• Title/Summary/Keyword: Current transient

Search Result 1,275, Processing Time 0.031 seconds

A Study on the Development of a Transient Voltage Blocking Device for Info-communication Facilities (정보통신기기용 과도전압 차단장치의 개발에 관한 연구)

  • 한주순
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.23 no.2
    • /
    • pp.159-167
    • /
    • 1999
  • This paper presents a new transient voltage blocking device(TOBD)which low power and high frequency bandwidth to protect info-communication facilities from transient voltages. Conventional protection devices have some problems such as low frequency bandwidth low ener-gy capacity and high remnant voltage. in order to improve these limitations a hybrid type TOBD which consists of a gas tube avalanche diodes and junction type field effect transistor (JFETs) is developed. The TOBD differs from the conventional protection devices in configuration and JFETs are used as an active non-linear element and a high speed switching diode with low capacitance limited high current. Therefore the avalanche diode with low energy capacity are protected from the high current and the TOBD has a very small input capacitance. From the performance test using combination surge generator which can produce $1.2/50{\mu}m$ 4.2 kV/max, $8/20{\mu}m$ 2.1 kAmax it is confirmed that the proposed TOBD has an excellent protection per-formance in tight clamping voltage and limiting current characteristics.

  • PDF

Study of requirements for protective current transformers for transient performance (보호용 변류기의 과도성능에 대한 고찰)

  • Jung Heung-Soo;La Dae-Ryeol;Kim Sun-Koo;Roh Chang-il;Kim Won-Man;Lee Dong-Jun
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.839-841
    • /
    • 2004
  • IEC 60044-6 (Requirements for protective current transformers for transient performance) was established to Korea Standard (KS C IEC 60044-6 ; Instrument transformers Part 6 ; Requirements for protective current transformers for transient performance) in December 11, 2003. In this paper, requirements, test items and test methods protective current transformers for transient performance.

  • PDF

LDO Regulator with Improved Transient Response Characteristics and Load Transient Detection Structure (Load Transient Detection 구조 및 개선된 과도응답 특성을 갖는 LDO regulator)

  • Park, Tae-Ryong
    • Journal of IKEEE
    • /
    • v.26 no.1
    • /
    • pp.124-128
    • /
    • 2022
  • Conventional LDO regulator external capacitors can reduce transient response characteristics such as overshoot and undershoot. However, the capacitorless LDO regulator proposed in this study applied body technology to the pass transistor to improve the transient response and provide excellent current drive capability. The operating conditions of the proposed LDO regulator are set to an input voltage that varies from 3.3V to 4.5V, a maximum load current of 200mA, and an output voltage of 3V. As a result of the measurement, it was found that when the load current was 100 mA, the voltage was 95 mV in the undershoot state and 105 mV in the overshoot state.

Transient Characteristics by Transformer %Impedance at the time of Opening the Main Circuit Breaker on the Electric Railway Vehicle (전기철도차량 주변압기의 %임피던스에 따른 차단기 개폐시 과도특성 분석)

  • Chang, Sang-Hoon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.5
    • /
    • pp.719-725
    • /
    • 2014
  • Transient of Electric railway vehicle occurs when change to another state. The duration of the transient phenomenon only takes a few second. During this time is considered, the present of short circuit current and the normal state, the energy is present in the form of a magnetic field. Recognized by the vibration of the transient voltage or transient current at witch energy is present in the field. This paper is presented the result of transient characteristics by transformer % impedance at the time of opening and closing of the main circuit Breaker on the electric railway vehicle.

Improvement of One-Cycle Controller Response with a Current Mode Controller

  • Ruzbehani, Mohsen;Zhou, Luowei;Mirzaei, Nasser
    • Journal of Power Electronics
    • /
    • v.10 no.1
    • /
    • pp.21-26
    • /
    • 2010
  • The most important feature of the one-cycle control method is its excellent ability in line disturbance rejection. However, when it is used as a controller in dc-dc converters, it has an undesirable transient response. The voltage overshoot at the transient time, which usually exists in one-cycle controlled converters, is unwanted in many applications and it is sometimes hazardous. In this paper, it is shown that the combination of a one-cycle controller with a current mode controller, can improve the transient response and consequently the overshoot can be controlled. Therefore, the combined controller has the excellent line disturbance rejection of a one-cycle controller and the output current limiting capability of current mode controllers. Because in this scheme a one-cycle controller is the master controller, the problem of instability of current mode control, will not happen. By simulation and a practical prototype, the capability of the method is shown.

