• Title/Summary/Keyword: Cut out switch

Search Result 22, Processing Time 0.028 seconds

The Research for a Structure of Current Limiter using a Phasic Similitude of Magnetic Circuit (자기회로의 위상학적 상사성을 이용한 전류제한기 구조에 관한 연구)

  • Ji, Geun-Yang;Min, Kyung-Il;Lee, Su-Won;Jang, Bong-Hwan;Moon, Young-Hyun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.11
    • /
    • pp.2128-2135
    • /
    • 2009
  • In this paper, current limiter using a magnetic switching which is based on magnetic flux change in the case of fault is proposed. This current limiter consists of iron-core and three parts of coils. One is the primary coil connected to the power system. Another is the secondary coil wound to the opposite direction of the primary coil's winding. The other is the secondary of the secondary coil which is a movable copper plate winding and located below the secondary coil. In the normal state, the magnetic flux produced in the primary and secondary coils flows to the opposite directions each other and becomes to be canceled out. Therefore the voltages induced between the coils are zero. In the case of a fault, at the moment of a fault occurrence recognition, the switch connected to a secondary coil is opened and the secondary of the secondary coil is pulled out to the outside of the iron-core. Then, magnetic flux becomes to flow through the iron-core. Accordingly, the voltage is induced between the both ends of the primary coil and makes the current reduced. Therefore it is possible to cut off the circuit breaker easily with the proposed current limiter. This paper analyzes the current limiting effects and the detailed results are given.

A Study on the DC Leakage Current Test for Power Cable of Private Electrical Facilities considering Lightning Arrester (피뢰기를 고려한 자가용 전기설비 인입선로의 직류누설전류시험에 관한 연구)

  • Jeong, Ki-Seok;Gil, Hyoung-Jun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.1
    • /
    • pp.142-147
    • /
    • 2018
  • Private electrical facilities are judged whether it is suitable for the insulation aging condition of their incoming underground cables using DC leakage current test method. In the case where the service point of utility is the secondary side of cut out switch installed in the electric pole, there is a problem that it is difficult to separate the lightning arresters(LA) because of their high position of the pole. Therefore, the field test voltage is applied at value lower than DC 30 kV, which are stated in the inspection guideline. However, this test could reduced the insulation performance of the LA by accelerating the electrical stress of the metal oxide varistor element in the pre-breakdown region. In this study, we analyzed the relationship between the DC test voltage and the leakage current using the non-destructive DC high voltage equipment with leakage current measurement function. The results show that the leakage current increases sharply above the specified test voltage. As a consequence, it could be contributed to improve insulation aging inspection method by selecting the possible test area on the VI characteristic curve of the pre-breakdown area of the LA.

Reactive Silencer Design for Suppressing Impulse Noise from a High Voltage Cut Out Switch Fuse (고전압 COS 퓨즈로부터 방사된 충격성 소음 저감용 반사형 소음기의 설계)

  • Song, Hwa-Young;Kim, Deok-Han;Lee, Jong-Suk;Lee, Dong-Hoon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.951-954
    • /
    • 2006
  • This Study introduces the design of a reactive type silencer for reducing impulse noises emitted from a high voltage COS fuse of a transformer. When a high voltage COS fuse becomes a short circuit by the over current, the peak sound pressure level above 150dB(A) is generated at the distance of 2m from a COS Fuse. For the purpose of the reduction of impulse noise, in this study. the reactive type silencers have been utilized. The performance of noise reduction for them can be expressed by insertion loss. The reactive silencers have been tested for 23 different types with each different porosity, hole diameter and depth. From the experimental results, it is found that the reactive silencer has an excellent performance to greatly suppress the impulse noise. The one-stage, two-stage and three-stage reactive type silencers have been shown to have the insertion losses of about from 35dB (A) to 25dB(A).

