• 제목/요약/키워드: Current variation

검색결과 2,714건 처리시간 0.029초

계통 연계형 PCS의 운전모드 전환시 사고전류 최소화를 고려한 LCL 필터 설계 (LCL Filter Design with the consideration of Fault Current Minimization in Mode Transfer of a Grid Connected Type PCS)

  • 정재헌;권창근;노의철;김인동;김흥근;전태원
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2011년도 전력전자학술대회
    • /
    • pp.48-49
    • /
    • 2011
  • A new LCL filter design of a PCS with the consideration of fault current minimization is proposed. The magnitude of fault current is analysed with the variation of inverter side $L_i$, line side $L_u$, and filter capacitor $C_f$ under constant line side $THD_i$ of 5%. It is found that inverter side fault current reaches up to 200%~660% of the rated current with the variation of $L_i$. It is expected that the results can be applied to the detailed design of PCS filter.

  • PDF

복굴절이 큰 광섬유에 제작된 장주기 광섬유 격자를 이용한 광섬유 전류 센서 (Fiber-optic Ccurrent Sensor Using a Long-period Fiber Grating Inscribed on a High Birefringent Fiber)

  • 이용욱
    • 전기학회논문지
    • /
    • 제56권10호
    • /
    • pp.1823-1825
    • /
    • 2007
  • Based on Faraday effect, the variation of current flowing through the conductor can be encoded as that of azimuth angle of light polarization propagating through the fiber coil wound onto the conductor. The amount of current can be obtained by measuring the variation of the light intensity transformed from that of the azimuth angle through a polarization analyzer. In this paper we propose a fiber-optic current sensor system that employs a fiber polarization analyzer as a sensor interrogation device. The fiber polarization analyzer was prepared by inscribing a long-period fiber grating on a high birefringent fiber. At the fixed wavelength of 1522.5 nm, the fabricated fiber device has the polarization extinction ratio of more than 25 dB. The measurement of large current up to 600 Arms was accomplished based on a simple fiber interrogation device and the measurement output of the sensor system showed a good linearity.

WC 분말 크기에 따른 Ni-WC 복합 도금층의 특성 거동에 관한 연구 (Electrodeposition Behavior of Ni-WC Composite Coatings with Variation of WC Particle Size)

  • 김대근;이재호
    • 한국표면공학회지
    • /
    • 제39권3호
    • /
    • pp.115-120
    • /
    • 2006
  • The codeposition behavior of WC particles from an additive-free nickel sulfate and sulfamate solution has been investigated. Electroplating of Ni/WC composites was carried out at different current density with variation of WC particle size. The Guglielmi adsorption mechanism is applied to the electroplating of the fine WC in Ni matrix. The contents of WC in Ni composite coating were increased both by increasing current density and WC concentration in the bath. The hardness of Ni/WC composite coating at low current density is higher than that at high current density since finer WC particles dispersed through the coating. The codeposition behaviors of Co coated WC particles were also investigated. Conducting layer of particles promoted the codeposition behavior of Ni/WC-Co composite coatings.

Acoustic Variation Conditioned by Prosody in English Motherese

  • Choi, Han-Sook
    • 말소리와 음성과학
    • /
    • 제2권1호
    • /
    • pp.41-50
    • /
    • 2010
  • The current study exploresacoustic variation induced by prosodic contexts in different speech styles,with a focus on motherese or child-directed speech (CDS). The patterns of variation in the acoustic expression of voicing contrast in English stops, and the role of prosodic factors in governing such variation are investigated in CDS. Prosody-induced acoustic strengthening reported from adult-directed speech (ADS)is examined in the speech data directed to infants at the one-word stage. The target consonants are collected from Utterance-initial and -medial positions, with or without focal accent. Overall, CDS shows that the prosodic prominence of constituents under focal accent conditions variesin the acoustic correlates of the stop laryngeal contrasts. The initial position is not found with enhanced acoustic values in the current study, which is similar to the finding from ADS (Choi, 2006 Cole et al, 2007). Individualized statistical results, however, indicate that the effect of accent on acoustic measures is not very robust, compared to the effect of accent in ADS. Enhanced distinctiveness under focal accent is observed from the limited subjects' acoustic measures in CDS. The results indicate dissimilar strategies to mark prosodic structures in different speech styles as well as the consistent prosodic effect across speech styles. The stylistic variation is discussed in relation to the listener under linguistic development in CDS.

  • PDF

Industry 4.0 - A challenge for variation simulation tools for mechanical assemblies

  • Boorla, Srinivasa M.;Bjarklev, Kristian;Eifler, Tobias;Howard, Thomas J.;McMahon, Christopher A.
    • Advances in Computational Design
    • /
    • 제4권1호
    • /
    • pp.43-52
    • /
    • 2019
  • Variation Analysis (VA) is used to simulate final product variation, taking into consideration part manufacturing and assembly variations. In VA, all the manufacturing and assembly processes are defined at the product design stage. Process Capability Data Bases (PCDB) provide information about measured variation from previous products and processes and allow the designer to apply this to the new product. A new challenge to this traditional approach is posed by the Industry 4.0 (I4.0) revolution, where Smart Manufacturing (SM) is applied. The manufacturing intelligence and adaptability characteristics of SM make present PCDBs obsolete. Current tolerance analysis methods, which are made for discrete assembly products, are also challenged. This paper discusses the differences expected in future factories relevant to VA, and the approaches required to meet this challenge. Current processes are mapped using I4.0 philosophy and gaps are analysed for potential approaches for tolerance analysis tools. Matching points of simulation capability and I4.0 intents are identified as opportunities. Applying conditional variations, incorporating levels of adjustability, and the un-suitability of present Monte Carlo simulation due to changed mass production characteristics, are considered as major challenges. Opportunities including predicting residual stresses in the final product and linking them to product deterioration, calculating non-dimensional performances and extending simulations for process manufactured products, such as drugs, food products etc. are additional winning aspects for next generation VA tools.

