A Study on Protection of Generator Asynchronization by Impedance Relaying (임피던스 계전기를 이용한 발전기 비동기 투입 보호 연구)

  • Lee, Jong-Hweon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.11
    • /
    • pp.2000-2006
    • /
    • 2011
  • Asynchronous phenomenon occurs on the synchronous generators under power system when a generator's amplitude of electromagnetic force, phase angle, frequency and waveform etc become different from those of other synchronous generators which can follow instantly varying speed of turbine. Because the amplitude of electromagnetic force, phase frequency and waveform differ from those of other generators with which are to be put into parallel operation due to the change of excitation condition for load sharing and the sharing load change, if reactive current in the internal circuit circulates among generators, the efficiency varies and the stator winding of generators are overheated by resistance loss. Where calculation method of protection settings and Logic for Protection of Generator Asynchronization will be recommended, A distance relay scheme is commonly used for backup protection. This scheme, called a step distance protection, is comprised of 3 steps for graded zones having different operating time. As for the conventional step distance protection scheme, Zone 2 can exceed the ordinary coverage excessively in case of a transformer protection relay especially. In this case, there can be overlapped protection area from a backup protection relay and, therefore, malfunctions can occur when any fault occurs in the overlapped protection area. Distance relays and overcurrent relays are used for backup protection generally, and both relays have normally this problem, the maloperation, caused by a fault in the overlapped protection area. Corresponding to an IEEE standard, this problem can be solved with the modification of the operating time. On the other hand, in Korea, zones are modified to cope with this problem in some specific conditions. These two methods may not be obvious to handle this problem correctly because these methods, modifying the common rules, can cause another coordination problem. To overcome asynchronizing protection this paper describes an improved backup protection coordination scheme using a new Logic that will be suggested.

Comparative Study of DC Breakdown and Space Charge Characteristics of Insulation Paper Impregnated with Natural Ester and Mineral Oil

  • Hao, Jian;Zou, Run-Hao;Liao, Rui-Jin;Yang, Li-Jun;Liao, Qiang;Zhu, Meng-Zhao
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.4
    • /
    • pp.1682-1691
    • /
    • 2018
  • Natural ester is a suitable substitute for mineral oil and has been widely used in AC transformer in many countries. In order to further application of natural ester in direct current (DC) equipment, it is needed to investigate its long term insulation property under DC condition. In this paper, a thermal ageing experiment was conducted for both mineral oil-paper and natural ester-paper insulation. The DC breakdown and space charge characteristics of insulation paper impregnated with natural ester and mineral oil was compared. Results show that the resistivity of the paper immersed in natural ester and mineral oil both increase as the ageing goes on. While insulation paper impregnated with natural ester has higher resistivity and DC breakdown voltage than the paper impregnated with mineral oil. The DC breakdown voltage for the oil impregnated insulation paper being DC pre-stressing is higher than that without pre-stressing. The average DC breakdown field strength difference between the test with pre-stressing and without pre-stressing clearly shows that there is an apparent enhancement effect for the homo-charge injection on the DC breakdown.

A Study On High Power Factor Sine Pulse Type Power Supply For Atmospheric Pressure Plasma Cleaning System with 3-Phase PFC Boost Converter (3상 PFC 부스트 컨버터를 채용한 상압플라즈마 세정기용 고역률 정형파 펄스 출력형 전원장치에 관한 연구)

  • Han, Hee-Min;Kim, Min-Young;Seo, Kwang-Duk;Kim, Joohn-Sheok
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.14 no.1
    • /
    • pp.72-81
    • /
    • 2009
  • This paper presents quasi-resonant type high power factor ac power supply for atmospheric pressure plasma cleaning system adopting three phase PFC boost converter and it's control method. The presented ac power supply consists of single phase H-bridge inverter, step-up transformer for generating high voltage and three phase PFC boost converter for high power factor on source utility. Unlikely to the traditional LC resonant converter, the propose one has an inductor inside only. A single resonant takes place through the inside inductor and the capacitor from the plasma load modeled into two series capacitor and one resistance. The quasi-resonant can be achieved by cutting the switching signal when the load current decrease to zero. To obtain power control ability, the propose converter controlled by two control schemes. One is the changing output pulse period scheme in the manner of PFM(Pulse Frequency Modulation) control. On the other, to provide more higher power to load, the DC rail voltage is directly controlled by the 3-phase PFC boost converter. The significant merits of the proposed converter are the uniform power providing capability for high quality plasma generation and low reactive power in AC and DC side. The proposed work is verified through digital simulation and experimental implementation.

