• 제목/요약/키워드: Curvature Measurement

검색결과 219건 처리시간 0.025초

거북목증후군의 경추만곡 호전에 대한 봉추나요법과 침술의 효과와 방사선학적 평가방법 연구 (Clinical Effect of Bong Chuna Manual Therapy and Acupunture Treatment for Improving Cervical Curvature of Turtle Neck Syndrome and Measurement Method of Radiography)

  • 오원교;이유진;신병철
    • 한방재활의학과학회지
    • /
    • 제19권1호
    • /
    • pp.113-124
    • /
    • 2009
  • Objectives : The aim of this study was to observe the effect of Bong Chuna manual therapy(BCMT) and acupuncture on the Turtle Neck Syndrome(TNS) by the changes of radiological findings and symptoms. Methods : Total twenty-eight patients diagnosed as TNS were evaluated. Twenty patients in experimental group were treated by the combination of BCMT and acupuncture, eight patients in control group were treated by acupuncture only. We measured VAS(Visual analogue scale) as pain intensity and Neck Pain and Disability Scale(NDI) at pre- and post-treatment. Also the four line Cobb's method and Jochumsen method were assessed for evaluating the radiographical changes, additionally we used 'two line method'. Results : VAS score showed statistically significant reduction in pain intensity in both experimental group and control group after 8 weeks treatment, $-44.05{\pm}14.91$ vs $-23.75{\pm}14.08$ respectively. Also NDI score presented $-11.40{\pm}8.63$ reduction in experimental group, and it was significant statistically, however not in control group, $-8.63{\pm}9.84$ reduction after 8weeks treatment. In radiological findings, the four line Cobb's method, Jochumsen method and two line method were reduced after 8weeks treatment, $-9.30{\pm}10.33$, $-0.65{\pm}1.72$ and $-14.35{\pm}5.68$ in experimental group respectively, $-0.75{\pm}1.91$, $-0.25{\pm}0.71$ and $0.38{\pm}2.20$ in control group respectively. However they were statistical significance only in the four line Cobb's method and two line method in both group. Conclusions : Combination treatment of CMT and acupuncture showed better effect on pain reduction, VAS score and the correction of neck anteversion than acupuncture only in TNS. Two line method seems valuable for evaluating the improvement of radiographical changes in TNS.

PVDF 압전막을 이용한 초고주파 집속 초음파 트랜스듀서의 제작 및 특성 평가 (Fabrication and Evaluation of a VHF Focusing Ultrasonic Transducer Made of PVDF Piezoelectric Film)

  • 윤주호;오정환;김정순;김무준;하강렬
    • 한국음향학회지
    • /
    • 제30권4호
    • /
    • pp.215-222
    • /
    • 2011
  • 높은 분해능의 영상을 얻는데 사용하기 위하여 초고주파 대역에서 동작하는 집속 초음파 트랜스듀서를 제작하고 그 특성을 평가하였다. 그 트랜스듀서는 한쪽 면에만 접지용 전극이 있는 두께 9 ${\mu}m$의 PVDF 압전막의 다른 쪽 면에 CCP (Copper Clad Polyimide)막을 에폭시로 접착한 후, 금속구로 압착함에 의해 구각형을 형성시키고, 그 뒷면에 에폭시를 채워 몰딩 시키는 방법에 의해 만들어졌다. 제작된 곡률반경 7.5 mm, f-number 1.7의 트랜스듀서는 초점에 있는 표적에 대한 펄스에 코 측정결과 35.0 MHz의 대역폭을 가지며, 약 40 MHz인 피크주파수 부근에서의 삽입손실은 약 60 dB 을 나타내었는데, 그 측정결과는 에폭시 접착층의 두께를 고려한 KLM 등가회로 해석에 의한 시뮬레이션 결과와 유사한 것이었다. 나아가, 그 트랜스듀서에 의해 얻어진 가는 구리선 표적에 대한 영상을 35 MHz 트랜스듀서를 장착한 UBM (Ultrasonic Backscattering Microscope) 장치에 의한 영상과 비교한 결과, 측방향 분해능은 떨어지나 축방향 분해능은 다소 향상됨을 알 수 있었다.

