• Title/Summary/Keyword: Curve type

Search Result 1,561, Processing Time 0.029 seconds

Weekly irinotecan and carboplatin for patients with small cell lung cancer (소세포 폐암 환자에서 이리노테칸, 카보플라틴 주별 분할 항암요법의 효과)

  • Lee, Hye-Won;Jeong, Eu Gene;Kim, Dong Hyun;Lee, Hyuk;Kang, Bo Hyoung;Um, Soo-Jung;Roh, Meesook;Son, Choonhee
    • Journal of Yeungnam Medical Science
    • /
    • v.31 no.2
    • /
    • pp.82-88
    • /
    • 2014
  • Background: Lung cancer is the most common cause of cancer-related death worldwide and in Korea, and small cell lung cancer (SCLC) is the most deadly tumor type in the different lung cancer histology. Chemotherapy is the main strategy of the treatment for SCLC, and etoposide and platinum regimen has been the only standard chemotherapy for about 30 years. To test feasibility of weekly divided dose irinotecan and carboplatin for Korean patients is the aim of this study. Methods: Patients with histologically or cytologically confirmed extensive stage SCLC were included. Patients with limited stage (LD), who could not tolerate concurrent chemoradiotherapy were also included. All the patients received irinotecan $60mg/m^2$, carboplatin 2 area under the curve at day 1, 8, and 15 every 4 weeks. Study regimen was discontinued when the disease progressed or intolerable side effects occurred. No more than 6 cycles of chemotherapy were given. Results: Total 47 patients were enrolled, among them 9 patients were LD. Overall response rate was 74.5% (complete response, 14.9%; partial response, 59.6%). Side effects greater than grade 3 were neutropenia (25.5%), fatigue (12.8%), thrombocytopenia (8.5%), sepsis (4.3%), and pancytopenia (2.1%). There was no treatment related death. Conclusion: Weekly divided irinotecan and carboplatin regimen is effective, and safe as a first line therapy for both stage of SCLC. Large scaled, controlled study is feasible.

A Study on the Development of Soil-based PTMs for Analysis of Benzo[a]pyrene - Focusing on the Evaluation of Homogeneity and Stability for the Certification of Benzo[a]pyrenecandidate Reference Materials - (Benzo[a]pyrene 분석용 토양 숙련도 표준시료 개발에 관한 연구 - 후보 표준물질의 인증을 위한 균질성, 안정성 평가를 중심으로 -)

  • Lee, Minhyo;Lee, Guntaek;Joo, Changkyu;Kim, Yonghun;Lee, Bupyoel;Choe, Sunghun;Kim, Myeongock;Hong, Sukyoung;Kim, Gumhee;Lee, Wonseok
    • Journal of Soil and Groundwater Environment
    • /
    • v.19 no.6
    • /
    • pp.49-58
    • /
    • 2014
  • This study was implemented as a part of the experiment to develop two kinds of soil-based Benzo[a]pyrene (BaP) proficiency testing materials (PTMs) for soil analysis. A test was carried out for the check of solubility of the reference material (high purity reagent) using several solvents. Another test was also conducted for the evaluation of homogeneity and stability of two kinds of candidate soil reference materials. The test analysis of BaP in terms of the candidate materials was conducted according to the Standard Soil Analytical Methods by Ministry of Environment. Dissolution of the reference material was shown to vary depending on solvent type and was higher in the order of Dichloromethane > Acetone > Acetone/MeOH (9 : 1) > N-hexane. In addition, the slope on calibration curve for BaP standard solutions was largest on BaP standard solutions prepared with dichloromethane of the tested solvents. Such tendency appeared egually in the commercial BaP standard solution. Therefore, it is thought to be reasonable to use dichloromethane as the solvent in case of the standard stock solution that is used for the measurement of BaP concentration in soil. ISO 13528 and IUPAC protocol were used for verification of homogeneity on the two kinds of soil candidate materials, Both candidate materials were sufficiently homogeneous. Stability assessment of the two candidate materials was made according to ISO Guide 35 and the result showed that both batches did not have any long-term and short term stability issues that might occur during shipping. However, monitoring results of BaP concentration in soil showed that BaP concentration of the two batches measured at 15 days after the sample preparation was reduced by about 24~37% compared with that of the samples measured on 0 day of the sample preparation. Identification was done with several treatments such as irradiation and sterilization etc. The major cause was shown to be irradiation to the samples.

