• Title/Summary/Keyword: Cycle to Cycle Variation

Search Result 737, Processing Time 0.031 seconds

Change of Voice during Menstrual Cycle (월경 주기가 여성의 목소리에 미치는 영향)

  • Lee, Ja-Hyun;Park, Eun-Hee;Chung, Sung-Min;Kim, Han-Su
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.19 no.2
    • /
    • pp.113-116
    • /
    • 2008
  • Baekgroud and Objectives: The study was purposed to evaluate the relationship between the voice change and the menstrual cycle by measuring the variation of subjective and objective parameters. Materials and Methods: Prospective study of 13 healthy women during 2 mentrual cycles. Their voices were recorded at follicular phase and then luteal phase of the menstrual cycle. We used both single vowel /a/ and sentences for evaluate acoustic parameters. Aerodynamic parameters were also evaluated. Voice handicap index (VHI), and the presence of premenstrual syndromes (PMS) were checked at each period. We used Wilcoxon's signed rank test to compare the parameters of two periods. Results: VHI were 5.1 at both periods (p=0.146) and 92.3% of women were diagnosable with PMS. There were no significant differences in acoustic parameters and aerodynamic parameters between the two periods. Conclusion: This study shows that not only the subjective but also the objective changes of the voice parameters did not exist during the menstrual cycle in women.

  • PDF

Investigation on Adhesive Properties depending on the Environmental Variation of the Steel Plate Adhesive Strengthening Method by the Epoxy Resin (에폭시 수지 접착 강판보강공법의 환경 변화에 따른 부착 특성 검토)

  • Han, Cheon-Goo;Byun, Hang-Yong;Park, Yong-Kyu
    • Journal of the Korea Institute of Building Construction
    • /
    • v.7 no.3
    • /
    • pp.107-113
    • /
    • 2007
  • This study is to investigate adhesive properties depending on the temperature, humidity, and freeze-thraw of the Steel plate adhesive strengthening method by the epoxy resin. The results are summarized as following. For the temperature variation, the debonding failure appear only after 1 cycle of temperature varoation because the coefficient of thermal expansion of the epoxy resin is comparatively large, and the bonding strength is decreased. The deformation properties and ultrasonic pulse velocity on each materials are similar until 4 cycles on the dry and moisture test. As the freeze-thraw test, the epoxy resin is degraded easily subjected to freeze-thaw cycle, comparatively easy, so the debonding failure may occur in short term because of the freeze-thaw repeatition.p

A study on the measurement and characterization of tubulent flow inside an engine cylinder (엔진 실린더내 난류유동 측정과 정량화방법에 관한 연구)

  • 강건용;엄종호;김용선
    • Journal of the korean Society of Automotive Engineers
    • /
    • v.14 no.6
    • /
    • pp.39-47
    • /
    • 1992
  • The engine combustion is one of the most important process affecting performance and emissions. One effective way to improve the engine combustion is to control motion of the charge inside a cylinder by means of optimum induction system design, because the flame speed is mainly determined by the turbulence in a gasoline engine. This paper describes the measurement and characterization of mean velocity and turbulence intensity inside the cylinder of a 4-valve gasoline engine using laser Doppler velocimeter(LDV) under motoring(non-firing) conditions. Since the measured LDV data in each cycle show small cycle variation during compression stroke in the tested engine, the mean velocity and turbulence intensity are calculated by ensemble averaging method neglecting cycle variation effects. In the ensemble averaging method, the effects of the calculation window, in which velocities are assumed as the same crank angle, on mean velocity and turbulence intensity are fully investigated. In addition, the effects of measuring point on the flow characteristics are studied. With large calculation window, the mean velocity is shown to be less sensitive with respect to crank angle and turbulence intensity decrease in its absolute amplitude. When the piston approch to the top dead center of compression, the turbulence intensity is found to be homogeneous in the cylinder.

  • PDF

Regression Analysis of Life Cycle Profile for Life Cycle Cost and Bridge Management System (교량관리체계 개선 및 LCC분석을 위한 생애주기 성능이력 회귀함수의 산정)

  • Kong, Jung-Sik;Park, Heung-Min;Lee, Kwan-Kyun;Park, Chang-Ho;Shin, Jae-In
    • Proceedings of the Korean Institute Of Construction Engineering and Management
    • /
    • 2008.11a
    • /
    • pp.149-154
    • /
    • 2008
  • Service life of bridges should be evaluated by physical life considering damage/deterioration. But it is difficult to identify optimal maintenance scenario due to insufficient research related to that. To identify optimal maintenance scenario, it is needed to develope life cycle profile model of condition state variation by deterioration factor. The LCP model has been developed in consideration of regression analysis and survey in this study. It is expected that the LCP model could help to achieve HBMS system improvement.