소프트콘택트렌즈의 유형에 따른 각막형태의 변화 (Change of Corneal Shape with Soft Contact Lens Type)

  • 우철민;이현미
    • 한국안광학회지
    • /
    • 제19권1호
    • /
    • pp.111-120
    • /
    • 2014
  • 목적: 콘택트렌즈의 함수율, 재질, 굴절력의 차이에 따른 착용전후의 각막의 형태 변화를 살펴보고자 하였다. 방법: 5가지 유형의 콘택트렌즈를 사용하여 렌즈 착용 전후의 두께차이를 비교하였다. 각막의 중심부와 각막 중심에 떨어진 거리와 방향에 따른 렌즈 착용 전, 후의 각막의 두께, 각막 전, 후면 곡률, 고위수차의 변화를 조사하였다. 측정에 사용된 장비로는 ORB ScanII(Bausch & Lomb Inc, ver 3.14)로 각막 지형도 및 각막 두께를 측정하였으며, 고위수차(high order aberration) 분석을 위하여 Zywave(Bausch & Lomb Inc, ver 5.20)를 사용 하였다. 결과: 산소투과가 낮은 하이드로겔 재질의 소프트 콘택트렌즈(T2 lens)에서 각막의 두께가 증가하는 경향이 두드러지게 나타났다. 각막 중심에서 가장 많은 변화를 보였으며, 중심에 가까울수록 변화정도가 증가하였다. 각막의 방향에 있어서는 코 쪽이 가장 많이 변하였다. 결론: 본 연구에서 사용한 함수율, 재질, 디자인이 다른 5종의 콘택트렌즈 중 Dk가 28이상의 산소투과도를 가진 렌즈에서는 각막의 형태 변화가 적었으며, 산소투과도가 매우 낮은 렌즈에서 가장 많은 각막형태의 변화가 나타났다.

3차원 안면자동분석 사상체질진단기의 Hardware 오차분석 (An Error Analysis of the 3D Automatic Face Recognition Apparatus (3D-AFRA) Hardware)

  • 곽창규;석재화;송정훈;김현진;황민우;유정희;고병희;김종원;이의주
    • 사상체질의학회지
    • /
    • 제19권2호
    • /
    • pp.22-29
    • /
    • 2007
  • 1. Objectives Sasang Contitutional Medicine, a part of the traditional Korean medical lore, treats illness through a constitutional typing system that categorizespeople into four constitutional types. A few of the important criteria for differentiating the constitutional types are external appearances, inner state of mind, and pathological patterns. We had been developing a 3D Automatic Face Recognition Apparatus (3D-AFRA) in order to evaluate the external appearances with more objectivity. This apparatus provides a 3D image and numerical data on facial configuration, and this study aims to evaluate the mechanical accuracy of the 3D-AFRA hardware. 2. Methods Several objects of different shapes (cube, cylinder, cone, pyramid) were each scanned 10 times using the 3D Automatic Face Recognition Apparatus (3D-AFRA). The results were then compared and analyzed with data retrieved through a laser scanner known for its high accuracy. The error rates were analyzed for each grid point of facial contour scanned with Rapidform2006 (Rapidform2006 is a 3D scanning software that collects grid point data for contours of various products and products and product parts through 3D scanners and other 3D measuring devices; the grid point data thusly acquired is then used to reconstruct highly precise polygon and curvature models). 3. Results and Conclusions The average error rate was 0.22mm for the cube, 0.22mm for the cylinder, 0.125mm for the cone, and 0.172mm for the pyramid. The visual data comparing error rates for measurement figures retrieved with Rapidform2006 is shown in $Fig.3{\sim}Fig.6$. Blue tendency indicates smaller error rates, while red indicates greater error rates The protruding corners of the cube display red, indicating greater error rates. The cylinder shows greater error rates on the edges. The pyramid displays greater error rates on the base surface and around the vertex. The cone also shows greater error around the protruding edge.

  • PDF

서울시 지하철 2호선 본선구간의 입자상물질 농도 특성 및 미세분진의 오염지도 개발 (Characterizing Par ticle Matter on the Main Section of the Seoul Subway Line-2 and Developing Fine Particle Pollution Map)

