• Title/Summary/Keyword: Curve measurement

Search Result 987, Processing Time 0.023 seconds

Quantitative analysis method for zingiber officinale water extract using high-performance liquid chromatography

  • Mohd S. Md Sarip;Nik M.A. Nik Daud;Mohd A. Mohd Zainudin;Lokman H. Ibrahim;Syahrul A. Saidi;Zuhaili Idham;Adilah Anuar
    • Advances in materials Research
    • /
    • v.13 no.3
    • /
    • pp.233-241
    • /
    • 2024
  • Quantitative analysis of the Zingiber Officinale sample using subcritical water extraction (SWE) was developed employing High-Performance Liquid Chromatography (HPLC) to bolster the advancement of this innovative green extraction process. This research focuses on three principal ginger bioactive compounds: 6-gingerol, 6-shagoal, and 10-gingerol. Various stages were undertaken to establish the quantitative analysis method, encompassing the optimisation of HPLC operating conditions and the formulation of standard calibration curves, yielding individual compound equations. A robust correlation within the calibration curve was achieved, exhibiting an r2 value of 0.9814 and an RSD of 5.00%. A simultaneous, swift, and dependable method was established with an injection time of 20 minutes and an 8-minute delay between injections, in contrast to the previous HPLC analysis requiring a 45-minute injection time for detecting and quantifying all components. Notably, no post-treatment was applied after the SWE process. This advancement allows for potential future online measurement of Zingiber Officinale bioactive compounds extracted using subcritical water extraction through this technology.

Electrical Remodeling of Left Atrium Is a Better Predictor for Recurrence Than Structural Remodeling in Atrial Fibrillation Patients Undergoing Radiofrequency Catheter Ablation

  • Yun Gi Kim;Ha Young Choi;Jaemin Shim;Kyongjin Min;Yun Young Choi;Jong-Il Choi;Young-Hoon Kim
    • Korean Circulation Journal
    • /
    • v.52 no.5
    • /
    • pp.368-378
    • /
    • 2022
  • Background and Objectives: Recurrence rates after radiofrequency catheter ablation (RFCA) in atrial fibrillation (AF) patients are not low especially in non-paroxysmal AF. The diameter of left atrium (LA) has been widely used to predict the recurrence after RFCA for decades. However, LA diameter represents structural remodeling of LA and does not reflect electrical remodeling. We aimed to determine the predictive value of electrical remodeling of LA which is represented by the amount of low voltage zone (LVZ). Methods: We performed a retrospective cohort analysis of AF patients who underwent de novo RFCA in a single-center. Results: A total of 3,120 AF patients with de novo RFCA were analyzed. Among these patients, 537 patients underwent an electroanatomic mapping with bipolar voltage measurement of LA. The diameter of LA and flow velocity of LA appendage (LAA) differed significantly according to quartile group of LVZ area and percentage: patients with high LVZ had large LA diameter and low LAA flow velocity (p<0.001). Freedom from late recurrence (LR) was significantly lower in patients with high LVZ area and percentage (p<0.001). The diameter and surface area of LA had area under curve (AUC) of 0.592 and 0.593, respectively (p=0.002 for both). The predictive value of LVZ area (AUC, 0.676) and percentage (AUC, 0.671) were both superior compared with LA diameter (p=0.011 and 0.027 for each comparison). Conclusions: In conclusion, LVZ can predict freedom from LR after RFCA in AF patients. Predictive value was higher in parameters reflecting electrical rather than structural remodeling of LA.