High temperature electrical properties of Sr-and Mg-Doped LaAlO3 (억셉터(Sr, Mg)가 첨가된 LaAlO3의 고온 전도 특성)

  • Park, Ji Young;Park, Hee Jung
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.29 no.5
    • /
    • pp.187-191
    • /
    • 2019
  • Perovskite-type oxides have consistently attracted considerable attention for their applications in high-temperature electrochemical devices, such as electrolytes and electrodes of solid oxide fuel cells, oxygen permeating membranes and sensors etc. Among them, the electrical conductivity of 10 % Sr and 10 % Mg doped $LaAlO_3$ (LSAM9191) was measured using impedance spectroscopy and 4-probe d.c. method. Below $550^{\circ}C$, the grain boundary resistance mostly determined the overall conductivity; however, it nearly disappeared above $800^{\circ}C$. Using the defect model and curve fitting, the ionic and electronic conductivity contributions were also separated. In the temperature region where the sample resistance is mostly determined by the grain volume property, LSAM9191 was an oxygen ion conductor at low $Po_2$ and a mixed conductor at high $Po_2$. With increasing temperature, the ionic conduction region only slightly increased. Thus, LSAM9191 is a promising material as an oxygen ion conductor at high temperature and in low $Po_2$.

Usefulness of the SAFARI score for predicting convulsive seizure in patients with aneurysmal subarachnoid hemorrhage (비외상성 동맥류성지주막하출혈 환자에서 SAFARI 점수를 이용한 경련 발생 예측의 유용성)

  • Baik, Seung Jun;Hong, Dae Young;Kim, Sin Young;Kim, Jong Won;Park, Sang O;Lee, Kyeong Ryong;Baek, Kwang Je
    • Journal of The Korean Society of Emergency Medicine
    • /
    • v.29 no.5
    • /
    • pp.449-454
    • /
    • 2018
  • Objective: The SAFARI score was introduced to assess the risk of convulsive seizure during admission for aneurysmal subarachnoid hemorrhage in 2017. This study was conducted to determine whether the SAFARI score derived from the afore-mentioned study could be applied to patients with aneurysmal subarachnoid hemorrhage in Korea. Methods: We conducted a retrospective study of patients who were diagnosed with aneurysmal subarachnoid hemorrhage from March 2013 to October 2017. Patients' age, sex, blood pressure, pulse rate, body temperature, Glasgow-Coma Scale, Hunt-Hess scale, modified Fisher grade, size of ruptured aneurysm, surgery type, transfusion, and SAFARI score were compared between the seizure and non-seizure groups. The area under the receiver operator characteristic curves was calculated to evaluate the predictive ability for seizure during admission. Logistic regression analysis was used to analyze predictive factors for seizure during admission. Results: A total of 220 patients were included. Ninety-seven (44.1%) were male and 123 (55.9%) were female. The mean age of the patients was 65.8 years old (range, 56-75). The area under the curve of the SAFARI score for predicting seizure was 0.813. The SAFARI score was the only significant predictor of seizure during admission, while other factors were not statistically significant upon logistic regression analysis. Conclusion: The SAFARI score could be used for predicting seizure during admission in patients with aneurysmal subarachnoid hemorrhage.

