• Title/Summary/Keyword: Cytocompatibility

Search Result 16, Processing Time 0.027 seconds

A study on cytocompatibility of ion beam-irradiated chitosan sponges (이온 빔 조사 처리된 키토산 스펀지의 세포적합도에 관한 연구)

  • Ku, Young
    • Journal of Periodontal and Implant Science
    • /
    • v.28 no.2
    • /
    • pp.281-291
    • /
    • 1998
  • Chitosan is a biodegradable and non-toxic material with a molecular weight of 800-1,500Kd which can be obtained in various forms with extraordinary chemical structures and biological characteristics of which enables it to be used in many fields as a biomaterial. Ion irradiation is a useful tool to modify chemical structures and physical properties of high molecular weight polymers. The basic hypothesis of this study is that when surface properties of chitosan in a sponge form are modified with ion beam-irradiation and cell adhesion properties of chitosan would improve and thereby increase the regenerative ability of the damaged bone. The purpose of this study was to illuminate the changes in the cytocompatibility of chitosan sponges after ion beam-irradiation as a preliminary research. Argon($Ar^+$) ions were irradiated at doses of $5{\times}10^{13}$, $5{\times}10^{15}$ at 35 keV on surfaces of each sponges. Cell adhesion and activity of alkaline phosphatases were studied using rat fetal osteoblasts. The results of this study show hat ion beam-irradiation at optimal doses($5{\times}10^^{13}\;Ar^+\;ion/cm^2$) is a useful method to improve cytocompatibility without sacrificing cell viability and any changing cell phenotypes. These results show that ion beam-irradiated chitosan sponges can be further applied as carriers in tissue engineering and as bone filling materials.

  • PDF

Radial Flow Type Bioreactor for Bioartificial Liver Assist System using PTFE Non-Woven Fabric Coated with Poly-amino Acid Urethane Copolymer

  • Miskon, Azizi;Yamaoka, Tetsuji;Uyama, Hiroshi;Kodama, Makoto
    • Proceedings of the Polymer Society of Korea Conference
    • /
    • 2006.10a
    • /
    • pp.259-259
    • /
    • 2006
  • PAU is the block copolymer consists of a small amount of a small amount of poly(${\gamma}-methyl-L-glutamate$) (PMLG) and the polyurethane. The urethane segments are hydrophobic and then strongly interact with the other hydrophobic materials such as PTFE, and the PMLG segments with the ${\alpha}-helix$ structure possess the cytocompatibility. Therefore, PAU can be easily coated onto the PTFE fiber and acts as an artificial extracellular matrix with the high cytocompatibility Results shows, the immobilization, cultured and functions of porcine hepatocytes is greatly improved.

  • PDF

Beneficial Effects of Microwave-Induced Argon Plasma Treatment on Cellular Behaviors of Articular Chondrocytes Onto Nanofibrous Silk Fibroin Mesh

  • Jin, Soo-Chang;Baek, Hyun-Sook;Woo, Yeon-I;Lee, Mi-Hee;Kim, Jung-Sung;Park, Jong-Chul;Park, Young-Hwan;Rah, Dong-Kyun;Chung, Kie-Hyung;Lee, Seung-Jin;Han, In-Ho
    • Macromolecular Research
    • /
    • v.17 no.9
    • /
    • pp.703-708
    • /
    • 2009
  • Silk fibroin scaffolds were examined as a biomaterial option for tissue-engineered cartilage-like tissue. In tissue engineering for cartilage repair using a scaffold, initial chondrocyte-material interactions are important for the following cell behaviors. In this study, the surface of nanofibrous silk fibroin (NSF) meshes was modified by a microwave-induced argon plasma treatment in order to improve the cytocompatibility of the meshes used as cartilaginous grafts. In addition, the effects of a plasma treatment on the cellular behavior of chondrocytes on NSF were examined. The plasma treatment resulted in an increase in the hydrophilicity of NSF meshes suggesting that the cytocompatibility of the mesh might be improved. Furthermore, the human articular chondrocytes showed higher viability on the surface-modified NSF meshes. These results suggest that the surface modification of NSF meshes by plasma can enhance the cellular behavior of chondrocytes and may be used in tissue engineering.

