Rotation capacity of composite beam connected to RHS column, experimental test results

  • Eslami, Mohammadreza;Namba, Hisashi
    • Steel and Composite Structures
    • /
    • 제22권1호
    • /
    • pp.141-159
    • /
    • 2016
  • Commonly in steel frames, steel beam and concrete slab are connected together by shear keys to work as a unit member which is called composite beam. When a composite beam is subjected to positive bending, flexural strength and stiffness of the beam can be increased due to "composite action". At the same time despite these advantages, composite action increases the strain at the beam bottom flange and it might affect beam plastic rotation capacity. This paper presents results of study on the rotation capacity of composite beam connected to Rectangular Hollow Section (RHS) column in the steel moment resisting frame buildings. Due to out-of-plane deformation of column flange, moment transfer efficiency of web connection is reduced and this results in reduction of beam plastic rotation capacity. In order to investigate the effects of width-to-thickness ratio (B/t) of RHS column on the rotation capacity of composite beam, cyclic loading tests were conducted on three full scale beam-to-column subassemblies. Detailed study on the different steel beam damages and concrete slab damages are presented. Experimental data showed the importance of this parameter of RHS column on the seismic behavior of composite beams. It is found that occurrence of severe concrete bearing crush at the face of RHS column of specimen with smaller width-to-thickness ratio resulted in considerable reduction on the rate of strain increase in the bottom flange. This behavior resulted in considerable improvement of rotation capacity of this specimen compared with composite and even bare steel beam connected to the RHS column with larger width-to-thickness ratio.

반복하중을 받는 프리캐스트 콘크리트 건식 보-기둥 연결부의 거동분석 (Analysis on the Behaviors of Precast Concrete Beam-Column Connections Subject to Cyclic Loading)

  • 송형수;유승룡
    • 콘크리트학회논문집
    • /
    • 제18권4호
    • /
    • pp.497-506
    • /
    • 2006
  • 본 연구에서는 주상복합건물에 적용가능한 건식공법에 의한 프리캐스트 콘크리트 보-기둥 연결부에 대하여 실험을 통하여 분석하였다. 현재 국내에 활용하고 있는 프리캐스트 콘크리트 보-기둥 연결부와 현재 미국에서 사용되고 있는 DDC 연결부, 그리고 DDC 연결부와 개선된 연결부에 포스트텐션을 도입한 시험체를 제작하였고, 실험을 통하여 그 거동을 평가하였다. 실험 결과 보-기둥 연결부에 DDC 시스템을 적용하게 되면 연결부의 강도와 연성능력의 향상을 기대할 수 있었으나 파괴 메커니즘이 보에 에너지를 분산시키지 않고, 연결부에서 사인장 균열에 의하여 에너지를 소산시키게 되어 연결부가 파괴되는 단점이 나타났다. 개량 DDC 연결부는 기둥에 사인장균열이 발생하지 않고 보다 연성적인 파괴거동을 보여주었다. 또한 보-기둥 연결부에 포스트텐션의 도입은 연결부 강도의 증가는 크게 기대할 수 없었으나 자가조정(self-centering) 등을 통하여 연결부의 안정성 및 연성능력에 기여하는 것으로 나타났다.

반복하중을 받는 콘크리트충전 각형강관 보-기둥의 거동 (Behavior of Concrete-Filled Square Tubular Beam-Column under Cyclic Load)

  • 강창훈;문태섭
    • 한국강구조학회 논문집
    • /
    • 제12권4호통권47호
    • /
    • pp.387-395
    • /
    • 2000
  • 본 연구는 콘크리트충전 각형강관(CFT) 기둥의 강도와 변형능력의 평가 및 내진성능에 대한 기초 자료의 제시를 목적으로 한다. 실험체는 초고층 건물의 최하단기둥의 응력분포를 가정하여 켄틸레버형 기둥으로 하고, 총 18개의 실험체가 일정 축력과 반복 횡하중 하에서 실험되었다. 본 실험에 적용된 주요변수는 강관의 폭/두께 비, 세장비 (LO/D), 그리고 축력비이다. 각 변수가 기둥의 강도, 변형능력, 그리고 에너지 흡수능력에 미치는 영향이 기술되었고, 각국 규준식과 실험결과를 비교하였다. 분석결과, 피복형 한국강구조학회 규준은 합성 단면적과 탄성계수를 AIJ와 AISC-LRFD 수준으로 수정한다면, 충전형에도 적용가능 할 것으로 판단된다. 마지막으로, 구속효과를 고려하여 단면의 소성해석을 통하여 구한 B. Kato의 CFT 기둥의 휨내력 제안식은 실험결과와 좋은 대응을 나타내고 있다.

