• 제목/요약/키워드: Customer Electric System

검색결과 154건 처리시간 0.031초

Development of Value-Added Service Systems Based on AMR Data in Power Industry

  • Kim, Sun-Ic;Jang, Moon-Jong;Oh, Do-Eun;Ko, Jong-Min;Yu, In-Hyeob;Lee, Jin-Ki;Yang, Won-Chul;Kim, Jin-Cheol
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2005년도 ICCAS
    • /
    • pp.1387-1390
    • /
    • 2005
  • Recently, foreign utilities emphasize the importance of the value-added services based on Information Technology(IT) as one of the strategic technologies for establishing a new power system in the future digital society. They develop many different types of the value-added services and apply the systems for customer. In domestic case, the data from the Automatic Meter Reading (AMR) System is used only for calculating the tariffs. Data from the AMR system can be strategic assets for utilities to provide the value-added services for customer. Development of the value-added services for utilities and customer needs processing and managing the AMR data. In this paper, the energy consulting service, which is adequate to new power system environment, is suggested for development of the value-added services. The application of the suggested service will bring the effect of reducing the monthly bill for customer. Also the service will give not only the effective demand side management(DSM) and load control, but also reduction of the investment for utilities.

  • PDF

Investigation and Analysis of Interruption Characteristics for Industrial Customers

  • Choi, Sang-Bong
    • 조명전기설비학회논문지
    • /
    • 제21권4호
    • /
    • pp.45-52
    • /
    • 2007
  • Electric power is an important element in any modern economy. The availability of a reliable power supply at a reasonable cost is important for the economic growth and development of a country. Electric power utilities throughout the world therefore strive to meet customer demands economically with high quality and reliability. As the power industry moves towards open competition, therefore, there has been a call for a methodology by which to evaluate power system reliability through the use of customer interruption characteristics. This paper presents the results of an investigation and analysis of interruption characteristics of an industrial customer in Korea. This study used a direct visit survey to determine the investigation and analysis of electric service quality and the characteristics of industrial customers in Korea. A customer survey conducted throughout Korea via personal interviews of 660 sample customers is presented here. Variation according to characteristics of interruption such as duration, time of day, frequency and day of interruption was also investigated

재폐로에 의한 수용가측의 영향 (Impact of auto-reclosing on Customer systems)

  • 임성정;오정환;김재철;김일동;한경남;김영한
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 B
    • /
    • pp.740-742
    • /
    • 1996
  • This paper analyzes the Impact of customer system at the transients due to auto-reclosing on 22.9kV distribution lines. The various factors affecting this phenomena are analyzed In detail through parametric studies. These factors Include the fault current, fault location, reclosing angle, capacitor bank size, and customer load characteristics. The impacts of these transients on customer system are described and available to identify the optimal auto-reclosing scheme.

  • PDF

수용가내부 고압배전시스템의 전력손실감소효과 (A Proposed High Voltage Distribution System of the Customer Inside for Reducing Power Loss)

  • 박형준;윤만수;정찬수
    • 조명전기설비학회논문지
    • /
    • 제19권5호
    • /
    • pp.39-44
    • /
    • 2005
  • 에너지절감은 요즈음과 같은 고유가의 시대의 전기 설비 분야의 주요 쟁점중 하나이다. 따라서 전력분야의 여러 기관에서 에너지절감과 관련된 방안과 연구가 진행되고 있는데, 본 논문에서는 전기공학의 기본적인 이론을 바탕으로 하여 중용량 이상의 전력 수용가 내부에서 배전시스템을 변경함으로써 전기에너지의 손실을 절감하는 방안을 제시하였다. 이는 고압의 수전전압을 저압으로 변환하여서 상당한 거리에 떨어져 있는 부하에 전력을 공급하는 일반적인 수용가 내부 배전시스템 대신에, 수전전압을 수용가내의 개별 수전단까지 직접 수전하고 여기서 저압으로 변환하는 것을 의미한다. 이와같은 시스템적인 변경을 통해서, 수용가내의 저압선로가 비교적 긴 아파트단지등에서 상당한 전력에너지의 절감효과를 기대할 수 있으리라 사료된다. 본 논문에서는 기존의 수용가내의 배전시스템과 제안한 배전시스템에서의 전압강하율과 선로전력손실을 비교하여 제안한 배전시스템의 효과를 계산하였다.