The Comparison of Basic Science Research Capacity of OECD Countries

  • Lim, Yang-Taek;Song, Choong-Han
    • Journal of Technology Innovation
    • /
    • v.11 no.1
    • /
    • pp.147-176
    • /
    • 2003
  • This Paper Presents a new measurement technique to derive the level of BSRC (Basic Science and Research Capacity) index by use of the factor analysis which is extended with the assumption of the standard normal probability distribution of the selected explanatory variables. The new measurement method is used to forecast the gap of Korea's BSRC level compared with those of major OECD countries in terms of time lag and to make their international comparison during the time period of 1981∼1999, based on the assumption that the BSRC progress function of each country takes the form of the logistic curve. The US BSRC index is estimated to be 0.9878 in 1981, 0.9996 in 1990 and 0.99991 in 1999, taking the 1st place. The US BSRC level has been consistently the top among the 16 selected variables, followed by Japan, Germany, France and the United Kingdom, in order. Korea's BSRC is estimated to be 0.2293 in 1981, taking the lowest place among the 16 OECD countries. However, Korea's BSRC indices are estimated to have been increased to 0.3216 (in 1990) and 0.44652 (in 1999) respectively, taking 10th place. Meanwhile, Korea's BSRC level in 1999 (0.44652) is estimated to reach those of the US and Japan in 2233 and 2101, respectively. This means that Korea falls 234 years behind USA and 102 years behind Japan, respectively. Korea is also estimated to lag 34 years behind Germany, 16 years behind France and the UK, 15 years behind Sweden, 11 years behind Canada, 7 years behind Finland, and 5 years behind the Netherlands. For the period of 1981∼1999, the BSRC development speed of the US is estimated to be 0.29700. Its rank is the top among the selected OECD countries, followed by Japan (0.12800), Korea (0.04443), and Germany (0.04029). the US BSRC development speed (0.2970) is estimated to be 2.3 times higher than that of Japan (0.1280), and 6.7 times higher than that of Korea. German BSRC development speed (0.04029) is estimated to be fastest in Europe, but it is 7.4 times slower than that of the US. The estimated BSRC development speeds of Belgium, Finland, Italy, Denmark and the UK stand between 0.01 and 0.02, which are very slow. Particularly, the BSRC development speed of Spain is estimated to be minus 0.0065, staying at the almost same level of BSRC over time (1981 ∼ 1999). Since Korea shows BSRC development speed much slower than those of the US and Japan but relative]y faster than those of other countries, the gaps in BSRC level between Korea and the other countries may get considerably narrower or even Korea will surpass possibly several countries in BSRC level, as time goes by. Korea's BSRC level had taken 10th place till 1993. However, it is estimated to be 6th place in 2010 by catching up the UK, Sweden, Finland and Holland, and 4th place in 2020 by catching up France and Canada. The empirical results are consistent with OECD (2001a)'s computation that Korea had the highest R&D expenditures growth during 1991∼1999 among all OECD countries ; and the value-added of ICT industries in total business sectors value added is 12% in Korea, but only 8% in Japan. And OECD (2001b) observed that Korea, together with the US, Sweden, and Finland, are already the four most knowledge-based countries. Hence, the rank of the knowledge-based country was measured by investment in knowledge which is defined as public and private spending on higher education, expenditures on R&D and investment in software.

  • PDF

Comparison of the measurement methods of soil water content by error analysis (토양수분(土壤水分) 함량(含量) 측정방법별(測定方法別) 오차분석(誤差分析)에 의(依)한 비교(比較))

  • Eom, K.C.;Ryu, K.S.;Um, K.T.
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.21 no.4
    • /
    • pp.367-372
    • /
    • 1988
  • A series of field experiment was conducted to find out error range and to compare precision based on error analysis of soil water content measured with gravimetric, surface & depth neutron and gypsum block methods in a sandy loam soil. The error of soil water content measured with gravimetric (core-sampling), surface and depth neutron method showed quardratic curve, whereas that with gypsum block was exponential curve in relation to soil water content. Within the range of volumetric soil water content from 11 to 33%, the error of soil water content measured with gravimetric, surface neutron, depth neutron and gypsum block method was ranged from 0.28 to 3.49%, 0.71 to 2.63%, 0.52% to 1.01% and 0.05 to 21.89%, respectively. The error of soil water content measured with depth neutron method was lower than those of other methods, when the soil water content was more than 14% in sandy loam soil. The relative number of replicates of soil water measurement for surface neutron, depth neutron and gypsum block method to attain same precision for gravimetric method was 0.6-1.7, 0.07-0.8 and 0.1-125, respectively.

