• Title/Summary/Keyword: Current pulse

Search Result 1,872, Processing Time 0.034 seconds

Research on ANN based on Simulated Annealing in Parameter Optimization of Micro-scaled Flow Channels Electrochemical Machining (미세 유동채널의 전기화학적 가공 파라미터 최적화를 위한 어닐링 시뮬레이션에 근거한 인공 뉴럴 네트워크에 관한 연구)

  • Byung-Won Min
    • Journal of Internet of Things and Convergence
    • /
    • v.9 no.3
    • /
    • pp.93-98
    • /
    • 2023
  • In this paper, an artificial neural network based on simulated annealing was constructed. The mapping relationship between the parameters of micro-scaled flow channels electrochemical machining and the channel shape was established by training the samples. The depth and width of micro-scaled flow channels electrochemical machining on stainless steel surface were predicted, and the flow channels experiment was carried out with pulse power supply in NaNO3 solution to verify the established network model. The results show that the depth and width of the channel predicted by the simulated annealing artificial neural network with "4-7-2" structure are very close to the experimental values, and the error is less than 5.3%. The predicted and experimental data show that the etching degree in the process of channels electrochemical machining is closely related to voltage and current density. When the voltage is less than 5V, a "small island" is formed in the channel; When the voltage is greater than 40V, the lateral etching of the channel is relatively large, and the "dam" between the channels disappears. When the voltage is 25V, the machining morphology of the channel is the best.

A Study for the Efficient Improvement Measures of Military EMP Protection Ability (국방 EMP 방호능력의 효율적 개선을 위한 방안 연구)

  • Jung, Seunghoon;An, Jae-Choon;Hwang, Yeung-Kyu;Jung, Hyun-Ju;Shin, Yongtae
    • Asia-pacific Journal of Multimedia Services Convergent with Art, Humanities, and Sociology
    • /
    • v.7 no.1
    • /
    • pp.219-227
    • /
    • 2017
  • Current military command information system uses electronic equipment a lot on which semiconductor chip is attached. It seems its' importance will increase more with latest information communication technology developing. Electronic equipment which uses electricity contains regular tolerance to high output electric signal. And EMC specification is the standardized of this electronic equipment's tolerance. On the other hand, the Institute of Atomic Energy Research has ever declared that high output electromagnetic pulse(EMP) will be broken out within the radius of 170Km when 10kt nuclear explosion occurs at an altitude of 40Km above Seoul. Then, the region suffer from the damage of most electronic equipments. Therefore, the norm to protect the influences in that case is defined by EMP protection specification. Most common electronic equipments meet the EMC norm, but there is no way to check whether they meet the EMP norm or not. That is because it is difficult to check whether they meet EMP protection norm and is on the matter of cost. Except inevitable cases, there is no review of checking whether they meet the norm or not. Considering the above, in this research, we speculate about the measures to improve military EMP protection ability by analyzing the EMC-EMP correlation and checking the EMP protection ability of general electronic equipment through the analysis.

