다회선 초음파 유량계를 이용한 거래용 오일유량 측정 (Custody Transfer Hydrocarbon Flow Measurement with Multi-path Ultrasonic Flow Measurement)

  • 황상윤;이호준;박기환
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2003년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.149-153
    • /
    • 2003
  • As the fastest growing flowmeter technology, multi-path ultrasonic flow-meters are gaining wider range in petroleum industry for liquid hydrocarbon custody transfer measurement. This paper describes the mult-path ultrasonic flowmeter, URO-Ex1000 the requirements necessary to prove and test in Korea & China. URO-Ex1000 haver a good results with accuracy range, but a little exceed with repeatability.

  • PDF

An Effective Architecture for Reliable Communications in VDTN

  • Morales, Mildred Madai Caballeros;Hong, Choong Seon
    • 한국정보처리학회:학술대회논문집
    • /
    • 한국정보처리학회 2010년도 추계학술발표대회
    • /
    • pp.1046-1049
    • /
    • 2010
  • Custody transfer method is often managed by the general architecture of Delay Tolerant Network (DTN) to provide reliability in the communications through storage and forward paradigm, but can be inefficient when the acknowledgment messages are lost, or the network becomes congested. In this paper we describe a new architecture that is particularly efficient for the custody transfer method. Because, it provides an additional control of acknowledgment messages, consolidate knowledge and services, using the advantage of the cross-over architectures and distribution control through local and global services.

Custody Transfer of Bundle layer in Security Mechanism for Under water Inter net of Things (UIoT)

  • Urunov, Khamdamboy;Namgung, Jung-Il;Park, Soo-Hyun
    • 한국멀티미디어학회논문지
    • /
    • 제18권4호
    • /
    • pp.506-523
    • /
    • 2015
  • The intent is to determine whether or not the custody transfer is helpful for data transmission in challenging underwater communications when running Bundle protocol or underwater protocols. From the point of view defending side, Underwater Acoustic Network (UAN) will be a serious threat for its strong functionality long rang and high precision of surveillance and detection. Therefore, countermeasures must be taken to weaken its effect. Our purpose is analyzed that how to benefit from the UIoT to learn from, exploit and preserve the natural underwater resources. Delay/Disruption Tolerant Network (DTN) is essential part of the network heterogeneity communication network. The vulnerability and potential security factors of UIoT are studied thereafter. Security mechanisms for an underwater environment are difficult to apply owing to the limited bandwidth. Therefore, for underwater security, appropriate security mechanisms and security requirements must be defined simultaneously. The paper consists of mathematical and security model. Most important point of view in the security challenges of effective Buffer and Storage management in DTN.

소닉노즐을 이용한 천연가스 유량측정에서 임계유동인자 계산 및 국제비교 결과 (Evaluation of Critical Flow Factor in Natural Gas Flow Measurement Using Sonic Nozzle and International Comparison Results)

  • 하영철;허재영
    • 대한기계학회논문집B
    • /
    • 제23권7호
    • /
    • pp.911-917
    • /
    • 1999
  • The sonic nozzle is widely used as reference device for calibrating flowmeters In gas flow measurement and its use requires the Critical Flow Factor(CFF) based on the thermodynamic properties of the gas at the nozzle throat. ISO-9300 provides the calculating method of the factor. But since the CFF from this method show an error over ${\pm}0.5%$ In specific conditions and of ${\pm}0.1{\sim}{\pm}0.2%$ in common Natural Gas(NG) custody transfer condition. this method cannot be applied for gas flow measurement with sonic nozzle. Each research bodies or organizations of the world have joined in order to calculate the CFF more accurately. They have performed these works using their own method and compared the results with each other under the management of ISO. KOGAS have joined those works, because the high-pressure natural gas flow calibration facility of KOGAS will be constructed in late 1999, and then had necessities to calculate a CFF accurately. The calculation method of KOGAS was using the equation of state from AGA-8('94), high accuracy model of ideal gas properties and the solutions of thermodynamic equations. The evaluation results have had a very good consistency within ${\pm}0.05%$ in most NO custody transfer conditions compared to the speed of sound for methane and also shown that the CFF was within ${\pm}0.1%$ compared to the results of other works of the world.

Trim & List Sensor의 소개와 설치위치 확정 (The Introduction of the Trim & List Sensor and Confirm of the Sensor Location)

  • 송영승;박경룡;남성일
    • 대한조선학회 특별논문집
    • /
    • 대한조선학회 2008년도 특별논문집
    • /
    • pp.33-37
    • /
    • 2008
  • The evidence of the Cargo tank volume is very important between Buyer and Seller for agreement each other for LNG Ship. CTS(Custody Transfer System) Radar type level gauging sensor to be measured for cargo volume. The data of Trim & List sensor to be compensated for measuring data which is original data of the CTS sensor. The latest days, the Buyer would have posed a problem both the location and the accuracy of trim/list sensor specially neared final stage of the ship's delivery. So, we would like to report the introducing to the trim/list sensor and the confirmation of actual location for the trim/list sensor.