  • PDF

CHARACTERISTICS OF UNSTEADY PLANAR-SYMMETRIC AND ASYMMETRIC FLOWS OVER A SPHERE (구 주위의 비정상 면대칭 및 비대칭 유동의 특성)

  • Kim, Dong-Joo
    • Journal of computational fluids engineering
    • /
    • v.13 no.4
    • /
    • pp.39-44
    • /
    • 2008
  • Numerical simulations of laminar flow over a sphere are conducted to investigate the effect of the Reynolds number on the characteristics of vortex shedding. The Reynolds numbers considered are between 300 and 475, covering unsteady planar-symmetric and asymmetric flows. Results show that the unsteady planar-symmetric flow can be categorized into two different regimes: single-frequency regime and multiple-frequency regime. The former has a single frequency component due to periodic shedding of the vortices with the same strength in every shedding cycle, while the latter has multiple frequency components due to cycle-to-cycle variation in the strength of shed vortices with the shedding angle fixed. The multiple-frequency planar-symmetric flow, which is newly found in the present study, occurs at Re=330${\sim}$360 between the single-frequency planar-symmetric flow and the asymmetric flow. On the other hand, the asymmetric flow occurs at Re${\geq}$365, where the vortices shed from the sphere show variation both in strength and shedding angle unlike the planar-symmetric flow. Also, it is shown that the breaking of planar symmetry is closely related to the imbalance of vortical strength between a pair of streamwise vortices.

Analysis of 1MW Closed OTEC Cycle Using Thermal Effluent and Waste Heat (발전소 온배수를 이용한 1MW급 폐쇄형 해양온도차발전 성능해석)

  • Kim, Hyeon-Ju;Lee, Ho-Saeng;Jung, Dong-Ho;Moon, Deok-Soo
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.34 no.4
    • /
    • pp.470-476
    • /
    • 2010
  • The thermodynamic performance of closed ocean thermal energy conversion (OTEC) cycle with 1 MW gross power was evaluated to obtain the basic data for the optimal design of OTEC. The basic thermodynamic model for OTEC is Rankine cycle and the thermal effluent from power plant was used for the heat source of evaporator. The cycle performance such as efficiency, heat exchanger capacity, etc. was analyzed on the temperature variation of thermal effluent. The saturated pressure of evaporator increased with respect to the increase of thermal effluent temperature, so the cycle efficiency increased and necessary capacity of evaporator and condenser decreased under 1 MW gross power. As the thermal effluent temperature increases about $15^{\circ}C$, the cycle efficiency increased approximately 44%. So, it was revealed that thermal effluent from power plant is important heat source for OTEC plant. Also, if there is an available waste heat, it can be transferred heat to the working fluid form the evaporator through heat exchanger and cycle efficiency will be increased.

A study on the optimum control of refrigerator with on-off control system (On-off 제어계통을 갖는 냉동기의 최적제어에 관한 연구)

  • Ha, J.S.;Kim, W.N.;Kim, K.K.;Oh, C.
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.9 no.4
    • /
    • pp.317-327
    • /
    • 1985
  • In the case of temperature control of air conditioning and refrigerating system, it is possible to operate the system continuously by controlling the cooling capacity of refrigerating machines. But on-off control system has been adopted for refrigerating system which has more large capacity than that required to remove the generated heat. In this on-off control system, it can be considered that there exists some optimum condition for the refrigerating capacity, operating cycle, running hour, and the temperature difference between thermostat setting value and real one. In this paper, an equation was derived to express the temperature variation of the refrigerated object (Nybrine) and later two evaluating functions were derived. One is for the temperature difference and another is for operating cycle and running hour. The weighted sum of these two functions is defined as the criterion function for the evaluation of the control performance of the system, and then the optimum running condition is investigated in the sense of minimizing the criterion function. Experiments showed that the heat balance equation derived for the temperature variation and the estimation of the time constant of the refrigerated system are appropriate. By conclusion, if a proper weighting factor D is selected, the optimum conditions exist for the refrigerating capacity, running hour, and operating cycle in the on-off temperature control of the refrigerating system.