A New High Frequency Linked Soft-Switching PWM DC-DC Converter with High and Low Side DC Rail Active Edge Resonant Snubbers for High Performance Arc Welder

  • Kang, Ju-Sung;Fathy, Khairy;Saha, Bishwajit;Hong, Doo-Sung;Suh, Ki-Young;Lee, Hyun-Woo;Nakaoka, Mutsuo
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2006.05a
    • /
    • pp.399-402
    • /
    • 2006
  • This paper presents a new circuit topology of dc bus line switch-assisted half-bridge soft switching PWM inverter type dc-dc converter for arc welder. The proposed power converter is composed of typical voltage source half-bridge high frequency PWM inverter with a high frequency transformer link in addition to dc bus line side power semiconductor switching devices fer PWM control scheme and capacitive lossless snubbers. All the active power switches in the half-bridge arm and dc bus lines can achieve ZCS turn-on and ZVS turn-off commutation operation and consequently the total turn-off switching losses can be significantly reduced. As a result, a high switching frequency of using IGBTs can be actually selected more than about 20 kHz. The effectiveness of this new converter topology is proved for low voltage and large current dc-dc power supplies such as arc welder from a practical point of view.

  • PDF

Study on Analysis of Operating Characteristics of Motor Block While KTX is Moving at Neutral Section of Kyung-Bu High Speed Line (경부고속선 절연구간에서 KTX 운행중 모터블럭의 동작특성 분석)

  • Choi, Chang Hyun;Lho, Young Hwan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.10
    • /
    • pp.1523-1527
    • /
    • 2015
  • Traction power is supplied by three-phase alternating current of 154 kV power grid and electric trains are operated on single phase feeding system. It becomes important to use all the three phases equally and convert them into two-phase electric power (90 degree phase rotation) for traction supply. This is achieved by special transformer from the adjacent traction substation which is separated by a neutral section. Neutral section locations are in front of the substation and between the two substations. The first stage of the Seoul-Busan high-speed railway, design curve radius is larger than 7,000 m and the greatest slope is 25‰. The railway track conditions are evaluated as good enough to install a neutral section at the first stage, but a few factors of coasting operation of the train should be considered at the second stage of Seoul-Busan high-speed railway. The neutral section was located at Kim-cheon substation, which made some neutral section problems produced by the operating train, and the neutral section was moved about 1.5 km to the south toward Dong Dae-gu station due to the track operation condition. Some of the trains which stopped at the existing Kim-cheon Gu-mi station produced another motor block failure after moving the neutral section. In this paper, power quality, system performance and track condition, etc. are suggested to solve the problems.

Electromagnetic Properties of Mo-Zn ferrite for Low Voltage and High Current Transformer Application With Using Multi cores (다중 코어를 이용한 저전압, 대전류 변압기용 Mn-Zn ferrite의 전자기적 특성)

  • Kim, Hyun-Sik;Lee, Hae-Yon;Kim, Jong-Ryung;Huh, Jeong-Seob;Lee, Jun-Hui;An, Yong-Woon;Oh, Young-Woo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.07a
    • /
    • pp.294-295
    • /
    • 2005
  • 다중 코어를 이용한 대전류 변압기용 Mn-Zn ferrite를 제조하고 전자기적 특성을 분석하였으며, 제조된 자심재료를 이용하여 변압기를 제조하고 전원장치에 탑재하여 효율특성을 분석하였다. ZnO의 몰비가 증가할수록 혼합 스피넬의 형성을 통한 보아 자자의 증가로 인해 투자율은 증가하고 상대적으로 전력손실이 감소하여 $Fe_2O_3$ : MnO : ZnO = 53 : 36 : 11 mo\% 일 때 가장 우수한 특성을 나타냈고, 열처리 공정의 승온 과정에서부터 산소 분압을 제어하고 최적의 대기압 상수를 산출함으로써 Zn-loss 현상을 최소화하여 ZnO 11 mol%, 대기압 상수 7.7일 때 투자율 2350, 밀도 4.9 $g/cm^3$, 비저항 480 ${\Omega}cm$, 300 mT의 최대 자속 밀도 특성을 갖는 우수한 자심 재료를 개발하였다. 그리고 최소 손실 온도를 $90^{\circ}C$ 이하로 감소시켰으며 100 kHz에서 250 $kW/m^3$의 낮은 전력손실을 나타냈다. 또한 개발된 자심재료를 이용하여 제조된 전원장치는 30~80A의 출력 전류에서 85% 이상의 고효율을 얻었다.