  • PDF

코리올리스 질량유량계의 유량측정에 영향을 미치는 인자에 관한 실험적 연구 (An Experimental Study on the Influential Factors of Flow Measurement with Coriolis Mass Flowmeter)

  • 임기원;이완규
    • 대한기계학회논문집B
    • /
    • 제27권12호
    • /
    • pp.1699-1707
    • /
    • 2003
  • Coriolis mass flowmeter(CMF), which can measure the mass flow directly, is getting rapid attention for the industrial and custody transfer purpose. In order to study the characteristics and the applicability of CMF, it is tested with the national flow standard system. Two types of sensing tube, U-type and straight type, are employed in the test. Water, spindle oil and viscosity Standard Reference Material whose viscosities are 1, 20 and, 67 $\textrm{mm}^2$/s, respectively, are studied. It is shown that the linearity of CMF is getting deteriorated as the fluid viscosity increases, which is due to the zero drift and the relaxation time of the fluid. To test its applicability in the case of high pressured gas, it is calibrated using compressed air, It shows 1∼l.6 % deviations compared to the calibration results using water. It concludes that the fluid velocity in CMF should be lower than the sonic velocity. In addition, the effects of the vibration from the pipeline and pump on CMF as well as the long term stability are studied.

대기압이 가스유량측정에 미치는 영향에 관한 연구 (A Study on the Effect of the Atmospheric Pressure in the Gas Flow Measurement)

  • 정종태;하영철;이철구;허재영
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2002년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.363-369
    • /
    • 2002
  • Orifice meter is the most widely used flowmeter in custody transfer between KOGAS and city gas companies. Absolute pressure value is needed to calculate the gas flow of orifice metering system, but the gauge pressure transmitters are mainly used in the field. In case that the gauge pressure transmitters are used, the fixed value as standard atmospheric pressure(101.325kPa) is applied for the absolute pressure value. The real, local atmospheric pressures of each metering station are different from the standard condition as the altitude and weather conditions. In this study the flow calculation errors were quantitatively analyzed through examining the atmospheric pressures of 50 stations of KOGAS. The data for analysis are such like the time data of supplied gas amount, the altitude of each metering station, the time data of atmospheric pressures and altitudes of each weather observatory. The results showed that the local atmospheric pressures were different from the standard value and the gas flow calculation errors were distributed between $-0.024\%{\~}0.025\%$ based on the supplied gas amount in the year 1999 and 2000.

  • PDF

도시(都市)가스 계량(計量) 편차(偏差) 및 해소방안(解消方案)에 관(關)한 소고(小考) (A Study on the Discrepancies of Gas Measurement and the Solution Measures between Suppliers and Consumers in South Korea)

  • 박상철;방선혁
    • 한국가스학회지
    • /
    • 제14권3호
    • /
    • pp.26-34
    • /
    • 2010
  • 한국가스공사는 1983년 가스의 안정적인 공급을 위해 특별법에 의거 설립되었으며 30개 지역의 가스소매를 담당하는 도시가스회사에 천연가스 도매공급을 전담하고 있다. 가스공사가 수입하는 가스의 측정방식은 LNG 하역 전후의 수송선 액위를 측정함으로써 계량한다. 이때 가스성분분석은 수입가스의 가격이 열량에 의해 산정되기 때문에 필수적이다. 또한 터빈미터는 도시가스사로 공급하는 가스의 계량에 널리 쓰이고 있다. 그러나 발전용으로 공급되는 가스의 계량설비와는 달리 도시가스사로 공급되는 가스를 계량하는 설비에는 가스요금이 열량에 의해서가 아니라 부피에 의해서 부과되기 때문에 가스성분을 측정하는 분석기가 없다. 따라서 도시가스사가 가스공사로부터 구입하는 가스양과 소비자에게 판매하는 가스양이 일치하지 않는 문제점이 발생한다. 그 이유는 소매용 가스미터에 내재하는 오차와 운용상의 문제로 인해 도매용 계량설비와 소매용 가스미터의 수치에는 차이가 있기 때문이다. 본 논문에서는 도시가스사와 일반 소비자 간의 실제 가스양에 대한 논쟁에 관해 조사하였으며 가스 계량오차에 관한 문제점을 해소하기 위한 바람직한 기술적, 경제적 정책방향을 제안하는데 중점을 두었다.