• Title/Summary/Keyword: Cyclone

Search Result 592, Processing Time 0.023 seconds

Modeling of Solid Circulation in a Fluidized-Bed Dry Absorption and Regeneration System for CO2 Removal from Flue Gas (연소기체로부터 CO2 회수를 위한 건식 유동층 흡수-재생 공정의 고체순환 모사)

  • Choi, Jeong-Hoo;Park, Ji-Yong;Yi, Chang-Keun;Jo, Sung-Ho;Son, Jae-Ek;Ryu, Chong Kul;Kim, Sang-Done
    • Korean Chemical Engineering Research
    • /
    • v.43 no.2
    • /
    • pp.286-293
    • /
    • 2005
  • An interpretation on the solid circulation characteristics in a fluidized-bed process has been carried out as a first step to simulate the dry entrained-bed absorption and bubbling-bed regeneration system for $CO_2$ removal from flue gas. A particle population balance has been developed to determine the solid flow rates and particle size distributions in the process. Effects of principal process parameters have been discussed in a laboratory scale process (absorption column: 25 mm i.d., 6 m in height; regeneration column: 0.1 m i.d., 1.2 m in height). The particle size distributions in absorption and regeneration columns were nearly the same. As gas velocity or static bed height in the absorption column increased, soild circulation rate and feed rate of fresh sorbent increased, however, mean particle diameter decreased in the absorption column. As cut diameter of the cyclone of the absorption column increased, solid circulation rate decreased, whereas feed rate of fresh sorbent and mean particle diameter in the absorption column increased. As attrition coefficient of sorbent particle increased, solid circulation rate and feed rate of fresh sorbent increased but mean particle diameter in the absorption column decreased.

Estimation and Assessment of Future Design Rainfall from Non-stationary Rainfall Frequency Analysis using Separation Method (호우분리기법을 적용한 비정상성 빈도해석의 미래확률강우량 산정 및 평가)

  • Son, Chan-Young;Lee, Bo-Ram;Choi, Ji-Hyeok;Moon, Young-Il
    • Journal of Korea Water Resources Association
    • /
    • v.48 no.6
    • /
    • pp.451-461
    • /
    • 2015
  • This study aimed to estimate the future design rainfall through a non-stationary frequency analysis using the rainfall separation technique. First, we classified rainfall in the Korean Peninsula into local downpour and TC-induced rainfall through rainfall separation technique based on the path and size of a typhoon. Furthermore, we performed the analysis of regional rainfall characteristics and trends. In addition, we estimated the future design rainfall through a non-stationary frequency analysis using Gumbel distribution and carried out its quantitative comparison and evaluation. The results of the analysis suggest that the increase and decrease rate of rainfall in the Korean Peninsula were different and the increasing and decreasing tendencies were mutually contradictory at some points. In addition, a non-stationary frequency analysis was carried out by using the rainfall separation technique. The outcome of this analysis suggests that a relatively reasonable future design rainfall can be estimated. Comparing total rainfall with the future design rainfall, differences were found in the southern and eastern regions of the Korean peninsula. This means that climate change may have a different effect on the typhoon and local downpour. Thus, in the future, individual assessment of climate change impacts needs to be done through moisture separation. The results presented here are applicable in future hydraulic structures design, flood control measures related to climate change, and policy establishment.

Characterization of Heavy Metals Including Mercury and Fine Particulate Emitted from a Circulating Fluidized Bed Power Plant Firing Anthracite Coals (무연탄 순환유동층 발전소로부터 배출되는 수은을 포함한 중금속 및 미세분진의 배출 특성)

  • Kim, Jeong-Hun;Yoo, Jong-Ik;Seo, Yong-Chil
    • Korean Chemical Engineering Research
    • /
    • v.48 no.2
    • /
    • pp.268-274
    • /
    • 2010
  • Emission of heavy metals as hazardous air pollutants has been focused with tightening regulatory limits due to their hazardousness. Measurements and characteristic investigations of heavy metals emitted from a commercial power plant burning anthracite coal have been carried out. The plant consists of a circulating fluidized bed combustor, a cyclone, a boiler and an electrostatic precipitator(ESP) in series. Dust and gaseous samples were collected to measure main heavy metals including gaseous mercury before ESP and at stack. Dust emissions as total particulate matter (TPM), PM-10 and PM-2.5 at inlet of ESP were very high with 23,274, 9,555 and $7,790mg/Sm^3$, respectively, as expected, which is much higher than those from pulverized coal power plants. However TPM at stack was less than $0.16mg/Sm^3$, due to high dust removal efficiency by ESP. Similarly heavy metals emission showed high collection efficiency across ESP. From particle size distribution and metal enrichment in sizes, several metal concentrations could be correlated with particle size showing more enrichment in smaller particles. Mercury unlike other solid metals behaved differently by emitting as gaseous state due to high volatility. Removal of mercury was quite less than other metals due to it's volatility, which was 68% only. Across ESP, speciation change of mercury from elemental to oxidized was clearly shown so that elemental mercury was half of total mercury at stack unlike other coal power plants which equipped wet a scrubber.

