• Title/Summary/Keyword: Cut-on condition

Search Result 560, Processing Time 0.022 seconds

Study on the measurement of blasting vibration response in construction a subway station at East gate of cultural treasure (지하철건설에 따른 문화재 보호와 동대문역사시공 보고서(1))

  • Choi, Sang-Yol;Ree, Soo-Book;Huh, Ginn;Chai, Soo-Yun
    • Journal of the Korean Professional Engineers Association
    • /
    • v.17 no.3
    • /
    • pp.32-49
    • /
    • 1984
  • The East gate station area is 205M long and 24m deep which is located 13 meter in front of cultural treasure east gate. The area to be excavated by blasting is composed of granite rocks from 10M depth to 25M. Surface earth extends to up 10M depth. This job site has in involves heavy traffic congestion such as over 10,000 cars passing in rush hour where clossing No 1 lint of subway running 3 minitues head way. This east gate station construction is to be executed for the provent of the setting down of underground level and blasting vibration effects to cultural treasure east gate. Therefore, the caltural treasure committee approved this execution subject to the following condition. 1. Subway gelogical foundation and measured natural frequency 2. Execution of water tight wall 3. Sellection and test of damping material for wall and under rail 4. Measurement of monitoring system during the execution 5. Measurement of histogram system The above two projects was carried out by Dr. Kwang team in KAIST and prof, Han in Hanyang University under accadamic study contract. In the blasting work, for the pourpose of reduced vibration and low explosion velocity such as CCR, Kovex slurry. The 2nd, used electrical caps shall be delay cap and M/S caps in multi delay. The 3rd, drilling pattern is bench cut in open cut and applied control blasting in tunnelling and also shall drill anti-vibration holes as line drilling.

  • PDF

A case study on perforation under Daejeon station building by Front-Jacking method (Front-Jacking공법에 의한 대전역사 하부 관통사례)

  • Kim, Yong-Il;Hwang, Nak-Yeon;Jeong, Du-Seok;Cha, Jong-Hwi;Lee, Nae-Yong
    • Proceedings of the Korean Society for Rock Mechanics Conference
    • /
    • 2006.03a
    • /
    • pp.195-203
    • /
    • 2006
  • The crossing construction under railroad have two methods which are cut and cover and trenchless method. first, cut and cover method is an extremely limited method concerning non-running time. Whereas, trenchless method is free from restriction such as train speed and running time, and has the strong points of safe and rapid construction. Front Jacking method, one of the trenchless methods, is frequently applied recently due to its stability during construction and vantage of assuring schedule reliability. The procedure is that after minimizing interlocking friction with structure and earth pressure due to jacking the small steel tube, pulling the precast box manufactured at the field in the ground using PC strand and hydraulic Jack. This method is able to be applied regardless of section size and length of box and condition of ground. And that is also pro-environmental. This paper presents the case of Daejeon E. W. perforate Road Project applied with the Front Jacking method.

  • PDF

A Case Study on Construction of Front-Jacking method in Daejeon E.W. perforate Road Project (대전 동서관통도로 Front-Jacking공법 시공사례)

  • Kim Yong-Il;Hwang Nak-Yeon;Cha Jong-Whi;Jang Sung-Wook;Lee Nai-Yong
    • Proceedings of the KSR Conference
    • /
    • 2005.05a
    • /
    • pp.646-654
    • /
    • 2005
  • The crossing construction under railroad have two methods which are cut and cover and trenchless method. First, cut and cover method is an extremely limited method concerning non-running time. Whereas, trenchless method is free from restriction such as train speed and running time, and has the strong points of safe and rapid construction. Front Jacking method, one of the trenchless methods, is frequently applied recently due to its stability during construction and vantage of assuring schedule reliability. The procedure is that after minimizing interlocking friction with structure and earth pressure due to jacking the small steel tube, pulling the precast box manufactured at the field in the ground using PC strand and hydraulic Jack. This method is able to be applied regardless of section size and length of box and condition of soil. And that is also pro-environmental. This paper presents the case of Daejeon E. W. perforate Road Project applied with the Front Jacking method.

  • PDF

Comparison Analysis of Factor of Safety on Rock Slope in Boeun Region Using Distinct Element Method and Limit Equilibrium Method (개별요소법과 한계평형법을 이용한 보은지역 암반사면 안전율 비교해석)

  • 이지수;유광호;박혁진;민경덕
    • Journal of the Korean Geotechnical Society
    • /
    • v.19 no.4
    • /
    • pp.33-41
    • /
    • 2003
  • The large planar failure has occurred in a rock cut slope of highway construction site in Boeun. This area is considered to be unstable since the discontinuity, whose orientation is similar to the orientation of the failure plane, is observed in many areas. Therefore, several analysis techniques such as SMR, stereographic analysis, limit equilibrium, numerical analysis, which are commonly used in rock slope stability analysis, are adopted in this area. In order to analyze the stress redistribution and nonlinear displacement caused by cut, which are not able to be obtained in limit equilibrium method, DEM and shear strength reduction technique were used in this study. Then the factors of safety evaluated by shear strength reduction technique and limit equilibrium were compared. In addition, the factor of safety under fully saturated slope condition was calculated and subsequently, the effect of the reinforcement was evaluated.