Enhancement of Power System Transient Stability and Power Quality Using a Novel Solid-state Fault Current Limiter

  • Fereidouni, A.R.;Vahidi, B.;Mehr, T. Hoseini;Doiran, M. Garmroodi
    • Journal of Electrical Engineering and Technology
    • /
    • v.6 no.4
    • /
    • pp.474-483
    • /
    • 2011
  • Solid-state fault current limiters (SSFCL) in power systems are alternative devices to limit prospective short circuit currents from reaching lower levels. Fault current limiters (FCL) can be classified into two categories: R-type (resistive) FCLs and L-type (inductive) FCLs. L-type FCL uses an inductor to limit fault level and is more efficient in suppressing voltage drop during a fault. In contrast, R-type FCL is constructed with a resistance and is more effective in consuming the acceleration energy of generators during a fault. Both functions enhance the transient stability of the power system. In the present paper, a novel SSFCL is proposed to enhance power system transient stability and power quality. The proposed SSFCL uses both functions of an L-type and R-type FCL. SSFCL consists of four diodes, one self-turn-off IGCT, a current-limiting by-pass inductor (L), and a variable resistance parallel with an inductor for improvement of power system stability and prevention of over-voltage across SSFCL. The main advantages of the proposed SSFCL are the simplicity of its structure and control, low steady-state impedance, fast response, and the existence of R-type and Ltype impedances during the fault, all of which improve power system stability and power quality. Simulations are accomplished in PSCAD/EMTDC.

Zero-Transient Current Control Method for PWM Dimming of LED (LED의 펄스폭 변조를 통한 휘도조절시 과도구간이 존재하지 않는 전류 제어 기법)

  • Yoon, Young-Nam;Lee, Sang-Hyun;Cho, Sang-Ho;Hong, Sung-Soo;Kim, Chang-Sub;Lee, Hyo-Bum;Han, Sang-Kyoo
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.16 no.1
    • /
    • pp.64-70
    • /
    • 2011
  • This paper presents a zero-transient current control method for PWM dimming of LED. Since the proposed LED current control method has no transient state, it features a high resolution, high linearity, and no current overshoot through LED along a wide dimming range. The operational principles of the proposed LED current control circuit are presented. To confirm the validity of the proposed method experimental results from a prototype circuit of the 46-inch LCD TV are given.

Minimum Time Current Control in 3-Phase Balanced Systems (3상 대칭 시스템의 최단시간 전류제어)

  • Choe, Jong-U;Seol, Seung-Gi
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.51 no.6
    • /
    • pp.313-320
    • /
    • 2002
  • In this paper, a new current controller with fast transient response is Proposed. The basic concept is to find the optimal control voltage for tracking the reference current with minimum time under the voltage limit constraint. The generalized solution of the minimum time current control in the systems are presented in this paper. With the generalized solution, the minimum time current controller can be easily applied to all the 3-phase balanced system. Through the simulation and the experiment, it is observed that the proposed controller has much less transient time than the conventional synchronous PI regulator.

R-type HTS-FCL Model considering transient characteristics

  • Yoon Jae Young;Lee Seung Ryul;Kim Jong Yul
    • Progress in Superconductivity and Cryogenics
    • /
    • v.7 no.2
    • /
    • pp.35-38
    • /
    • 2005
  • One of the most serious problems in KEPCO system operation is higher fault current than the SCC(Short Circuit Capacity) of circuit breaker. There are many alternatives to reduce the increased fault current such as isolations of bus ties, enhancement of SCC of circuit breaker, applications of HVDC-BTB(Back to Back) and FCL(fault current limiter). But, these alternatives have some drawbacks in viewpoints of system stability and cost. As the superconductivity technology has been developed, the resistance type HTS-FCL(High Temperature Superconductor Fault Current Limiter) can be one of the most attractive alternatives to solve the fault current problem. To evaluate the accurate transient performance of resistance type HTS-FCL, it is needed that the dynamic simulation model considering transient characteristics during quenching and recovery state. Under this background, this paper presents the EMTDC model for resistance type HTS-FCL considering the nonlinear characteristic of final resistance value when quenching and recovery phenomena by fault current injection and clearing occurs.

Two Types of Voltage-activated Calcium Currents in Goldfish Horizontal Cells

  • Paik, Sun-Sook;Bai, Sun-Ho;Jung, Chang-Sub
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.9 no.5
    • /
    • pp.269-273
    • /
    • 2005
  • In horizontal cells (HCs) that were freshly dissociated from goldfish retina, two types of voltagedependent calcium currents ($I_{Ca}$) were recorded using a patch-clamping configuration: a transient type current and a sustained type current. The cell was held at -40 mV, and the prepulse step of -90 mV was applied before command pulse between -65 and +55 mV. The transient $Ca^{2+}$ current was activated by depolarization to around -50 mV from a prepulse voltage of -90 mV lasting at least 400 ms and reached a maximal value near -25 mV. On the other hand, the sustained $Ca^{2+}$ current was induced by pre-inactivation for less than 10 ms duration. Its activation started near -10 mV and peaked at +20 mV. $Co^{2+}$ (2 mM) suppressed both of these two components, but nifedipine ($20{\mu}M$), L-type $Ca^{2+}$ channel antagonist, blocked only the sustained current. Based on the activation voltage and the pharmacolog$I_{Ca}$l specificity, the sustained current appears to be similar to L-type $I_{Ca}$ and the transient type to T-type $I_{Ca}$. This study is the first to confirm that transient type $I_{Ca}$ together with the sustained one is present in HCs dissociated from goldfish retina.