in Microwave Relay System Networks (M/W 중계 시스템 망의 주파수 조정을 위한 보호비 계산에 대한 연구)

  • Suh Kyoung-Whoan
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.17 no.2 s.105
    • /
    • pp.139-147
    • /
    • 2006
  • This paper suggests an efficient method of protection ratio calculation and shows some results applicable to frequency coordination in microwave(M/W) relay system networks, and the net filter discrimination(NFD) associated with Tx spectrum mask and overall Rx filter characteristics has been examined to obtain the adjacent channel protection ratio. The protection ratio comprises several factors such as C/N of modulation scheme, noise-to-interference ratio, multiple interference allowance, fade margins of multi-path and rain attenuation, and NFD. According to computed results for 6.7 GHz, 64-QAM, and 60 km at BER $10^{-6}$, fade margin and co-channel protection ratio are 41.1 and 75.2 dB, respectively. NFD for channel bandwidth of 40 MHz reveals 28.9 dB at the first adjacent channel, which results in adjacent channel protection ratio of 46.3 dB. In addition, NFD and protection ratio for different systems with channel bandwidth 20 and 40 MHz have been investigated to be used for actual M/W networks. The proposed method provides some merits of an easy calculation, systematic extension, and applying the same concept to frequency coordination in millimeter wave relay system networks.

A Study on the Analysis of the Elevation Blockage Ratio in the Conservation of the Coastal Landscape of Jeju (제주시 해안일주도로의 경관보전을 위한 건축물의 입면차폐도 분석에 관한 연구)

  • Park, Chul-Min;Kim, Sung-Hoon
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.6 no.2
    • /
    • pp.31-42
    • /
    • 2004
  • Although the coastal area of Jeju has already been developed, it has high pressure and demands for development continually increasing due to the increase of tourism and leisure activities. Therefore, the purpose of this study is to present objective guidance for the planning of the buildings on the seaside road with a view which have the largest impact on coastal landscape in order to enhance its visual quality. The results of this study are as follows : 1) It is chief element to make guidance for the use and planning of buildings in the conservation of the coastal landscape. 2) The D/H ratios which immediately influence an angle of elevation are different one another for the whole street. To ensure a sense of openness for the landscape, it is needed to maintain under $27^{\circ}$ angle of elevation, which demands 1~3 D/H ratio. 3) It is important to make 2.4 visual blockage ratio for whole street, but the actual condition is 4.48 ratio on average. To bring down the visual blockage ratio, the W/D ratio needs to be regulated. 4) Various techniques are also needed for lively building styles going with coastal landscape.

  • PDF