• Title/Summary/Keyword: Cutting State

Search Result 265, Processing Time 0.025 seconds

Standardization of Preparation of Chinese Cabbage Kimchi I. Effects of Dry Salting of Method Salt Content on the Texture of Kimchi (통배추김치 제조의 표준화 연구 I. 농도별 건염법이 배추 질감에 미치는 영향)

  • 정순애;오현희;전소현;최은정;김병미;조신호
    • The Korean Journal of Food And Nutrition
    • /
    • v.16 no.4
    • /
    • pp.423-429
    • /
    • 2003
  • Kimchi has been worldwide recognized as a traditional Korean fermented food, In the Chinese cabbage's pickling, salt content of evenly penetrate into the tissue affects on the texture of matured kimchi, But the previous method which usually using brine salting has a disadvantage of uneven penetration of salt into the leaves and stems. The purpose of the study is to develope the method which produce superior kimchi by evenly penetrate the salt into the tissue rapidly, The dry salting method is directly spread the salt on the surface of chinese cabbage as percentage in weight with 10, 12, 14, 16%(s) and pickled in this state for 5 hours. Brine salting method is soaking chinese cabbage in the 16% salt solution(16%B) for 20 hours. Sensory evaluation, contents of salt, properties of mechanical hardness and micro structure were studied among fresh cabbage, 16%B and 10, 12, 14, 16%(s) cabbage, The result of salt contents in all groups of pickled chinese cabbage were significantly increased compared with fresh cabbage. The compressive force of cabbage's steams by mechanical measurement was significantly decreased but cutting force was increased. In pickled cabbage, the cutting force was the highest correlated with salt content, In the sensory evaluation, the salty taste of leaves and chewy degree were significantly increased, but the hardness and crips of the stems were significantly decreased by increasing salt contents. Therefore the dry salting is the most excellent pickling method in small amount of kimchi production by saving salt amount and time, furthermore due to even penetration of salt into leaves and stems.

A Study for Failure Examples Including with Engine Oil Leakage, Poor Contact by Fin Damage and Vaporizer Inferiority on LPG Automotive (LPG 자동차의 엔진오일누설, 핀 손상에 의한 접촉불량, 베이퍼라이저 내부불량으로 인한 고장사례연구)

  • IL Kwon, Lee;Chang Ho, Kook;Sung Hoon, Ham;Seung Yong, Lee;Jae Gang, Lee;Seung Min, Han; Woo Chan, Hwang;Dae Cheon, Jang;Chang Bae, You;Jeong Ho, Lee
    • Journal of the Korean Institute of Gas
    • /
    • v.26 no.6
    • /
    • pp.24-29
    • /
    • 2022
  • This paper is a purpose to Analyze and study the failure examples for a engine oil leakage of camshaft bearing seal, poor contact by computer connector fin damage and vaporizer inferiority on LPG automotive. The first example, when the researcher disassembled the cylinder head of engine to establish the cause for oil leakage, he confirmed the engine oil leakage by damaged between the engine intake camshaft bearing and seal part. The second example, the connector fin of power source line that control the starting of a car supplied with engine computer. As a result, it found the fact that the engine operation stopped because of cutting of the power source by connector fin damage. The third example, it verified the engine incongruity phe cutting of the power source by connector fin damage. The third example, it verified the engine incongruity phenomenon as thd gas didn't flow the vaporizer by foreign substance deposit. Finally, it supplied a small quantity gas from vaporizer to mix. As the computer controlling mix opening condition supplied a air as opening signal, the air and fuel became rarefied state. it knew that the engine didn't produce prpper power. Therefore, a car have to throughtly inspect not in order to arise the failure symptoms.