  • PDF

기존 비보강 조적조 건축물의 내진 및 에너지 동시보강패널 정적반복가력실험 (Static Cyclic Loading Test of the Seismic and Energy Simultaneous Retrofit Panel for Existing Unreinforced Masonry Buildings)

  • 최형욱;이상호;최형석;김태형;백은림
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제24권4호
    • /
    • pp.81-90
    • /
    • 2020
  • 기존 비보강 조적벽체의 내진 성능과 에너지 효율을 동시에 보강하기 위한 TCP 보강 공법을 개발하였다. TCP는 경량 모르타르 내 격자형 탄소섬유 시트와 모세관 튜브를 매립하여 일체로 타설한 패널로 조적벽체에 부착하여 탄소섬유 시트에 의한 내진보강과 모세관 튜브에 온수를 공급함으로써난방 또는 단열 등의 에너지 보강을 동시에 달성할수 있는 보강 공법이다. 본 연구에서는 TCP의 내진 보강 효과를 파악하기 위하여 TCP 보강 유무에 따른 조적 벽체를 대상으로 정적가력실험을 실시하였다. 실험 결과, TCP 보강에 의해 최대 강도 및 변위가 약 1.4배증가하였으며, 초기 강성과 에너지 흡수능력에 효과가 있음을 보였다. 또한, 손상에 따른 조적 벽체의 변형이 제어됨에 따라 취성 파괴를 예방할수 있을 것으로 판단된다.

Health monitoring of a new hysteretic damper subjected to earthquakes on a shaking table

  • Romo, L.;Benavent-Climent, A.;Morillas, L.;Escolano, D.;Gallego, A.
    • Earthquakes and Structures
    • /
    • 제8권3호
    • /
    • pp.485-509
    • /
    • 2015
  • This paper presents the experimental results obtained by applying frequency-domain structural health monitoring techniques to assess the damage suffered on a special type of damper called Web Plastifying Damper (WPD). The WPD is a hysteretic type energy dissipator recently developed for the passive control of structures subjected to earthquakes. It consists of several I-section steel segments connected in parallel. The energy is dissipated through plastic deformations of the web of the I-sections, which constitute the dissipative parts of the damper. WPDs were subjected to successive histories of dynamically-imposed cyclic deformations of increasing magnitude with the shaking table of the University of Granada. To assess the damage to the web of the I-section steel segments after each history of loading, a new damage index called Area Index of Damage (AID) was obtained from simple vibration tests. The vibration signals were acquired by means of piezoelectric sensors attached on the I-sections, and non-parametric statistical methods were applied to calculate AID in terms of changes in frequency response functions. The damage index AID was correlated with another energy-based damage index -ID- which past research has proven to accurately characterize the level of mechanical damage. The ID is rooted in the decomposition of the load-displacement curve experienced by the damper into the so-called skeleton and Bauschinger parts. ID predicts the level of damage and the proximity to failure of the damper accurately, but it requires costly instrumentation. The experiments reported in this paper demonstrate a good correlation between AID and ID in a realistic seismic loading scenario consisting of dynamically applied arbitrary cyclic loads. Based on this correlation, it is possible to estimate ID indirectly from the AID, which calls for much simpler and less expensive instrumentation.