CYTOCOMPATIBILITY OF THERMALLY OXIDIZED TI-AG ALLOYS (열산화 처리된 Ti-Ag 합금의 세포적합성)

  • Kim, Ho-Joong;Oh, Keun-Taek;Ee, Zi-Whan;Kim, Kyoung-Nam;Han, Dong-Hoo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.42 no.4
    • /
    • pp.333-343
    • /
    • 2004
  • Statement of problem: In its preceding work, change in surface characteristics were investigated in consideration that both microtopograpy and macroscopic configuration of implants surface are two of the most important factors, in that they can construct agreeable environment by raising surface energy, to affect osseointegration and biocompatibility explained by cell proliferation. Purpose: This study focused on examining cytocompatibility of dental implants materials Ti-Ag alloys, of which mechanical and electrochemical superiority to cp-Ti or Ti6Al4V were verified, in comparison with that of cp-Ti, and Ti6Al4V. Materials and methods: In this regard, MTT tests for L-929, the fibroblast connective tissues and cell proliferation tests for osteoprogenitor cells, MC3T3-E1 were performed on cp-Ti, Ti6Al4V, and Ti-Ag alloys following thermal oxidation according to appropriate heat treatment temperature(untreated, 400, 600, $800^{\circ}C$) and heat treatment duration(untreated, 0.5, 1, 4 hr). Results: The MTT tests on fibroblasts L-929 resulted in cell viability of over 90% in all experimental group entities, where, especially, the 100% of the viability for Ti-Ag alloys specimens accounted for the slightest adverse effect of ions release from those alloys on the cell. In MC3T3-E1 proliferation tests, the population of cells in the experimental group was roughly increased as experimentation proceeded, after two to four days. Proliferation showed highest viability for most of specimens, including Ti2.0Ag, treated at $600^{\circ}C$. Conclusion: In conclusion, it is the heat treatment temperature, not the duration that has considerable effects on thermal oxidation of specimens. Ti-Ag alloys treated at $600^{\circ}C$ proved to have the best surface morphology as well as cytocompatibility when compared with Ti or Ti6Al4V for short-term biocompatibility tests.

Preparation and characterization of rutile phase TiO2 nanoparticles and their cytocompatibility with oral cancer cells

  • Vu, Phuong Dong;Nguyen, Thi Kieu Trang;Yoo, Hoon
    • International Journal of Oral Biology
    • /
    • v.44 no.3
    • /
    • pp.108-114
    • /
    • 2019
  • In the present study, rutile phase titanium dioxide nanoparticles ($R-TiO_2$ NPs) were prepared by hydrolysis of titanium tetrachloride in an aqueous solution followed by calcination at $900^{\circ}C$. The composition of $R-TiO_2$ NPs was determined by the analysis of X-ray diffraction data, and the characteristic features of $R-TiO_2$ NPs such as the surface functional group, particle size, shape, surface topography, and morphological behavior were analyzed by Fourier-transform infrared spectroscopy, scanning electron microscopy and energy dispersive X-ray spectroscopy, transmission electron microscopy, dynamic light scattering, and zeta potential measurements. The average size of the prepared $R-TiO_2$ NPs was 76 nm, the surface area was $19m^2/g$, zeta potential was -20.8 mV, and average hydrodynamic diameter in dimethyl sulfoxide (DMSO)-$H_2O$ solution was 550 nm. The 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide (MTT) assay and morphological observations revealed that $R-TiO_2$ NPs were cytocompatible with oral cancer cells, with no inhibition of cell growth and proliferation. This suggests the efficacy of $R-TiO_2$ NPs for the aesthetic white pigmentation of teeth.