A FUNDAMENTAL STUDY TO DEVELOP STANDARD TECHNOLOGY CRITERIA FOR IT-CONSTRUCTION FUSION TECHNOLOGIES, TO BE APPLIED TO A U-CITY

  • Kyoon-Tai Kim;Jae-Goo Han;Chang-Han Kim
    • International conference on construction engineering and project management
    • /
    • 2009.05a
    • /
    • pp.1352-1358
    • /
    • 2009
  • As the demand for a convergence between construction technologies and IT is on the rise, as seen in the visualization of U-City construction, studies on the ways in which IT in should be utilized in the building and construction field have been continuously and actively performed. However, there has been almost no development of standardized technology criteria relating to the life cycle of a building (planning, design, construction, and maintenance). That is, there are almost no examples of efforts made to combine construction technology and IT in a fundamental way, considering the environment, the facility, its spatial characteristics, engineering, materials, and structure, aspects that are commonly required not only for interior spaces but also for exterior construction of U-City. Despite the fact that a state-of-the-art infrastructure has been built, and the competency of users with the cutting-edge technology, composite studies on technologies, facilities, services and spaces are still lacking, and basic research on the composite operation method including compatibility and linkage between facilities and services within a U-City has been insufficient as well. It is generally known that by fusing IT with construction technologies, the total period of construction taken can be reduced and construction expenses can be curtailed, while construction quality can be improved. For this reason, it is vital to prepare a standardized base to connect cutting-edge IT with the construction technologies. In preparing such a base, the most urgent issue is to develop standardized technology criteria. The ultimate objective of this research is to establish the technological criteria system required to apply construction-IT fused technologies to U-Cities, and to develop the technological criteria for the design, construction and maintenance of the U-Cities. This paper, whose objective is to establish development strategies for construction-IT fused technologies by way of analyzing the criteria for conventional construction projects, the necessity of criteria for construction-IT fused technologies, and the current status of U-Cities' development, is the underlying research for this purpose. The strategies established are expected to be utilized in establishing the system of criteria for construction-IT fused technologies, and to contribute to a knowledge base in the construction-IT field. In addition, based on the strategies established, criteria for construction-IT fused technologies, such as design criteria and construction standards, will be developed, and by applying these criteria and standards, the ultimate objectives of U-Cities, which are the enhancement of urban competitiveness and the satisfaction of residents, will be attained

  • PDF

A Study on Estimate for Error and Convergence of Membrane Structures According to the Nonlinear Form-finding Techniques (비선형 형상 탐색 기법에 따른 막구조물의 오차와 수렴성 평가에 관한 연구)

  • Shon, Su-Deok;Kim, Seung-Deog;Jeong, Eul-Seok;Jeon, Jin-Hyung
    • Journal of Korean Association for Spatial Structures
    • /
    • v.7 no.3 s.25
    • /
    • pp.57-66
    • /
    • 2007
  • The membrane structures, a kind of lightweight soft structural system, are used for spatial structures. The material property of the membrane has strong axial stiffness, but little bending stiffness. The design procedure of membrane structures are needed to do shape finding, stress-deformation analysis and cutting pattern generation. In shape finding, membrane structures are unstable structures initially. These soft structures need to be introduced initial stresses because of its initial unstable state, and happen large deformation phenomenon. Therefore, in this paper, we investigate the convergence of solution and the speed according to the control variables and the method of shape analysis.

  • PDF

A Study of 'Asymmetry Triangle-Gusset' with Shirts [Jeoksam and Hansam] in the Early Days of Joseon Dynasty ('비대칭 접음 삼각 무' 적삼·한삼에 대한 고찰)