  • 이은선;박민빈;이태정;김신도;박덕신;김동술
    • 한국대기환경학회지
    • /
    • 제32권2호
    • /
    • pp.216-232
    • /
    • 2016
  • In present, the Seoul City is undergoing traffic congestion problems caused by rapid urbanization and population growth. Thus the City government has reorganized the mass transportation system since 2004 and the subway has become a very important means for public transit. Since the subway system is typically a closed environment, the indoor air quality issues have often raised by the public. Especially since a huge amount of PM (particulate matter) is emitted from ground tunnels passing through the subway train, it is now necessary to assess the characteristics and behaviors of fine PM inside the tunnel. In this study, the concentration patterns of $PM_1$, $PM_{2.5}$, and $PM_{10}$ in the Seoul subway line-2 were analyzed by real-time measurement during winter (Jan 13, 2015) and summer (Aug 7, 2015). The line-2 consisting of 51 stations is the most busy circular line in Seoul having the railway of 60.2 km length. The the one-day average $PM_{10}$ concentrations were $148{\mu}g/m^3$ in winter and $66.3{\mu}g/m^3$ in summer and $PM_{2.5}$ concentrations were $118{\mu}g/m^3$ and $58.5{\mu}g/m^3$, respectively. The $PM_{2.5}/PM_{10}$ ratio in the underground tunnel was lower than the outdoor ratio and also the ratio in summer is higher than in winter. Further the study examined structural types of underground subsections to explain the patterns of elevated PM concentrations in the line-2. The subsections showing high PM concentration have longer track, shorter curvature radius, and farther from the outdoor stations. We also estimated the outdoor PM concentrations near each station by a spatial statistical analysis using the $PM_{10}$ data obtained from the 40 Seoul Monitoring Sites, and further we calculated $PM_{2.5}/PM_{10}$ and $PM_1/PM_{10}$ mass ratios near the outdoor subway stations by using our observed outdoor $PM_1$, $PM_{2.5}$, and $PM_{10}$ data. Finally, we could develop pollution maps for outdoor $PM_1$ and $PM_{2.5}$ near the line-2 by using the kriging method in spatial analysis. This methodology may help to utilize existing $PM_{10}$ database when managing and control fine particle problems in Korea.

Transparent resin block을 이용한 K3, NRT, PROFILE의 apical transportation 및 working length 변화양상의 비교 (Comparison of apical transportation and change of working length in K3, NRT AND PROFILE rotary instruments using transparent resin block)

  • 윤민정;송민주;신수정;김의성
    • Restorative Dentistry and Endodontics
    • /
    • 제36권1호
    • /
    • pp.59-65
    • /
    • 2011
  • 연구목적: 본 연구의 목적은 서로 다른 기하학적 형태를 가진 3가지 Ni-Ti 파일, 즉 K3, NRT, Profle을 사용하여 레진 블록으로 제작된 만곡 근관에서의 apical transportation 양상 및 working length 변화를 서로 비교하는 것이다. 연구 재료 및 방법: 실험 방법은 30개의 레진 블록을 Schneider technque을 사용하여 만곡도 측정 후 각 group당 임의로 10개씩 배분하였다. 이를 각 Ni-Ti 파일을 사용하여 crown down technique으로 근관 성형하였다. 이의 분석을 위해 double radiograph superimposition method (Backman CA 1992)를 사용하고, 분석의 정확성과 일관성을 위해 특별히 고안된 jig, digital X-ray 및 apical transportation의 측정 시 CAD/CAM software를 이용하였다. Apical transportation 양은 '근단공-0.5 mm'부위로부터 0, 1, 3, 5 mm에서 측정 하였으며, working length 변화는 근관 성형 전후의 working length 변화를 측정하였다. 또 통계 처리는 각 group의 apical transportation 양과 working length 변화를 Kruskal-Wallis One Way Analysis로 분석 후 다중 비교는 Mann-Whitney U-test를 사용하였다. 결과: 각 group간 working lengh 변화 및 0, 1, 3 mm 부위에서의 apical transportation 측정 값 사이에는 유의할만한 차이가 관찰되지 않았으나(p = 0.924), 5 mm 부위에서는 K3와 Profile사이에 유의할 만한 차이가 있었다(p = 0.027). 결론: 서로 다른 기하학적인 형태를 가진 3가지 Ni-Ti 파일의 apical transportation 및 working length 변화 정도 평가시, 본 연구의 범위 내에서는 3가지 파일 모두 유의할 만한 차이를 보이지 않은 가운데 본래의 근관 형태를 잘 유지한다고 할 수 있다.

이중 정합법을 이용한 볼록비구면 반사경의 형상 오차 측정 (Surface-error Measurement for a Convex Aspheric Mirror Using a Double-stitching Method)

  • 김고은;이윤우;양호순
    • 한국광학회지
    • /
    • 제32권6호
    • /
    • pp.314-322
    • /
    • 2021
  • 일반적인 반사식 망원경은 오목 형태의 주경과 볼록 형태의 부경으로 구성되어 있다. 주경은 크기가 크지만 빛을 모아주는 특성으로 반사경의 파면오차 측정이 비교적 용이하다. 반면에 부경은 빛을 퍼트리기 때문에 주경보다 크기는 작지만 측정의 난이도는 더 높다고 할 수 있다. 특히 코시(Korsch) 형태의 망원경에서는 부경의 가운데 영역도 사용하는데 기존의 힌들(Hindle) 측정법으로는 가운데 부분을 측정할 수 없다. 본 논문에서는 크기가 큰 볼록비구면을 측정하기 위해 힌들 정합법(힌들 측정법과 정합법의 결합)을 적용하여 측정하고 이 측정에서 빠지는 가운데 영역은 일반간섭계의 구면파를 이용해 측정하여 두 결과를 합쳐 전체 형상 오차를 획득하는 방법을 제안하고자 한다. 제안한 방법으로 직경 202 mm, 곡률 반경 499 mm, 비구면상수 -4.613의 볼록 비구면의 형상 오차를 측정한 결과 19.5±1.3 nm rms로 측정되었다. 이 결과는 상용 정합 측정 장비로 측정한 결과와 0.7 nm rms의 근소한 차이를 보였고 반사경의 형상 오차가 45도 방향 비점수차를 가지는 것것도 일치하였다. 따라서 본 논문에서 제안한 방법이 볼록 비구면의 전체 영역을 정밀하게 측정하는데 유용함을 알 수 있었다.