그루브 조인트가 설치된 수계소화설비 입상배관계통의 지진거동분석을 위한 실험적 연구 (Experimental Study for Seismic Behavior Analysis of a Fire Protection Riser Pipe System with Groove Joints)

  • 김성완;윤다운;김재봉;전법규
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제25권2호
    • /
    • pp.35-42
    • /
    • 2021
  • 본 연구에서는 NFPA 13을 참조하여 구조물 2층을 구현한 강재지그를 제작하였으며, 그루브 조인트의 배관연결재가 적용된 배관계통을 구성하고 정적 반복가력에 의한 지진모사실험을 수행하였다. 지진모사실험은 엑츄에이터로 건축물 내진설계기준의 최대허용 층간변위에 대한 반복가력실험을 수행하였다. 지진하중 발생 시 입상배관의 구조물에 대한 변형 또는 구조부재간의 상대변위에 의한 변위지배적인 거동에 따른 배관계통과 주요 배관요소의 지진거동을 분석하였다. 배관계통의 변형각은 기존의 센서를 이용하여 측정하기가 어려우므로 이미지측정시스템을 적용하였다.

원형토조 시험을 통한 반복하중에 따른 부직포의 침하특성 (Characteristics of Settlement for Non-woven Geotextile through Cyclic Loading Model Test)

  • 최찬용;이진욱;김헌기
    • 한국지반신소재학회논문집
    • /
    • 제8권2호
    • /
    • pp.47-54
    • /
    • 2009
  • 국내 대부분을 차지하고 있는 자갈 도상궤도는 지속적인 열차반복하중에 의해 마모, 노반으로 관입, 노반표면의 불균질 등에 의해 도상자갈의 기능을 상실하게 된다. 이러한 현상이 지속적으로 발생하면 설계 당초 주요 기능이었던 배수기능을 충분히 발휘하지 못하기 때문에 강우가 노반에 체류되고 물로 인해 간극수압이 증가하여 전단강도가 저하되어 점진적으로 노반이 연약화된다. 이 논문에서는 원형모형실험을 이용하여 부직포 3종류에 대하여 0일, 3일, 7일 체수조건으로 하여 반복하중을 재하시킴으로써 부직포의 침하특성과 지지력 변화를 관찰하였다. 실험결과 0일 체수조건에서 토목섬유 보강과 무보강에 따라 최종 변위는 약 1% 차이가 있으며, 지반의 포화도가 증가함에 따라 침하량이 커지는 경향이 있었다. 보강재의 중량이 클수록 소성침하량이 작게 평가되었으며, 임계 함수비를 초과한 경우에는 부직포의 인장강도와 중량에 따라 침하량의 차이가 발생하였다. 또한 무보강과 비교해 볼 때 부직포에 의한 토압 저감효과는 있으나, 부직포의 중량에 의한 토압저감 효과는 영향이 미미한 것으로 평가되었다.

  • PDF

강합성교각의 내진성능평가 Part I : 준정적 반복재하실험 (Seismic Performance of Concrete-Filled Steel Piers Part I : Quasi-Static Cyclic Loading Test)

  • 조창빈;서진환;장승필
    • 한국지진공학회논문집
    • /
    • 제6권2호
    • /
    • pp.9-19
    • /
    • 2002
  • 강합성교각과 강교각은 철근곤크리트교각에 비해서 우수한 연성, 작은 단면 및 빠른 시공속도에도 불구하고 이 같은 장점들을 활용할 필요가 있는 도시지역에서조차 철근콘크리트교각의 대안으로서 활용되지 못하였다. 이 논문은 강합성교각과 강교각의 내진성능 평가에 관한 연속된 두편의 논문 중 첫편으로 강교각과 강합성 교각의 연성과 강성을 평가 비교하기 위해 수행한 준정적 반복재하실험을 대상으로 하였다. 기존의 강교각 및 강합성교각의 실험과 더불어 채움콘크리트와 하부 다이어프램간의 부작을 개선한 상세를 실험하였다. 또한, 강합성교각의 연성과 강성을 산정하기 위한 간편한 수치해석방법을 찾기 위해 비선형 스프링과 쉘요소를 사용한 해석을 시도하였다. 도시내의 전형적인 오버패스구간의 교각을 모델로 한 실험결과, 강합성교각은 강교각에 비해서 우수한 강성과 에너지 소산능력을 가지고 있는 것으로 나타났으며 채움콘크리트의 부착과 응력집중부의 상세를 개선시기는 것이 강합성교각의 연성과 강성을 증가시키는데 효과적인 것으로 나타났다. 시도된 수지해석방법은 강합성교각과 강교각의 거동을 완벽하게 모사하지는 못했지만 추가적인 연구가 진행되면 연성과 강성을 평가하는 간편한 방법으로 사용될 수 있는 것으로 판단된다.