  • PDF

Measurement of Regional Cerebral Blood Volume in Normal Rabbits on Perfusion-weighted MR Image (MR 관류강조영상에서 정상 가토의 국소 뇌혈류량 측정)

  • 박병래;예수영;나상옥;김학진;이석홍;전계록
    • Investigative Magnetic Resonance Imaging
    • /
    • v.4 no.2
    • /
    • pp.100-106
    • /
    • 2000
  • Purpose : To evaluate the usefulness of cerebral blood flow measurement applied to perfusion weighted image with short-scan time single shot gradient echo-planar technique in measuring cerebral blood volume(rCBV) of normal rabbits. Materials and methods : With 2.1-3.6 kg weighted rabbits, image is acquired when they are in supine position in children positioner. Perfusion weighted image is acquired to 44 seconds per 1 second successively. After 4 seconds later, Gd-DTPA 2ml are injected into int. jugular vein with 2 ml per second and normal saline is also injected after that. Same technique is applied 2 times per 30 minites in same rabbit. After Image is obtained in two part of cerebral cortex at vertex, convexity, in one of basal ganglia with choosing about $3-5{\textrm{mm}^2}$ areas. Curve of signal intensity changes in time sequence is drawn. After this images are transmitted by PC and software IDL, regional cerebral blood volume is measured with imaging processing program made by us. Results : With 22 of 24 rabbits, satisfactory 1-2 signal intensity versus time curve is made. Cerebral blood capacity and contrast media stay time (ST) is measured in two cerebral cortex and basal ganglia refering in parietal cerebral cortex. Mean focal cerebral blood flow capacity ratio in cortex was $0.97{\pm}0.35$ and in basal ganglia, $0.99{\pm}0.37$, mean contrast media stay time in cortex was $9.83{\pm}1.63$ sec and in basal gaiglia, $9.42{\pm}1.14$ sec, but there was no statistically significant difference between two areas ($\rho$=0.05). Conclusion : In cerebral cortex and basal ganglia, there is no difference in mean focal blood volume and mean contrast stay time. Therefore, PWI is useful in cerebral blood flow and early diagnosis, prognosis of cerebral ischemic disease. Hereafter, it is helpful in analysing cerebral blood flow changes with comparison difference in rCBV between normal tissue and ischemic tissue, and that with DWI finding in infarcted patient.

  • PDF

Evaluation of microplastic in the inflow of municipal wastewater treatment plant according to pretreatment methods (전처리 방법에 따른 하수처리장 유입수에서의 미세플라스틱 성상분석 평가)

  • Kim, Sungryul;Gil, Kyungik
    • Journal of Wetlands Research
    • /
    • v.24 no.2
    • /
    • pp.83-92
    • /
    • 2022
  • The amount of the plastic waste has been increasing according to global demand for plastic. Microplastics are the most hazardous among all plastic pollutants due to their toxicity and unknown physicochemical properties. This study investigates the optimal methodology that can be applied to sewage samples for detecting microplastics before discussing reducing microplastics in MWTPs. In this study, the effect of different pretreatment methods while detecting microplastic analysis of MWTP influent samples was investigated; the samples were collected from the J sewage treatment plant. There are many pretreatment methods but two of them are widely used: Fenton digestion and hydrogen peroxide oxidation. Although there are many pretreatment methods that can be applied to investigate microplastics, the most widely used methods for sewage treatment plant samples are Fenton digestion and H2O2 oxidation. For each pretreatment method, there were factors that could cause an error in the measurement. To overcome this, in the case of the Fenton digestion pretreatment, it is recommended to proceed with the analysis by filtration instead of the density separation method. In the case of the H2O2 oxidation method, the process of washing with distilled water after the reaction is recommended. As a result of the analysis, the concentration of microplastics was measured to be 2.75ea/L for the sample using the H2O2 oxidation method and 3.2ea/L for the sample using the Fenton oxidation method, and most of them were present in the form of fibers. In addition, it is difficult to guarantee the reliability of measurement results from quantitative analysis performed via microscope with eyes. A calibration curve was created for prove the reliability. A total of three calibration curves were drawn, and as a result of analysis of the calibration curves, all R2 values were more than 0.9. This ensures high reliability for quantitative analysis. The qualitative analysis could determine the series of microplastics flowing into the MWTP, but could not confirm the chemical composition of each microplastic. This study can be used to confirm the chemical composition of microplastics introduced into MWTP in the future research.