Carbon nanotube field emission display

  • Chil, Won-Bong;Kim, Jong-Min
    • Electrical & Electronic Materials
    • /
    • v.12 no.7
    • /
    • pp.7-11
    • /
    • 1999
  • Fully sealed field emission display in size of 4.5 inch has been fabricated using single-wall carbon nanotubes-organic vehicle com-posite. The fabricated display were fully scalable at low temperature below 415$^{\circ}C$ and CNTs were vertically aligned using paste squeeze and surface rubbing techniques. The turn-on fields of 1V/${\mu}{\textrm}{m}$ and field emis-sion current of 1.5mA at 3V/${\mu}{\textrm}{m}$ (J=90${\mu}{\textrm}{m}$/$\textrm{cm}^2$)were observed. Brightness of 1800cd/$m^2$ at 3.7V/${\mu}{\textrm}{m}$ was observed on the entire area of 4.5-inch panel from the green phosphor-ITO glass. The fluctuation of the current was found to be about 7% over a 4.5-inch cath-ode area. This reliable result enables us to produce large area full-color flat panel dis-play in the near future. Carbon nanotubes (CNTs) have attracted much attention because of their unique elec-trical properties and their potential applica-tions [1, 2]. Large aspect ratio of CNTs together with high chemical stability. ther-mal conductivity, and high mechanical strength are advantageous for applications to the field emitter [3]. Several results have been reported on the field emissions from multi-walled nanotubes (MWNTs) and single-walled nanotubes (SWNTs) grown from arc discharge [4, 5]. De Heer et al. have reported the field emission from nan-otubes aligned by the suspension-filtering method. This approach is too difficult to be fully adopted in integration process. Recently, there have been efforts to make applications to field emission devices using nanotubes. Saito et al. demonstrated a car-bon nanotube-based lamp, which was oper-ated at high voltage (10KV) [8]. Aproto-type diode structure was tested by the size of 100mm $\times$ 10mm in vacuum chamber [9]. the difficulties arise from the arrangement of vertically aligned nanotubes after the growth. Recently vertically aligned carbon nanotubes have been synthesized using plasma-enhanced chemical vapor deposition(CVD) [6, 7]. Yet, control of a large area synthesis is still not easily accessible with such approaches. Here we report integra-tion processes of fully sealed 4.5-inch CNT-field emission displays (FEDs). Low turn-on voltage with high brightness, and stabili-ty clearly demonstrate the potential applica-bility of carbon nanotubes to full color dis-plays in near future. For flat panel display in a large area, car-bon nanotubes-based field emitters were fabricated by using nanotubes-organic vehi-cles. The purified SWNTs, which were syn-thesized by dc arc discharge, were dispersed in iso propyl alcohol, and then mixed with on organic binder. The paste of well-dis-persed carbon nanotubes was squeezed onto the metal-patterned sodalime glass throuhg the metal mesh of 20${\mu}{\textrm}{m}$ in size and subse-quently heat-treated in order to remove the organic binder. The insulating spacers in thickness of 200${\mu}{\textrm}{m}$ are inserted between the lower and upper glasses. The Y\ulcornerO\ulcornerS:Eu, ZnS:Cu, Al, and ZnS:Ag, Cl, phosphors are electrically deposited on the upper glass for red, green, and blue colors, respectively. The typical sizes of each phosphor are 2~3 micron. The assembled structure was sealed in an atmosphere of highly purified Ar gas by means of a glass frit. The display plate was evacuated down to the pressure level of 1$\times$10\ulcorner Torr. Three non-evaporable getters of Ti-Zr-V-Fe were activated during the final heat-exhausting procedure. Finally, the active area of 4.5-inch panel with fully sealed carbon nanotubes was pro-duced. Emission currents were character-ized by the DC-mode and pulse-modulating mode at the voltage up to 800 volts. The brightness of field emission was measured by the Luminance calorimeter (BM-7, Topcon).

  • PDF

Pediatric Endoscopic Sedation in Korea: A Survey of the Korean Society of Pediatric Gastroenterology, Hepatology and Nutrition (소아청소년 진정내시경: 대한소아소화기영양학회 학술위원회 조사 보고)