Development of Representative Curves for Classified Demand Patterns of the Electricity Customer

  • Yu, In-Hyeob;Lee, Jin-Ki;Ko, Jong-Min;Kim, Sun-Ic
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2005년도 ICCAS
    • /
    • pp.1379-1383
    • /
    • 2005
  • Introducing the market into the electricity industry lets the multiple participants get into new competition. These multiple participants of the market need new business strategies for providing value added services to customer. Therefore they need the accurate customer information about the electricity demand. Demand characteristic is the most important one for analyzing customer information. In this study load profile data, which can be collected through the Automatic Meter Reading System, are analyzed for getting demand patterns of customer. The load profile data include electricity demand in 15 minutes interval. An algorithm for clustering similar demand patterns is developed using the load profile data. As results of classification, customers are separated into several groups. And the representative curves for the groups are generated. The number of groups is automatically generated. And it depends on the threshold value for distance to separate groups. The demand characteristics of the groups are discussed. Also, the compositions of demand contracts and standard industrial classification in each group are presented. It is expected that the classified curves will be used for tariff design, load forecasting, load management and so on. Also it will be a good infrastructure for making a value added service related to electricity.

  • PDF

전력계통 고조파 유입 유출 분석에 관한 연구 (A Study on the Analysis of Harmonic Injection and Emission for Power System)

  • 왕용필;정종원;김세동;곽노홍;전영수;박상호
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2007년도 춘계학술대회 논문집
    • /
    • pp.203-205
    • /
    • 2007
  • A method is proposed in this paper to determine the harmonic contributions of a customer at the point of common coupling. The method can quantify customer and utility responsibilities for limit violations caused by either harmonic source changes or harmonic impedance changes. It can be implemented in current power quality monitors and digital revenue meters. The method is comparison of measurement phase angles between harmonic voltage and current. The proposed method has been applied to the test system. The study results have indicated the accuracy of harmonic injection and emission for customer and utility.

  • PDF

Home Energy Management System for Residential Customer: Present Status and Limitation

  • Lee, Sunguk;Park, Byungjoo
    • International Journal of Advanced Culture Technology
    • /
    • 제6권4호
    • /
    • pp.284-291
    • /
    • 2018
  • As environmental pollution has become worse green technologies to replace or reduce consumption of fossil fuel get spotlight from government, industry and academia globally. It is reported that 40% of carbon dioxide emission is caused by electricity power generation. And 37% of end user electricity power is used by residential costumer in US. Smart Grid is considered as one of promising technology to alleviate severe environmental problem. In residential environment, Home Energy Management System (HEMS) can play a key role for green smart home. The HEMS can give several benefits like aslowering electric utility bill, improvement of efficiency of electric power consumption and integration of generator using renewable energy resources. However just limited functions of HEMS can be used for residential customer in real life because of lack of smart function in home appliances and optimal managing software for HEMS. This study provides comprehensive analysis for Home Energy Management System for residential customer. Simple HEMS system with real products on the market are explained and limitation of current HEMS are also discussed.

새로운 수용가내의 배전시스템에 대한 연구 (A Study on the New Distribution System of the Customer Inside)

  • 박형준;권시현;이승환;정찬수
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2004년도 학술대회 논문집
    • /
    • pp.229-232
    • /
    • 2004
  • This paper is about the new Distribution System of the electric customers. The Power loss in the Distribution System is disregarded and rarely managed so far. But, economically, this loss is not small quantity to Ignore. So, in this paper, we suggest that the new Distribution System of the electric customer by simply changing the locations of Power Transformer and other power facilities which is located inside of the customer. And we also show that the Power loss is decreased with this systematic changing by approximated calculation.

  • PDF

기상센서를 이용한 지능형 직접부하제어 시스템 디자인 설계 (The Design of Direct Load Control System Using Weather Sensors)

  • 최상열
    • 한국위성정보통신학회논문지
    • /
    • 제10권4호
    • /
    • pp.113-116
    • /
    • 2015
  • 건물 외부에 설치된 각종 기상 측정센서에서 전송된 현재의 외부 기상조건과 일자별, 특수일별 건물 에너지 사용량과의 관계를 인공지능기법으로 분석하고 학습을 통한 예측기능을 갖도록 함으로써, 일자별, 특수일별, 계절별 그리고 기상조건에 따른 익일 전력 사용량을 예측하고 이에 따른 부하의 On/Off 우선순위를 결정하는 기능을 갖는 지능형 직접부하제어 시스템 구조를 설계한다.

CLUSTER ANALYSIS FOR REGION ELECTRIC LOAD FORECASTING SYSTEM

  • Park, Hong-Kyu;Kim, Young-Il;Park, Jin-Hyoung;Ryu, Keun-Ho
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2007년도 Proceedings of ISRS 2007
    • /
    • pp.591-593
    • /
    • 2007
  • This paper is to cluster the AMR (Automatic Meter Reading) data. The load survey system has been applied to record the power consumption of sampling the contract assortment in KEPRI AMR. The effect of the contract assortment change to the customer power consumption is determined by executing the clustering on the load survey results. We can supply the power to customer according to usage to the analysis cluster. The Korea a class of the electricity supply type is less than other country. Because of the Korea electricity markets exists one electricity provider. Need to further divide of electricity supply type for more efficient supply. We are found pattern that is different from supplied type to customer. Out experiment use the Clementine which data mining tools.

  • PDF