Oral Bioavailability for Sub-micron Particle Curcumin (TheracurminCR-033P) and Absorption Rate by Product Composition in Healthy Human Volunteers (서브마이크론 입자 형태 커큐민의 생체 흡수율 및 제품 조성에 따른 흡수율 동등성 연구)

  • Park, Hee Jung;Takahashi, Tsukasa;Ozawa, Hitomi
    • Food Engineering Progress
    • /
    • v.21 no.3
    • /
    • pp.273-279
    • /
    • 2017
  • Curcumin have various health-beneficial properties in numerous studies. However, its bioavailability is low due to its limited intestinal uptake and rapid metabolism. This study aimed to evaluate the pharmacokinetics of newly developed sub-micron particle curcumin with increased water dispersibility (Theracurmin(R) CR-033P). Plasma curcumin levels were measured at 0, 1, 2, 4, 8 h after Theracurmin(R) CR-033P intake using high-performance liquid chromatography. For analyzing pharmacokinetics of Theracurmin(R) CR-033P, eighteen healthy subjects were recruited and received Theracurmin(R) CR-033P at a single oral dose containing curcumin 30 mg. $C_{max}$ was 28.14 ng/ml, and the area under the curve for 8 h was estimated to be 104.36 ng/ml. Based on the area under the plasma concentration (AUC), the bioavailability of sub-micron particle curcumin was higher 22-, 35-, 28-fold than native curcumin in men, women, and all subjects, respectively. For comparing by formulation, seven healthy subjects were recruited and received two type of treatment: (1) existing dosage form 300 mg (contained curcumin 30 mg) ${\times}$ 3 capsule, (2) high dosage form 300 mg (contained curcumin 90 mg) ${\times}$ 1 capsule + placebo 300 mg ${\times}$ 2 capsule. In the cross-over study, there was no significant differences in $C_{max}$ and AUC of plasma curcumin. In conclusion, submicron particle curcumin with increased water dispersibility significantly improved its oral bioavailability and women absorbed curcumin more effectively than men. Different formulation of Theracurmin(R) CR-033P has shown equivalent to the reference in terms of pharmacokinetics.

Risk-Scoring System for Prediction of Non-Curative Endoscopic Submucosal Dissection Requiring Additional Gastrectomy in Patients with Early Gastric Cancer

  • Kim, Tae-Se;Min, Byung-Hoon;Kim, Kyoung-Mee;Yoo, Heejin;Kim, Kyunga;Min, Yang Won;Lee, Hyuk;Rhee, Poong-Lyul;Kim, Jae J.;Lee, Jun Haeng
    • Journal of Gastric Cancer
    • /
    • v.21 no.4
    • /
    • pp.368-378
    • /
    • 2021
  • Purpose: When patients with early gastric cancer (EGC) undergo non-curative endoscopic submucosal dissection requiring gastrectomy (NC-ESD-RG), additional medical resources and expenses are required for surgery. To reduce this burden, predictive model for NC-ESD-RG is required. Materials and Methods: Data from 2,997 patients undergoing ESD for 3,127 forceps biopsy-proven differentiated-type EGCs (2,345 and 782 in training and validation sets, respectively) were reviewed. Using the training set, the logistic stepwise regression analysis determined the independent predictors of NC-ESD-RG (NC-ESD other than cases with lateral resection margin involvement or piecemeal resection as the only non-curative factor). Using these predictors, a risk-scoring system for predicting NC-ESD-RG was developed. Performance of the predictive model was examined internally with the validation set. Results: Rate of NC-ESD-RG was 17.3%. Independent pre-ESD predictors for NC-ESD-RG included moderately differentiated or papillary EGC, large tumor size, proximal tumor location, lesion at greater curvature, elevated or depressed morphology, and presence of ulcers. A risk-score was assigned to each predictor of NC-ESD-RG. The area under the receiver operating characteristic curve for predicting NC-ESD-RG was 0.672 in both training and validation sets. A risk-score of 5 points was the optimal cut-off value for predicting NC-ESD-RG, and the overall accuracy was 72.7%. As the total risk score increased, the predicted risk for NC-ESD-RG increased from 3.8% to 72.6%. Conclusions: We developed and validated a risk-scoring system for predicting NC-ESD-RG based on pre-ESD variables. Our risk-scoring system can facilitate informed consent and decision-making for preoperative treatment selection between ESD and surgery in patients with EGC.