  • PDF

Development of the Automatic Inlet (자동물꼬의 개발)

  • 정하우;이남호;김성준;최진용;한형근;김대식
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.37 no.1
    • /
    • pp.49-54
    • /
    • 1995
  • Three types of floating-type automatic inlet were developed for the purpose of reduc- ing farmer's working hours required for water management and saving irrigation water. The point of automation is to use a float within the inlet which is floated and sinked by the ponding depth of paddy field, Thus opens and closes the control gate of irrigation. Suitability of each inlet may depend on production cost, applicability to paddy field condi- tions, and feasibility to farmers, etc. The first model was composed of three parts : chamber for irrigation control gate, chamber for float controlled by ponding depth, and connection bar between the two parts. It was designed to open and close the control gate gradually as the ponding depth drops and rises to a certain level. The second model was designed to improve the weak point of the first model which is the imperfect-closing of gate when it approaches to the end of ir- rigation. A switch-spring was equipped above the connection bar for perfect opening and closing of gate when the ponding depth reaches to a certain level. The third model was designed by combining the two chambers, that is, cut in halves the inlet volume of the above two models. Magnets were equipped above the float for perfect opening and closing gate. The functional experiment for three developed inlets was successfully carried out and the rating curves were derived.

  • PDF

Optimum Design of High Voltage Fuse Holder with a Built-in Acoustic Absorber System (흡음장치를 내장한 고전압 퓨즈홀더의 최적설계에 관한 연구)

  • Jin, Yeung-Jun;Lee, Hae-Won;Hwang, Yu-Sub
    • Journal of the Korean Society of Safety
    • /
    • v.26 no.1
    • /
    • pp.8-14
    • /
    • 2011
  • Noise and vibration are likely to disturb the sensory system of human body leading to psychological stress and thereby property damage. In this research, a cut out switch(COS) with a built-in acoustic absorber along with a COS fuse broken was developed to reduce percussion noise. This new system is based on a design approach that combines existing absorber systems: expansion type, resonator type, and acoustic absorber type silencer The noise performance of the new system was simulated using the $SYSNOISE^{TM}$ software under optimized parameters: the diameter of perforated plate 2 mm, the plate thickness 3 mm, the width of expansion room 25 mm, the impinging vortex room 14 mm, and the noise absorbtion room 10 mm. The results showed that it reduced noise by approximately 41.1 dB compared to the current systems available in the market. Furthermore, it showed reduced noise by approximately 12 dB more than a product with an acoustic absorber of the Fault Tamer(USA).

A study on AC over-current breaker using thyristor (Thyristor를 이용한 교류과전류 차단에 관한 연구)

  • 박민호;심재명
    • 전기의세계
    • /
    • v.28 no.7
    • /
    • pp.49-55
    • /
    • 1979
  • This paper describes the mechanisms which breaks A.C. over-current protection in low voltage load. For the high speed over-current protection, it consists of thyristor switching circuit by forced commutation, IC logic gate controlled circuit and over-current detector with reed switch. Under various duty conditions, breacker was carried out several experiments and discussions. The results are as follows; (1) over-current cut off is possible within a quarter cycle (4ms at 60Hz) and clear is at least ten times faster than its electromechanical equivalent. (2) as the forced commutation thyristor circuit breaker has capability of high speed break, equivalent surgy current capacity of switching thyristor is increased more than twenty times of its rated current. (3) breaker using solid state dose not produce any harmful arc during switching period. Therefore the breaker above described may be considered an effective over-current protector for soli state power devices in industrial applications.

  • PDF

An Experimental Study on the Propagation Characteristics and Reduction of Impulse Noises from a High Voltage COS Fuse (고전압 COS 퓨즈로부터 방사된 충격성 소음의 전파특성과 저감에 관한 실험적 연구)

  • Song, Hwa-Young;Ju, Kyung-Min;Lee, Dong-Hoon;Kang, Rae-Goog;Jung, Nak-Hun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.71-74
    • /
    • 2005
  • This experimental study describes the propagation characteristics and reduction of impulse noises emitted from a high voltage COS(Cut Out Switch) fuse of a transformer. When a high voltage COS fuse becomes a short circuit by the over current. The peak sound Pressure above 150dB(A) is generated. In this study, an impulse noise generator is designed for generating the impulse noises similar to the noise level of COS fuse, which is utilized to test the noise reduction of a reactive silencer. The reactive silencers have been tested for 10 different types with each different porosity, hole diameter and length. From the experimental results, it is found that the reactive silencer has an excellent performance to greatly suppress the impulse noise and that its performance is closely connected with the porosity and hole diameter.