Transcutaneous Oxygen Pressure to Predict Wound Healing in Mild Diabetic Feet (경증의 당뇨발에서 창상치유 예측인자로서의 경피산소분압치)

  • Jang, Seo-Yoon;Jeong, Tae-Won;Han, Seung-Kyu;Kim, Woo-Kyung
    • Archives of Plastic Surgery
    • /
    • v.38 no.5
    • /
    • pp.585-589
    • /
    • 2011
  • Purpose: Microcirculation of diabetic patients is commonly comporomised, regardless of the condition of the macrocirculation. Therefore, direct tissue oxygenation measurement is recommended in determining tissue viability and predicting wound healing potential. This study was designed to determine cut-off value of the tissue oxygenation in predicting wound healing in diabetic foot patients. Methods: This study included 41 feet of 41 diabetic foot patients who were treated in the Diabetic Wound Center of author's institution between January and June, 2009. Main inclusion criteria were type 1 or 2 diabetes and a foot ulcer (duration > 3 weeks) and ulcer area (from 1 $cm^2$ to 4 $cm^2$). Measurements of the area of diabetic foot ulcer were carried out before treatment. Transcutaneous oxygen pressure ($TcpO_2$) was measured at adjacent site of ulcer. The healing wound was defined as complete wound closure within 12 weeks. Results: Average diabetic foot ulcer areas with healing and nonhealing wounds were $2.67{\pm}0.76$ and $2.59{\pm}0.75\;cm^2$, respectively. There was no significant difference in the wound area between the groups. Average foot $TcpO_2$ in healing and nonhealing wounds were $68.56{\pm}23.07$ and $30.98{\pm}16.66$ mmHg, respectively ($p$ <0.01). The rate of healing wound increased as $TcpO_2$ increased. In particular, $TcpO_2$ lower than 40 mmHg and higher than 40 mmHg showed the most significant difference (wound healing rates of 25% and 71%, respectively). Conclusion: Based on the results of the study, the minimal $TcpO_2$ value thought to be required for adequate wound healing in diabetic wounds (cut-off value) is 40 mmHg.

Evaluation of Validity of Deficiency and Excess Pattern Identification Questionnaire (검진용 허실 변증 진단 설문지 타당도 평가)

  • Baek, Younghwa;Jung, Kyungsik;Kim, Yunyoung;Jang, Eunsu
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.34 no.3
    • /
    • pp.142-148
    • /
    • 2020
  • The purpose of this study was to evaluate the validity of Deficiency and Excess Pattern Identification Questionnaire. The number of subjects enrolled in this study was 431. Pearson Correlation Coefficient analysis were conducted to reveal the correlation among Deficiency and Excess Pattern Identification Questionnaire, Grip Strength and Quality of life. ROC-curve analysis were used to suggest optimal cut off value. Cohen Kappa also used to analyze for diagnostic validity. The significant p-value was < .05. The Deficiency questionnaire had positive correlation with the score of the expert and negative correlation with Grip Strength and Quality of life (p<.001). The Excess questionnaire had positive correlation with the score of the expert and negative correlation with Quality of life (p<.001). The optimal cut off value was 56.5 to separate deficiency and non deficiency and 47.5 to separate excess and non-excess. Furthermore, AUC was .900 and .851 accordingly. Cohen Kappa value between deficiency questionnaire and the expert was .640. Cohen Kappa value between excess questionnaire and the expert was .513. This study reveals that Deficiency and Excess Pattern Identification Questionnaire is valid. However, further study considering of gender, age, and health condition and so on, is needed.

Mechanical behaviour of rib-reinforced precast tunnel liner according to variable rib-reinforcement shapes (프리캐스트 터널 Liner의 리브보강 형상변화에 따른 역학적 거동 특성)

  • Lee, Gyu-Phil;Lee, Seong-Won;Hwang, Jae-Hong
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.11 no.3
    • /
    • pp.265-275
    • /
    • 2009
  • Due to the limitation of construction efficiency and structural safety, the application of the high covering and wide width tunnels was limited prior to the introduction of precast rut and cover tunnels. Therefore, a cut and cover tunnel structure with rib reinforcement is proposed to mechanically improve the safety on condition of high covering and wide width tunnel. Therefore, a technical problem that can provide a response similar to the actual filling conditions is analyzed by the finite element analyses, moreover, the mechanical behaviour of developed rib-reinforced precast tunnel liner through a large-sized model test will be investigated. The ultimate load of the developed rib-reinforced precast tunnel liner shows a 3% reduction compared to existing rib-reinforced precast tunnel liner, especially, the section of rib-reinforcement decreased to 55% compared to it of existing. Therefore, the stability of tunnel structure can be significantly improved through the developed rib-reinforced precast segment.