An Experimental Study on the Development and Possible Solution of Thermal Runaway Model of Electronic Moxibustion with System Error (전자뜸의 시스템 오류에 의한 열폭주 모델 구현 및 해결 방법에 관한 실험적 연구)

  • Lee, Byung Wook;Oh, Yong Taek;Jang, Hansol;Choi, Seong-Kyeong;Jo, Hyo Rim;Sung, Won-Suk;Kim, Eun-Jung
    • Korean Journal of Acupuncture
    • /
    • v.38 no.4
    • /
    • pp.282-289
    • /
    • 2021
  • Objectives : The purpose of this study is to construct a model of the possible thermal runaway of electronic moxibustion and to implement an appropriate risk management method. Methods : To reproduce the system error situation of the electronic moxibustion circuit equipped with microcontroller unit, temperature sensor and heater, a code was set to disable the signal input to temperature sensor and maintain "high" heating signal to heater. The temperature change of electronic moxibustion was compared between 3 types of heater module; module 1 consisting of a combination of heater+0 ohm+0 ohm resistance, module 2 consisting of a combination of heater+Polymeric Positive Temperature Coefficient (PPTC)+0 ohm resistance, and module 3 consisting of a combination of heater+PPTC+10 ohm resistance. The temperature change was measured using a polydimethylsiloxane (PDMS) silicone phantom. After maintaining surface temperature of the phantom at 31~32℃ for 20 seconds, electronic moxibustion was applied. After operating electronic moxibustion, the temperature change was measured for 660 seconds on the surface and 900 seconds at 2 mm depth. Results : Regardless of the module type, the time-dependent change in temperature showed a rapid rise followed by a gentle curve, and a sharp drop in temperature after reaching the maximum temperature about 10 minutes after the switching the moxibustion on. Temperature measured at the depth of 2 mm below the surface increased slower and to a lesser extent. Module 1 reached highest peak temperature with largest change of temperature at both depths followed by module 2, and 3. Conclusions : Through the combination of PPTC+resistance with the heater of electronic moxibustion, it is possible to limit the rise in temperature even with the software error. Thus, this setting can be used as an independent safety measure for the electronic moxibustion control unit.

Measurement uncertainty analysis of radiophotoluminescent glass dosimeter reader system based on GD-352M for estimation of protection quantity

  • Kim, Jae Seok;Park, Byeong Ryong;Yoo, Jaeryong;Ha, Wi-Ho;Jang, Seongjae;Jang, Won Il;Cho, Gyu Seok;Kim, Hyun;Chang, Insu;Kim, Yong Kyun
    • Nuclear Engineering and Technology
    • /
    • v.54 no.2
    • /
    • pp.479-485
    • /
    • 2022
  • At the Korea Institute of Radiological and Medical Sciences, physical human phantoms were developed to evaluate various radiation protection quantities, based on the mesh-type reference computational phantoms of the International Commission on Radiological Protection. The physical human phantoms were fabricated such that a radiophotoluminescent glass dosimeter (RPLGD) with a Tin filter, namely GD-352M, could be inserted into them. A Tin filter is used to eliminate the overestimated signals in low-energy photons below 100 keV. The measurement uncertainty of the RPLGD reader system based on GD-352M should be analyzed for obtaining reliable protection quantities before using it for practical applications. Generally, the measurement uncertainty of RPLGD systems without Tin filters is analyzed for quality assurance of radiotherapy units using a high-energy photon beam. However, in this study, the measurement uncertainty of GD-352M was analyzed for evaluating the protection quantities. The measurement uncertainty factors in the RPLGD include the reference irradiation, regression curve, reproducibility, uniformity, energy dependence, and angular dependence, as described by the International Organization for Standardization (ISO). These factors were calculated using the Guide to the Expression of Uncertainty in Measurement method, applying ISO/ASTM standards 51261(2013), 51707(2015), and SS-ISO 22127(2019). The measurement uncertainties of the RPLGD reader system with a coverage factor of k = 2 were calculated to be 9.26% from 0.005 to 1 Gy and 8.16% from 1 to 10 Gy. A blind test was conducted to validate the RPLGD reader system, which demonstrated that the readout doses included blind doses of 0.1, 1, 2, and 5 Gy. Overall, the En values were considered satisfactory.