Air Drying Technology for Dewatered Cake from Wastewater and Waterworks Sludge (상.하수 슬러지 탈수케이크의 공기건조에 관한 연구)

  • Lee, Jung-Eun;Cho, Eun-Man;Kim, Bong-Hwan
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.11
    • /
    • pp.1154-1161
    • /
    • 2006
  • Air drying equipment was built as a device for reduction of dewatered cake from wastewater and waterworks sludge and to reproduce it by reusable matter. Dewatered cake was supplied into the air drying equipment which operated by air velocity of 80 m/sec, air rate 30 $m^3/min$ and air temperature of $40^{\circ}C$, and dried to produce the dried powder. The air drying equipment was composed of the air ejector which made high-speed fluid field, and cyclone which made circling fluid field. Dewatered cake was crushed at the high-speed zone as first step, and formed into dried powder of sphere shape by the collision between particles at the circling fluid zone.. Wastewater sludge with water content of 82.5 wt% was supplied 1.0 kg/min into air drying equipment and produced the dried powder which had the water content of 62.3 wt% and mass median diameter of 2.4 mm after process. At that time, it was analyzed that water removal rate was 0.1 $H_2O{\Delta}kg/min{\cdot}DS$ kg and air consumption was 170 $m^3/DS$ kg. Under same experimental conditions, when waterworks sludge was dried, water content of dried powder decrease to 47.5 wt% and mass median diameter decrease 2.1 mm and water removal rate increase 0.13 $H_2O{\Delta}kg/min{\cdot}DS$ kg. Air consumption increase 180 $m^3/DS$ kg with comparison to the results of wastewater sludge. Therefore, this technology was evaluated that drying the dewatered cake of waterworks sludge was more efficient than wastewater sludge, and also economical sludge handling technology due to drying the cake by only air.

The Spatial Distribution of Snowfall and its Development Mechanism over the Honam Area (호남 지방의 국지적 강설 분포와 그 차이의 원인에 관한 연구)

  • Lee Seung-Ho;Lee Kyoung-Mi
    • Journal of the Korean Geographical Society
    • /
    • v.41 no.4 s.115
    • /
    • pp.457-469
    • /
    • 2006
  • This study aims to understand the characteristics of spatial distribution of snowfall and to analyze its development mechanism in Honam province in Korea. The areas of snowfall in Honan area can be divided into the seven sub-area by snowfall pattern. In the west coastal area of heavy snowfall and the southwest coastal area of heavy snowfall, snowfall develops over reason of ocean by Siberian High while in the northern inland area of heavy snowfall and the southern inland area of heavy snowfall, it develops when a strong Siberian High affects to inland. Then, much snowfall is by a forced ascending due to topography in Namwon, Imsil and Gwangju of the northwestward of the Noryung and Sobaek mountain ranges while it is weak in Jeonju and Suncheon of the low plains and the southeastward. In the mountainous area of heavy snowfall and the south coastal area of light snowfall, cyclone is also one of causes of snowfall. In the southwest coastal area, snowfall is meager than the southwest coastal area of heavy snowfall because this area is far from the west coast. It is confirmed that the snowfall difference of the coast, inland and mountainous area appears by temperature difference of sea surface and 850hPa temperature, wind speed of Siberian High.