  • Ryoo, Eell;Kim, Kyung-Mo
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.11 no.1
    • /
    • pp.21-27
    • /
    • 2008
  • Purpose: The aim of this survey was to analyze the choice of sedative drugs and their side effects during pediatric endoscopic sedation in Korea. We also evaluated doctors, caretakers and patient satisfaction with the procedures. Methods: Between June 2006 and July 2006, a 16-item survey regarding current sedation practices, during one month, was mailed to 28 hospitals in Korea. The results of the survey responses were then analyzed. Results: Endoscopy performed under conscious sedation was reported in 89.0% of the responders and endoscopy under general anesthesia in 0.9% of 465 endoscopic procedures. Endoscopy under conscious sedation was performed in 89.1% for upper gastrointestinal endoscopy (GFS) and 88.1% for lower GFS. Midazolam was used for conscious sedation during the endoscopy in 84.5% of cases and propofol was used in two cases (0.5%). In addition, a bezodiazepine/opioid combination was used iin 84.6% (44 cases) for lower GFS. Patients were monitored with pulse oxymetry, EKG (91.4%) as well as automatic BP (5.1%). Transient hypoxia was the only side effect noted and was treated with supplemental oxygen (4.6%). Flumazenil was used in 2.71% of cases. The choice of sedation was made by the endoscopist (84%). The satisfaction rate for endoscopists was 68%, and for the patients and caretakers was 84% (as reported by the endoscopists). Conclusion: Midazolam was used only for the upper GFS and benzodiazepine/opioid combination was used for the lower GFS in Korea. The rate of satisfaction was relatively high and there were no significant side effects noted during the endoscopy under conscious sedation.

  • PDF

Effect of Sa-am Acupuncture Method for Chronic Tension-type Headache;A Randomized Controlled Trial (만성 긴장성 두통 환자에 대한 사암침 치료효과의 Pilot 임상연구)

  • Hong, Kwon-Eui;Park, Yang-Chun;Jo, Jeong-Hyo;Jo, Hyun-Gyeong;Jeong, In-Cheol;Kang, Wee-Chang;Lee, Sang-Bong;Choi, Sun-Mi
    • Journal of Acupuncture Research
    • /
    • v.24 no.1
    • /
    • pp.13-28
    • /
    • 2007
  • Objectives : Clinical character of chronic tension-type headache is bilateral, moderate intensity, persistent and chronic, repeating disease and CTTH is a common prevalent disease, but pathophysiology and likely mechanism remain unclear. It impedes subjective quality of life. The purpose of this research is to examine the effect of sa-am acupuncture method for chronic tension-type headache. Methods : In this randomized, single blind, placebo-controlled study, we compared active acupuncture with sham acupuncture for the treatment of chronic tension-type headache. Volunteers who satisfied the requirements were enrolled in study. Evaluation of chronic tension-type headache was measured by VAS and Headache Disability Inventory(HDI), Six point Linkert Scale before and after treatments. Results : 26 subjects finished study. There were not difference between two groups on age, sex, weight, height, blood pressure, pulse, respiratory rate, Byeonjeung, sunrise of treatment. In change of VAS, there were not difference between two groups on before treatment. Before treatment per visit, VAS of 6th and 7th visit were significantly decreased in active acupuncture(each p=0.039, p=0.008) and were not decreased in sham acupuncture. In change of VAS on a withdrawing needling after treatment, VAS of 1st, 2nd, 6th and 7th visit were significantly decreased in active acupuncture (each p=0.001, 0.038, 0.035, 0.008) and VAS of 2nd, 4th and 5th, 6th visit were significantly decreased in sham acupuncture(each p=0.033, 0.032, 0.035, 0.031). In change of VAS on 2hrs after treatment, VAS of 4th and 5th, 6th visit were significantly decreased in active acupuncture(each p=0.014, 0.023, 0.027) and 5th visit were significantly decreased in sham acupuncture(each p=0.004, 0.009). In change of VAS on 4hrs after treatment, VAS of 4th and 5th, 6th visit were significantly decreased in active acupuncture(each p=0.018, 0.011, 0.015) and 5th, 6th visit were significantly decreased in sham acupuncture(each p=0.020, 0.015). In change of VAS on the next day after treatment, VAS of 3th and 4th and 5th, 6th visit were significantly decreased in active acupuncture(each p=0.032, 0.011, 0.005, 0.012) and 4th, 5th visit were significantly decreased in sham acupuncture(each p=0.001, 0.012). In change of VAS according to a current time(before treatment, after a withdrawing needling, 2hrs, 4hrs, the next day), total score of VAS was decreased more active acupuncture group than sham acupuncture group, but there were no statistical significance compared with sham acupuncture group. In change of HDI score, after treatment was decreased than before treatment in two group, but there were no statistical significance compared with two group. In change of Six point Linkert scale score, after treatment was decreased than before treatment in two group on 6th, 7th visit(active acupuncture 6th 7th each p=0.002, 0.003, sham acupuncture 6th 7th each 0.003, 0.009), but there were no statistical significance compared with tow group. Conclusion : Sa-am acupuncture treatment is effective to improve the symptoms and quality of life in patients with chronic tension-type headache.

