• Title/Summary/Keyword: Curve detection

Search Result 866, Processing Time 0.028 seconds

Survey of Aflatoxin B1 in Domestic Doenjang and Kochujang Determined by Enzyme Linked-Immunosorbent Assay (효소면역측정법에 의한 국내산 된장과 고추장 중 Aflatoxin B1의 오염도 조사)

  • Bae, Soo-Ick;Kwak, Bo-Yeon;Park, Yun-Kyung;Kim, Young-Ho;Shon, Dong-Hwa
    • Journal of Food Hygiene and Safety
    • /
    • v.18 no.3
    • /
    • pp.95-100
    • /
    • 2003
  • Competitive direct enzyme-linked immunosorbent assay(cdELISA) of aflatoxin $B_1$ ($AFB_1$) in deonjang(Korean-style soybean paste) and kochujang(fermented hot peppersoybean paste) and the level of $AFB_1$ in modern or traditional style deonjang and gochujang, produced in Korea, was surveyed by cdELISA. From the standard curve of the cdELISA, the detection limit of $AFB_1$ was 0.2 ng/m/. The average recovery of $AFB_1$ was 71.5% in the range of 1~100 ng/g after spiking $AFB_1$ into deonjang and it means that it could be possible to detect the $AFB_1$ in these range by the cdELISA in deonjang. Among the 30 kochujangs tested, no $AFB_1$ was detected in kochujangs. Among the 30 deonjangs, $AFB_1$ was detected in 6 ones in the range of 1.0~6.0 ng/g. The occurrence of $AFB_1$ in deonjang and kochujang tested in this study was less than the Korea Standard and Specification of aflatoxin in foods (10 ppb).

Spectrophotometric Determination of Bisphenol A by Complexation with Ferricyanide and Ferric chloride solution (Ferricyanide와 ferric chloride 혼합액을 사용한 Bisphenol A의 비색 정량법 개발)

  • Kum, Eun-Joo;Ryu, Hee-Young;Kwon, Gi-Seok;Sohn, Ho-Yong
    • Journal of Life Science
    • /
    • v.17 no.2 s.82
    • /
    • pp.266-271
    • /
    • 2007
  • Bisphenol A (BPA) has been widely used as a monomer for production of epoxy resins and polycarbonate plastics. The annual production of BPA exceeds 640,000 metric tons in worldwide. BPA, a suspected phenolic endocrine disrupter, is moderately soluble and frequently detected in industrial wastewater. To date, HPLC and GC has been used for BPA analysis. However, HPLC and GC-analysis need high operation lost, experts, and an elaborate pre-treatment of samples, and is difficult to apply on-time and mass analysis. Therefore, simple, mass and rapid detection of BPA in environments is necessary. In the present study, spectrophotometric method of BPA quantification was developed. Based on blue-color product formation with BPA and ferric chloride/ferricyanide under the optimized conditions, the standard curve was acquired $({\lambda}_{750}=0.061\;BPA\;[{\mu}M]+0.07155,\;R^2=0.992)$. Using an established method, the BPA contents in the soil extract, and different water samples and living products, including disposable syringe, cup and plastic tube, were analyzed. The results suggested that the method is useful for BPA determination from different massive samples. Since the BPA metabolites, nontoxic 4-hydroxyacetophenone or 4-hydroxybenzaldehyde, did not form blue-color product, this method is also useful to screen a microorganism for BPA bioremediation.

Procalcitonin in 2009 H1N1 Influenza Pneumonia: Role in Differentiating from Bacterial Pneumonia (2009 H1N1 인플루엔자 폐렴에서 Procalcitonin의 유용성: 세균성 폐렴과의 감별 역할)