  • Jin, Deok Soon;Kim, Jin Kyung;Song, Mi-Kyung
    • Journal of the Korean Society of Costume
    • /
    • v.63 no.8
    • /
    • pp.76-89
    • /
    • 2013
  • This study is about 'asymmetry triangle-Mu' Jeoksam and Hansam in the early days of Joseon Dynasty. A study was done regarding the records of Jeoksam and Hansam in literature, the present state of the excavated 'asymmetry triangle-Mu' clothing Jeoksam and Hansam, and finally a deduction of the reason for the appearance of the 'asymmetry triangle-Mu' clothing Jeoksam and Hansam. The width of front length of 'asymmetry triangle-Mu' clothing in the early days of Joseon Dynasty is 29.5~35 cm and the width of one breath of the sleeve is 29.5~35 cm. The width of 'asymmetry triangle-Mu' is 9.5~16 cm and it is relatively big. Comparing to the width of one breath of the sleeve, it is almost 1:2.2~3.6 ratio. Therefore, when the sleeve was cut, the Mu was linked in order to save fabric the gusset of sleeve had to be folded and turned, and finally it became asymmetric. As a result of the above consideration, since the width of upper garments of $16{\sim}17^{th}$ century was big, the wearing of short tops of Jeoksam or Hansam without side vent as a small 'triangle-Mu' was uncomfortable. Because of this reason, the size had no option but to become bigger. So, during the $16^{th}$ and $17^{th}$ century, a period where mass production of fabric was difficult, the 'asymmetry triangle-Mu' type was considered to be a reasonable cutting method. After the middle of $17^{th}$ century, it can be estimated that 'asymmetry triangle-Mu' clothing disappeared according to the narrow aspect of clothing type.

A Study on a Wind Turbine Data Logger System based on WiFi for Meteorological Resource Measurement (기상자원 측정을 위한 와이파이 기반의 풍력용 데이터로거 시스템에 관한 연구)

  • Jung, Se-Hoon;Sim, Chun-Bo
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.10 no.1
    • /
    • pp.55-64
    • /
    • 2015
  • Wind turbine market is showed height growth rate of about 30% for year, and is increasingly growing. Total rate of domestic wind turbine installation is showing share of 0.2% of the global market that is 380MW. However, wind turbine installed in domestic are foreign product more than 90%. Similarly, Datalogger of pretest system for ocean wind turbine plant installation has been leaked huge cost to abroad by mostly abroad company product. In this paper, we proposed pretest weather resource measurement system for efficiency and investment cost cutting of wind turbine construction work. Preset weather resource measurement system is ocean weather resource measurement datalogger based on wireless communication(wifi) that have consist of hardware and software(wind rose) that is able to monitoring as datalogger of wireless bridge and battery state, wind direction, wind speed, temperature, humidity, radiation around weather tower and is able to analysis of measured data.

A Case Study on Reinforcement of Slope in PAP Retaining Wall using Back Analysis (PAP옹벽에서 역해석을 이용한 사면보강 사례 연구)

  • Kim, Jang-Deuk;Kim, Yong-Ha
    • The Journal of Engineering Geology
    • /
    • v.19 no.3
    • /
    • pp.345-350
    • /
    • 2009
  • The endpoint of the Yangbuk tunnel constructed at the national road between Gyeongju and Gampo is composed of massive cutting because the road is driven through the sides of mountain. PAP(Prestressed Anchor and PC Pannel) retaining wall as a slope stability method was established over this section. Part of the anchor in PAP wall became broken after six months. We performed inverse analysis through its measurements obtained until that time. An geological investigation to confirm the condition of ground layering and the attraction force test to find as to whether some errors might be present in the anchor were made. According to the back analysis, it was turned out that the value with soil parameter 90% that was applied to the original design was pertinent. In the redesign, the permissible stress in the anchor body was changed from 306 kN to 591 kN and 784 kN and the fixation position was increased from 11.0 m to 23.0 m. Nevertheless, five months have passed since the exchange of the anchor, the measurement results validate that stable state has been maintained. This research is considered a case that the immediate maintenance helps prevent the slope accidents.

