• Title/Summary/Keyword: Currents signal

Search Result 208, Processing Time 0.027 seconds

Deadbeat Control of Active Power Filter using Lossless Resonator (무손실 공진기를 이용한 능동전력필터의 Deadbeat제어)

  • 박지호;노태균;김춘삼;안인모;우정인
    • Proceedings of the KIPE Conference
    • /
    • 1999.07a
    • /
    • pp.350-353
    • /
    • 1999
  • In this paper, a new simple control method for active power filter which can realized the complete compensation of the harmonic currents is proposed. In the proposed scheme, a compensating current reference generator employing lossless resonato implemented by a DSP(Digital Signal Processor) is introduced. Deadbeat control is employed to contro the active power filter. The switching pulse width based SVM(Space Vector Modulation) is adopted so that the current of active power filter is been exactly equal to its reference at the next sampling instant. To compensate the computation delay of digital controller, the prediction of current is achieved by the current observer with deadbeat response.

  • PDF

Multiple current source inverter using tap conversion (탶변환 방식을 이용한 다중 전류원 인버어터에 관한 연구)

  • Yu, Chul-Ro;Han, Woo-Yong;Gu, Deog-Soo;Park, Hyun-Chul
    • Proceedings of the KIEE Conference
    • /
    • 1989.07a
    • /
    • pp.507-509
    • /
    • 1989
  • In multiple current source inverter, generally, transformer connection method and direct connection method in output side have been used. But these methods have faults such as the increment of the number of inverter and the need of the transformer for changing phase in order to get above 12 phase. In this system, we obtained the output currents of 24 phase by adding 2taps in 12 phase inverter. Therefore, this system has such characteristics as the miniaturization of devices and the simplicity of control signal by controlling two inverters and two SCRs for changing taps.

  • PDF

Fault Detection and Diagnosis of Faulty Bearing and Broken Rotor Bar of Induction Motors Based on Dynamic Time Warping (DTW를 이용한 유도전동기 베어링 및 회전자봉 고장진단)

  • Lee, Jae-Hyun;Bae, Hyeon
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.31 no.1
    • /
    • pp.95-102
    • /
    • 2007
  • The issues of preventive and condition-based maintenance, online monitoring, system fault detection, diagnosis and prognosis are of increasing importance. This study introduces a technique to detect and identify faults in induction motors. Stator currents were measured and stored by time domain. The time domain is not suitable for representing current signals, so wavelet transform is used to convert the signals onto frequency domain. The raw signals can not show the significant feature, therefore difference values between the signal of the health conditions and that of the fault conditions are applied. The difference values were transformed by wavelet transform and the features are extracted from the transformed signals. The dynamic time warping method was used to identify the fault type. This study describes the results of detecting fault using wavelet analysis.

Thrust Measurement of Parallel-operated Linear Induction Motors (병렬 운전되는 선형 유도전동기의 추력 계측)

  • Kim, Kyung-Min;Lee, Won-Min;Park, Seung-Chan;Kim, Jeong-Cheol;Park, Yeong-Ho;Kim, Kuk-Jin
    • Proceedings of the KSR Conference
    • /
    • 2007.11a
    • /
    • pp.1599-1604
    • /
    • 2007
  • LIMs propelling the MAGLEV which has been developed in Korea have 3-series and 2-parallel connection, so that 6 LIMs per one vehicle are fed by one inverter. Thrust performance of the parallel-operated LIMs can be different from each other because of variant magnetic air gaps and electrical impedance. The thrust difference between the parallel LIMs cause a twist force on the vehicle. This paper proposes an algorithm to measure thrust of the parallel-operated LIMs. The method uses a digital signal processor(TMS320F2812), voltage and current sensors. As a result, thrust, flux and currents of the parallel-operated small LIMs which are manufactured in our laboratory are monitored by the developed measurement system.

  • PDF

A study on Controlling chaos for Bonhoeffer-van der Pol oscillation model by small parameter perturbation (Bonhoeffer - van der Pol 오실레이터 모델에서의 미소 파라미터 섭동에 의한 카오스 제어)

  • Bae, Youngchul
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.1 no.1
    • /
    • pp.49-55
    • /
    • 2006
  • Applied by periodic Stimulating Currents in Bonhoeffer -Van der Pol(BVP) model, chaotic and periodic phenomena occured at specific conditions. The conditions of the chaotic motion in BVP comprised 0.7182< $A_1$ <0.792 and 1.09< $A_1$ <1.302 proved by the analysis of phase plane, bifurcation diagram, and lyapunov exponent. To control the chaotic motion, two methods were suggested by the first used the amplitude parameter A1, $A1={\varepsilon}((x-x_s)-(y-y_s))$ and the second used the temperature parameterc, $c=c(1+{\eta}cos{\Omega}t)$ which the values of ${\eta},{\Omega}$ varied respectlvly, and $x_s$, $y_s$ are the periodic signal. As a result of simulating these methods, the chaotic phenomena was controlled with the periodic motion of periodisity. The feasibilities of the chaotic and the periodic phenomena were analysed by phase plane Poincare map and lyapunov exponent.