Antimicrobial and cytotoxic activity of Ferula gummosa plant essential oil compared to NaOCl and CHX: a preliminary in vitro study

  • Abbaszadegan, Abbas;Gholami, Ahmad;Mirhadi, Hosein;Saliminasab, Mina;Kazemi, Aboozar;Moein, Mahmood Reza
    • Restorative Dentistry and Endodontics
    • /
    • v.40 no.1
    • /
    • pp.50-57
    • /
    • 2015
  • Objectives: The usage of medicinal plants as natural antimicrobial agents has grown in many fields including dental medicine. The aim of this in vitro study was three-fold: (i) to determine the chemical compositions of the Ferula gummosa essential oil (FGEO), (ii) to compare the antimicrobial efficacy of the oil with sodium hypochlorite (NaOCl) and chlorhexidine (CHX), (iii) to assess the toxic behavior of FGEO in different concentrations compared to 5% NaOCl and 0.2% CHX. Materials and Methods: Gas chromatography/mass spectrometry (GC/MS) was used to determine the chemical compositions of the oil. The disk diffusion method and a broth micro-dilution susceptibility assay were exploited to assess the antimicrobial efficacy against Enterococcus faecalis, Staphylococcus aureus, Streptococcus mitis, and Candida albicans. The cytocompatibility of the FGEO was assessed on L929 fibroblasts, and compared to that of NaOCl and CHX. Results: Twenty-seven constituents were recognized in FGEO. The major component of the oil was ${\beta}$-pinene (51.83%). All three irrigants significantly inhibited the growth of all examined microorganisms compared to the negative control group. FGEO at $50{\mu}g/mL$ was effective in lower concentration against Enterococcus faecalis than 5% NaOCl and 0.2% CHX, and was also more potent than 0.2% CHX against Candida albicans and Staphylococcus aureus. FGEO was a cytocompatible solution, and had significantly lower toxicity compared to 5% NaOCl and 0.2% CHX. Conclusions: FGEO showed a promising biological potency as a root canal disinfectant. More investigations are required on the effectiveness of this oil on intracanal bacterial biofilms.

Decontamination methods to restore the biocompatibility of contaminated titanium surfaces

  • Jin, Seong-Ho;Lee, Eun-Mi;Park, Jun-Beom;Kim, Kack-Kyun;Ko, Youngkyung
    • Journal of Periodontal and Implant Science
    • /
    • v.49 no.3
    • /
    • pp.193-204
    • /
    • 2019
  • Purpose: The reaction of cells to a titanium implant depends on the surface characteristics of the implant which are affected by decontamination. The aim of this study was to evaluate the cytocompatibility of titanium disks treated with various decontamination methods, using salivary bacterial contamination with dental pellicle formation as an in vitro model. Methods: Sand-blasted and acid-etched (SA) titanium disks were used. Three control groups (pristine SA disks [SA group]; salivary pellicle-coated SA disks [pellicle group]; and biofilm-coated, untreated SA disks [NT group]) were not subjected to any decontamination treatments. Decontamination of the biofilm-coated disks was performed by 14 methods, including ultrasonic instruments, rotating instruments, an air-powder abrasive system, a laser, and chemical agents. MG63 cells were cultured in the presence of the treated disks. Cell proliferation assays were performed on days 2 and 5 of cell culture, and cell morphology was analyzed by immunofluorescence and scanning electron microscopy (SEM). A vascular endothelial growth factor (VEGF) assay was performed on day 5 of culture. Results: The cell proliferation assay revealed that all decontaminated disks, except for the 2 groups treated using a plastic tip, showed significantly less cell proliferation than the SA group. The immunofluorescence and SEM analyses revealed that most groups showed comparable cell density, with the exception of the NT group, in which the cell density was lower and bacterial residue was observed. Furthermore, the cells grown with tetracycline-treated titanium disks showed significantly lower VEGF production than those in the SA group. Conclusions: None of the decontamination methods resulted in cytocompatibility similar to that of pristine SA titanium. However, many methods caused improvement in the biocompatibility of the titanium disks in comparison with the biofilm-coated, untreated titanium disks. This suggests that decontamination is indispensable for the treatment of peri-implantitis, even if the original biocompatibility cannot be restored.