  • PDF

Study on Effect of Varience of Physiological Responses in Color Foot Reflexology Using Color Light (컬러광을 활용한 발반사요법이 인체 생리적 반응 변화에 미치는 영향에 관한 연구)

  • Jin, Hye-Ryeon;Yu, Mi;Park, Kyung-Jun;Kim, Nam-Gyun;Chung, Sung-Whan;Kim, Dong-Wook
    • Science of Emotion and Sensibility
    • /
    • v.13 no.1
    • /
    • pp.187-196
    • /
    • 2010
  • Recently, people have been suffering from stress-related fatigue and psychological disorders. Most people depend on medicine for pain relief; many treat pain also through alternative medicine or replacement therapy. However, drug therapy has many side effects, including increased stress after the therapy. In comparison, alternative therapies such as massage and foot reflexology are less damaging to the body, and such therapies can be provided without physical or psychological discomfort. In this regard, the author had previously co-developed color foot reflexology, which combines the merits of color therapy and foot reflexology; color foot reflexology has been shown to have beneficial effects without undue pain. This study investigates the effects of color foot reflexology on the physiological response of the body by comparing the body’s response to the signal with that to the placebo. Healthy adult subjects were selected for the experiment, which was conducted under optimal experimental conditions and design. The results indicated that when stimulated, parasympathetic nerves increased in HRV and that blood pressure, pulse, body heat, peripheral blood flow were dramatically activated. However, the results for the placebo indicated minimal changes or irregular outcomes. The results provide strong evidence for the beneficial effects of the color foot reflexology instrument on the autonomic nervous system and on the physiological response of the body. Future research is warranted to verify the results of the current study by examining patients suffering from diseases and disorders arising from irregular physiological functions in the context of the foot.

  • PDF

The Effects on Dose Distribution Characteristics by Changing Beam Tuning Parameters of Digital Linear Accelerator in Medicine (의료용 디지털 선형가속기의 빔조정 인자변화가 선량분포특성에 미치는 영향)

  • 박현주;이동훈;이동한;권수일;류성렬;지영훈
    • Progress in Medical Physics
    • /
    • v.10 no.1
    • /
    • pp.17-22
    • /
    • 1999
  • INJ-I, INJ-E, PFN, BMI, and PRF were selected among the various factors which constitute a digital linear accelerator to find effects on the dose distribution by changing current and voltage within the permitted scale which Mevatron automatically maintained. We measured the absorbed dose using an ion chamber, analyzed the waveform of beam output using an oscilloscope, and measured symmetry and flatness using a dosimetry system. An RFA plus (Scanditronix, Sweden) device was used as a dosimetry system. Then an 0.6cc ion chamber (PR06C, USA), an electrometer (Capintec192, USA), and an oscilloscope (Tektronix, USA) were employed to measure the changes on the dose distribution characteristics by changing the beam-tuning parameters. When the currents and the voltages of INJ-I, INJ-E, PFN, BMI, and PRF were modified, we were able to see the notable change on the dose rate by examining the change of the output pulse using the oscilloscope and by measuring them using the ion chamber. However, the results of energy and flatness graph from RF A plus were almost identical. The factors had fine differences: INJ-I, INJ-E, PFN, BMI, and PRF had 0.01∼0.02% differences in D10/D20, 0.1∼0.2 % differences in symmetry, and 0.1∼0.4% differences in flatness. Since Mevatron controlled itself automatically to keep the reference value of the factor, it was not able to see large differences in the dose distribution. There were fine differences on the dose rate distribution when the voltage and the currents of the digitized factors were modified Nonetheless, a basic operational management information was achieved.

