• 제목/요약/키워드: Cybex

검색결과 65건 처리시간 0.017초

인체 동작 분석기의 개발 (Development of a Human Motion Analyzer)

  • 김민기;김성호
    • 대한의용생체공학회:의공학회지
    • /
    • 제16권2호
    • /
    • pp.217-222
    • /
    • 1995
  • We propose some applications of image processing techniques to extract quantitative measurements by using a camera system developed in Korea university and Catholic Medical School. From now on the system will be called as KCMOTION. The purpose of this study is to provide basic kinematic and kinetic data for the analysis of human movements and to find the clinical usefulness and reliability of the proposed motion analysis system. Two tests, sit-to-stand (STS) movements and pendulum test, are conducted by the system. The aims of the tests are to identify variability and reliability of KCMOTION to give some quantitative comparisons to the other systems. The result of STS movement are compared to the LOCUS IIID motion analyzer by the ratio of maximum flexion movement per body weight to the actual maximum flexion extension torque per body weight. That result in 29 % and 33 % for hip and knee joint, respectively in KCMOTION and 27 % and 30 % in LOCUS IIID System. The results of the pendulum movements are compared to that of using Cybex and Electrogoniometer with relaxation index, amplitude ratio, swing number and swing time. The results of relaxation index and amplitude ratio of the KCMOTION are between those of the Cybex and Electrogoniometer. We also observed that the KCMOTION detect more natural movement, from the results of swing number and time.

  • PDF

작업환경과 요통이 요추의 구조 및 근력의 변화에 미치는 영향 (Effect of Work Environment and Low Back Pain on the Structural and Muscle Strength Changes in Lumbar Spine)

  • 김나연;강재희;이현
    • Journal of Acupuncture Research
    • /
    • 제27권3호
    • /
    • pp.93-104
    • /
    • 2010
  • Objectives : The purpose of this study is to observe the effects of work environment and low back pain on the structural and muscle strength changes in lumbar spine to helpful for preventation and cure of low back pain. Methods : Through measuring of lumbosacral angle, lumbar lordotic angle, lumbar gravity line ratio analyzed structure of lumbar spine and using Trunk Extension Flexion Program of CYBEX NORM System(cybex770+TMC, USA) analyzed Flex. PT, Ext. PT, E/F ratio of lumbar spine of company employees given a medical examination. Results : According to work environment, lumbar gravity line ratio is higher in white collar group than in blue collar group, Ext. PT is significantly lower in white collar group than in blue collar group. According to low back pain or not, lumbar gravity line ratio, Ext. PT is lower in low back pain group than in non-low back pain group. Conclusions : Work environment and low back pain effects on the structural and muscle strength changes in lumbar spine.

INFLUNCE OF ELECTRO-MYOSCOPE(ACUSCOPE) ON INJURED QUADRICEPS FEMORIS WITH USING ELECTRO_MYOGRAPHIC ANALYSIS BUILT INTO THE ELCETROMYOSCOPE

  • 송병호
    • 대한물리치료과학회지
    • /
    • 제7권2호
    • /
    • pp.697-709
    • /
    • 2000
  • 이 실험의 목적은 Electro-Myoscope 이 과다 사용에 의해 일어나는 대퇴사두 근육 통증에 미치는 효과에 대해 근전도를 이용한 연구입니다. 이를 위해 나이 15세부터 50세 사이의 18명의 여성 자원자들이 참여했다. 대퇴직근을 Cybex 운동기기를 사용해 Terminal knee extension 운동을 통해 과다사용으로 인한 통증이 유발되게 하였다. 그리고, Electro-Myoscope을 치료 후 근전도를 통해 대퇴사두근의 motor recruit 에 대해 기록 비교하였다. t-test 와 Chi square 분석 결과 대퇴사두근의 기능이 향상된 것으로 나타났다.

