• 제목/요약/키워드: Current transient

검색결과 1,275건 처리시간 0.039초

Transient Performance Improvement in the Boundary Control of Boost Converters using Synthetic Optimized Trajectory

  • Feng, Gaohui;Yuan, Liqiang;Zhao, Zhengming;Ge, Junjie;Ye, Xiuxi;Lu, Ting
    • Journal of Power Electronics
    • /
    • 제16권2호
    • /
    • pp.584-597
    • /
    • 2016
  • This paper focuses on an improvement in the transient performance of Boost converters when the load changes abruptly. This is achieved on the basis of the nature trajectory in Boost converters. Three key aspects of the transient performance are analyzed including the storage energy change law in the inductors and capacitors of converters during the transient process, the ideal minimum voltage deviation in the transient process, and the minimum voltage deviation control trajectory. The changing relationship curve between the voltage deviation and the recovery time is depicted through analysis and simulations when the load suddenly increases. In addition, the relationship curve between the current fluctuation and the recovery time is obtained when the load suddenly decreases. Considering the aspects of an increasing and decreasing load, this paper proposes the transient performance synthetic optimized trajectory and control laws. Through simulation and experimental results, the transient performances are compared with the other typical three control methods, and the ability of proposed synthetic trajectory and control law to achieve optimal transient performance is verified.

Transient-Performance-Oriented Discrete-Time Design of Resonant Controller for Three-Phase Grid-Connected Converters

  • Song, Zhanfeng;Yu, Yun;Wang, Yaqi;Ma, Xiaohui
    • Journal of Power Electronics
    • /
    • 제19권4호
    • /
    • pp.1000-1010
    • /
    • 2019
  • The use of internal-model-based linear controller, such as resonant controller, is a well-established technique for the current control of grid-connected systems. Attractive properties for resonant controllers include their two-sequence tracking ability, the simple control structure, and the reduced computational burden. However, in the case of continuous-designed resonant controller, the transient performance is inevitably degraded at a low switching frequency. Moreover, available design methods for resonant controller is not able to realize the direct design of transient performances, and the anticipated transient performance is mainly achieved through trial and error. To address these problems, the zero-order-hold (ZOH) characteristic and inherent time delay in digital control systems are considered comprehensively in the design, and a corresponding hold-equivalent discrete model of the grid-connected converter is then established. The relationship between the placement of closed-loop poles and the corresponding transient performance is comprehensively investigated to realize the direct mapping relationship between the control gain and the transient response time. For the benefit of automatic tuning and real-time adaption, analytical expressions for controller gains are derived in detail using the required transient response time and system parameters. Simulation and experimental results demonstrate the validity of the proposed method.

GaN증폭기의 본드 와이어 용융단선 현상분석과 과도전류를 고려한 전류용량 선정에 대한 연구 (A Study on Bond Wire Fusing Analysis of GaN Amplifier and Selection of Current Capacity Considering Transient Current)

  • 유우성;석연수;황규혁;김기준
    • 전기전자학회논문지
    • /
    • 제26권4호
    • /
    • pp.537-544
    • /
    • 2022
  • 본 논문은 최근 전자전, 레이더, 기지국 및 위성통신분야에서 각광받고 있는 GaN HEMT(Gallium Nitride High Electron Mobility Transistor) die를 이용한 고출력증폭기의 제작에 사용되는 본드 와이어의 용융단선 현상과 원인을 분석하였다. 고출력증폭기의 주요 성능인 최대 출력전력을 얻기 위해서는 최적의 임피던스 정합이 필요하고 정격전류뿐만 아니라 과도전류에 대한 발열을 고려하여 본드 와이어 소재에 부합하는 직경과 가닥수가 정해져야 한다. 특히, GaN과 같이 에너지 밴드 갭이 넓은 화합물반도체는 설계효율이 낮거나 방열이 부족하면 열 저항 증가로 인해 본드 와이어의 용융단선을 촉발하는 현상을 확인하였다. 본 자료는 발열조건에 대한 모의시험을 수행하고, IR현미경 측정을 통한 검증으로 GaN소자를 이용한 응용분야에 참고자료로 활용이 기대된다.

HVDC 단에 연결된 동기기의 여자시스템 스트레스 (Excitation System Stress in Synchronous Machine Connected to HVDC System)

  • 김찬기
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제51권8호
    • /
    • pp.482-492
    • /
    • 2002
  • This paper deals with overvoltage stresses in the field circuit of synchronous machine connected to HVDC terminal. A load rejection of the HVDC may cause generator in the station to become self-excited, resulting in a severe system overvoltage. This paper shows that violent field current oscillations can be produced by resonance between the machine inductance and the terminal capacitance. As most conventional excitation system do not allow reverses current, new topology of excitation system to allow reverse current is proposed. the proposed system can limit the rate of rise of terminal voltage during conditions of self excitation. Apart from these simulations, the nature(Magnitude and frequency) of the field transient state is explained mathematically. Finally, the EMTDC program is used for the simulation studies.