  • Ahn, Shin;Kim, Won-Young;Yoon, Ji-Young;Sohn, Chang-Hwan;Seo, Dong-Woo;Kim, Sung-Han;Hong, Sang-Bum;Lim, Chae-Man;Koh, Youn-Suck;Kim, Won
    • Tuberculosis and Respiratory Diseases
    • /
    • v.68 no.4
    • /
    • pp.205-211
    • /
    • 2010
  • Background: Procalcitonin is a well known marker in infection that plays a role in distinguishing between bacterial and viral infections in screening. The aim of the present study was to evaluate the role of procalcitonin in differentiating between 2009 H1N1 influenza pneumonia and community acquired pneumonia of bacterial origin, or mixed bacterial origin and 2009 H1N1 influenza infection. Methods: A retrospective observational study was performed over the 6-month winter period during the 2009 H1N1 influenza pandemic. Ninety-six patient-subjects were enrolled, all of whom had been diagnosed with community acquired pneumonia in emergency department during the study period. On admission, laboratory studies were performed, which included 2009 H1N1 influenza real-time polymerase chain reaction of nasal secretions and procalcitonin on serum; the laboratory values were compared between the study groups. Receiver operating characteristic curve analyses were performed on the resulting data. Results: Compared to those with bacterial or mixed infections (n=62) and bacterial pneumonia with confirmed organisms (n=30), patients with 2009 H1N1 pneumonia (n=34) were significantly more likely to have low procalcitonin levels (p=0.008, 0.001). Using cutoff of value >0.3 ng/mL, the sensitivity and specificity of procalcitonin for detection of patients with confirmed bacterial pneumonia were 76.2% and 60.6%, respectively. A significant difference in procalcitonin was found between 2009 H1N1 pneumonia and pneumonia caused by mixed influenza viral and bacterial infections (0.15 [0.05~0.84] vs. 10.3 [0.05~22.87] ng/mL, p=0.045). Conclusion: Serum procalcitonin measurement may assist in the discrimination between pneumonia of bacterial and of 2009 H1N1 influenza origin. High values of procalcitonin suggest that bacterial infection or mixed infection of bacteria and 2009 H1N1 influenza is more likely.

Voltammetric Determination of Cu(II) Ion at a Chemically Modified Carbon-Paste Electrode Containing 1-(2-pyridylazo)-2-naphthol (1-(2-Pyridylazo)-2-naphthol 수식전극을 사용한 Cu(II) 이온의 전압전류법적 정량)

  • Jun-Ung Bae;Hee Sook Jun;Hye-Young Jang
    • Journal of the Korean Chemical Society
    • /
    • v.37 no.8
    • /
    • pp.723-729
    • /
    • 1993
  • Cu(II) ion-responsive chemically modifed electrodes (CMEs) were constructed by incorporating 1-(2-pyridylazo)-2-naphthol (PAN) into a conventional carbon-paste mixture of graphite powder and Nujol oil. Cu(II) ion was chemically deposited on the surface of the PAN-chemically modified electrode in the absence of an applied potential by immersion of the electrode in a buffer solution (pH 3.2) containing Cu(II) ion, and then reduced at a constant potential in 0.1 M KNO$_3$. And a well-defined voltammetric peak could be obtained by scanning the potential to the positive direction. The electrode surface could be regenerated with exposure to acid solution and reused for the determination of Cu(II) ion. In 5 deposition / measurement / regeneration cycles, the response could be reproduced with 6.1${\%}$ relative standard deviation. In case of using the differential pulse voltammetry, the calibration curve for Cu(II) was linear over the range of 2.0 ${times}$ 10$^{-7}$ ∼ 1.0 ${times}$ 10$^{-6}$ M. And the detection limit was 6.0 ${times}$ 10$^{-8}$ M. Studies of the effect of diverse ions showed that Co, Ni, Zn, Pb, Mg and Ag ions added 10 times more than Cu(II) ion did not influence on the determination of Cu(II) ion, except EDTA and oxalate ions.