Effect of Cutting Fluid on the Metal-Cutting Mechanism (절삭유제가 금속절삭기구에 미치는 영향에 관한 연구)

  • Seo, Nam-Seob
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.2 no.2
    • /
    • pp.69-75
    • /
    • 1985
  • The object of this study is to discuss the effect of cutting fluid on the mechanism of chip formation in orthogonal cutting. Rehbinder effect has been known as a phenomenon, the reduction of mechanical strength, when the metal is exposed in a polar organic environment or the surface of metal is coated with some polar organic substances. About the cause of Rehbinder effect there have been many different ideas by Rehbinder, Merchant, Shaw, Sakakida and etc. In this report, the effects of surface active medium (magic ink) upon the mechanism of chip formation on the orthogonal cutting of copper and the mechanical properties of the work material are experimentally discussed with constant rake angle. Under the condition of polar organic environment the experimental results are as follows; 1) The chip thickness becomes thinner and slip line pitch on the free surface of chip becomes smaller than that of dried cutting area. 2) The order of alternation of cutting ratio was changed. 3) The friction angle on the tool face is not affected by the depth of cut. 4) The cutting force and shear strain on the shear plane decrease remarkably, therefore the work material must be embrittled under polar organic environment.

  • PDF

Analysis on the Dielectric Characteristics of Dry Air According to Pressures for Developing an Eco-friendly High Voltage Switchgear (친환경 고압배전반 개발을 위한 dry air의 압력별 절연내력특성 분석에 관한 연구)

  • Nam, Seok-Ho;Kang, Hyoung-Ku
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.8
    • /
    • pp.1560-1565
    • /
    • 2011
  • The environmental pollution caused by green-house gases such as $CO_2$ and $SF_6$ has been becoming the main issue of industrial society. Many developed countries are making efforts to minimize the amount of $CO_2$ emission come from the operation of high voltage electrical apparatuses. As a part of these efforts, 180 countries signed the Kyoto Protocol in 1997 to cut back on their green-house gas emissions. Nowadays, the study on the development of dry air insulated switchgear (DAIS) which is known as an eco-friendly electrical apparatus is in progress. A DAIS is advantageous for minimizing the effect of impurities and enhancing the dielectric characteristics over an air insulated switchgear (AIS) by applying constant pressure to an enclosed cubicle. Therefore, a study on the electrical insulation performance of dry air as a gaseous insulation medium is conducted in this paper to substitute a gas insulated switchgear (GIS) for DAIS. As results, it is verified that the AC dielectric characteristics of dry air are similar to those of air and the lightning impulse dielectric characteristics of dry air are superior to those of air at 1bar pressure condition. However, dry air is of inferior dielectric characteristics to $SF_6$ at 4bar pressure condition. Finally, it is suggested that the internal pressure of DAIS should be over 4bar pressure to develop a high voltage switchgear which has similar electrical performance to a conventional GIS. Also, the empirical formulae on calculating the maximum electric field intensity at sparkover of dry air are deduced by experiments according to pressures. It is expected that these results are helpful to design and develop a high voltage electrical apparatus.

A Study on the Machining Characteristics of Prototype of Roller Gear Cams (롤러 기어 캠의 시제품 가공특성에 관한 연구)

  • Kim, Jin-Su;Kang, Seong-Ki;Lee, Dong-Seop
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.11 no.5
    • /
    • pp.60-67
    • /
    • 2012
  • In the study, the effect grinding condition on the workpiece arithmetical average roughness(Ra) to 10 steps leading to cutting each section with the spindle rotational speed 8000rpm and feed rate 150mm/min of grinding in GC(green silicon carbide) grinding processing after heat treatment and non heat treatment of SCM415 material. Also the following conclusions were obtained analysis of stress distribution displacement and finite elements method(FEM) on assemble parts with 3+2 axis simultaneous control through grinding and gave a load 11kg on ATC arm both sides gave a load of 11kg. For the centerline average roughness(Ra) in the heat and non-heat treatment work pieces, which were appeared the most favorable in the fifth section were $0.511{\mu}m$ and $0.514{\mu}m$, that were shown in the near the straight line section was the smallest deformation of curve. In addition, the bad surface roughness appeared on the path is too long by changing angle, the more inclined depth of cut, because the chip discharging is not smoothly.