  • PDF

Development of a 3-D Immersion Type Training Simulator

  • Jung, Young-Beom;Park, Chang-Hyun;Jang, Gil-Soo
    • KIEE International Transactions on Power Engineering
    • /
    • v.4A no.4
    • /
    • pp.171-177
    • /
    • 2004
  • In the current age of the information oriented society in which we live, many people use PCs and are dependant on the databases provided by the network server. However, online data can be missed during the occurrence of a blackout and furthermore, power failure can greatly effect Power Quality. This has resulted in the trend of using interruption-free live-line work when trouble occurs in a power system. However, 83% of the population receives an electric shock experience when a laborer is performing interruption-free live-line work. In the interruption-free method, education and training problems have been pinpointed. However, there are few instructors to implement the necessary training. Furthermore, the trainees undergo only a short training period of just 4 weeks. In this paper, to develop a method with no restrictions on time and place and to ensure a reduction in the misuse of materials, immersion type virtual reality (or environment) technology is used. The users of a 3D immersion type VR training system can interact with the system by performing the equivalent action in a safe environment. Thus, it can be valuable to apply this training system to such dangerous work as 'Interruption-free live-line work exchanging COS (Cut-Out-Switch)'. In this program, the user carries out work according to instructions displayed through the window and speaker and cannot perform other tasks until each part of the task is completed in the proper sequence. The workers using this system can utilize their hands and viewpoint movement since they are in a real environment but the trainee cannot use all parts and senses of a real body with the current VR technology. Despite these weak points, when we consider the trends of improvement in electrical devices and communication technology, we can say that 3D graphic VR application has high potentiality.

3DImmersion Type Virtual Environment System : Training Interruption-free Live-Line Workers (무정전 활선작업 피교육자를 위한 3차원 몰입형 가상환경 교육시스템의 개발)

  • 정영범;박창현;김기현;장길수
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.53 no.1
    • /
    • pp.22-30
    • /
    • 2004
  • As an information-oriented society comes, many people use PC and depend on database that network server has. However, the online data can be missed when a blackout happens and also a power failure effects on standard of judgment on Power Quality. Thus, it is reason of a trend using interruption-free live-line work when a trouble happens to power system. However, the 83% among the number of people who receive an electric shock experience when a laborer is doing interruption-free live-line works. In interruption-free method, the education and the training problem has been issued. However, we have a few instructors for that training. Furthermore, the trainees have short training period, just 4 weeks. In this paper, to develope the method that has no restriction of a time and place and reduce the wasteful materials, immersion type virtual reality(or environment) technology is used. The users of a 3D immersion type VR training system can interact with the system by doing same action in the real safe environment. Thus, it can be valuable to apply this training system to a dangerous work like as "Interruption-free live-line work exchanging COS(Cut-Out-Switch)". In this program, the user works with a instruction on the window and speaker and can't work other tasks until each part of the task completed. The workers using this system can use their hands and viewpoint movement as he is in a real environment but the trainee can't use all parts and senses of a real body with the current VR technology. Despite of this weak point, when we consider the trends of improvement in electrical devices and communication technology, we can say that 3D graphic VR application has a high potentiality.

The 4-channel Multiple Contact Resistance Measurement Systems using MQTT Broker Server for AC 22.9 kV COS/Lightning Arrester (MQTT 브로커 서버를 이용한 AC 22.9 kV 차단기/피뢰기의 4-채널 다중 접촉저항 측정 시스템)

  • Ra-Yun Boo;Jung-Hun Choi;Myung-Eui Lee
    • Journal of Advanced Navigation Technology
    • /
    • v.27 no.2
    • /
    • pp.203-208
    • /
    • 2023
  • In this study, we propose a method to improve the precision of contact resistance measurement circuits using constant current method and voltage drop method, and implement a dashboard that monitors the measured data of contact resistance measurement systems through MQTT broker server. The contact resistance measurement system measures the resistance value and transmits the measured value to the MQTT broker server using wireless communications. This developed dashboard uses Node-RED and Node-RED-Dashboard to receive the resistance values of up to four contact resistance measurement systems and show them to user's monitor screen. Users can manage multiple measurement data using a single dashboard and easily interface with other devices through the MQTT broker server. Through the experimental results from real data measurements, the relative standard deviation about precision is improved to average 40.37% and maximum 64.73% respectively.