• Title/Summary/Keyword: Cycle by Cycle Variation

Search Result 553, Processing Time 0.027 seconds

The Analysis of Temporal and Spatial Variation on the Vegetation Area of the Siwha Tidat Flat (시화 갯벌식생범위의 시-공간적 변이 분석)

  • Jeong, Jong-Chul
    • Journal of Environmental Impact Assessment
    • /
    • v.20 no.3
    • /
    • pp.349-356
    • /
    • 2011
  • This research is aim to analyze of changing landscape and according to phenological cycle from image information of coastal environment obtained by multi-media were analyzed by camera and satellite image. The digital camera and satellite image were used for tidal flat vegetation monitoring during the construction of Sihwa lake. The vegetation type and phenological cycle of Sihwa tidal flat have been changed with the Sihwa lake ecosystem. The environment changes of Sihwa tidal flat area and ecological change were analyzed by field work digital camera images and satellite images. The airborne, UAV and satellite images were classified with the changed elements of coastal ecological environment and tidal flat vegetation monitoring carried out the changed area and shape of vegetation distribution with time series images.

A study on the optimum control of refrigerator with on-off control system (On-off 제어계통을 갖는 냉동기의 최적제어에 관한 연구)

  • Ha, J.S.;Kim, W.N.;Kim, K.K.;Oh, C.
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.9 no.4
    • /
    • pp.317-327
    • /
    • 1985
  • In the case of temperature control of air conditioning and refrigerating system, it is possible to operate the system continuously by controlling the cooling capacity of refrigerating machines. But on-off control system has been adopted for refrigerating system which has more large capacity than that required to remove the generated heat. In this on-off control system, it can be considered that there exists some optimum condition for the refrigerating capacity, operating cycle, running hour, and the temperature difference between thermostat setting value and real one. In this paper, an equation was derived to express the temperature variation of the refrigerated object (Nybrine) and later two evaluating functions were derived. One is for the temperature difference and another is for operating cycle and running hour. The weighted sum of these two functions is defined as the criterion function for the evaluation of the control performance of the system, and then the optimum running condition is investigated in the sense of minimizing the criterion function. Experiments showed that the heat balance equation derived for the temperature variation and the estimation of the time constant of the refrigerated system are appropriate. By conclusion, if a proper weighting factor D is selected, the optimum conditions exist for the refrigerating capacity, running hour, and operating cycle in the on-off temperature control of the refrigerating system.

  • PDF

An experimental study on the performance of inverter heat pump with a variation of frequency and capillary size (인버터 열펌프의 주파수 및 모세관 길이 변화에 따른 시스템 성능특성의 실험적 연구)

  • Choi, J.M.;Kim, Y.C.;Kim, J.Y.;Bae, Y.D.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.9 no.1
    • /
    • pp.64-72
    • /
    • 1997
  • An experiment study was performed to investigate the optimum cycle of an inverter heat pump as a function of frequency. The performance of the inverter heat pump with the rated cooling capacity of 4141W(3550kcal/h) was measured with a variation of frequency, indoor and outdoor temperature, and length of capillary tube in the psychrometric test room. As a base case, the inverter heat pump with the standard capillary length of 1000mm which was optimum size for the frequency of 60Hz and ARHRAE Test condition A was tested by varying frequency from 30Hz to 80Hz. Then, the optimum cycle was invesigated by varying the length of capillary tube at each frequency levels of 30, 60 and 80Hz. Based on the experimental data, the change of system characteristics between the optimum and the base case were analyzed for each selected frequency levels. Generally, for low frequency level(30Hz), the longer length of the capillary tube compared with the standard size showed the higher EER, while for high frequency level(80Hz) the shorter length of the capillary tube showed the higher EER.

  • PDF

Regression Analysis of Life Cycle Profile for Life Cycle Cost and Bridge Management System (교량관리체계 개선 및 LCC분석을 위한 생애주기 성능이력 회귀함수의 산정)

  • Kong, Jung-Sik;Park, Heung-Min;Lee, Kwan-Kyun;Park, Chang-Ho;Shin, Jae-In
    • Proceedings of the Korean Institute Of Construction Engineering and Management
    • /
    • 2008.11a
    • /
    • pp.149-154
    • /
    • 2008
  • Service life of bridges should be evaluated by physical life considering damage/deterioration. But it is difficult to identify optimal maintenance scenario due to insufficient research related to that. To identify optimal maintenance scenario, it is needed to develope life cycle profile model of condition state variation by deterioration factor. The LCP model has been developed in consideration of regression analysis and survey in this study. It is expected that the LCP model could help to achieve HBMS system improvement.