  • PDF

Meat Species Identification using Loop-mediated Isothermal Amplification Assay Targeting Species-specific Mitochondrial DNA

  • Cho, Ae-Ri;Dong, Hee-Jin;Cho, Seongbeom
    • Food Science of Animal Resources
    • /
    • v.34 no.6
    • /
    • pp.799-807
    • /
    • 2014
  • Meat source fraud and adulteration scandals have led to consumer demands for accurate meat identification methods. Nucleotide amplification assays have been proposed as an alternative method to protein-based assays for meat identification. In this study, we designed Loop-mediated isothermal amplification (LAMP) assays targeting species-specific mitochondrial DNA to identify and discriminate eight meat species; cattle, pig, horse, goat, sheep, chicken, duck, and turkey. The LAMP primer sets were designed and the target genes were discriminated according to their unique annealing temperature generated by annealing curve analysis. Their unique annealing temperatures were found to be $85.56{\pm}0.07^{\circ}C$ for cattle, $84.96{\pm}0.08^{\circ}C$ for pig, and $85.99{\pm}0.05^{\circ}C$ for horse in the BSE-LAMP set (Bos taurus, Sus scrofa domesticus and Equus caballus); $84.91{\pm}0.11^{\circ}C$ for goat and $83.90{\pm}0.11^{\circ}C$ for sheep in the CO-LAMP set (Capra hircus and Ovis aries); and $86.31{\pm}0.23^{\circ}C$ for chicken, $88.66{\pm}0.12^{\circ}C$ for duck, and $84.49{\pm}0.08^{\circ}C$ for turkey in the GAM-LAMP set (Gallus gallus, Anas platyrhynchos and Meleagris gallopavo). No cross-reactivity was observed in each set. The limits of detection (LODs) of the LAMP assays in raw and cooked meat were determined from $10pg/{\mu}L$ to $100fg/{\mu}L$ levels, and LODs in raw and cooked meat admixtures were determined from 0.01% to 0.0001% levels. The assays were performed within 30 min and showed greater sensitivity than that of the PCR assays. These novel LAMP assays provide a simple, rapid, accurate, and sensitive technology for discrimination of eight meat species.

Estimation of Estrogenic Activity by E-screen Assay and Stepwise Analysis of Endocrine Disruptors in Pilot Sewage Treatment Plant (파일럿 규모의 하수 처리 공정별 E-screen Assay에 의한 에스트로겐 활성과 내분비계 장애물질의 농도 평가)

  • Lee, Ji-Ho;Park, Jong-Yol;Ra, Jin-Sung;Duong, Cuong N.;Lee, Byoung-Cheun;Kim, Sang-Don
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.7
    • /
    • pp.697-703
    • /
    • 2006
  • Endocrine disruptors were measured with GC/MS in effluents discharged from sewage treatment processes in pilot scale for the purpose of water reuse. From that analysis, we compared the removal rate of them by treatment processes. Nonylphenol was mainly detected in effluents and high concentration from 0.36 to 0.94 ${\mu}g/L$. $17{\beta}$-estradiol(E2) and $17{\alpha}$-ethynylestradiol(EE2) were detected as below the limit of detection in effluent. Endocrine disruptors were removed effectively in the range from 50 to 100% by treatment process. EC50 value($9.0{\times}10^{-3}$ M) of $17{\beta}$-estradiol(E2) by dose response curve of E-screen assay has higher than that of bisphenol A($2.736{\times}10^{-5}M$) and p-octylphenol($9.760{\times}10^{-6}$ M). These results showed that alkylphenols have lower relative estrogen potency than other estrogens such as $17{\beta}$-estradiol(E2). Calculated estrogenic activity(ng-EEQ/L) was 2 times higher than measured total estrogenic activity which estimated by E-screen assay. Moreover estrogenic activity of effluent by treatment process showed very low as below 1 ng-EEQ/L.

Extensive Hepatic Uptake of Pz-peptide, a Hydrophilic Proline-Containing Pentapeptide, into Isolated Hepatocytes Compared with Colonocytes and Caco-2 Cells

