• Title/Summary/Keyword: Curve detection

Search Result 861, Processing Time 0.03 seconds

Detecting width-wise partial delamination in the composite beam using generalized fractal dimension

  • Kumar, S. Keshava;Ganguli, Ranjan;Harursampath, Dineshkumar
    • Smart Structures and Systems
    • /
    • v.19 no.1
    • /
    • pp.91-103
    • /
    • 2017
  • Generalized fractal dimension is used to detect the presence of partial delamination in a composite laminated beam. The effect of boundary conditions and location of delamination on the fractal dimension curve is studied. Appropriability of higher mode shape data for detection of delamination in the beam is evaluated. It is shown that fractal dimension measure can be used to detect the presence of partial delamination in composite beams. It is found that the torsional mode shape is well suited for delamination detection in beams. First natural frequency of delaminated beam is found to be higher than the healthy beam for certain small and partial width delaminations and some boundary conditions. An explanation towards this counter intuitive phenomenon is provided.

Advanced insider threat detection model to apply periodic work atmosphere

  • Oh, Junhyoung;Kim, Tae Ho;Lee, Kyung Ho
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.13 no.3
    • /
    • pp.1722-1737
    • /
    • 2019
  • We developed an insider threat detection model to be used by organizations that repeat tasks at regular intervals. The model identifies the best combination of different feature selection algorithms, unsupervised learning algorithms, and standard scores. We derive a model specifically optimized for the organization by evaluating each combination in terms of accuracy, AUC (Area Under the Curve), and TPR (True Positive Rate). In order to validate this model, a four-year log was applied to the system handling sensitive information from public institutions. In the research target system, the user log was analyzed monthly based on the fact that the business process is processed at a cycle of one year, and the roles are determined for each person in charge. In order to classify the behavior of a user as abnormal, the standard scores of each organization were calculated and classified as abnormal when they exceeded certain thresholds. Using this method, we proposed an optimized model for the organization and verified it.

P Wave Detection based on QRST Cancellation Zero-One Substitution

  • Cho, Ik-Sung
    • Journal of information and communication convergence engineering
    • /
    • v.19 no.2
    • /
    • pp.93-101
    • /
    • 2021
  • Cardiac arrhythmias are common heart diseases and generally cause sudden cardiac death. Electrocardiogram (ECG) is an effective tool that can reveal the electrical activity of the heart and diagnose cardiac arrhythmias. We propose detection of P waves based on QRST cancellation zero-one substitution. After preprocessing, the QRST segment is determined by detecting the Q wave start point and T wave end point separately. The Q wave start point is detected by digital analyses of the QRS complex width, and the T wave end point is detected by computation of an indicator related to the area covered by the T wave curve. Then, we determine whether the sampled value of the signal is in the interval of the QRST segment and substitute zero or one for the value to cancel the QRST segment. Finally, the maximum amplitude is selected as the peak of the P wave in each RR interval of the residual signal. The average detection rate for the QT database was 97.67%.

An electrochemical hydrogen peroxide sensor for applications in nuclear industry

  • Park, Junghwan;Kim, Jong Woo;Kim, Hyunjin;Yoon, Wonhyuck
    • Nuclear Engineering and Technology
    • /
    • v.53 no.1
    • /
    • pp.142-147
    • /
    • 2021
  • Hydrogen peroxide is a radiolysis product of water formed under gamma-irradiation; therefore, its reliable detection is crucial in the nuclear industry for spent fuel management and coolant chemistry. This study proposes an electrochemical sensor for hydrogen peroxide detection. Cysteamine (CYST), gold nanoparticles (GNPs), and horseradish peroxidase (HRP) were used in the modification of a gold electrode for fabricating Au/CYST/GNP/HRP sensor. Each modification step of the electrode was investigated through electrochemical and physical methods. The sensor exhibited strong sensitivity and stability for the detection and measurement of hydrogen peroxide with a linear range of 1-9 mM. In addition, the Michaelis-Menten kinetic equation was applied to predict the reaction curve, and a quantitative method to define the dynamic range is suggested. The sensor is highly sensitive to H2O2 and can be applied as an electrochemical H2O2-sensor in the nuclear industry.