Comparative study on the physicochemical properties and cytocompatibility of microporous biphasic calcium phosphate ceramics as a bone graft substitute (미세다공성 Biphasic calcium phosphate ceramics의 골이식 대체재로서의 기본특성에 대한 비교연구)

  • Park, Kwang-Bum;Park, Jin-Woo;Ahn, Hyun-Uk;Yang, Dong-Jun;Choi, Seok-Kyu;Jang, II-Sung;Yeo, Shin-Il;Suh, Jo-Young
    • Journal of Periodontal and Implant Science
    • /
    • v.36 no.4
    • /
    • pp.797-808
    • /
    • 2006
  • Objective : The purpose of this study was to evaluate the physicochemical properties and cytocompatibility of microporous, spherical biphasic calcium phosphate(BCP) ceramics with a 60/40 $hydroxyapatite/{\beta}$ -tricalcium phosphate weight ratio for application as a bone graft substitute. Materials and Methods : Microporous, spherical BCP granules(MGSB) were prepared and their basic characteristics were compared with commercially available BCP(MBCP; Biomatlante, France) and deproteinized bovine bone mineral(Bio-Oss; GBistlich-Pharma, Switzerland, BBP; Oscotec. Korea), Their physicochemical properties were evaluated by scanning electron microscopy, X-ray diffractometry, Fourier-transform infrared spectroscopy, inductively coupled plasma atomic emission spectrometer, and Brunauer-Emmett-Teller method. Cell viability and proliferation of MC3T3-El cells on different graft materials were evaluated. Results : MGSB granules showed a chemical composition and crystallinity similar with those in MBCP, they showed surface structure characteristic of three dimensionally, well-interconnected micropores. The results of MTT assay showed increases in cell viablity with increasing incubation times. At 4d of incubation, MGSB, MBCP and BBP showed similar values in optical density, but Bio-Oss exhibited significantly lower optical density compared to other bone substitutes(p <0,05). MGSB showed significantly greater cell number compared to other bone substitutes at 3, 5, and 7d of incubation(p <0,05), which were similar with those in polystyrene culture plates. Conclusion: These results indicated the suitable physicochemical properties of MGSB granules for application as an effective bone graft substitute. which provided compatible environment for osteoblast cell growth. However, further detailed studies are needed to confirm its biological effects on bone formation in vivo.

Biological assessment of a new ready-to-use hydraulic sealer

  • Francine Benetti ;Joao Eduardo Gomes-Filho ;India Olinta de Azevedo-Queiroz;Marina Carminatti;Leticia Citelli Conti;Alexandre Henrique dos Reis-Prado ;Sandra Helena Penha de Oliveira ;Edilson Ervolino ;Eloi Dezan-Junior ;Luciano Tavares Angelo Cintra
    • Restorative Dentistry and Endodontics
    • /
    • v.46 no.2
    • /
    • pp.21.1-21.12
    • /
    • 2021
  • Objectives: This study compared the cytotoxicity, biocompatibility, and tenascin immunolabeling of a new ready-to-use hydraulic sealer (Bio-C Sealer) with MTA-Fillapex and white MTA-Angelus. Materials and Methods: L929 fibroblasts were cultivated and exposed to undiluted and diluted material extracts. Polyethylene tubes with or without (the control) the materials were implanted into the dorsa of rats. At 7 days and 30 days, the rats were euthanized, and the specimens were prepared for analysis; inflammation and immunolabeling were measured, and statistical analysis was performed (p < 0.05). Results: MTA-Fillapex exhibited greater cytotoxicity than the other materials at all time points (p < 0.05). The undiluted Bio-C Sealer exhibited greater cytocompatibility at 6 and 48 hours than white MTA-Angelus, with higher cell viability than in the control (p < 0.05). White MTA-Angelus displayed higher cell viability than the control at 24 hours, and the one-half dilution displayed similar results at both 6 and 48 hours (p < 0.05). At 7 days and 30 days, the groups exhibited moderate inflammation with thick fibrous capsules and mild inflammation with thin fibrous capsules, respectively (p > 0.05). At 7 days, moderate to strong immunolabeling was observed (p > 0.05). After 30 days, the control and MTA-Fillapex groups exhibited strong immunolabeling, the white MTA-Angelus group exhibited moderate immunolabeling (p > 0.05), and the Bio-C Sealer group exhibited low-to-moderate immunolabeling, differing significantly from the control (p < 0.05). Conclusions: Bio-C Sealer and white MTA-Angelus exhibited greater cytocompatibility than MTA-Fillapex; all materials displayed adequate biocompatibility and induced tenascin immunolabeling.