  • Shin, Tae-Ha;Lee, Pung-Sok;Kwon, Oh-Seung;Chung, Youn-Bok
    • Archives of Pharmacal Research
    • /
    • v.26 no.1
    • /
    • pp.70-75
    • /
    • 2003
  • The objective of the present study was to investigate the uptake process of 4-Phenylazobenzoxycarbonyl-Pro-Leu-Gly-Pro-D-Arg (Pz-peptide), a hydrophilic and collagenase-labile pentapeptide, by isolated hepatocytes. For comparison, the uptake of Pz-peptide by Caco-2 cells and colonic cells, two known paracellular routes of Pz-peptide, was also evaluated. A simple and sensitive reversed-phase HPLC assay method using UV detection has been developed. The coefficient of variation for all the criteria of validation were less than 15%. The method was, therefore, considered to be sutable for measuring the concentration of Pz-peptide in the biological cells. Pz-peptide was extensively uptaked into hepatocytes. The initial velocity of Pz-peptide uptake assessed from the initial slope of the curve was plotted as Eadie-Hofstee plots. The maximum velocity ($V_{max}$) and the Michaelis constant ($K_m$) were 0.190$\pm$0.020 $nmol/min/10^6$ cells and 12.1$\pm$3.23 $\mu$M, respectively. The permeability-surface area product ($PS{influx}$) was calculated to be 0.0157 ml/min/10^6$ cells. $V_{max}$ and $K_m$ values for Caco-2 cells were calculated to be 6.22$\pm$0.930 pmol/min/10^6$ cells and 82.8$\pm$8.37 $\mu$M, respectively, being comparable with those of colonocytes (6.04$\pm$1.03 pmol/min/10^6$ cells and 87.8$\pm$13.2 $\mu$M, respectively). $PS_{influx}$ values for Caco-2 cells and colonocytes were calculated to be 0.0751 $\mu$l/min/10^6$ cells and 0.0688 $\mu$l/min/10^6$ cells, respectively. The more pronounced uptake of Pz-peptide by hepatocytes, when compared with Caco-2 cells and colonocytes, is probably due to its specific transporter. In conclusion, Pz-peptide, a paracellularly transported pentapeptide in the intestine and ocular epithelia, was uptaked into hepatocytes extensively. Although Pz-peptide is able to be uptaked into the Caco-2 cells and colonocytes, it is less pronounced when compared with hepatocytes. $PS_{influx}$ values of Caco-2 cells and colonocytes for unbound Pz-peptide under linear conditions were less than 0.4% when compared with that of hepatocytes.

Bioequivalence Evaluation of Lovastatin Tablets (로바스타틴 정제의 생물학적 동등성 평가)

  • Bok, Hae Sook;Kim, Myoung Min;Choi, Kyung Eob
    • Korean Journal of Clinical Pharmacy
    • /
    • v.8 no.2
    • /
    • pp.107-112
    • /
    • 1998
  • Lovastatin is a lipid lowering agent for the treatment of hypercholesterolemia and belongs to a new class of pharmacologic compounds called the 3-hydroxy-3-methylglutaryl coenzyme A (HMG CoA) reductase inhibitors. By competitively inhibiting HMG CoA reductase, lovastatin disrupts the biosynthesis of cholesterol in hepatic and peripheral cells and increases the synthesis of high-density-lipoprotein HDL) receptors. Following oral administration, the lactone ring of lovastatin is hydrolysed to the active inhibitor of HMG CoA reductase, lovastatin acid. Lovastatin is known to have poor oral absorption and wide individual variation. In this study, bioequivalence test of two lovastatin formulations, the test drug ($Lovaload^{TM}$, Chong Kun Dang Pharmaceutical Co.) and the reference drug ($Mevacor^{TM}$, Chung Wae Pharmaceutical Co.) were conducted according to the guidelines of Korea Food and Drug Administration (KFDA). A total of 18 healthy male volunteers, $31.90\pm3.60$ years old and $72.17\;7.88$ kg of body weight in average, were evaluated in a randomized crossover manner with a 2-week washout period. Concentrations of lovastatin acid in plasma were measured upto 12 hours following a single oral administration of eight tablets (20 mg of lovastatin per tablet) by high-performance liquid chromatography with UV detection at 238 nm. The area under the concentration-vs-time curve from 0 to 12 hours $(AUC_{0-12h})$ was calculated by the trapezoidal summation method. The statistical analysis showed that there are no significant differences in $AUC_{0-12h),\;C_{max}\;and\;T_{max}$ between the two formulations ($6.72\%,\;1.52\%,\;and\;0.88\$, respectively). The least significant differences between the formulations at $\alpha$=0.05 were less than $20\%\;(11.65\%,\;19.73\%,\;and\;14.81\%\;for\;AUC_{0-12h},\;C_{max}\;and\;T_{max}$, respectively). The $90\%$ confidence intervals for these parameters were also within $\pm20\%\;(-1.50{\leq}{\delta}{\leq}15.00$, $-12.50{\leq}{\delta}{\leq}15.50,\;and\;-9.64{\leq}{\delta]{\leq}11.40{\leq}\;for\;\;AUC_{0-12h}$ ,$C_{max}\;and\;T_{max}$, respectively). In conclusion, the new generic product $Lovaload^{TM}$ was proven to be bioequivalent with the reference drug.