Effects of air-abrasion pressure on the resin bond strength to zirconia: a combined cyclic loading and thermocycling aging study

  • Al-Shehri, Eman Z.;Al-Zain, Afnan O.;Sabrah, Alaa H.;Al-Angari, Sarah S.;Dehailan, Laila Al;Eckert, George J.;Ozcan, Mutlu;Platt, Jeffrey A.;Bottino, Marco C.
    • Restorative Dentistry and Endodontics
    • /
    • 제42권3호
    • /
    • pp.206-215
    • /
    • 2017
  • Objectives: To determine the combined effect of fatigue cyclic loading and thermocycling (CLTC) on the shear bond strength (SBS) of a resin cement to zirconia surfaces that were previously air-abraded with aluminum oxide ($Al_2O_3$) particles at different pressures. Materials and Methods: Seventy-two cuboid zirconia specimens were prepared and randomly assigned to 3 groups according to the air-abrasion pressures (1, 2, and 2.8 bar), and each group was further divided into 2 groups depending on aging parameters (n = 12). Panavia F 2.0 was placed on pre-conditioned zirconia surfaces, and SBS testing was performed either after 24 hours or 10,000 fatigue cycles (cyclic loading) and 5,000 thermocycles. Non-contact profilometry was used to measure surface roughness. Failure modes were evaluated under optical and scanning electron microscopy. The data were analyzed using 2-way analysis of variance and ${\chi}^2$ tests (${\alpha}=0.05$). Results: The 2.8 bar group showed significantly higher surface roughness compared to the 1 bar group (p < 0.05). The interaction between pressure and time/cycling was not significant on SBS, and pressure did not have a significant effect either. SBS was significantly higher (p = 0.006) for 24 hours storage compared to CLTC. The 2 bar-CLTC group presented significantly higher percentage of pre-test failure during fatigue compared to the other groups. Mixed-failure mode was more frequent than adhesive failure. Conclusions: CLTC significantly decreased the SBS values regardless of the air-abrasion pressure used.

모래지반에서 횡방향 반복하중을 받는 말뚝의 영구수평변위 평가 (Evaluation of Permanent Lateral Displacement of a Cyclic Laterally Loaded Pile in Sandy Soil)

  • 백성하;김준영;이승환;정충기
    • 한국지반공학회논문집
    • /
    • 제33권2호
    • /
    • pp.17-26
    • /
    • 2017
  • 해상구조물, 송전탑 등을 지지하는 말뚝기초는 바람, 조류, 파랑 등의 영향으로 횡방향 반복하중을 지배적으로 받으며, 이는 말뚝 주변 지반에 영구수평변위를 발생시켜 구조물의 안정성 및 기능성을 저해한다. 본 연구에서는 횡방향 반복하중에 의해 발생하는 말뚝의 영구수평변위를 평가하기 위하여, 서로 다른 세 가지 상대밀도(40%, 70%, 90%)로 조성된 건조 및 포화 모래지반에서 모형말뚝시험을 수행하였다. 모형시험 결과, 모든 시험조건에서 말뚝에 재하 된 횡방향 반복하중은 말뚝 주변 지반에 영구수평변위를 발생시켰다. 누적된 영구수평변위의 크기는 말뚝에 재하되는 횡방향 반복하중의 크기 및 재하횟수가 증가함에 따라 증가하였지만, 1회 재하로 인하여 발생되는 영구수평변위의 증가량은 점차 감소하였다. 또한, 말뚝에 발생하는 영구수평변위는 지반의 상대밀도가 클수록 작게 발생하고, 지반이 포화되면 크게 발생되는 것으로 평가되었다. 추가적으로, 누적 영구수평변위를 최초 재하 시 발생한 영구수평변위로 정규화한 영구수평변위를 평가하였으며, 이를 모래지반의 상대밀도, 횡방향 반복하중의 재하횟수에 관한 식으로 나타내었다.