  • PDF

The Analysis and Design of Electro-pneumatic Servo Valve (공기압 Servo Valve 설계 및 해석)

  • Ko, J.H.;Ryu, D.L.;Lee, J.H.;Kim, Y.S.;Kim, D.S.
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.1210-1214
    • /
    • 2008
  • Electro-pneumatic servo valve is an electro-mechanical device which converts electric signal into pneumatic flow rate or pressure. In order to improve the overall performance of pneumatic servo systems, electro-pneumatic servo valves are required, which have fast dynamic characteristic, no air leakage at null, and can be fabricated at a low-cost. The first objective of this research is to design and fabricate a new electro-pneumatic servo valve which satisfies the above-mentioned requirements. In this paper, we has been modeled as a system consisting of coupled electro-mechanic and mechanical subsystems. The appropriateness of the model has been verified by simulation. The simulation model resolves the valve body motion and the solenoid current at high accuracy. Also, we are calculate the displacement of spool and computed results show winding currents, magnetic actuator force, flux density line, displacement, velocity, back EMF, eddy current etc.

  • PDF

A Novel Control of Three-Phase PWM Rectifier Using Single Current Sensor

  • Lee, Woo-Cheol;Kweon, Taeg-Joon;Hyun, Dong-Seok;Lee, Taeck-Kie
    • Proceedings of the KIPE Conference
    • /
    • 1998.10a
    • /
    • pp.374-379
    • /
    • 1998
  • This paper proposes a control method for three-phase PWM rectifier using only single current sensor in DC link. A PWM modulation strategy for reconstructing three phase current from the DC link current is given. The states of the rectifier switch are modified so that all phase currents can be reconstructed in a switching period although one of active vectors is applied only for a short time. Therefore, a novel current control using an adjustment scheme of the modulation signal for a three-phase PWM rectifier will be discussed, and verified with the experimental results.

  • PDF

Digital-Controlled Single-Phase Unified Power Quality Conditioner for Non-linear and Voltage Sensitive Loads

  • Ryoo Hong-Je;Kim Jong-Soo;Kisck Dragos Ovidiu
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.5B no.4
    • /
    • pp.374-381
    • /
    • 2005
  • The ability to provide quality power has become a significant issue in power systems. The main causes of poor power quality are harmonic currents, poor power factor, supply-voltage variations, etc. A technique of achieving both active current distortion compensation, power factor correction and also mitigating the supply-voltage variation (sag or swell) at the load side is presented in this paper. The operation and rating issues of the proposed Single-phase Unified Power Quality Conditioner are also highlighted. To reduce the total cost while simultaneously increasing the performance, the system is fully digitally controlled using the fixed-point TMS320F240 digital signal processor. The performances of the UPQC, which is composed by shunt and series PWM controlled-converters, have been verified on a laboratory prototype.

A Study on the Electromagnetic Compatibility Evaluation of the Electronic Medical Instrumentation (전자의료기기의 전자파 적합성 평가에 관한 연구)

  • Song, C.G.;Kim, J.C.
    • Proceedings of the KIEE Conference
    • /
    • 2002.11c
    • /
    • pp.418-421
    • /
    • 2002
  • The immunity testing in this study was performed to examine the conducted immunity and radiated immunity in medical instrumentation. Experiments were performed to assess the conducted emission and radiated emission of medical instrumentation such as MRI, ultrasound system, and electro surgical unit etc. The emission testing revolves around conducted emissions (high-frequency currents) on power lines and signal cables. Emission testing also looks at the output of energy through the air (called radiated emissions) and analyzes the strength of those radio-frequency signals generated unintentionally by the electrical medical device that is under test. Finally, this study would provide significant data for furture research or electromagnetic interference and compatibility test in medical instrumentation.

  • PDF

Analysis of Radio Environments Allocated to HF Ocean Surface Radar in Korea (고주파(HF) 해양레이더 운용에 분배된 국내 주파수 전파 환경 분석)

  • Song, Kyu-Min
    • Ocean and Polar Research
    • /
    • v.38 no.4
    • /
    • pp.325-330
    • /
    • 2016
  • Partial high frequency bands were allocated to the operation of ocean surface radars that monitor the sea surface currents and waves in WRC-12. On that basis, government-related organizations revised the table of domestic frequency allocation. In order to study radio environments in the allocated bands for ocean radar, tests of the radio signal spectrum were carried at 7-sites using the receiver of the ocean surface radar system operated with a shutdown of the transmitter for 10-60 min. The results showed that no serious radio noises occur at 25 and 43 MHz bands, indicating a good radio environment for the ocean surface radar operation. However, at 13 MHz band, it was difficult to generate stable and confidential data from the ocean surface radar because serious radio noises occurred continuously.