  • PDF

Analytical Method Validation of Quercetin in Changnyeong Onion Extract as a Functional Ingredient for Functional Health Food (건강기능식품 기능성원료로서 창녕양파추출액의 지표성분 Quercetin 분석법)

  • Jeon, Seon-Young;Jeong, Eun-Jeong;Baek, Jeong-Hwa;Cha, Yong-Jun
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.40 no.4
    • /
    • pp.565-569
    • /
    • 2011
  • Validation of quercetin as a marker compound in the standardization of Changnyeong onion extract developed for functional health food was attempted by analytical method. The specificity was satisfied with retention time and photo diode array (PDA) spectrum by analysis of quercetin using HPLC and comparison with standard compound. It showed a high linearity in the calibration curve as coefficient of correlation ($R^2$) of 0.9986, and the limit of detection (LOD) and limit of quantitation (LOQ) were 0.2 mg/L and 0.5 mg/L, respectively. Recovery rate test with quercetin concentration of 0.05, 0.075 and 0.1 mg/mL was revealed in the high range of 82.36~95.26%, 82.70~98.24% and 87.91~95.11%, respectively. The intra-day and inter-day precision in quercetin for Changnyeong onion extracts was 0.10~3.28% and 0.96~5.79%, respectively. Therefore, application of quercetin was validated in analytical method as a marker compound in Changnyeong onion extracts.

Matrix Modification for Atomic Absorption Spectrophotometric Determination of Volatile Elements (Ⅱ). Determination of Trace Germanium by Electrothermal Atomization (휘발성 원소들의 원자흡수 분광분석을 위한 매트릭스 개선에 관한 연구(제2보). 전열 원자화에 의한 흔적량 게르마늄의 정량)

  • Choi, Ho Sung;Choi, Jong Moon;Kim, Young Sang
    • Journal of the Korean Chemical Society
    • /
    • v.40 no.2
    • /
    • pp.109-116
    • /
    • 1996
  • A matrix modification was studied for the determination of trace germanium in mineral waters by electrothermal atomic absorption spectrophotometry (ET-AAS). For this, the type and quantity of modifier as well as the use of auxiliary modifier were investigated to realize the efficient modification. Germanium suffers from low sensitivity and poor reproducibility in ET-AAS determination because of the premature loss of germanium via volatile germanium monoxide formation when heated in the presence of carbon. Therefore, the addition of a matrix modifier is necessary to stablize the germanium, thermally and chemically. By the addition of palladium (10 ${\mu}g/mL)$ as a single modifier to the sample containing 500 ng/mL germanium, the charring temperature could be raised from 800 to $1000^{\circ}C$, and its absorbance was also increased, but the atomization temperature was not raised. In this case, the absorbance of germanium was not changed in the range of 10∼70 ${\mu}g/mL$ of palladium added. On the other hand, it was considered that the use of a mixed modifier could modifiy the matrix more effectively than with a single modifier. The best results were obtained by using 1% ammonium hydroxide as an auxiliary modifier together with 10 ${\mu}g/mL$ palladium. The charring temperature could be raised from 800 to $1100^{\circ}C$, without any change of the atomization temperature. With above optimum conditions, the trace amount of germanium in several mineral waters were determined by a calibration curve method, and good recoveries of more than 95% were also obtained in the samples in which a given amount of germanium was spiked. The detection limit of this method was about 6.9 ng/mL.

  • PDF