Rapid Detection of Salmonella spp. in Fresh-Cut Cabbage by Real-Time PCR (Real-Time PCR을 이용한 신선편이 양배추에서 Salmonella spp.의 신속검출)

  • Bang, Mi-Kyung;Park, Seung-Ju;Kim, Yun-Ji;Kim, Ji-Gang;Oh, Se-Wook
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.39 no.10
    • /
    • pp.1522-1527
    • /
    • 2010
  • This study was conducted to find out the minimal time needed for detection of Salmonella spp. which exist at very low concentration in foods by using real-time PCR. The sal-F and sal-R sequences were used as primers and sal-P was used as a probe. The detection limit of Salmonella spp. was $3.77{\times}10^2\;cfu/mL$ in buffered peptone water (BPW). Microbial growth was monitored after artificially inoculated Salmonella spp. into BPW. The obtained growth curve was well fitted with the equation, y=$0.0127x^2$+0.5927x-0.4317 ($R^2$=0.99), if assuming that 1 cell exists in 25 g sample (0.04 cfu/mL). The microbial concentration will be reduced to 10 fold by adding BPW during sample treatment, so actual initial concentration at the starting point of enrichment is 0.004 cfu/mL. At this condition, real-time PCR detection would be possible only when microbial concentration increase occurs to exceed the detection limit (377 cfu/mL). The time needed for microbial increase was calculated from the growth curve equation as 7 hours and 20 minutes. Therefore the total time required for detection was less than 10 hours including the PCR operating time.

A Facile Electrochemical Fabrication of Reduced Graphene Oxide-Modified Glassy Carbon Electrode for Simultaneous Detection of Dopamine, Ascorbic Acid, and Uric Acid

  • Yu, Joonhee;Kim, Tae Hyun
    • Journal of Electrochemical Science and Technology
    • /
    • v.8 no.4
    • /
    • pp.274-281
    • /
    • 2017
  • This paper describes the simple fabrication of an electrode modified with electrochemically reduced graphene oxide (ERGO) for the simultaneous electrocatalytic detection of dopamine (DA), ascorbic acid (AA), and uric acid (UA). ERGO was formed on a glassy carbon (GC) electrode by the reduction of graphene oxide (GO) using linear sweep voltammetry. The ERGO/GC electrode was formed by subjecting a GO solution ($1mg\;mL^{-1}$ in 0.25 M NaCl) to a linear scan from 0 V to -1.4 V at a scan rate of $20mVs^{-1}$. The ERGO/GC electrode was characterized by Raman spectroscopy, Fourier transform infrared spectroscopy, contact angle measurements, electrochemical impedance spectroscopy, and cyclic voltammetry. The electrochemical performance of the ERGO/GC electrode with respect to the detection of DA, AA, and UA in 0.1 M PBS (pH 7.4) was investigated by differential pulse voltammetry (DPV) and amperometry. The ERGO/GC electrode exhibited three well-separated voltammetric peaks and increased oxidation currents during the DPV measurements, thus allowing for the simultaneous and individual detection of DA, AA, and UA. The detection limits for DA, AA, and UA were found to be 0.46, 77, and $0.31{\mu}M$ respectively, using the amperometric i-t curve technique, with the S/N ratio being 3.

An adaptive method of multi-scale edge detection for underwater image

  • Bo, Liu
    • Ocean Systems Engineering
    • /
    • v.6 no.3
    • /
    • pp.217-231
    • /
    • 2016
  • This paper presents a new approach for underwater image analysis using the bi-dimensional empirical mode decomposition (BEMD) technique and the phase congruency information. The BEMD algorithm, fully unsupervised, it is mainly applied to texture extraction and image filtering, which are widely recognized as a difficult and challenging machine vision problem. The phase information is the very stability feature of image. Recent developments in analysis methods on the phase congruency information have received large attention by the image researchers. In this paper, the proposed method is called the EP model that inherits the advantages of the first two algorithms, so this model is suitable for processing underwater image. Moreover, the receiver operating characteristic (ROC) curve is presented in this paper to solve the problem that the threshold is greatly affected by personal experience when underwater image edge detection is performed using the EP model. The EP images are computed using combinations of the Canny detector parameters, and the binaryzation image results are generated accordingly. The ideal EP edge feature extractive maps are estimated using correspondence threshold which is optimized by ROC analysis. The experimental results show that the proposed algorithm is able to avoid the operation error caused by manual setting of the detection threshold, and to adaptively set the image feature detection threshold. The proposed method has been proved to be accuracy and effectiveness by the underwater image processing examples.