  • PDF

FRACTAL DIMENSION AND MAXIMUM SUNSPOT NUMBER IN SOLAR CYCLE (태양주기별 흑점수의 프랙탈 차원과 최대흑점수의 상관관계)

  • Kim R.S.;Yi Y.;Cho K.S.;Moon Y.J.;Kim S.W.
    • Journal of Astronomy and Space Sciences
    • /
    • v.23 no.3
    • /
    • pp.227-236
    • /
    • 2006
  • The fractal dimension is a quantitative parameter describing the characteristics of irregular time series. In this study, we use this parameter to analyze the irregular aspects of solar activity and to predict the maximum sunspot number in the following solar cycle by examining time series of the sunspot number. For this, we considered the daily sunspot number since 1850 from SIDC (Solar Influences Data analysis Center) and then estimated cycle variation of the fractal dimension by using Higuchi's method. We examined the relationship between this fractal dimension and the maximum monthly sunspot number in each solar cycle. As a result, we found that there is a strong inverse relationship between the fractal dimension and the maximum monthly sunspot number. By using this relation we predicted the maximum sunspot number in the solar cycle from the fractal dimension of the sunspot numbers during the solar activity increasing phase. The successful prediction is proven by a good correlation (r=0.89) between the observed and predicted maximum sunspot numbers in the solar cycles.

Changes in the Business Cycle of the Korean Economy: Evidence and Explanations (한국 경기변동의 특징 및 안정성에 대한 연구)

  • Lee, Jaejoon
    • KDI Journal of Economic Policy
    • /
    • v.31 no.2
    • /
    • pp.47-85
    • /
    • 2009
  • With a relatively simple quantitative method, this study comprehensively analyzes the characteristics related to business cycles represented by macroeconomic variables of Korea since 1970. This empirical analysis deals with roughly following three topics: How to identify cyclical component with respect to trend; with what characteristics and how the economic variables of each sector move with in the phases of business cycle, and; whether there are signs of a structural change in the phases of business cycle. Section 2 discusses how to identify trends and cycle components, the basis assumption for the analysis of business cycle. Like the Korean economy, where a relatively high growth rate has been maintained, it is appropriate to determine its economic recession based on the fall in the growth trend, not in the absolute level of real output. And, it is necessary to apply the concept of growth cycle against a traditional concept of business cycle. Accordingly the setting of growth trend is of preliminary importance in identifying cyclical fluctuations. The analysis of Korea's GDP data since 1970, the decomposition of trends and cycles through the Band-pass filter is found to appropriately identify the actual phases of busyness cycle. Section 3 analyzes what particular relationship various economic variables have with output fluctuations during the phases of economic cycle, using the corss-correlation coefficients and prediction contribution. Section 4 monitors the stability of the phases of Korea's business cycle and quantitatively verifies whether there is a structural break, and then reviews the characteristics of variations in each sector. And, stylized facts observed through these studies are summarized in the conclusion. The macroeconomic stability of Korea, in particular, is found to continue to improve since 1970, except for the financial crisis period. Not only that, it is found that its volatility of economic growth rate as well as inflation have been reduced gradually. Meanwhile, until recently since 2000, the volatility in domestic demand has remained stable, while that in exports and imports has been increased slightly. But, in an over all perspective, Korea's business cycle variation is on the decline due to shorter response period to shocks and the formation of complementary relationship among economic sectors.

  • PDF

Comparison of Performance Characteristics with Heat Exchanger Type in $CO_2$ Cycle (이산화탄소 사이클에서 열교환기의 형태 변화에 따른 성능특성 비교)

  • Bae, Kyung-Jin;Cho, Hong-Hyun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.10
    • /
    • pp.657-664
    • /
    • 2010
  • The theoretical analysis of performance characteristics in a $CO_2$ cycle with the heat exchanger type was carried out. The size and performance of the fin-tube and microchannel heat exchanger were compared with operating conditions. As a result, the performance of the fin-tube gascooler and evaporator were more sensitive to the variation of operating condition compared to that of the microchannel gascooler and evaporator. Beside, the sizes of microchannel gascooler and evaporator could be decreased by 73% and 76%, respectively, compared to those of the fin-tube type gascooler and evaporator with the similar capacity. The COP and reliability of the $CO_2$ system can be increased by using a microchannel heat exchanger.