Development of Electrical Resistivity Survey System for Geotechnical Centrifuge Modeling (원심모형실험을 위한 전기비저항 탐사 시스템 구축)

  • Cho, Hyung-Ik;Bang, Eun-Seok;Yi, Myeong-Jong;Choo, Yun-Wook;Kim, Dong-Soo
    • Journal of the Korean Geotechnical Society
    • /
    • v.30 no.10
    • /
    • pp.19-31
    • /
    • 2014
  • In order to investigate ground state change visually in physical model during centrifuge testing, electrical resistivity survey was adopted. Commercial resistivity survey equipment verified at various in-situ sites was utilized. The resistivity survey equipment installed in centrifuge facility was remotely controlled through intranet and electrical resistivity images obtained while centrifuge testing was being checked by real-time inversion. To verify the stable operation of the developed resistivity survey system, preliminary tests were conducted. Model ground was uniformly constructed using unsaturated soil and saline water was dropped on the ground surface to simulate contaminant flow situation. During the 10 g centrifuge tests, electrical resistivity was continuously detected and the testing results were compared with those of identically carried out 1 g centrifuge tests. In addition, the electrical resistivity was directly measured immediately after the centrifuge test by open cutting the model. Finally, reliability of electrical resistivity survey in the centrifuge test was verified by comparing those testing results.

A Study on the Actual Condition for Air Respirators Using Air-breathing (공기호흡기용 압축공기 시스템에 대한 실태 연구)

  • Lee Chang-Woo;Lee Young-Jae;Hyun Seong-Ho;Seong Jae-Man;Song Yun-Suk;Choi Don-Muk;Yoon Myung-O
    • Fire Science and Engineering
    • /
    • v.18 no.4
    • /
    • pp.16-21
    • /
    • 2004
  • This paper has investigated influences of pollutants in air-breathing on the respirators and it by year of disused air respirators that fire fighter is using in domestic cutting done air respirators after collection observed state of cylinder material through instrumental analysis, and cut open pipe to confirm pollution degree of pipe from cylinder of air respirators to airline mask and confirm pollution availability. The metal surface inside the air respirators was corroded by moisture included in the compressed air. The material generated by corrosion is white powder of less then 100㎛, which is analyzed as aluminum hydroxide corroded by moisture. This aluminum hydroxide powder may get into the lung while one breathes in, and it is easy to be attached to the lung so it will cause a serious influences to human health. This study suggests that Korea should set out the standards for components and composition of breathing air as soon as possible.

The Study on Hydraulic Model Experiment of Discharge Channel and Spillway (여수토 방수로의 수리모형검시에 관한 연구)

  • 김시원
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.8 no.2
    • /
    • pp.1124-1140
    • /
    • 1966
  • 'This hydraulic experiment have been practised Juk an Reservoir spillway and discharge 'channel which the province Kyong Buk was constructed and designed U. hook, for seizing all state of hydraulic. As result of the experimellt planning and making the model test, it has gained the necessary data at the amendment, projection of the most rational and economical result. 1. Project (1) Experiment project....1/30 of the discharge (2) project flood....0.01945 $m^3$/sec (rapidly) 2. Design Experiment It were sighted the water level for the nine point (L. & R. sides of No. O, L. & R. of No.1, L. side of NO.2, NO.3, No. 4 and NO.5), but it appeared each other that the lowest water level was 0.63 m at spillway (No.5) and the highest water level 0.735m less than planning water level O.75 m at No. 0. It was regarded as the phenomena appearing the difference from the calculation of the rational formular and coefficient of discharge. 3. Experiment examine E. ${\circled1}$ As a table (2) it had not a difference in comparision with design and was some lower value than design experiment's. E ..${\circled2}$) !twas same table (3) in a consequence of Experiment contracted Rocky cutting. E.${\circled3}$. ${\circled4}$ It was done amend.ment Experiment by elevating G.H. in only control point, but was not sure result as a table (2)(3)(4), and so it was changed largely in ${\circled5}$ Experiment. E. ${\circled5}$ Increasing water level was understanded to be proportion to $V^2$ in consideration of centrifugal force in the curve part and showed velocity contracting in curve the effect order's being regular in consequence of 1/6 sloped extending G.H. attached from 5 No. 0 to 1. 50 m, to S No. 0+5m. (S; discharge channel number).

  • PDF