  • PDF

Doses of Coronary Study in 64 Channel Multi-Detector Computed Tomography : Reduced Radiation Dose According to Varity of Examnination Protocols (64 채널 Multi-Detector Computed Tomography를 이용한 관상동맥검사의 선량 : 검사 프로토콜 다변화에 따른 환자선량 감소)

  • Kim, Moon-Chan
    • Journal of radiological science and technology
    • /
    • v.32 no.3
    • /
    • pp.299-306
    • /
    • 2009
  • Purpose : To compare radiation dose for coronary CT angiography (CTA) obtained with 6 examination protocols such as a retrospectively ECG gated helical scan, a prospectively ECG gated sequential scan, low kVp technique, and cardiac dose modulation technique. Materials and Methods : Coronary CTA was performed by using 6 current clinical protocols to evaluate effective dose and organ dose in primary beam area with anthropomorphic female phantom and glass dosimetric system in 64 channel multi-detector CT. After acquiring topograms of frontal and lateral projection with 80 kVp and 10 mA, main coronary scan was done with 0.35 sec tube rotation time, 40 mm collimation ($0.625\;mm{\times}64\;ea$), small scan field of view (32 cm diameter), 105 mm scan length. Heart beat rate of phantom was maintained 60 bpm in ECG gating. In constant mAs technique 120 kVp, 600 mA was used, and 100 kVp for low kVp technique. In a retrospectively ECG gated helical CT technique 0.22 pitch was used, peak mA (600 mA) was adopted in range of $40{\sim}80%$ of R-R interval and 120mA(80% reduction) in others with cardiac dose modulation. And 210 mAs was used without cardiac dose modulation. In a prospectively ECG gated sequential CT technique data were acquired at 75% R-R interval (middle diastolic phase in cardiac cycle), and 120 msec additional padding of the tube-on time was used. For effective dose calculation region specific conversion factor of dose length product in thorax was used, which was recommended by EUR 16262. Results : The mean effective dose for conventional coronary CTA without cardiac dose modulation in a retrospectively ECG gated helical scan was 17.8 mSv, and mean organ dose of heart was 103.8 mGy. With low kVp and cardiac dose modulation the mean effective dose showed 54.5% reduction, and heart dose showed 52.3% reduction, compared with that of conventional coronary CTA. And at the sequential scan(SnapShot pulse mode) under prospective ECG gating the mean effective dose was 4.9 mSv, this represents an 72.5% reduction compared with that of conventional coronary CTA. And heart dose was 33.8 mGy, this represents 67.4% reduction. In the sequential scan technique under prospective ECG gating with low kVp the mean effective dose was 3.0 mSv, this represents an 83.2% reduction compared with that of conventional coronary CTA. And heart dose was 17.7 mGy, this represents an 82.9% reduction. Conclusion : In coronary CTA at retrospectively ECG gated helical scan, cardiac dose modulation technique using low kVp reduced dose to 50% above compared with the conventional helical scan. And the prospectively ECG gated sequential scan offers substantially reduced dose compared with the traditional retrospectively ECG gated helical scan.

