• 제목/요약/키워드: Cycle analysis

검색결과 6,113건 처리시간 0.033초

SWAT모델과 물수지분석을 이용한 물재이용에 의한 도시물순환 변화 분석 (Analysis for water cycle change using SWAT model and water balance analysis depending on water reuse in urban area)

  • 김영란;황성환;이성옥
    • 상하수도학회지
    • /
    • 제29권4호
    • /
    • pp.447-457
    • /
    • 2015
  • Water cycle within the human civilization has become important with urbanization. To date, water cycle in the eco-system has been the focus in identifying the degree of water cycle in cities, but in practicality, water cycle within the human civilization system is taking on an increasing importance. While in recent years plans to reuse water have been implemented to restore water cycle in cities, the effect that such reuse has on the entire water cycle system has not been analyzed. The analysis on the effect that water reuse has on urban areas needs to be go beyond measuring the cost-savings and look at the changes brought about in the entire city's water cycle system. This study uses a SWAT model and water balance analysis to review the effects that water reuse has on changes occurring in the urban water cycle system by linking the water cycle within the eco-system with that within the human civilization system. The SWAT model to calculate the components of water cycle in the human civilization system showed that similar to measured data, the daily changes and accumulative data can be simulated. When the amount of water reuse increases in urban areas, the surface outflow, amount of sewer discharge and the discharged amount from sewage treatment plants decrease, leading to a change in water cycle within our human civilization system. The determinant coefficients for reduced surface outflow amount and reduced sewer discharge were 0.9164 and 0.9892, respectively, while the determinant coefficient for reduced discharge of sewage treatment plants was 0.9988. This indicates that with an increase in water reuse, surface flow, sewage and discharge from sewage treatment plants all saw a linear reduction.

OPR1000 발전소의 핵연료 주기비분석을 통한 최적 배취 크기와 핵연료 농축도 결정 (Determination of Optimum Batch Size and Fuel Enrichment for OPR1000 NPP Based on Nuclear Fuel Cycle Cost Analysis)

  • 조성주;하창주
    • 에너지공학
    • /
    • 제23권4호
    • /
    • pp.256-262
    • /
    • 2014
  • 국내 원자력발전소의 주기길이는 전력회사의 전력수급계획에 따라 결정된다. 주기길이는 노심에 장전할 신연료 다발수와 핵연료 농축도를 조정하여 결정할 수 있다. 전력회사에서는 특정 주기길이를 만족시키기 위한 방법으로 신연료 다발수를 정한 후 핵연료 농축도를 결정하는 방법을 적용하고 있다. 그러나 이 방법의 경우 같은 주기길이를 갖는 다른 신연료 다발수와 핵연료 농축도의 조합들 보다 핵연료 주기비 측면에서 가장 경제적인지 판단할 수가 없다. 따라서 본 분석에서는 상용 노심설계 코드인 CASMO/MASTER 코드를 사용하여 OPR1000(Optimized Power Reactor 1000) 발전소를 대상으로 신연료 다발수와 핵연료 농축도 조합에 대한 노심 연소계산을 수행하여 동일한 주기길이를 갖는 최적의 신연료 다발수와 핵연료 농축도 조합은 무엇인지 분석하였다. 천이노심계산에서 발생할 수 있는 불확실도를 최소화하기 위해 노심 특성인자들이 변하지 않는 평형노심(equilibrium cycle)까지 계산을 수행하여 이때의 계산결과를 핵연료 주기비 계산에 사용하였다. 또한 평준화 핵연료 주기비(levelized fuel cycle cost) 계산에 있어 중요한 인자인 할인율(discount rate)에 대해서 국내뿐만 아니라 다른 나라의 실정에도 적용 가능하도록 민감도 분석을 수행하였다. 평준화 핵연료 주기비(levelized fuel cycle cost) 평가 결과 할인율(discount rate)이 낮은 경우 신연료 다발수는 줄이고 대신 핵연료 농축도를 높이는 조합을 통해 특정 주기길이를 만족시키는 방법이 경제적인 것으로 나타났다. 반면 할인율(discount rate)이 높은 경우는 핵연료 농축도는 낮추고 신연료 다발수를 늘리는 조합을 통해 특정 주기길이를 만족시키는 방법이 경제적인 것으로 나타났다.