UHPC 비정형 패널 제작 시 수화열에 의한 PCM 거푸집의 형상오차 분석 (Evaluation of Shape Deviation in Phase Change Material Molds Subjected to Hydration Heat During Ultra-High Performance Concrete Free-form Panel Fabrication)

  • 김홍연;차재혁;윤종영;김성진;이동훈
    • 한국건축시공학회지
    • /
    • 제23권3호
    • /
    • pp.251-260
    • /
    • 2023
  • 비정형 건축물은 외부면이 다양한 곡선이기 때문에 비정형 거푸집은 맞춤제작되어 사용된다. 비정형 거푸집 제작에 있어 재활용이 가능한 Phase Change Material(PCM)과 곡률구현에 용이한 Ultra-High Performance Concrete(UHPC)가 사용된다. 그러나 PCM은 약 58~64℃가 융점이며, UHPC의 수화열로 PCM 거푸집이 손상될 수 있어 실험을 통해 형상을 확인한다. 실험은 제작한 PCM 거푸집에 Silicone sheet 3mm를 설치한 (A)와 설치하지 않은 (B) 거푸집에 UHPC를 타설한다. 실험결과 (A) 3.793mm, (B) 5.72mm가 측정되었으며, (B) 거푸집이 수화열에 취약한 것으로 분석되었다. 이러한 연구는 초고강도 비정형 패널 및 PCM 거푸집 제작 관련 기초자료로 활용될 것으로 기대된다.

기술적(技術的) 효율성(效率性)의 결정요인(決定要因)과 동태적(動態的) 변화(變化) (Technical Efficiency in Korea: Interindustry Determinants and Dynamic Stability)

  • 유승민
    • KDI Journal of Economic Policy
    • /
    • 제12권4호
    • /
    • pp.21-46
    • /
    • 1990
  • 본 논문은 유승민(劉承旻) 이인찬(李仁燦)(1990)이 추정한 우리나라 제조업(製造業)의 기술적(技術的) 효율성(效率性)을 토대로 기술적(技術的) 효율성(效率性)의 산업적(産業的) 격차(隔差)를 설명하는 경험적 증거를 구하고 효율성 추정치의 동태적(動態的) 안정성(安定性)을 분석하였다. 분석결과 산업(産業)의 생산규모(生産規模)가 클수록, 생산특화도(生産特化度)가 높을수록, 자본(資本)-노동비율(勞動比率)의 이질성(異質性)이 낮을수록 높은 기술적(技術的) 효율성(效率性)을 나타내었다. 이러한 결과는 미국(美國) 일본(日本)의 경우에 대한 연구결과와 공통되는 것으로서 기술적(技術的) 효율성(效率性)과 산업조직특성간(産業組織特性間)의 관계가 경제규모나 발전단계의 차이에도 불구하고 가설(假說)의 일반성(一般性)을 지지한다는 점에서 중요한 의미를 지닌다. 기업집중률(企業集中率) 또한 기술적 효율성에 대하여 선형(線型)보다는 이차형(二次型)의 관계를 가지고 있으나 우리나라의 경우 기술적 효율성이 극대화되는 집중률(集中率)은 매우 높은 것으로 나타났다. 또한 본 논문은 효율성(效率性) 척도간(尺度間)의 선택문제에 대한 경험적 기준을 제시하였는데 부가가치액기준(附加價値額基準)보다는 생산액기준(生産額基準)으로 추정된 기술적(技術的) 효율성(效率性)이 제가설(諸假說)들과 잘 부합되는 결과를 나타내었다. 효율성의 동태적(動態的) 안정성(安定性)에 관한 시론적(試論的) 분석(分析)에 의하면 시간변화에 따른 효율성 추청치의 안정성은 효율성 척도간에 다소의 차이는 있으나 기대한 만큼 높지 않았다. 따라서 기술적 효율성의 동태적(動態的) 불안전요인(不安全要因)에 관한 설명은 연구과제로 남는다.

  • PDF