  • PDF

A Survey on Treatment of Breast Cancer Patients with Korean Medicine: Preliminary Research for Clinical Practice Guidelines (한의표준임상진료지침 개발을 위한 유방암 보완치료 실태조사)

  • Kim, Nam-Hoon;Kang, Na-Hoon;Yoo, Eun-Sil;Park, Nam-Chun;Lee, Jin-Wook;Park, Kyoung-Sun;Lee, Jin-Moo;Lee, Chang-Hoon;Jang, Jun-Bock;Jang, Bo-Hyoung;Hwang, Deok-Sang
    • The Journal of Korean Obstetrics and Gynecology
    • /
    • v.31 no.4
    • /
    • pp.165-178
    • /
    • 2018
  • Objectives: To determine the current status of the treatment of breast cancer patients by Korean Medicine doctors (KMDs) and to examine the need for clinical practice guidelines (CPGs) for the supportive care of these patients. Methods: This cross-sectional study used a self-administered questionnaire. Participants were asked about their experience in treating breast cancer patients; the number of breast cancer patients they currently treat; the main complaints expressed by, diagnoses of, and treatments used for such patients; and their opinions about Korean Medicine (KM) as the basis for providing supportive care for breast cancer. Results: The data for this study were collected from 322 respondents. 84 of whom reported having ever treated patients with breast cancer. Most breast cancer patients who visited the KM clinic were classified as stage I or II, and their major complaints were fatigue, general weakness and musculoskeletal pain. The major diagnostic strategies were syndrome differentiation and pulse diagnosis. The major treatments administered were herbal medicine, acupuncture, and moxibustion. KMDs cited a need for medical information, such as CPGs, as their most important concern with regard to the treatment of breast cancer patients. Conclusions: This survey determined the prevalence of the use of KM for Korean breast cancer patients. Our results underscore the need for clinical practice guidelines for using of KM as the basis of supportive care for breast cancer and for informing clinicians and patients about this approach.

Recent Progress in Air Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2007 (설비공학 분야의 최근 연구 동향 : 2007년 학회지 논문에 대한 종합적 고찰)

  • Han, Hwa-Taik;Shin, Dong-Sin;Choi, Chang-Ho;Lee, Dae-Young;Kim, Seo-Young;Kwon, Yong-Il
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.12
    • /
    • pp.844-861
    • /
    • 2008
  • The papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during the year of 2007 have been reviewed. Focus has been put on current status of research in the aspect of heating, cooling, ventilation, sanitation and building environments. The conclusions are as follows. (1) The research trends of fluid engineering have been surveyed as groups of general fluid flow, fluid machinery and piping, etc. New research topics include micro nano fluid, micropump and fuel cell. Traditional CFD was still popular and widely used in research and development. Studies about fans and pumps were performed in the field of fluid machinery. Characteristics of flow and fin shape optimization are studied in the field of piping system. (2) The research works on heat transfer have been reviewed in the field of heat transfer characteristics, heat exchangers, and desiccant cooling systems. The research on heat transfer characteristics includes thermal transport in pulse tubes, high temperature superconductors, ground heat exchangers, fuel cell stacks and ice slurry systems. For the heat 'exchangers, the research on pin-tube heat exchanger, plate heat exchanger, condensers and gas coolers has been cordially implemented. The research works on heat transfer augmenting tubes have been also reported. For the desiccant cooling systems, the studies on the design and operating conditions for desiccant rotors as well as performance index are noticeable. (3) In the field of refrigeration, many papers were presented on the air conditioning system using CO2 as a refrigerant. The issues on the two-stage compression, the oil selection, and the appropriate oil charge were treated. The subjects of alternative refrigerants were also studied steadily. Hydrocarbons, DME and their mixtures were considered and various heat transfer correlations were proposed. (4) Research papers have been reviewed in the field of building facilities by grouping into the researches on heat and cold sources, air conditioning and air cleaning, ventilation and fire research including tunnel ventilation, flow control of piping system, and sound research with drain system. Main focuses have been addressed to the promotion of efficient or effective use of energy, which helps to save energy and results in reduced environmental pollution and operating cost. (5) Studies were mostly focused on analyzing the indoor environment in various spaces like cars, old tombs, machine rooms, and etc. in an architectural environmental field. Moreover, subjects of various fields such as the evaluation of noise, thermal environment, indoor air quality and development of energy analysis program were researched by various methods of survey, simulation, and field experiment.