Fake News Detection on Social Media using Video Information: Focused on YouTube (영상정보를 활용한 소셜 미디어상에서의 가짜 뉴스 탐지: 유튜브를 중심으로)

  • Chang, Yoon Ho;Choi, Byoung Gu
    • The Journal of Information Systems
    • /
    • v.32 no.2
    • /
    • pp.87-108
    • /
    • 2023
  • Purpose The main purpose of this study is to improve fake news detection performance by using video information to overcome the limitations of extant text- and image-oriented studies that do not reflect the latest news consumption trend. Design/methodology/approach This study collected video clips and related information including news scripts, speakers' facial expression, and video metadata from YouTube to develop fake news detection model. Based on the collected data, seven combinations of related information (i.e. scripts, video metadata, facial expression, scripts and video metadata, scripts and facial expression, and scripts, video metadata, and facial expression) were used as an input for taining and evaluation. The input data was analyzed using six models such as support vector machine and deep neural network. The area under the curve(AUC) was used to evaluate the performance of classification model. Findings The results showed that the ACU and accuracy values of three features combination (scripts, video metadata, and facial expression) were the highest in logistic regression, naïve bayes, and deep neural network models. This result implied that the fake news detection could be improved by using video information(video metadata and facial expression). Sample size of this study was relatively small. The generalizablity of the results would be enhanced with a larger sample size.

Detection of MicroRNA-21 Expression as a Potential Screening Biomarker for Colorectal Cancer: a Meta-analysis

  • Jiang, Jian-Xin;Zhang, Na;Liu, Zhong-Min;Wang, Yan-Ying
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.18
    • /
    • pp.7583-7588
    • /
    • 2014
  • Background: Colorectal cancer (CRC) is a major cause of cancer-related death and cancer-related incidence worldwide. The potential of microRNA-21 (miR-21) as a biomarker for CRC detection has been studied in several studies. However, the results were inconsistent. Therefore, we conducted the present meta-analysis to systematically assess the diagnostic value of miR-21 for CRC. Materials and Methods: Using a random-effect model, the pooled sensitivity (SEN), specificity (SPE), positive likelihood ratio (PLR), negative likelihood ratio (NLR), and diagnostic odds ratio (DOR) were calculated to evaluate the diagnostic performance of miR-21 for CRC. A summary receiver operating characteristic (SROC) curve and an area under the curve (AUC) were also generated to assess the diagnosis accuracy of miR-21 for CRC. Q test and I2 statistics were used to assess between-study heterogeneity. Publication bias was evaluated by the Deeks' funnel plot asymmetry test. Results: A total of 986 CRC patients and 702 matched healthy controls from 8 studies were involved in the meta-analysis. The pooled results for SEN, SPE, PLR, NLR, DOR, and AUC were 57% (95%CI: 39%-74%), 87% (95%CI: 78%-93%), 4.4 (95%CI: 2.4-8.0), 0.49 (95%CI: 0.32-0.74), 9 (95%CI: 4-22), and 0.83 (95%CI: 0.79-0.86), respectively. Subgroup analyses further suggested that blood-based studies showed a better diagnostic accuracy compared with feces-based studies, indicating that blood may be a better matrix for miR-21 assay and CRC detection. Conclusions: Our findings suggest that miR-21 has a potential diagnostic value for CRC with a moderate level of overall diagnostic accuracy. Hence, it could be used as auxiliary means for the initial screening of CRC and avoid unnecessary colonoscopy, which is an invasive and expensive procedure.

Monitoring on the Foods not Approved for Irradiation in Korea by PSL and TL Detection Method (광자극발광법과 열발광법을 이용한 국내 방사선 조사 허용 외 식품에 대한 실태 조사)

  • Cho, Joon-Il;Lee, Ji-Ae;Lee, Soon-Ho;Hwang, In-Gyun
    • Journal of Food Hygiene and Safety
    • /
    • v.25 no.1
    • /
    • pp.73-78
    • /
    • 2010
  • This research was conducted to assess applicability of photostimulated luminescence (PSL) and Thermoluminescence (TL) methods for investigation of infant and young children products, nut, seasoned dried fish, spice, dried fruits, fruit & vegetable, grain and marine products, which are not approved for irradiation in Korea. PSL results show that the photon counts of non-irradiated samples were lower than 700, while those of irradiated samples were higher than 700. In TL measurement, TL ratio of irradiated samples were higher than 0.1 or ones can decrease below 0.1 whereas the temperature range of TL Glow curve was between $150{\sim}250^{\circ}C$. Monitoring result about 8 class of 325 not approved to irradiated foods, photon counts of samples were less than 700, and after re-irradiation TL Ratio ($TL_1/TL_2$) through re-irradiation step at 1 kGy were higher than 0.1 for the all samples. Therefore, these results suggested that PSL and TL measurements were useful detection methods for 8 class food products not approved to irradiation in Korea and all sample (325 cases) were not irradiated when we analysed by PSL and TL methods.