Anthracite Oxygen Combustion Simulation in 0.1MWth Circulating Fluidized Bed (0.1 MWth 급 순환유동층에서의 무연탄 연소 전산유체역학 모사)

  • Go, Eun Sol;Kook, Jin Woo;Seo, Kwang Won;Seo, Su Been;Kim, Hyung Woo;Kang, Seo Yeong;Lee, See Hoon
    • Korean Chemical Engineering Research
    • /
    • v.59 no.3
    • /
    • pp.417-428
    • /
    • 2021
  • The combustion characteristics of anthracite, which follow a complex process with low reactivity, must be considered through the dynamic behavior of circulating fluidized bed (CFB) boilers. In this study, computational fluid dynamics (CFD) simulation was performed to analyze the combustion characteristics of anthracite in a pilot scale 0.1 MWth Oxy-fuel circulating fluidized bed (Oxy-CFB) boiler. The 0.1MWth Oxy-CFB boiler is composed of combustor (0.15 m l.D., 10 m High), cyclone, return leg, and so on. To perform CFD analysis, a 3D simulation model reactor was designed and used. The anthracite used in the experiment has an average particle size of 1,070 ㎛ and a density of 2,326 kg/m3. The flow pattern of gas-solids inside the reactor according to the change of combustion environment from air combustion to oxygen combustion was investigated. At this time, it was found that the temperature distribution in air combustion and oxygen combustion showed a similar pattern, but the pressure distribution was lower in oxygen combustion. addition, since it has a higher CO2 concentration in oxygen combustion than in air combustion, it can be expected that carbon dioxide capture will take place actively. As a result, it was confirmed that this study can contribute to the optimized design and operation of a circulating fluidized bed reactor using anthracite.

The Numerical Study on Effect of the Droplet Sizes on Internal Mass Transfer in the Spray Type Scrubber (분무형 스크러버에 내에서 액적크기에 따른 물질전달에 관한 전산해석적 연구)

  • Lee, Chanhyun;Chang, Hyuksang
    • Clean Technology
    • /
    • v.25 no.1
    • /
    • pp.19-32
    • /
    • 2019
  • As regional air pollution gets worse by the sulfur oxides emitted from various types of vessels passing through the many countries, the International Maritime Organization establishes the emission control areas and regulates sulfur dioxide in those areas. In order to satisfy these regional regulations, the fuel selection method and the exhaust gas post-treatment device are applied to the ships. Due to the economic reasons, the post-treatment method of exhaust gas for reducing the amount of sulfur oxides discharged is mainly preferred. The scrubber which is dominantly used in the ships are the spray type system where the sprayed liquid drops used for capturing the soluble sulfur dioxides in the exhaust gas. The performance of the spray type system depends on the size distribution of the sprayed droplets. In order to evaluate this performance, we designed counterflow type scrubber and cyclone scrubber and evaluated the desulfurization efficiency and the amount of droplet evaporation according to the size of each droplet by using computational fluid dynamics. The Eulerian-Eulerian analysis method was used because the scrubber had a gas-liquid two-phase flow inside the scrubber. When the diameter of the droplet was $100{\mu}m$, $300{\mu}m$, $500{\mu}m$ and $700{\mu}m$. As a result, both of scrubbers showed high desulfurization efficiency and low evaporation amount at $500{\mu}m$ and $700{\mu}m$.

Analysis of the Characteristics and High Concentrations of Carbon Dioxide Measured at the Gosan Site in Jeju, Korea in 2007 (2007년 제주 고산의 이산화탄소 농도 현황 및 고농도 사례 분석)

  • Kim, Seung-Yeon;Lee, Jae-Bum;Yu, Jeong-Ah;Hong, Yu-Deog;Song, Chang-Geun
    • Journal of Climate Change Research
    • /
    • v.2 no.1
    • /
    • pp.1-14
    • /
    • 2011
  • In order to identify the current state of the $CO_2$ concentrations at the Gosan site in Jeju, the data from the Gosan station was compared with the ones from domestic and foreign sites registered in the World Data Centre for Greenhouse Gases(WDCGG). As a result, the $CO_2$ concentrations in the Asian region including Gosan site were higher than in the other continents, which can be explained that the $CO_2$ emissions in the Asian region have been rapidly increasing due to the recent economic growth. In comparison with ther Asian-Pacific sites (i.e., Ryori, Waliguan, and Mauna Loa), Gosan site showed the highest $CO_2$ concentrations because this site can be easily affected by China emissions. With the trajectory analysis and the ratios of air pollutants, we found that the high concentrations of Gosan site in January were mainly caused by the long-range transport from China, while in August the high concentration in the night time by the stagnation and the active plant respiration. Also, in May and November it occurred as the polluted air from China was transported with migratory cyclone.