전류 주입형 방식의 UPFC 모델을 이용한 과도 안정도 해석 (Modeling of Unified Power Flow Controllers Using a Current Injection Method for Transient Stability Analysis)

  • 김천회;박정수;장길수;손광명;김태균
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 A
    • /
    • pp.332-334
    • /
    • 2005
  • This paper presents a dynamic simulation of the unified power flow controller (UPFC) using a current injection method. Flexible AC Transmission System (FACTS) devices give more flexibility of control for security and economic operation of power systems. Diffculties of modeling UPFC in the conventional dynamic simulation programs arise from the fact that the injected voltage by the series inverter is superimposed on the shunt inverter side voltage. A solution can be a current injection method, in which a serial part of UPFC is converted to a parallel equivalent circuit using source transformation, and two current sources affect each other at every time step. To verify efficiency of this method, the proposed model is applied for the transient analysis of an example power system.

  • PDF

실리콘 산화막의 저레벨 누설전류에 관한 연구 (A Study on the Low Level Leakage Currents of Silicon Oxides)

  • 강창수;김동진
    • 전자공학회논문지T
    • /
    • 제35T권1호
    • /
    • pp.29-32
    • /
    • 1998
  • 실리콘 산화막에서 저레벨 누설전류를 조사하였다. 저레벨 누설전류는 전이요소와 직류요소로 구성되어 있다. 전이요소는 스트레스에 의해 두 계면트랩 가까이 발생된 트랩의 충방전에 의한 터널링으로 나타났으며 직류요소는 산화막을 통한 트랩 어시스트 터널링으로 나타났다 그리고 저레벨 누설전류는 산화막에서 발생된 트랩의 수에 비례하였다. 저레벨 누설전류는 트랩의 충방전 누설전류이며 비휘발성 소자의 데이터 유지능력에 영향을 주었다.

  • PDF

A Comparative Study of Controllers for CSI Fed Induction Motor

  • Kumar, Piush;Agarwal, Vineeta
    • Journal of Power Electronics
    • /
    • 제10권2호
    • /
    • pp.165-170
    • /
    • 2010
  • This paper presents a comparative study of P and PI controllers for a current source inverter (CSI) fed induction motor drive system. A dq model has been used which incorporates the induction motor and the inverter power supply with current feedback. The model is used first to generate the steady state curves to determine the operating point through computer simulations using the software package MATLAB. Then a transient analysis has been carried out for different values of the speed and current controller parameters. The controller value is adjusted by the Ziegler-Nichols method. It has been observed that the transient time to reach the steady state value is larger with the PI controller than with the P controller.

단일관망에서 누수효과를 고려한 천이류 분석 및 실험 (Transient Analysis and Experiment Considering Unsteady Friction and Leakage in a Pipeline System)

  • 이미현;송용석;김상현
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2006년도 학술발표회 논문집
    • /
    • pp.1395-1399
    • /
    • 2006
  • The current paper focuses the analysis of leakage detection in water pipeline systems by means of the transient analysis. In order to obtain pressure variation for evaluation the existing methodology, an extensive experimental process has been carried out in a single pipeline system. Several experimental tests were performed with and without a leakage in the system. Using the unsteady friction and improved unsteady friction factors, reasonable match between the computed and measured pressure were presented on the condition of the flow situations. The transient method attempts to estimate the leakage in water pipelines using observed pressure data collected during transient events on the system.

  • PDF

그리드접지와 심매설 접지전극의 과도임피던스 (Transient Impedance of the Ground Grid and Deeply-driven Ground Rod)

  • 이복희;이수봉;이태형;정현욱;정동철;길형준
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2005년도 춘계학술대회논문집
    • /
    • pp.240-243
    • /
    • 2005
  • This paper presents the transient behaviors of grounding system impedance against lighting impulse currents. The dynamic characteristics of the deeply driven ground rod and grounding grid subjected to the impulse current with various rise time were investigated. It was found that the transient ground impedance strongly depends on the configuration and size of grounding electrodes and the shapes of impulse currents, and the inductance of grounding electrodes has a significant affect on the transient ground impedance of grounding system in the short time domain.

  • PDF

혼합송전선로에서 고저항 지락사고시 케이블 과도현상 해석 및 전력케이블 시스 접지저항에 따른 CCPU 과도특성 모의 (Modeling and Transient Analysis of Cable in Combined Transmission Line with HIF and Analysis of Transient Characterstic in CCPU of Uderground Cable)

  • 정채균;이종범
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 A
    • /
    • pp.446-448
    • /
    • 2000
  • This paper discribes the modeling and transient analysis of cable in combined transmission line under high impedance fault(HIF). And also, transient characterstic analyzed on cable covering protection unit(CCPU) is presented. Modeling of the combined transmission line is established in PSCAD/EMTDC V3. The required data to analyze the transient phenomena is given from the actual system. The results show the HIF modeling in cable, fault current according to the value of fault resistance. And also when the value and method of grounding resistance is changed in CCPU, simulation results are presented.

  • PDF