• Title/Summary/Keyword: Curvature Measurement

Search Result 219, Processing Time 0.023 seconds

Recent Development of Automated Strain Measurement System for Sheet Metal Parts (판재 변형률 자동측정시스템의 발전)

  • 김형종
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2000.04a
    • /
    • pp.129-133
    • /
    • 2000
  • It is reasonable to use the stereo vision and image processing technique to digitize 3D coordinates of grid points and to evaluate surface strains on a sheet metal parts. However this method has its intrinsic problems such as the difficulty in enhancement of bad images inevitable error due to digital image resolution of camera and frame grabber unreliability of strains and thickness evaluated from coarse grid on the corner area with large curvature and the limitation of the area that can be measured at a time. Therefore it is still hard to measure strain distribution over the entire surface of a medium,- or large-sized stamped part at a time even by using an automated strain measurement system. In this study the curvature correction algorithm based on the grid refinement and the geometry assembling algorithm based on the global error minimization (GEM) scheme are suggested. Several applications are presented to show the reliability and efficiency of these algorithms.

  • PDF

Effect of combined application of manipulation and stabilization exercises on pain and spinal curvature in patients with chronic back Pain (도수 교정과 안정화 운동 복합적용이 만성 허리통증 환자의 통증과 척추 만곡도에 미치는 영향)

  • Jang, Jae Sun;Kim, Yong Nam
    • Journal of Korean Physical Therapy Science
    • /
    • v.29 no.2
    • /
    • pp.38-47
    • /
    • 2022
  • Background: The purpose of this study was to investigate the effect of the combined application of manipulation and stabilization exercises on pain and spinal curvature in patients with chronic back pain. Design: Randomized controlled trial Methods: The research subjects included 24 women in their 40s and 50s who have chronic back pain. The sample was evenly divided into an experimental group, which received the combined application of manipulation and stabilization exercises, and a control group, which received stabilization exercises only. The 30-minute intervention was applied five times a week for eight weeks. A bivariate repeated measures analysis of variances was conducted to identify the differences between the two groups before the experiment, after the fourth week, and at the end of the eight-week experiment. The level of statistical significance was set at.05. This analysis examined the within-group changes and the between-group changes using a paired t-test and an independent t-test, respectively. Results: Changes in pain differed significantly depending on the time of the measurement, the interaction between the time of the measurement and each group, and between the two groups (p<.05). Changes in the curvature of the bones of the neck, the bones of the back, and the lumbar vertebrae differed significantly depending on the time of the measurement and the interaction between the time of the measurement and each group (p<.05). Conclusion: The combined application of manipulation and stabilization exercises demonstrated a positive effect on changes in pain and spinal curvature, and the method is expected to be a useful intervention for reducing pain and improving spinal curvature in patients with back pain.

The Study on Static Alignment Classification based on the Full Spine AP X-ray of Adults aged 30-39 (30대 성인의 골반, 척추 및 견갑대 정렬의 패턴 분석 - Full Spine AP X-ray 분석에 따른 -)

  • Park, Ji-Hyun;Hong, Seo-Young
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.20 no.2
    • /
    • pp.89-99
    • /
    • 2010
  • Objectives : This study was designed to analyze the pattern of asymmetrical alignment. Methods : This study was carried out with the data from comprehensive medical testing. 91 subjects aged 30-39 were evaluated by full spine AP X-ray. For pelvis, innominate measurement(IM), off centering measurement(OCM), ilium shadow measurement(ISM), major axis of obturator foramen(MaF), minor axis of obturator foramen(MiF) were analyzed. Spinal curvature and height of shoulder girdle were analyzed. Results : 1. In pelvis, It. posterior-inferior and it. inflare combination pattern was 38 cases(42.8%). 2. In spinal curvature, "reverse S" curve was 45 cases(49.4%) and "reverse C" curve was 30 cases(33%). 3. In shoulder girdle, It. superior pattern was 42 cases(46.1 %) and It. superior pattern was 39 cases(42.9%). 4. In whole body analysis, It. posterior-inferior and It. inflare pelvis, "reverse S" spinal curvature and It. superior shoulder girdle combination patten was 11 cases(12.1 %). This pattern is similar to Kendall's right handedness pattern and Zink's common compensatory pattern. Conclusions : Results from this investigation showed asymmetrical alignment in 30-39 years-old adults. This results are expected to contribute to classifying the alignment pattern in clinic and systemic treatment.

Curvature Measurement Using Fiber Bragg Gratings (파이버 브래그 격자를 이용한 곡률 측정)

  • Jung, Jin-Ho;Lee, Jong-Youn
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.9 no.4
    • /
    • pp.1081-1085
    • /
    • 2008
  • To measure the curvature, in this paper, we investigate an optical curvature sensor based on the fiber Bragg gratings. We observed the variation of the Bragg resonant wavelength shift to measure the curvature change. From the experimental results, we knew that the Brags resonant wavelength shift was lineally increased with the increase of the curvature from $0\;m^{-1}$ to $10\;m^{-1}$. It's slope is about $8.8\;pm/m^{-1}$. On the other hand, the spectral reflection decreased with the increase of the curvature.