  • PDF

PNF 패턴에 기초한 탄력밴드 훈련이 척수손상 환자의 상지 기능에 미치는 영향 (The effect of elastic band based of PNF pattern on the U/E function in the spinal cord injury patient)

  • 신영일;이형수
    • The Journal of Korean Physical Therapy
    • /
    • 제16권3호
    • /
    • pp.152-160
    • /
    • 2004
  • The purpose of this study was to investigate the effect of elastic band based of PNF pattern on the U/E function in the spinal cord injury patient. 11 subjects with spinal cord injury participated in this study. They took elastic band excercise 5 times per week for 8 weeks. One time excercise spent 35minutes. The therapeutic effect was evaluated by Cybex 6000, BTE Work Simulator, how many seconds they needed to walk 100 meters. 11 cases were examined before, after 8 week, elastic band excercise. The results of this study are as follows; 1. Isokinetic power by Cybex 6000 : The elbow flexion, shoulder flexion and extension were significant difference between test-retest(p<.05). but elbow extension were not significant difference between test-retest. 2. BTE Work Simulator : Wheelchair Propulsion and Steering Torque were significant difference between test-retest(p<.05). 3. Wheelchair Propulsion velocity : There were significant difference between test-retest(p<.05). The findings suggest that SCI patients can improve their Isokinetic power on shoulder and elbow joint, wheelchair propulsion and Steering Torque by BTE Work Simulator, Wheelchair Propulsion velocity through elastic band based of PNF pattern.

  • PDF

등속운동 훈련장치의 개발 및 이의 성능시험에 관한 연구 (Development of Isokinetic Exercise System and Examination of Its Performance)

  • 윤용산;조영돈
    • 대한의용생체공학회:의공학회지
    • /
    • 제11권1호
    • /
    • pp.39-46
    • /
    • 1990
  • An isokinetic exercise system was designed and manufactured to perform muscular performance test and the traning of athletes and the rehabilitation of patients. The system majorly consists of gear box, D. C servo motor and servo controller, data reduction computer. Preliminary experiments were conducted to find out the performance of the system. The performance of the prototype isokinetic exercise system was turned out to be satisfactory compared with a commercial product called CYBEX system.

  • PDF

3D 밀착형 팬츠와 키네시오 테이핑이 무릎관절의 등속성 굴곡 운동 시 하지의 근기능에 미치는 영향 (Effects of 3D Compression Pants and Kinesio Taping on Isokinetic Muscular Function of Leg During Knee Joint Flexion Motion)

  • 최지영;박희근;이왕록;홍경희
    • 한국의류학회지
    • /
    • 제40권2호
    • /
    • pp.240-257
    • /
    • 2016
  • This study determines the effect of 3D compression pants and Kinesio taping on muscular function of the leg during knee joint flexion and extension. Eight males participated in the experiment, wearing basic pants (BP), Kinesio taping on bare skin (KT), 3D compression pants with (KTP) and without Kinesio taping (CP). The test protocol for isokinetic muscular function was composed of four sets at three angular velocities (60, 180, $240^{\circ}/sec$) using Cybex 660. Peak torque and work per repetition of the lower limbs of eight males were analyzed from the result of Cybex. Agility and power of the subjects were examined from side step and sergeant jump. Peak torque, average power, work per repetition, force decay time of subjects wearing CP and KTP were significantly better than BP or KT, especially at low angular velocity of $60^{\circ}/sec$. The time to generate peak torque of subjects wearing BP was the longest, while the force-decay time of BP was the shortest. The application of Kinesio tape on skin did not increase muscle peak torque, work and power, but did shorten the time to generate peak torque.

상완골 회전에 따른 견관절 가동 범위의 변화 (The Change with Range of Motion in Grenohumeral Joint by Humeral Rotation)

  • 정현애;김태윤;김호봉;최재원;김상수;배성수
    • The Journal of Korean Physical Therapy
    • /
    • 제13권1호
    • /
    • pp.115-125
    • /
    • 2001
  • The purpose of this study was to determine the relationship between rotation of the humerus and the shoulder movement in the sagital, coronal, and diagonal planes. Thirty normal subjects(15 male. 15 female)were tested using Cybex NORMTM Testing & Rehabilitation System (CYBEX Division of LUMEX, Inc., Ronkinkoma, New York). The subjects performed active shoulder flexion, abduction and PNF patterns. The range of motion(ROM) of the glenohumeral joint was measured three times. In order to assure the statistical significance of the results. the independent t-test. and a pearson's correlation were applied of the .05 and .01 level of significant. The results of this study were as follow ;1. There were statistically significant differences between shoulder flexion with humerus medial rotation and shoulder flexion with humerus lateral rotation(p <.01). 2. There were statistically significant differences between shoulder abduction with humerus medial rotation and shoulder abduction with humerus lateral rotation(p <.01). 3. There were statistically significant differences between PNF pattern(flex-abd-ext rot) with humerus medial rotation and PNF pattern with humerus lateral rotation(p < .01).For effective rehabilitation of the shoulder, physical therapists must have correct knowledge of shoulder movements. Physical therapists should consider these results when the goal of treatment is to increase ROM of the shoulder.

