• Title/Summary/Keyword: Current waveform analysis

Search Result 212, Processing Time 0.034 seconds

Leakage Current Waveforms and Spectrum Analysis of EPDM Polymer Insulator according to Environment Condition (환경조건에 따른 EPDM 고분자 애자의 누설전류파형과 스펙트럼 분석)

  • Park, Jae-Jun;Kim, Jeong-Boo;Song, Young-Chul
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.05b
    • /
    • pp.82-86
    • /
    • 2004
  • This research is about the result of leakage current waveform about the situation of surface leakage current and environmental changes(Salt fog, clean fog and rain) by EPDM polymer insulators' amount of salt. The researcher presents the result of changing about fundamental harmonic, 3rd harmonic and 5th harmonic from starting point of supplying power to flashover. In this study, researched environmental affects (clean fog, salt fog and rain) about surface aging of polymer insulators and used frequency spectrum of leakage current waveform to develop the diagnostic technique of surface aging. When amount of salt contents changed, surface aging stage and the degree of aging (distortion factor) about 3rd and 5th harmonic waveform on low frequency harmonic wave. The distortion factor which is harmonic percentage about basic harmonic is important pointer to evaluate the surface condition of polymer insulators.

  • PDF

A Method of Plotting Component A Scaled Waveform for Aircraft Lightning Test (항공기 낙뢰 시험을 위한 Component A 축소 파형 도식화 방법)

  • Jo, Jae-Hyeon;Kim, Yun-Gon;Kim, Dong-Hyeon;Lee, Hak-Jin;Myong, Rho-Shin
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.49 no.9
    • /
    • pp.801-811
    • /
    • 2021
  • Lightning can deliver large amounts of energy to the aircraft in a short period of time, resulting in catastrophic consequence. In particular, lightning strikes accompanied by high temperature heat and current can damage aircraft surface and internal electronic equipment, seriously affecting flight safety. Lightning experiments to analyze this effect use a Component A waveform with a maximum current of 200 kA as specified in SAE ARP 5412B. However, the actual lightning occurs mostly below 35kA and lightning indirect tests are conducted by reducing waveforms to prevent damage to internal electronic equipment. In this study, we examine previous methods to plot the Component A reduced waveform and identify their limitations. We then propose a new method to plot the reduced waveform based on adjusting the correction factor of the aircraft lightning Component A waveform. Finally, the electromagnetic analysis software EMA3D was used to compare the internal induced current size reduction ratio of the internal cable harness of the EC-155B helicopter.

Fault state detection and remaining useful life prediction in AC powered solenoid operated valves based on traditional machine learning and deep neural networks

  • Utah, M.N.;Jung, J.C.
    • Nuclear Engineering and Technology
    • /
    • v.52 no.9
    • /
    • pp.1998-2008
    • /
    • 2020
  • Solenoid operated valves (SOV) play important roles in industrial process to control the flow of fluids. Solenoid valves can be found in so many industries as well as the nuclear plant. The ability to be able to detect the presence of faults and predicting the remaining useful life (RUL) of the SOV is important in maintenance planning and also prevent unexpected interruptions in the flow of process fluids. This paper proposes a fault diagnosis method for the alternating current (AC) powered SOV. Previous research work have been focused on direct current (DC) powered SOV where the current waveform or vibrations are monitored. There are many features hidden in the AC waveform that require further signal analysis. The analysis of the AC powered SOV waveform was done in the time and frequency domain. A total of sixteen features were obtained and these were used to classify the different operating modes of the SOV by applying a machine learning technique for classification. Also, a deep neural network (DNN) was developed for the prediction of RUL based on the failure modes of the SOV. The results of this paper can be used to improve on the condition based monitoring of the SOV.