  • PDF

Dual-Coupled Inductor High Gain DC/DC Converter with Ripple Absorption Circuit

  • Yang, Jie;Yu, Dongsheng;Alkahtani, Mohammed;Yuan, Ligen;Zhou, Zhi;Zhu, Hong;Chiemeka, Maxwell
    • Journal of Power Electronics
    • /
    • v.19 no.6
    • /
    • pp.1366-1379
    • /
    • 2019
  • High-gain DC/DC converters have become one of the key technologies for the grid-connected operation of new energy power generation, and its research provides a significant impetus for the rapid development of new energy power generation. Inspired by the transformer effect and the ripple-suppressed ability of a coupled inductor, a double-coupled inductor high gain DC/DC converter with a ripple absorption circuit is proposed in this paper. By integrating the diode-capacitor voltage multiplying unit into the quadratic Boost converter and assembling the independent inductor into the magnetic core of structure coupled inductors, the adjustable range of the voltage gain can be effectively extended and the limit on duty ratio can be avoided. In addition, the volume of the magnetic element can be reduced. Very small ripples of input current can be obtained by the ripple absorption circuit, which is composed of an auxiliary inductor and a capacitor. The leakage inductance loss can be recovered to the load in a switching period, and the switching-off voltage spikes caused by leakage inductance can be suppressed by absorption in the diode-capacitor voltage multiplying unit. On the basis of the theoretical analysis, the feasibility of the proposed converter is verified by test results obtained by simulations and an experimental prototype.

A New High-Efficient Interleaved Converter for Low-Voltage and High-Current Power Systems (저전압 고전류 사양에 적합한 고효율 인터리브 컨버터)

  • Cho, In-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.10
    • /
    • pp.600-608
    • /
    • 2016
  • This paper proposes a new high-efficient interleaved phase-shift full-bridge (PSFB) converter for low-voltage and high-current power systems. The proposed converter is composed of three switch-bridges and two transformers in the primary side and two rectifiers in the secondary side. Each transformer handles half of the total power with an interleaved operation, so that the proposed converter has high system reliability, as much as the conventional interleaved PSFB converter. The soft-switching characteristics of the proposed converter are better than those of the conventional converter due to the modulated primary side configuration. The proposed converter represents a single lagging-leg bridge, which has a poor soft switching condition in its operation, while the conventional converter has two lagging-leg bridges in its operation. Therefore, the number of switches having hard-switching conditions is reduced by half in the proposed converter. In addition, the reduced switch counts in the primary side of the proposed converter helps decrease the complexity of the proposed converter compared to that of the conventional converter. The operational principle and analysis are presented in this paper and the characteristics are verified using a PSIM simulation with 3kW server power specification.

A Time Comparison Measurement Technique for eLoran Receivers (시각비교를 위한 eLoran 수신기 지연측정 기술)

  • Lee, Chang-Bok;Lee, Jong-Koo;Lee, Young-Kyu;Hwang, Sang-wook;Yang, Sung-Hoon
    • Journal of Navigation and Port Research
    • /
    • v.40 no.6
    • /
    • pp.385-390
    • /
    • 2016
  • ELoran Systems can provide Position, Navigation, and Time services with comparable performance to Global Positioning Systems (GPS) as a back up or alternative system. High timing and navigation performance can be achieved by eLoran signals because eLoran receivers use "all-in-view" reception. This incorporates Time of Arrival (TOA) signals from all stations in the service range because each eLoran station is synchronized to Coordinated Universal Time (UTC). Transmission station information and the differential Loran correction data are transmitted via an additional Loran Data Channel (LDC) on the transmitted eLoran signal such that eLoran provides improved Position Navigation and Timing (PNT) over legacy Loran. In this paper, we propose a technique for adapting the delay time compensation values in eLoran timing receivers to provide precise time comparison. For this purpose, we have designed a system that measures time delay from the crossing point of the third cycle extracted from the current transformer at the end point of the transmitter. The receiver delay was measured by connecting an active H-field, an E-field and a passive loop antenna to a commercial eLoran timing receiver. The common-view time transfer technique using the calibrated eLoran timing receiver improved the eLoran transfer time. A eLoran timing receiver calibrated by this method can be utilized in the field for precise time comparison as a GNSS backup.

A Study on Fault Characteristics of Wind Power in Distribution Feeders (풍력발전(DFIG)의 고압배전선로의 사고특성 해석에 관한 연구)

  • Kim, So-Hee;Kim, Byung-Ki;Rho, Dae-Seok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.3
    • /
    • pp.1288-1295
    • /
    • 2012
  • Korea Ministry of Knowledge Economy has estimated that wind power (WP) will be occupied 37% in 2020 and 42% in 2030 of the new energy sources, and also green energies such as photovoltaic (PV) and WP are expected to be interconnected with the distribution system because of Renewable Portfolio Standard (RPS) starting from 2012. However, when a large scale wind power plant (over 3[MW]) is connected to the traditional distribution system, protective devices (mainly OCR and OCGR of re-closer) will be occurred mal-function problems due to changed fault currents it be caused by Wye-grounded/Delta winding of interconnection transformer and %impedance of WP's turbine. Therefore, when Double-Fed Induction Generator (DFIG) of typical WP's Generator is connected into distribution system, this paper deals with analysis three-phase short, line to line short and a single line ground faults current by using the symmetrical components of fault analysis and PSCAD/EMTDC modeling.