군용 기동장비의 가용도 분석을 통한 교체시기 결정에 관한 연구 ­2 \frac{1}{2} 톤 차량을 중심으로­ (A Study on the Determination of Replacement Time for Military Vehicle Using Availability Analysis ­ Focused on 2 \frac{1}{2} Ton Cargo­)

  • 하형호;강성진
    • 한국국방경영분석학회지
    • /
    • 제29권2호
    • /
    • pp.81-99
    • /
    • 2003
  • This paper propose a method determining life cycle for military vehicle using availability analysis. Many studies determining life cycle for military equipments have been done recently However, those studies focused on economic life such as average system cost method, equivalent annual cost method and cumulative operations cost method. In many case, those results are not appropriate in deciding replacement in the field situation, we consider an effective life cycle method using availability concept. In order to determine an equipment life cycle. Two kinds of availability is considered. One is equipment yearly availability, the other is operational availability with operating distance per year. The life cycle is determined by achieving unit target availability level. The result using this concept for K­511 military vehicle life cycle is about 19 years, which is longer than previous studies.

Cell Cycle Regulation in the Budding Yeast

  • Nguyen, Cuong;Yoon, Chang-No;Han, Seung-Kee
    • 한국생물정보학회:학술대회논문집
    • /
    • 한국생물정보시스템생물학회 2005년도 BIOINFO 2005
    • /
    • pp.278-283
    • /
    • 2005
  • Cell cycle is regulated cooperatively by several genes. The dynamic regulatory mechanism of protein interaction network of cell cycle will be presented taking the budding yeast as a sample system. Based on the mathematical model developed by Chen et at. (MBC, 11,369), at first, the dynamic role of the feedback loops is investigated. Secondly, using a bifurcation diagram, dynamic analysis of the cell cycle regulation is illustrated. The bifurcation diagram is a kind of ‘dynamic road map’ with stable and unstable solutions. On the map, a stable solution denotes a ‘road’ attracting the state and an unstable solution ‘a repelling road’ The ‘START’ transition, the initiation of the cell cycle, occurs at the point where the dynamic road changes from a fixed point to an oscillatory solution. The 'FINISH' transition, the completion of a cell cycle, is returning back to the initial state. The bifurcation analysis for the mutants could be used uncovering the role of proteins in the cell cycle regulation network.

  • PDF

Solar tower combined cycle plant with thermal storage: energy and exergy analyses

  • Mukhopadhyay, Soumitra;Ghosh, Sudip
    • Advances in Energy Research
    • /
    • 제4권1호
    • /
    • pp.29-45
    • /
    • 2016
  • There has been a growing interest in the recent time for the development of solar power tower plants, which are mainly used for utility scale power generation. Combined heat and power (CHP) is an efficient and clean approach to generate electric power and useful thermal energy from a single heat source. The waste heat from the topping Brayton cycle is utilized in the bottoming HRSG cycle for driving steam turbine and also to produce process steam so that efficiency of the cycle is increased. A thermal storage system is likely to add greater reliability to such plants, providing power even during non-peak sunshine hours. This paper presents a conceptual configuration of a solar power tower combined heat and power plant with a topping air Brayton cycle. A simple downstream Rankine cycle with a heat recovery steam generator (HRSG) and a process heater have been considered for integration with the solar Brayton cycle. The conventional GT combustion chamber is replaced with a solar receiver. The combined cycle has been analyzed using energy as well as exergy methods for a range of pressure ratio across the GT block. From the thermodynamic analysis, it is found that such an integrated system would give a maximum total power (2.37 MW) at a much lower pressure ratio (5) with an overall efficiency exceeding 27%. The solar receiver and heliostats are the main components responsible for exergy destruction. However, exergetic performance of the components is found to improve at higher pressure ratio of the GT block.

칼리나 사이클을 기반으로 하는 동력 및 냉동 복합 사이클의 에너지 및 엑서지 성능 해석 (Energy and Exergy Analysis of Kalina Based Power and Cooling Combined Cycle)

  • 김경훈;정영관;고형종
    • 한국수소및신에너지학회논문집
    • /
    • 제31권2호
    • /
    • pp.242-249
    • /
    • 2020
  • The Kalina cycle (KC) is considered as one of the most efficient systems for recovery of low grade heat. Recently, Kalina based power and cooling cogeneration cycles (KPCCCs) have been suggested and attracted much attention. This paper presents an energy and exergy analysis of a recently suggested KPCCC with flexible loads. The cycle consists of a KC (KCS-11) and an aqua-ammonia absorption refrigeration cycle. By adjusting the splitting ratios, the cycle can be operated with four modes of pure Kalina cycle, pure absorption cooling cycle, Kalina-cooling parallel cycle, and Kalina-cooling series cycle. The effects of system variables and the operating modes on the energetic and exergetic performances of the system are parametrically investigated. Results show that the system has great potential for efficient utilization of low-grade heat source by adjusting loads of power and cooling.