Analysis of the Fine Particulate Matter Particle Size Fraction Emitted from Facilities Using Solid Refuse Fuel (고형연료제품 사용시설에서 배출되는 미세먼지 입경분율 분석)

  • You, Han-Jo;Jung, Yeon-Hoon;Kim, Jin-guil;Shin, Hyung-Soon;Lim, Yoon-Jung;Lee, Sang-Soo;Son, Hae-Jun;Lim, Sam-Hwa;Kim, Jong-Su
    • Journal of Environmental Health Sciences
    • /
    • v.46 no.6
    • /
    • pp.719-725
    • /
    • 2020
  • Objectives: With the growth of national interest in fine particulate matter, many complaints about pollutants emitted from air pollution emitting facilities have arisen in recent years. In particular, it is thought that a large volume of particulate pollutants are discharged from workplaces that use Solid Refuse Fuel (SRF). Therefore, particulate contaminants generated from SRF were measured and analyzed in this study in terms of respective particle sizes. Methods: In this study, particulate matter in exhaust gas was measured by applying US EPA method 201a using a cyclone. This method measures Filterable Particulate Matter (FPM), and does not consider the Condensable Particulate Matter (CPM) that forms particles in the atmosphere after being discharged as a gas in the exhaust gas. Results: The mass concentration of Total Suspended Particles (TSP) in the four SRF-using facilities was 1.16 to 11.21 mg/Sm3, indicating a very large concentration deviation of about 10 times. When the fuel input method was the continuous injection type, particulate matter larger than 10 ㎛ diameter showed the highest particle size fraction, followed by particulate matter smaller than 10 ㎛ and larger than 2.5 ㎛, and particulate matter of 2.5 ㎛ or less. Contrary to the continuous injection type, the batch injection type had the smallest particle size fraction of particulate matter larger than 10 ㎛. The overall particulate matter decreased as the operating load factor decreased from 100% to 60% at the batch input type D plant. In addition, as incomplete combustion significantly decreased, the particle size fraction also changed significantly. Both TSP and heavy metals (six items) satisfied the emissions standards. The measured value of the emission factor was 38-99% smaller than the existing emissions factor. Conclusions: In the batch injection facility, the particulate matter decreased as the operating load factor decreased, as did the particle size fraction of the particulate matter. These results will help the selection of effective methods such as reducing the operating load factor instead of adjusting the operating time during emergency reduction measures.

Emission Characteristics and Coefficients of Air Pollutants in Iron and Steel Manufacturing Facilities (제철제강시설의 대기오염물질 배출특성 및 배출계수 산정)

  • Kim, Byoung-Ug;Hong, Young-Kyun;Lee, Yeong-Seob;Yang, Seung-Pyo;Hyun, Geun-Woo;Yi, Geon-Ho
    • Journal of Environmental Health Sciences
    • /
    • v.47 no.3
    • /
    • pp.259-266
    • /
    • 2021
  • Objectives: This study was conducted to identify the emissions characteristics of total particulate matter (TPM), fine dust (PM10, PM2.5), and gaseous pollutants (SOx, NOx) in iron and steel manufacturing facilities in order to investigate emissions factors suitable for domestic conditions. Methods: Total particulate matter (TPM), fine dust (PM10, PM2.5), and gas phase materials were investigated at the outlet of electric arc furnace facilities using a cyclone sampling machine and a gas analyzer. Results: The concentrations of TPM ranged from 1.64 to 3.14 mg/Sm3 and the average was 2.47 mg/Sm3. Particulate matter 10 (PM10) averaged 1.49 mg/Sm3 with a range of 0.92 to 1.99 mg/Sm3, and the resulting ratio of PM10 to TPM was around 60 percent. PM2.5/PM10 ranged from 33.7 to 47.9% and averaged 41.6%. Sulfur oxides (SOx) were not detected, and nitrogen oxides (NOx) averaged 6.8 ppm in the range of 5.50 to 8.67 ppm. TPM emission coefficients per product output were in the range of 0.60 to 1.26 g/kg, 0.13 to 0.79 g/kg for PM10 and 0.12 to 0.36 g/kg for PM2.5, and showed many differences from the emissions coefficients previously announced. An emissions coefficient for NOx is not currently included in the domestic notices, but the results were calculated to be 0.42 g/kg per product output. Conclusions: Investigation and research on emissions coefficients that can reflect the characteristics of various facilities in Korea should be conducted continuously, and the determination and application of unique emissions coefficients that are more suitable for domestic conditions are needed.