An Experimental Study on the Analysis of the Interventricular Pressure Waveform in the Moving-Actuator type Total Artificial Heart (이동작동기식 완전 이식형 인공 심장의 심실간 공간 압력 파형 해석에 관한 실험적 연구)

  • 조영호;최원우
    • Journal of Biomedical Engineering Research
    • /
    • v.18 no.1
    • /
    • pp.25-36
    • /
    • 1997
  • To regulate cardiac output of the Total Artificial Heart(TAH) physiologically, the hemodynamic information must be toed back to the controller. So far, our group has developed an automatic cardiac output control algorithm using the motor current waveform, It is, however difficult to detect the preload level such as a filling status of ventricular inflow and the variation of atrial pressures within normal physiologic range(0-15 mmHg) by analyzing the motor current which simultaneously reflects the afterload effect. On the other hin4 the interventricular volume pressure(IVP) which is not influenced by arterload but by preload is a good information source for the estimation of preload states. In order to find the relationship between preload and IVP waveform, we set up the artificial heart system on the Donovan type mock circulatory system and measured the IVP waveform, right and left atrial pressures, inflow and outflow waveforms and the signals represented the information of moving actuator's position. We shows the feasibility of estimating the hemodynamic changes of inflow by using IVP waveform. fife found that the negative peak value of IVP waveform is linearly related to atrial pressures. And we also found that we could use the time to reach the negative peak in IVP waveform, the time to open outflow valve, the area enclosed IVP waveform as unfu parameters to estimate blood filling volume of diastole ventricle. The suggested method has advantages of avoiding thrombogenesis, bacterial niche formation and increasing longterm reliability of sensor by avoiding direct contact to blood.

  • PDF

A Study on Waveform Analysis of Input Current for Novel Boost AC-DC Converter of High Power Factor (새로운 고역률 승압형 AC-DC 컨버터의 입력전류 파형분석에 관한 연구)

  • Kwak, Dong-Kurl
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.8
    • /
    • pp.102-108
    • /
    • 2005
  • In this paper, authors propose novel boost AC-DC converter of high power factor and analyze for waveform and harmonics component of input current. The input current waveform in the proposed converter is got to be a sinusoidal form of discontinuous pulse in proportion to magnitude of at input voltage under the constant duty cycle switching. Therefore, input power factor is nearly unity. Particularly, the stored energy of loss-less snubber capacitor is recovered with input side and increases input current from resonant operation. The result is that input power factor of the proposed converter is higher than that of conventional converter of high power factor. Some simulative results on computer and experimental results are included to confirm the validity of the analytical results.

Analysis of input current in a Boost AC-DC converter using the partial resonant method (부분공진 승압형 AC-DC 컨버터의 입력전류 해석)

  • Kwak, Dong-Kurl;Lee, Kyung-Chin;Park, Jum-Mun;Lee, Jin-Ho;Kim, Young-Mun;Lee, Hyun-Woo
    • Proceedings of the KIEE Conference
    • /
    • 1995.07a
    • /
    • pp.185-187
    • /
    • 1995
  • A boost converter proposed in this paper operates with high power factor due to input current of sinusoidal waveform. If there were no input LPF, the current is got to be discontinuos form in proportion to AC input voltage magnitude under the constant duty factor switching. Thereupon, the harmonics of input current waveform is reduced and the LPF is made with few elaboration and the control circuit is simple. The switching devices in proposed circuit are operated with soft switching by the partial resonant method. The patial resonant circuit makes use of a reactor using step-up and a capacitor of loss-less snubber. The result is that switching loss is very low and efficiency of system is high.