운동기능성 향상을 위한 여성용 사이클웨어 상의 개발 (Development of Women's Cycle Wear Top with Improved Function)

  • 권채령;김동은
    • 한국의류산업학회지
    • /
    • 제21권1호
    • /
    • pp.75-87
    • /
    • 2019
  • The purpose of the study was to suggest a cycle wear top jersey improved in mobility. The study developed a new cycle wear with improvement in dissatisfaction factors by planning design, pattern and the functionality of fabric. Considering the amount of sweat and the necessities of compression part, the basic material, the additional compression material, and the mesh material were arranged differently according to areas. The assessment of the developed cycle wear was composed of wearing comfort evaluation by female cyclist, photo analysis and garment pressure evaluation. The developed cycle wear was evaluated and compared with the current cycle wear. As a result of wearing comfort evaluation, the developed cycle wear was evaluated as better than the existing ones in all part, particularly in the areas of reflection tape and materials, partial pressure, pocket size, and prevention of loss. Photo analysis was in agreement with the appearance evaluation of the participants. As a result of garment pressure evaluation, the front neck part was more comfortable and the upper arm, abdomen, and waist area showed higher pressure, so it partially supported the body. This study has significant meaning for developing a new cycle wear top, protecting the body and improving the exercise effect.

저온 해수를 이용한 난방 및 담수화사이클 성능 해석 (Analysis of Heating and Desalination Cycle Using Low Temperature Seawater)

  • 이호생;이승원;정동호;문덕수;김현주
    • 한국해양환경ㆍ에너지학회지
    • /
    • 제14권4호
    • /
    • pp.301-306
    • /
    • 2011
  • 저온 해수에너지를 이용한 난방사이클 및 이와 연계할 수 있는 적정 담수화사이클에 대하여 제안 및 해석을 수행하였다. 난방사이클은 기본 증기압축식 사이클을 이용하여 1단 및 2단압축사이클에 대해 해석을 수행하였고, 담수화사이클은 난방사이클과 연계할 수 있도록 설계하여 해석을 수행하였다. 난방사이클의 증발기 열원으로 5이하의 저온 해수열을 이용하였고, 난방수 온도는 60 이상 공급될 수 있도록 해석하였으며, 사이클 작동유체는 R-134a, R-1234 yf, R-600a를 적용하였다. 사이클 해석 결과, 2단압축사이클을 적용할 경우 1단압축사이클에 비해 모든 냉매에서 압축기 소요동력은 약 15.6% 감소하였고, 성능계수는 약 17.6% 향상되었다. 냉동법 담수화 사이클의 경우 R-134a에 대해서 난방수 60 조건일 때, 1단압축 사이클에 비해 2단압축사이클을 적용할 경우 담수 1kg 생산당 에너지가 약 19.8% 감소하는 것으로 나타났다.

Development of Performance Analysis System (NOPAS) for Turbine Cycle of Nuclear Power Plant

  • Kim, Seong-Kun;Park, Kwang-Hee
    • Nuclear Engineering and Technology
    • /
    • 제33권1호
    • /
    • pp.34-45
    • /
    • 2001
  • We have needs to develop a performance analysis system that can be used in domestic nuclear power plants to determine performance status of turbine cycle. We developed new NOPAS system to aid performance analysis of turbine cycle . Procedures of performance calculation are improved using several adaptations from standard calculation algorithms based on ASME (American Society of Mechanical Engineers) PTC (Performance Test Code). Robustness in the performance analysis is increased by verification & validation scheme for measured input data. The system also provides useful aids for performance analysis such as graphic heat balance of turbine cycle and components, turbine expansion lines, automatic generation of analysis reports.

  • PDF

LCC분석에 의한 설비시스템의 최적화 방안에 관한 연구 - G구 구민회관 및 구의회청사 사례 - (A Study on Optimized Design Decision of Building Service Systems Based on a Life-Cycle Cost Analysis - A Case Study on Community Center and Congress Hall of a Local Government -)

  • 최성호;차병주;김상민;이승복
    • 설비공학논문집
    • /
    • 제14권2호
    • /
    • pp.134-142
    • /
    • 2002
  • LCC (Life-Cycle Cost) analysis is a practical method and a guideline for evalua-ting the economic performance of building service systems. By using the LCC analysis, the most cost-effective design decision can be made, which has the lowest LCC during the project study period among the various design alternatives. The present case shows an example of appro-priate use of the LCC analysis, by demonstrating the procedures of decision making among at-tarnative building HVAC systems at community center and congress hall of a local government.