  • PDF

Assessment of 8-isoprostane (8-isoPGF2α) in Urine of Non-Small Cell Lung Cancer (NSCLC) Patients Undergoing Chemotherapy

  • Johns, Nutjaree Pratheepawanit;Johns, Jeffrey Roy
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.13 no.3
    • /
    • pp.775-780
    • /
    • 2012
  • 8-isoprostane (8-$isoPGF_{2{\alpha}}$) is a reliable marker and considered a gold standard for lipid peroxidation. There are very few reports of 8-isoprostane levels in cancer patients, and in patients undergoing chemotherapy. Oxidative stress is however expected and has been observed in patients with cancer. This study measured 8-isoprostane levels in urine by ELISA of 25 patients undergoing chemotherapy for advanced non-small cell lung cancer, at cycles 1, 2, and 3 of treatment. It considers the creatinine clearance of the patients, and correction of 8-isoprostane levels by creatinine clearance, and overnight urine volume methods. The average 8-isoprostane levels in urine increased more than 6 to 12 fold on chemotherapy treatment, from $532{\pm}587$ pg/mL at cycle $1,6181{\pm}4334$ at cycle 2, and $5511{\pm}2055$ at cycle 3. Similar results were obtained if 8-isoprostane levels were corrected for overnight urine volume, giving averages of $285{\pm}244{\mu}g$ at cycle $1,4122{\pm}3349$ at cycle 2, and $3266{\pm}1200$ at cycle 3. No significant difference was seen in average total overnight urine volume or number of urinations between chemotherapy cycles except for a large variation in urine volume between cycle 2 and 3. Creatinine levels were significantly different only between cycles 1 and 2 (p=0.016). In conclusion, cisplatin therapy has been shown to induce high levels of lipid peroxidation in lung cancer patients and can be assessed from the 8-isoprostane marker in overnight urine, with or without urine volume correction.

Merging and Splitting of Coronal Holes through a Solar Cycle

  • Jang, Min-Hwan;Choe, G.S.;Hong, Sun-Hak;Woods, Tom
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.36 no.2
    • /
    • pp.99-99
    • /
    • 2011
  • A statistical study of coronal hole merging and splitting has been performed through Solar Cycle 23. The NOAA/SESC solar synoptic maps are examined to identify inarguably clear events of coronal hole merging and splitting. The numbers of merging events and splitting events are more or less comparable regardless of the phase in the solar cycle. The number of both events, however, definitely shows the phase dependence in the solar cycle. It apparently has a minimum at the solar minimum whereas its maximum is located in the declining phase of the sunspot activity, about a year after the second peak in Solar Cycle 23. There are more events of merging and splitting in the descending phase than in the ascending phase. Interestingly, no event is found at the local minimum between the two peaks of the sunspot activity. This trend can be compared with the variation of the average magnetic field strength and the radial field component in the solar wind through the solar cycle. In Ulysses observations, both of these quantities have a minimum at the solar minimum while their maximum is located in the descending phase, a while after the second peak of the sunspot activity. At the local minimum between the two peaks in the solar cycle, the field strength and the radial component both have a shallow local minimum or an inflection point. At the moment, the physical reason for these resembling tendencies is difficult to understand with existing theories. Seeing that merging and splitting of coronal holes are possible by passage of opposite polarity magnetic structures, we may suggest that the energizing activities in the solar surface such as motions of flux tubes are not exactly in phase with sunspot generation, but are more active some time after the sunspot maximum.

  • PDF

An experimental study on the performance of inverter heat pump with a variation of frequency and capillary size (인버터 열펌프의 주파수 및 모세관 길이 변화에 따른 시스템 성능특성의 실험적 연구)

  • Choi, J.M.;Kim, Y.C.;Kim, J.Y.;Bae, Y.D.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.9 no.1
    • /
    • pp.64-72
    • /
    • 1997
  • An experiment study was performed to investigate the optimum cycle of an inverter heat pump as a function of frequency. The performance of the inverter heat pump with the rated cooling capacity of 4141W(3550kcal/h) was measured with a variation of frequency, indoor and outdoor temperature, and length of capillary tube in the psychrometric test room. As a base case, the inverter heat pump with the standard capillary length of 1000mm which was optimum size for the frequency of 60Hz and ARHRAE Test condition A was tested by varying frequency from 30Hz to 80Hz. Then, the optimum cycle was invesigated by varying the length of capillary tube at each frequency levels of 30, 60 and 80Hz. Based on the experimental data, the change of system characteristics between the optimum and the base case were analyzed for each selected frequency levels. Generally, for low frequency level(30Hz), the longer length of the capillary tube compared with the standard size showed the higher EER, while for high frequency level(80Hz) the shorter length of the capillary tube showed the higher EER.

  • PDF