A Study on Annealing Cycle Control Temperature of Hi - CON/2 BAF and HNx BAF (Hi-CON/H2 BAF와 HNx BAF의 소둔사이클 제어온도에 관한 연구)

  • 김문경
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.18 no.1
    • /
    • pp.114-122
    • /
    • 1994
  • A cold temperature control system for the BAF(batch annealing furnace) has been established in order to reduce energy consumption to imrpove productivity and stabilize the properties of products. Therefore we confirmed a relation between annealing cycle time and atmospheric gas, changing annealing cycle time according to BAF temperature with time during heating and actual temperature measurements cold spot during soaking. The results of the temperature variation effect on the batch annealing are as follows. 1) Cooling rate is increasing gradually with increasing atmospheric gas flow, but heating rate is hardly increasing without atmospheric gas component. Heating time is reduced to one half with increasing atmospheric gas flow rate and changing of atmospheric gas component from HNx to Ax gas and annealing cycle time is reduce to 2.7 times. 2) With enlarging the difference between furnace temperature and soaking temperature at the HNx BAF, heating time becomes short, but cooling time is indifferent. 3) If temperature difference of 300.deg. C in the temperature change of cold spot according to the annealing cycle control temperature, Hi-CON/H2BAF is interchanging at each other at 26hours, but HNxBAF at 50 hours. 4) Soaking time at batch annealing cycle determination is made a decision by the input coil width, and soaking time for quality homogenization of 1219 mm width coil must be 2.5 hours longer then that of 914mm width coil for the same coil weight at Hi-CON/H2BAF. But, it is necessary to make 2 hours longer at HNxBAF.

  • PDF

Merging and Splitting of Coronal Holes through a Solar Cycle

  • Jang, Min-Hwan;Choe, G.S.;Hong, Sun-Hak;Woods, Tom
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.36 no.2
    • /
    • pp.99-99
    • /
    • 2011
  • A statistical study of coronal hole merging and splitting has been performed through Solar Cycle 23. The NOAA/SESC solar synoptic maps are examined to identify inarguably clear events of coronal hole merging and splitting. The numbers of merging events and splitting events are more or less comparable regardless of the phase in the solar cycle. The number of both events, however, definitely shows the phase dependence in the solar cycle. It apparently has a minimum at the solar minimum whereas its maximum is located in the declining phase of the sunspot activity, about a year after the second peak in Solar Cycle 23. There are more events of merging and splitting in the descending phase than in the ascending phase. Interestingly, no event is found at the local minimum between the two peaks of the sunspot activity. This trend can be compared with the variation of the average magnetic field strength and the radial field component in the solar wind through the solar cycle. In Ulysses observations, both of these quantities have a minimum at the solar minimum while their maximum is located in the descending phase, a while after the second peak of the sunspot activity. At the local minimum between the two peaks in the solar cycle, the field strength and the radial component both have a shallow local minimum or an inflection point. At the moment, the physical reason for these resembling tendencies is difficult to understand with existing theories. Seeing that merging and splitting of coronal holes are possible by passage of opposite polarity magnetic structures, we may suggest that the energizing activities in the solar surface such as motions of flux tubes are not exactly in phase with sunspot generation, but are more active some time after the sunspot maximum.

  • PDF

Alteration of Thyroid Function in Indian HER 2-Negative Breast Cancer Patients Undergoing Chemotherapy

  • Ashif Khan, Mohd;Bhurani, Dinesh;Agarwal, Nidhi B
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.17
    • /
    • pp.7701-7705
    • /
    • 2015
  • Background: Thyroid hormones (TH) are regulated by the hypothalamic-pituitary axis, which plays an important role in cell growth, differentiation, development and other aspects of metabolism. It is believed that an active hypothalamic-pituitary axis increases the susceptibility of thyroid dysfunction during systemic chemotherapy. In order to investigate the relation between thyroid function and chemotherapy the present study was designed to investigate TH in breast cancer patients receiving at least three cycles of chemotherapy. The levels of TH were measured at the baseline and before each cycle of chemotherapy. Materials and Methods: Blood samples for estimation of TH levels were collected from 80 (pre-menopausal-40; post-menopausal-40) breast cancer patients just before they were undergoing - $1^{st}$, $2^{nd}$, $3^{rd}$ and $4^{th}$ cycle of chemotherapy. The serum was separated and $T_3$, $T_4$ and TSH levels were determined by chemiluminescence method. Results: $T_3$ and $T_4$ were found significantly decreased and TSH was found significantly increased after $1^{st}$ (p<0.001), $2^{nd}$ (p<0.0001) and $3^{rd}$ cycle of chemotherapy (p<0.0001). The variation of $T_3$ levels (decreased) and TSH levels (increased) was found more in post-menopausal (p<0.0001) women then in pre-menopausal women after $3^{rd}$ cycle of chemotherapy as compared to baseline (p<0.001). Conclusions: TH were remarkably altered after each cycle of chemotherapy leading to decline in thyroid function of breast cancer patients. Further, the results also indicated that post-menopausal women were more prone towards decline in thyroid function then pre-menopausal women. The present study proposes the monitoring of TH after each cycle of chemotherapy in breast cancer patients.