  • PDF

Characteristic Analysis of Power Compensation Condenser Considering Voltage Harmonics (전압 고조파를 고려한 역률보상용 콘덴서의 특성 분석)

  • Kim, Jong-Gyeum;Lee, Dong-Ju
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.59 no.2
    • /
    • pp.141-145
    • /
    • 2010
  • Most of the industrial loads includes the non-linear load as well as the linear load because there are many kinds of power conversion equipments at the input stage of the load in distribution network. The non-linear load causes the distortion of voltage waveform at PCC because the non-linear load generates the harmonic current. As a result, various voltage harmonics are existed at PCC depending on the current harmonics from the non-linear load. And, a series reactor is generally connected to the power capacitor in series to attenuate the distortion of voltage waveform and to reduce an inrush current of power capacitor. Also, harmonic current of power capacitor is highly dependent on the series reactor because it is operated with the power capacitor as a passive filter against nonlinear loads. Then, these capacitors might be damaged by the excessive voltage and current harmonic components. In this paper, we presented how to select the capacitor and series reactor to meet the requirement of the voltage distortion at PCC and analyzed the voltage, current and capacity rating of the power capacitor by the computer simulation to ensure the safe operation of power capacitor when the voltage harmonics at PCC are existed. Also, the analysis data were compared with the experimental measurements for the verification.

Copper Oxide Growing Characteristics of PVC Insulated Wire and Application to the Fire Investigation (비닐절연전선의 산화물 성장 특성과 화재조사에의 적용)

  • Kim, Hyang-Kon;Choi, Chung-Seog;Kim, Dong-Ook;Choi, Hyo-Sang
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.56 no.1
    • /
    • pp.37-44
    • /
    • 2007
  • This paper describes characteristics for copper oxide growth of polyvinyl chloride(PVC) insulated wires by series arc. In this experiment, 600V IV wires were used, and characteristics of oxide growth and ignition process were analyzed in case load was 300W, 460W and 600W, respectively. In the result of experiment, covering materials were molten, carbonized and ignited, whereas, oxidized materials were grown in conducting material. During copper oxide was growing, contact voltages and power dissipations increased. When there is copper oxide growth, the waveform of current showed sinusoidal waveform, and the waveform of voltage showed modified waveform. Oxidized materials were heated at about $905^{\circ}C$, surface structure showed irregular shapes, and cross-section showed multiple cracks. And, the results of this experiment were applied to the fire cause analysis of fire evidence collected at the fire scene.

Characteristics Analysis of Outer Rotor Type BLDC Motor according to Input Voltage Waveform (외전형 BLDC 전동기의 입력전압 파형에 따른 특성해석)

  • Kim Kyung Ho;Choi Geo Seung;Kim Myoung Su;Cho Yun Hyun
    • Proceedings of the KIPE Conference
    • /
    • 2001.07a
    • /
    • pp.22-24
    • /
    • 2001
  • This paper presents the characteristics of current harmonics and torque ripple of Brushless DC motor, which is developed the fan blower of vehicles, according to input voltage waveform. To investigate the torque ripple and the phase current harmonics, these characteristics is analysed and compared the experimental results. In the process of analysis, FEM is introduced and computed a transient state torque of BLDC with a sinusoidal and a PWM wave voltage.

  • PDF

Sinusoidal Input Power factor Improved for Single-Phase Buck AC-DC Type Converter (정현파 입력 역률개선을 위한 단상 강압형 AC-DC 컨버터)

  • Jung, S.H.;Kwon, K.S.;Lee, H.W.
    • Proceedings of the KIEE Conference
    • /
    • 2001.11c
    • /
    • pp.338-340
    • /
    • 2001
  • Power factor improved for single-phase buck-converter is studied in the paper. To sinusoidal waveform the input current with a near-unity power factor over a wide variety of operating conditions, the output capacitor is operated with voltage reversibility for the supply by arranging the auxiliary diode and power switching device. Then the output voltage is superposed on the input voltage during on time duration of power switching devices in order to minimize the input current distortion caused by the small input voltage when changing the polarity. The tested setup, using two insulated gate bipolar transistors(IGBT) and a microcomputer, is implemented and IGBT are switched with 20[kHz], which is out of the audible band. Moreover, a rigorous state-space analysis is introduced to predict the operation of the rectifier. The simulated results confirm that the input current can be sinusoidal waveform with a near-unity power factor and a satisfactory output voltage regulation can be achieved.

  • PDF