  • PDF

슬관절전치환술 환자의 슬관절 신전근 및 굴곡근에 대한 등속성운동 효과 (Isokinetic Effect of the Extensors and Flexors in Total Knee Replacement Patients)

  • 배성수;남건우;이근희
    • The Journal of Korean Physical Therapy
    • /
    • 제13권1호
    • /
    • pp.19-31
    • /
    • 2001
  • The twenty one individuals with total knee replacement who were admitted to Kang-Dong Hospital for comprehensive physical therapy were studied in order to demonstrate the effectiveness of an isokinetic test program using the Cybex 6000 machine. The subjects were divided into three groups with the isometric exercise group receiving isometric exercise. the isokinetic eccentric exercise group, and isokinetic eccentric exorcise group receiving isokinetic exercise(eccentric. concentric) to knee flexors and extensors muscles for a six weeks period using the Cybex 6000. The results were follow :1 . The peak torque was increased significantly in the flexors and extensors of the isokinetic conccentric exorcise among three groups(p<.05). 2. The progress of peak torque was increased significantly in the flexors and extensors of the isokinetic conccentric exercise among three groups(p<.05). 3. The total work was more increased significantly in the flexors and extensors of the isokinetic conccentric exercise among three groups(p<.05). 4. The progress of total work was more increased significantly in the flexors and extensors of the isokinetic conccentric exercise among three groups(p<;.05). 5. The ratio of endurance was not increased significantly in all three groups. 6. The extensors in the peak torque was likely to recover rapidly than the flexors. 7.The average R.O.M in the pre-exercise and post-exercise was not different significantly in all three groups. According to the above results, In the muscle strength recovery for total knee replacement patients, isokinetic concentric exercise group was significantly greater than the isokinetic eccentric and isometric exercise groups after a six weeks training.

  • PDF

견갑면에서의 견관절 외전정도에 따른 등속성회전운동의 근력 평가 (An Evaluation for Isokinetic Strength During Shoulder Rotation Movement in the Scapular Plane with Various Abduction)

  • 최재원;김수민;김현애;김경;황보각;배성수
    • The Journal of Korean Physical Therapy
    • /
    • 제12권2호
    • /
    • pp.95-105
    • /
    • 2000
  • Glenohumeral internal and external rotation with shoulder abducted in the frontal plane often causes impingement of the supraspinatus tendon. whereas similar activity in scapular plane does not cause impingement. The Purpose of this study was to determine if assessment among the three positions as 30 degrees, 60 degrees, 90 degrees abduction in the sitting position of the scapular plane could be affected the comparison between intemal and external peak torque, total work, average power. In this study, Isokinetic shoulder rotational strength was evaluated in twenty healthy male university students, using the Cybex NORMTM System (CYBEX Division of LUMEX, Inc., Ronkonkoma, New York). Test data was gathered in the plane of the scapular, 30 degrees of horizontal flexion anterior to coronal plane, and the subjects performed the test with the arm 30, 60, and 90degrees abducted in the sitting position. also, test speed was set at deg/sec. Statistical analysis was performed using SPSS 7.5 for Windows software and mean and standard deviations were calculated. ANOVA was used to analyze the difference of the values in the three test positions. A paired t-test was used of examining the difference in the means peak torque between external and internal rotation. Not any significant difference was found among three abduction positions in scapular plane, even though there was a consistent pattern of greater strength in the abducted position of 60 degrees. Internal relation strength peak torque and total work were greater than those of external rotation in every test positions.

  • PDF