Prediction of Potential Habitat and Damage Amount of Rare·Endemic Plants (Sophora Koreensis Nakai) Using NBR and MaxEnt Model Analysis - For the Forest Fire Area of Bibongsan (Mt.) in Yanggu - (NBR과 MaxEnt 모델 분석을 활용한 희귀특산식물(개느삼) 분포 및 피해량 예측 - 양구 비봉산 산불피해지를 대상으로-)

  • Yun, Ho-Geun;Lee, Jong-Won;An, Jong-Bin;Yu, Seung-Bong;Bak, Gi-Ppeum;Shin, Hyun-Tak;Park, Wan-Geun;Kim, Sang-Jun
    • Korean Journal of Plant Resources
    • /
    • v.35 no.2
    • /
    • pp.169-182
    • /
    • 2022
  • This study was conducted to predict the distribution of rare·endemic plants (Sophora koreensis Nakai) in the border forests where wildfire damage occurred and to quantify the damage. For this purpose, we tried to derive more accurate results through forest area damage (NBR) according to the Burn severity of wildfires, damage by tree species type (Vegetation map), and MaxEnt model. For Burn severity analysis, satellite imagery (Landsat-8) was used to analyze Burn severity (ΔNBR2016-2015) and to derive the extent of damage. To prepare the Vegetation map, the land cover map prepared by the Ministry of Environment, the Vegetation map prepared by the Korea Forest Service, and the vegetation survey conducted by itself were conducted to prepare the clinical map before and after the forest fire. Lastly, for MaxEnt model analysis, the AUC value was derived by using the habitat coordinates of Sophora koreensis Nakai based on the related literature and self-report data. As a result of combining the Maxent model analysis data with the Burn severity data, it was confirmed that 45.9% of the 44,760 m2 of habitat (predicted) area of Sophora koreensis Nakai in the wildfire damaged area or 20,552 m2, was damaged.

Evaluation of Deformation Capacity of Various Steel Springs Subjected to Tensile Loading or Uniaxial Cyclic Loading (인장하중 및 반복하중을 받는 강재 스프링의 변형 성능 평가)

  • Kwon, Hee-Yong;Hwang, Seung-Hyeon;Yang, Keun-Hyeok;Kim, Sanghee;Choi, Yong-Soo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.26 no.4
    • /
    • pp.1-10
    • /
    • 2022
  • In this study, to evaluate the possibility of using a steel spring as a displacement-dependent damping device, tensile loading and cyclic loading tests were performed. The main experimental variables were the type of steel (SAE9254 and SS275), the spring constant (700 N/mm, 1,000 N/mm, and 1,400 N/mm), and the presence or absence of heat treatment for SAE9254. As a result of the tensile test, the ratios of the measured spring constant to the design spring constant of the steel springs made with SAE9254 ranged from 1.08 to 1.13, while the ratios of the design spring constant and the measured spring constant of the steel springs made with SS275 ranged from 0.86 to 0.97. After yielding, the slope values of the load-displacement curve of the SAE9254 with/without heat treatment were about 240~251 N/mm and 92 N/mm, respectively, but the slope values of the load-displacement response of SS275 were almost zero. According to the uniaxial cyclic loading test results, all specimens were satisfied with three conditions for a displacement-dependent damping device in KDS 41 17 00 (2019): the maximum force and minimum force at zero displacement, the maximum force and minimum force at the maximum displacement, and the energy dissipation capacity. In addition, the equivalent damping ratios of steel springs made with SAE9254(non-heat treatment) and SS275 were approximately 2.8 times and 1.9 times greater, respectively, than that of steel springs made with SAE9254.