Development of Automatic Measurement and Inspection System for ALC Block Using Camera (카메라를 이용한 ALC 블록의 치수계측 및 불량검사 자동화 시스템 개발)

  • 허경무;김성훈
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.9 no.6
    • /
    • pp.448-455
    • /
    • 2003
  • A system design technique of automatic thickness measurement and defect inspection system, which measures the thickness of the ALC(Autoclaved Lightweight Concrete) block and inspects the defect on a realtime basis is proposed. The image processing system was established with a CCD camera, an image grabber, and a personal computer without using assembled measurement equipment. The image obtained by this system was analyzed by a devised algorithm, specially designed for the enhanced measurement accuracy. For the realization of the proposed algorithm, the preprocessing method that can be applied to overcome uneven lighting environment, an enhanced edge decision method using 8 edge-pairs with irregular and rough surface, the unit length decision method in uneven condition with rocking objects, and the curvature calibration method of camera using a constructed grid are developed. The experimental results, show that the required measurement accuracy specification is sufficiently satisfied using our proposed method.

Quality Measurement of Deburring Product using Image Processing (화상처리를 이용한 디버링 가공물의 품질 측정)

  • 송무건;백재용;신관수;유송민
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2001.04a
    • /
    • pp.119-124
    • /
    • 2001
  • In this study, a vision system with image processing method have been introduced to find the edge radius of curvature. It was applied to inspect the edge quality of the deburring process product with brush grinding. Size of data was found to be critical in calculating the radius of curvature. Results using laser measurement system were compared.

  • PDF

Viscoplastic collapse of titanium alloy tubes under cyclic bending

  • Lee, Kuo-Long;Pan, Wen-Fung
    • Structural Engineering and Mechanics
    • /
    • v.11 no.3
    • /
    • pp.315-324
    • /
    • 2001
  • This paper presents the experimetal result on the viscoplastic response and collapse of the titanium alloy tubes subjected to cyclic bending. Based on the capacity of the bending machine, three different curvature-rates were used to highlight the viscoplastic behavior of the titanium alloy tubes. The Curvature-controlled experiments were conducted by the curvature-ovalization measurement apparatus which was designed by Pan et al. (1998). It can be observed from experimental data that the higher the applied curvature-rate, the greater is the degree of hardening of titanium alloy tube. However, the higher the applied curvature-rate, the greater is the degree of ovalization of tube cross-section. Furthermore, due to the greater degree of the ovalization of tube cross-section for higher curvature-rates under cyclic bending, the number of cycles to produce buckling is correspondingly reduced. Finally, the theoretical formulation, proposed by Pan and Her (1998), was modified so that it can be used for simulating the relationship between the controlled curvature and the number of cycles to produce buckling for titanium alloy tubes under cyclic bending with different curvature-rates. The theoretical simulation was compared with the experimental test data. Good agreement between the experimental and theoretical results has been achieved.

Development of Aspheric Surface Profilometry using 2nd Derivative (형상의 이차미분을 이용한 비구면 형상측정기술 개발)

  • Kim, Byoung-Chang
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.10 no.2
    • /
    • pp.104-109
    • /
    • 2011
  • I present a method of aspheric surface profile measurement using 2nd derivative of local area profile. This method is based on the principle of curvature sensor which measures the local 2nd derivative under test along a line. The profile is then reconstructed from the data on the each point. Unlike subaperture-stiching method and slope detection method, 2nd derivative method has strong points from a geometric point of view in measuring the aspheric surface profile. The second derivative terms of surface profile is an intrinsic property of the test piece, which is independent of its position and tip-tilt motion. The curvature is measured at every local area with high accuracy and high lateral resolution by using White-light scanning interferometry.

Novel Fiber Optic Microbend Sensor for the Measurement of Cable's Curvature (케이블의 곡률 측정을 위한 새로운 형태의 광섬유 마이크로벤드 센서 개발)

  • Oh, Sang-Woo;Choi, Hyeuk-Jin
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.12 no.4
    • /
    • pp.289-295
    • /
    • 2009
  • In this paper the measurement method of cable's curvature using fiber optic microbend effect and its experimental results are presented. The novel structure of fiber optic microbender, which can generate microbend effect on the optical fiber in the case of both directional bending of cable, was designed. Through the experiment using suggested sensing system, the increasing trend of attenuated optical power was found out under the range from $0.1\;cm^{-1}$ to $0.4\;cm^{-1}$ of curvature. To the multi and distributed measurement, using OTDR, the scattered optical pulses at the bending points are measured and compared with the result which was measured by optical power meter.

  • PDF

Estimation Method of the Best-Approximated Form Factor Using the Profile Measurement of the Aspherical Ophthalmic Lens (단면 형상 측정을 이용한 비구면 안경 렌즈의 최적 근사화된 설계 계수의 추정 방법)

  • Lee Hocheol
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.22 no.5 s.170
    • /
    • pp.55-62
    • /
    • 2005
  • This paper presents mainly a procedure to get the mathematical form of the manufactured aspherical lens. Generally Schulz formula describes the aspherical lens profile. Therefore, the base curvature, conic constant. and high-order polynomial coefficient should be set to get the approximated design equation. To find the best-approximated aspherical form, lens profile is measured by a commercial stylus profiler, which has a sub-micrometer measurement resolution. The optimization tool is based on the minimization of the root mean square of error sum to get the estimated aspherical surface equation from the scanned aspherical profile. Error minimization step uses the Nelder-Mead simplex (direct search) method. The result of the lens refractive power measurement shows the experimental consistency with the curvature distribution of the best-approximated aspherical surface equation