Impact of Upper Limb Joint Fluid Variation on Inflammatory Diseases Diagnosis

  • Hari, Krishnan G.;Ananda, Natarajan R.;Nanda, Anima
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권6호
    • /
    • pp.2114-2117
    • /
    • 2014
  • Joint pain is generally a common disorder not only for the old aged people but also for the immunocompromised patients. The present proposed study reveals the presence of inflammatory diseases in joint generally diagnosed by removing synovial fluid and changes in the volume and composition are examined for the presence of WBC and crystals. This study implement a non-invasive approach to identify the changes in joint fluid by measuring the changes in electrical property of the synovial tissue under the influence of electrical current signal with frequency range between 100 kHz to 300 kHz. The response of tissue for the current signal was measured in terms of potential drop across the tissue. The hardware system design consists of input and output sections. The input section which applies current signal to upper limb joint region is made of ICL8038 function generator IC with amplifier and voltage to current converter. The output section picks voltage variation using metal surface electrode, amplifier, ADC, PIC microcontroller and LCD interface. 100 patient inclusive of normal and disease affected patients where examined for upper limb synovial fluid variation and inflammatory diseases were identified.

소규모 오수처리를 위한 전기화학적 방법에 의한 대장균 소독에 관한 연구 (A Study on Escherichia Coli Disinfection by the Electrochemical Method for Small Sewerage System)

  • 박영식;정노성;김동석
    • 한국환경과학회지
    • /
    • 제16권4호
    • /
    • pp.441-447
    • /
    • 2007
  • This study was carried out to investigate the effect of electrochemical (EC) disinfection of artificial wastewater contaminated by Escherichia coli culture. Circulated batch type electrochemical disinfection system using three plates electrodes was used. Also, the several factors (pH, ORP, DO, temperature, current, conductivity) were measured in order to investigate the fundamental design factor in the EC disinfection system. It was demonstrated that the EC process was highly effective for wastewater disinfection. At the constant voltage, the disinfection efficiency was increased according to time. The disinfection efficiency and current increased as the increase of voltage. The variation of conductivity was a little related to the variation of CFU (colony forming units). The differences in disinfection efficiency according to the ice pack and the variation of electrodes were not occurred. The EC disinfection efficiency and current increased according to the increase of circulating flow rate.

온도변화에 따른 LDMOS의 전류변동 억제에 관한 연구 (A Study of Suppression Current for LDMOS under Variation of Temperature)

  • 전중성
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제30권8호
    • /
    • pp.901-906
    • /
    • 2006
  • In this paper, the power amplifier using active bias circuits for LDMOS(Lateral Diffused Metal Oxide Semiconductor) MRF-21180 is designed and fabricated. According to change the temperature, the gate voltage of LDMOS is controlled by the fabricated active bias circuits which is made of PNP transistor to suppress drain current. The driving amplifier using MRF-21125 and MRF-21060 is made to drive the LDMOS MRF-21180 power amplifier. The variation of current consumption in the fabricated 60 watt power amplifier has an excellent characteristics of less than 0.1 A, whereas a passive biasing circuit dissipates more than 0.5 A. The implemented power amplifier has the gain over 9 dB, the gain flatness of less than $\pm$0.1 dB and input and output return loss of less than -6 dB over the frequency range 2.11 $\sim$ 2.17 GHz. The DC operation point of this power amplifier at temperature variation 0 $^{\circ}C$ to 60 $^{\circ}C$ is fixed by active bias circuit.

UPS inverter의 2차 데드비트 응답을 위한 반복부하예측기법 (Repetitive Load Prediction for Second Order Deadbeat Response Applied to UPS Inverter)

  • 최재호
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2000년도 전력전자학술대회 논문집
    • /
    • pp.339-342
    • /
    • 2000
  • Repetitive Load Prediction is proposed for the UPS inverter application of the second order deadbeat controller which is robust against the calculation time delay and the parameter variation and which gets fast response against the load variation. The proposed technique predicts the load current ahead of two sampling time using that the load current is periodic. This is effective under nonlinear load condition. The proposed technique is derived theoretically and verified through simulation and experimental result.

  • PDF

선형 전동기의 상전류 조정을 통한 토크리플 저감법 (Current Variation Method for Reducing Torque Ripples of Linear Motor)

  • 김민재;임재원;정현교
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 춘계학술대회 논문집 에너지변화시스템부문
    • /
    • pp.85-87
    • /
    • 2009
  • Linear motor is an energy conversion device which makes kinetic energy from electrical energy. This paper presents a method to reduce torque ripples by variation of the current. The torque ripples are basically caused by detent force so this method has a focus on reducing detent force. The torque ripples were calculated by finite element method.

  • PDF