Application and Comparative Analysis of River Discharge Estimation Methods Using Surface Velocity (표면유속을 이용한 하천 유량산정방법의 적용 및 비교 분석)

  • Jae Hyun, Song;Seok Geun Park;Chi Young Kim;Hung Soo Kim
    • Journal of Korean Society of Disaster and Security
    • /
    • v.16 no.2
    • /
    • pp.15-32
    • /
    • 2023
  • There are some difficulties such as safety problem and need of manpower in measuring discharge by submerging the instruments because of many floating debris and very fast flow in the river during the flood season. As an alternative, microwave water surface current meters have been increasingly used these days, which are easy to measure the discharge in the field without contacting the water surface directly. But it is also hard to apply the method in the sudden and rapidly changing field conditions. Therefore, the estimation of the discharge using the surface velocity in flood conditions requires a theoretical and economical approach. In this study, the measurements from microwave water surface current meter and rating curve were collected and then analyzed by the discharge estimation method using the surface velocity. Generally, the measured and converted discharge are analyzed to be similar in all methods at a hydraulic radius of 3 m or over or a mean velocity of 2 ㎧ or more. Besides, the study computed the discharge by the index velocity method and the velocity profile method with the maximum surface velocity in the section where the maximum velocity occurs at the high water level range of the rating curve among the target locations. As a result, the mean relative error with the converted discharge was within 10%. That is, in flood season, the discharge estimation method using one maximum surface velocity measurement, index velocity method, and velocity profile method can be applied to develop high-level extrapolation, therefore, it is judged that the reliability for the range of extrapolation estimation could be improved. Therefore, the discharge estimation method using the surface velocity is expected to become a fast and efficient discharge measurement method during the flood season.

Development and assessment of pre-release discharge technology for response to flood on deteriorated reservoirs dealing with abnormal weather events (이상기후대비 노후저수지 홍수 대응을 위한 사전방류 기술개발 및 평가)

  • Moon, Soojin;Jeong, Changsam;Choi, Byounghan;Kim, Seungwook;Jang, Daewon
    • Journal of Korea Water Resources Association
    • /
    • v.56 no.11
    • /
    • pp.775-784
    • /
    • 2023
  • With the increasing trend of extreme rainfall that exceeds the design frequency of man-made structures due to extreme weather, it is necessary to review the safety of agricultural reservoirs designed in the past. However, there are no local government-managed reservoirs (13,685) that can be discharged in an emergency, except for reservoirs over a certain size under the jurisdiction of the Korea Rural Affairs Corporation. In this case, it is important to quickly deploy a mobile siphon to the site for preliminary discharge, and this study evaluated the applicability of a mobile siphon with a diameter of 200 mm, a minimum water level difference of 6 m, 420 (m2/h), and 10,000 (m2/day), which can perform both preliminary and emergency discharge functions, to the Yugum Reservoir in Gyeongju City. The test bed, Yugum Reservoir, is a facility that was completed in 1945 and has been in use for about 78 years. According to the hydrological stability analysis, the lowest height of the current dam crest section is 27.15 (EL.m), which is 0.29m lower than the reviewed flood level of 27.44 (EL.m), indicating that there is a possibility of lunar flow through the embankment, and the headroom is insufficient by 1.72 m, so it was reviewed as not securing hydrological safety. The water level-volume curve was arbitrarily derived because it was difficult to clearly establish the water level-flow relationship curve of the reservoir since the water level-flow measurement was not carried out regularly, and based on the derived curve, the algorithm for operating small and medium-sized old reservoirs was developed to consider the pre-discharge time, the amount of spillway discharge, and to predict the reservoir lunar flow time according to the flood volume by frequency, thereby securing evacuation time in advance and reducing the risk of collapse. Based on one row of 200 mm diameter mobile siphons, the optimal pre-discharge time to secure evacuation time (about 1 hour) while maintaining 80% of the upper limit water level (about 30,000 m2) during a 30-year flood was analyzed to be 12 hours earlier. If the pre-discharge technology utilizing siphons for small and medium-sized old reservoirs and the algorithm for reservoir operation are implemented in advance in case of abnormal weather and the decision-making of managers is supported, it is possible to secure the safety of residents in the risk area of reservoir collapse, resolve the anxiety of residents through the establishment of a support system for evacuating residents, and reduce risk factors by providing risk avoidance measures in the event of a reservoir risk situation.

Characteristics of the Maximum Glow Intensity According to the Thermoluminescent Phosphors used in the Absorbed Dose Measurement of the Radiation Therapy (방사선치료 선량 측정에 사용되는 열형광체에 따른 최대 형광 강도 특성)

  • Kang, Suman;Im, Inchul;Park, Cheolwoo;Lee, Mihyeon;Lee, Jaeseung
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.4
    • /
    • pp.181-187
    • /
    • 2014
  • The purpose of this study were to analyze the characteristic of the glow curves in order to the glow temperature of the thermoluminescent dosimeters (TLDs) for the absorbed dose measurement of the radiation therapy. In this study, we was used the TLDs of the LiF:Mg${\cdot}$Ti, LiF:Mg${\cdot}$Cu${\cdot}$P, $CaF_2$:Dy, $CaF_2$:Mn (Thermo Fisher Scientific Inc., USA). The source-to-solid dry phantom (RW3 slab, IBA Dosmetry, Germany) surface distance was set at 100 cm, and the exposure dose of 100 MU (monitor unit) was used 6- and 15-MV X-rays, and 6- and 12-MeV electron beams in the reference depth, respectively. After the radiations exposure, we were to analyze the glow curves by using the TL reader (Hashaw 3500, Thermo Fisher Scientific Inc., USA) at the fixed heating rate of $15^{\circ}C/sec$ from $50^{\circ}C$ to $260^{\circ}C$. The glow peaks, the trapping level in the captured electrons and holes combined with the emitted light, were discovered the two or three peak. When the definite increasing the temperature of the TLDs, the maximum glow peak representing the glow temperature was follow as; $LiF:Mg{\cdot}Ti$: $185.5{\pm}1.3^{\circ}C$, $LiF:Mg{\cdot}Ti$: $135.0{\pm}5.1^{\circ}C$, $CaF_2$:Dy: $144.0{\pm}1.6^{\circ}C$, $CaF_2$:Mn: $294.3{\pm}3.8^{\circ}C$, respectively. Because the glow emission probability of the captured electrons depend on the heating temperature after the exposure radiation, TLDs by applying the fixed heating rate, the accuracy of measurement will be able to improve within the absorbed dose measurement of the radiation therapy.

Diagnostic Value of CYFRA 21-1 Measurement in Fine-Needle Aspiration Washouts for Detection of Axillary Recurrence in Postoperative Breast Cancer Patients (유방암 수술 후 액와림프절 재발 진단에 있어서의 미세침세척액 CYFRA 21-1의 진단적 가치)

  • So Yeon Won;Eun-Kyung Kim;Hee Jung Moon;Jung Hyun Yoon;Vivian Youngjean Park;Min Jung Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.81 no.1
    • /
    • pp.147-156
    • /
    • 2020
  • Purpose The objective of this study was to evaluate the diagnostic value and threshold levels of cytokeratin fragment 21-1 (CYFRA 21-1) in fine-needle aspiration (FNA) washouts for detection of lymph node (LN) recurrence in postoperative breast cancer patients. Materials and Methods FNA cytological assessments and CYFRA 21-1 measurement in FNA washouts were performed for 64 axillary LNs suspicious for recurrence in 64 post-operative breast cancer patients. Final diagnosis was made on the basis of FNA cytology and follow-up data over at least 2 years. The concentration of CYFRA 21-1 was compared between recurrent LNs and benign LNs. Diagnostic performance and cut-off value were evaluated using a receiver operating characteristic curve. Results Regardless of the non-diagnostic results, the median concentration of CYFRA 21-1 in recurrent LNs was significantly higher than that in benign LNs (p < 0.001). The optimal diagnostic cut-off value was 1.6 ng/mL. The sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of CYFRA 21-1 for LN recurrence were 90.9%, 100%, 100%, 98.1%, and 98.4%, respectively. Conclusion Measurement of CYFRA 21-1 concentration from ultrasound-guided FNA biopsy aspirates showed excellent diagnostic performance with a cut-off value of 1.6 ng/mL. These results indicate that measurement of CYFRA 21-1 concentration in FNA washouts is useful for the diagnosis of axillary LN recurrence in post-operative breast cancer patients.